Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Open Heart ; 11(1)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38458769

RESUMO

PURPOSE: The main objective of this study was to develop two-dimensional (2D) phase contrast (PC) methods to quantify the helicity and vorticity of blood flow in the aortic root. METHODS: This proof-of-concept study used four-dimensional (4D) flow cardiovascular MR (4D flow CMR) data of five healthy controls, five patients with heart failure with preserved ejection fraction and five patients with aortic stenosis (AS). A PC through-plane generated by 4D flow data was treated as a 2D PC plane and compared with the original 4D flow. Visual assessment of flow vectors was used to assess helicity and vorticity. We quantified flow displacement (FD), systolic flow reversal ratio (sFRR) and rotational angle (RA) using 2D PC. RESULTS: For visual vortex flow presence near the inner curvature of the ascending aortic root on 4D flow CMR, sFRR demonstrated an area under the curve (AUC) of 0.955, p<0.001. A threshold of >8% for sFRR had a sensitivity of 82% and specificity of 100% for visual vortex presence. In addition, the average late systolic FD, a marker of flow eccentricity, also demonstrated an AUC of 0.909, p<0.001 for visual vortex flow. Manual systolic rotational flow angle change (ΔsRA) demonstrated excellent association with semiautomated ΔsRA (r=0.99, 95% CI 0.9907 to 0.999, p<0.001). In reproducibility testing, average systolic FD (FDsavg) showed a minimal bias at 1.28% with a high intraclass correlation coefficient (ICC=0.92). Similarly, sFRR had a minimal bias of 1.14% with an ICC of 0.96. ΔsRA demonstrated an acceptable bias of 5.72°-and an ICC of 0.99. CONCLUSION: 2D PC flow imaging can possibly quantify blood flow helicity (ΔRA) and vorticity (FRR). These imaging biomarkers of flow helicity and vorticity demonstrate high reproducibility for clinical adoption. TRIALS REGISTRATION NUMBER: NCT05114785.


Assuntos
Estenose da Valva Aórtica , Imageamento por Ressonância Magnética , Humanos , Coração , Hemodinâmica , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Estudo de Prova de Conceito
2.
BMJ Open ; 12(3): e058552, 2022 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-35296488

RESUMO

PURPOSE: Retinal signatures of systemic disease ('oculomics') are increasingly being revealed through a combination of high-resolution ophthalmic imaging and sophisticated modelling strategies. Progress is currently limited not mainly by technical issues, but by the lack of large labelled datasets, a sine qua non for deep learning. Such data are derived from prospective epidemiological studies, in which retinal imaging is typically unimodal, cross-sectional, of modest number and relates to cohorts, which are not enriched with subpopulations of interest, such as those with systemic disease. We thus linked longitudinal multimodal retinal imaging from routinely collected National Health Service (NHS) data with systemic disease data from hospital admissions using a privacy-by-design third-party linkage approach. PARTICIPANTS: Between 1 January 2008 and 1 April 2018, 353 157 participants aged 40 years or older, who attended Moorfields Eye Hospital NHS Foundation Trust, a tertiary ophthalmic institution incorporating a principal central site, four district hubs and five satellite clinics in and around London, UK serving a catchment population of approximately six million people. FINDINGS TO DATE: Among the 353 157 individuals, 186 651 had a total of 1 337 711 Hospital Episode Statistics admitted patient care episodes. Systemic diagnoses recorded at these episodes include 12 022 patients with myocardial infarction, 11 735 with all-cause stroke and 13 363 with all-cause dementia. A total of 6 261 931 retinal images of seven different modalities and across three manufacturers were acquired from 1 54 830 patients. The majority of retinal images were retinal photographs (n=1 874 175) followed by optical coherence tomography (n=1 567 358). FUTURE PLANS: AlzEye combines the world's largest single institution retinal imaging database with nationally collected systemic data to create an exceptional large-scale, enriched cohort that reflects the diversity of the population served. First analyses will address cardiovascular diseases and dementia, with a view to identifying hidden retinal signatures that may lead to earlier detection and risk management of these life-threatening conditions.


Assuntos
Hospitais , Medicina Estatal , Adulto , Estudos Transversais , Humanos , Londres/epidemiologia , Estudos Prospectivos
3.
Front Cardiovasc Med ; 8: 816985, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35242820

RESUMO

BACKGROUND: The quantitative measures used to assess the performance of automated methods often do not reflect the clinical acceptability of contouring. A quality-based assessment of automated cardiac magnetic resonance (CMR) segmentation more relevant to clinical practice is therefore needed. OBJECTIVE: We propose a new method for assessing the quality of machine learning (ML) outputs. We evaluate the clinical utility of the proposed method as it is employed to systematically analyse the quality of an automated contouring algorithm. METHODS: A dataset of short-axis (SAX) cine CMR images from a clinically heterogeneous population (n = 217) were manually contoured by a team of experienced investigators. On the same images we derived automated contours using a ML algorithm. A contour quality scoring application randomly presented manual and automated contours to four blinded clinicians, who were asked to assign a quality score from a predefined rubric. Firstly, we analyzed the distribution of quality scores between the two contouring methods across all clinicians. Secondly, we analyzed the interobserver reliability between the raters. Finally, we examined whether there was a variation in scores based on the type of contour, SAX slice level, and underlying disease. RESULTS: The overall distribution of scores between the two methods was significantly different, with automated contours scoring better than the manual (OR (95% CI) = 1.17 (1.07-1.28), p = 0.001; n = 9401). There was substantial scoring agreement between raters for each contouring method independently, albeit it was significantly better for automated segmentation (automated: AC2 = 0.940, 95% CI, 0.937-0.943 vs manual: AC2 = 0.934, 95% CI, 0.931-0.937; p = 0.006). Next, the analysis of quality scores based on different factors was performed. Our approach helped identify trends patterns of lower segmentation quality as observed for left ventricle epicardial and basal contours with both methods. Similarly, significant differences in quality between the two methods were also found in dilated cardiomyopathy and hypertension. CONCLUSIONS: Our results confirm the ability of our systematic scoring analysis to determine the clinical acceptability of automated contours. This approach focused on the contours' clinical utility could ultimately improve clinicians' confidence in artificial intelligence and its acceptability in the clinical workflow.

4.
Heart ; 106(11): 824-829, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31822572

RESUMO

OBJECTIVE: In patients with hypertrophic cardiomyopathy (HCM), the role of small vessel disease and myocardial perfusion remains incompletely understood and data on absolute myocardial blood flow (MBF, mL/g/min) are scarce. We measured MBF using cardiovascular magnetic resonance fully quantitative perfusion mapping to determine the relationship between perfusion, hypertrophy and late gadolinium enhancement (LGE) in HCM. METHODS: 101 patients with HCM with unobstructed epicardial coronary arteries and 30 controls (with matched cardiovascular risk factors) underwent pixel-wise perfusion mapping during adenosine stress and rest. Stress, rest MBF and the myocardial perfusion reserve (MPR, ratio of stress to rest) were calculated globally and segmentally and then associated with segmental wall thickness and LGE. RESULTS: In HCM, 79% had a perfusion defect on clinical read. Stress MBF and MPR were reduced compared with controls (mean±SD 1.63±0.60 vs 2.30±0.64 mL/g/min, p<0.0001 and 2.21±0.87 vs 2.90±0.90, p=0.0003, respectively). Globally, stress MBF fell with increasing indexed left ventricle mass (R2 for the model 0.186, p=0.036) and segmentally with increasing wall thickness and LGE (both p<0.0001). In 21% of patients with HCM, MBF was lower during stress than rest (MPR <1) in at least one myocardial segment, a phenomenon which was predominantly subendocardial. Apparently normal HCM segments (normal wall thickness, no LGE) had reduced stress MBF and MPR compared with controls (mean±SD 1.88±0.81 mL/g/min vs 2.32±0.78 mL/g/min, p<0.0001). CONCLUSIONS: Microvascular dysfunction is common in HCM and associated with hypertrophy and LGE. Perfusion can fall during vasodilator stress and is abnormal even in apparently normal myocardium suggesting it may be an early disease marker.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Circulação Coronária/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Microcirculação/fisiologia , Imagem de Perfusão do Miocárdio/métodos , Cardiomiopatia Hipertrófica/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Feminino , Seguimentos , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Open Heart ; 6(1): e000920, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30997123

RESUMO

Introduction: Routine measurement of the outcome of myocardial infarction is usually limited to immediate morbidity and mortality. Our aim was to determine the response to patient-reported outcome measures (PROMs) 3 months later, identify response bias and explore the feasibility of comparing outcome with their recalled view of their prior health state. Methods: Patients admitted with ST-segment-elevation myocardial infarction (STEMI) to five percutaneous coronary intervention centres were invited to complete a retrospective questionnaire containing the EQ-5D-3L and short form Seattle Angina Questionnaire (SAQ-7). Response rate for a 3-month mailed follow-up questionnaire and potential response biases were assessed. Patients' outcomes were compared with their baseline using χ2 and paired t-test to assess for differences. Results: Of 392 patients contacted, 260 (66.3%) responded. Responders were more likely to be older, female, more affluent and have a higher EQ-5D at baseline. Three months after surgery, patients' SAQ-7 and angina symptom subscale returned to their baseline score. The physical limitation subscale score was worse than at baseline (79.9 vs 73.2, p=0.002), whereas the quality-of-life subscale was better (66.6 vs 73.9; p<0.001). The EQ-5D-3L index score was similar at 3 months to baseline (0.82 vs 0.79). Evidence of bias arising from responders being in better general health at baseline needs further investigation and, if confirmed, needs to be taken into account in interpreting PROMs data. Conclusion: It is feasible to use PROMs routinely to assess the impact of emergency admissions of patients with STEMI. A larger demonstration project with more sites is needed to confirm these findings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA