Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nat Methods ; 21(3): 455-464, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38302659

RESUMO

Prime editing (PE) is a powerful gene-editing technique based on targeted gRNA-templated reverse transcription and integration of the de novo synthesized single-stranded DNA. To circumvent one of the main bottlenecks of the method, the competition of the reverse-transcribed 3' flap with the original 5' flap DNA, we generated an enhanced fluorescence-activated cell sorting reporter cell line to develop an exonuclease-enhanced PE strategy ('Exo-PE') composed of an improved PE complex and an aptamer-recruited DNA-exonuclease to remove the 5' original DNA flap. Exo-PE achieved better overall editing efficacy than the reference PE2 strategy for insertions ≥30 base pairs in several endogenous loci and cell lines while maintaining the high editing precision of PE2. By enabling the precise incorporation of larger insertions, Exo-PE complements the growing palette of different PE tools and spurs additional refinements of the PE machinery.


Assuntos
Exonucleases , RNA Guia de Sistemas CRISPR-Cas , Linhagem Celular , DNA de Cadeia Simples/genética , Citometria de Fluxo , Edição de Genes , Sistemas CRISPR-Cas
2.
Anal Chem ; 95(26): 9881-9891, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37338819

RESUMO

A linear ion trap (LIT) is an affordable, robust mass spectrometer that provides fast scanning speed and high sensitivity, where its primary disadvantage is inferior mass accuracy compared to more commonly used time-of-flight or orbitrap (OT) mass analyzers. Previous efforts to utilize the LIT for low-input proteomics analysis still rely on either built-in OTs for collecting precursor data or OT-based library generation. Here, we demonstrate the potential versatility of the LIT for low-input proteomics as a stand-alone mass analyzer for all mass spectrometry (MS) measurements, including library generation. To test this approach, we first optimized LIT data acquisition methods and performed library-free searches with and without entrapment peptides to evaluate both the detection and quantification accuracy. We then generated matrix-matched calibration curves to estimate the lower limit of quantification using only 10 ng of starting material. While LIT-MS1 measurements provided poor quantitative accuracy, LIT-MS2 measurements were quantitatively accurate down to 0.5 ng on the column. Finally, we optimized a suitable strategy for spectral library generation from low-input material, which we used to analyze single-cell samples by LIT-DIA using LIT-based libraries generated from as few as 40 cells.


Assuntos
Proteômica , Espectrometria de Massas em Tandem , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos , Peptídeos/química
3.
J Proteome Res ; 21(11): 2815-2826, 2022 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-36287219

RESUMO

In recent years, the concept of cell heterogeneity in biology has gained increasing attention, concomitant with a push toward technologies capable of resolving such biological complexity at the molecular level. For single-cell proteomics using Mass Spectrometry (scMS) and low-input proteomics experiments, the sensitivity of an orbitrap mass analyzer can sometimes be limiting. Therefore, low-input proteomics and scMS could benefit from linear ion traps, which provide faster scanning speeds and higher sensitivity than an orbitrap mass analyzer, however at the cost of resolution. We optimized an acquisition method that combines the orbitrap and linear ion trap, as implemented on a tribrid instrument, while taking advantage of the high-field asymmetric waveform ion mobility spectrometry (FAIMS) pro interface, with a prime focus on low-input applications. First, we compared the performance of orbitrap- versus linear ion trap mass analyzers. Subsequently, we optimized critical method parameters for low-input measurement by data-independent acquisition on the linear ion trap mass analyzer. We conclude that linear ion traps mass analyzers combined with FAIMS and Whisper flow chromatography are well-tailored for low-input proteomics experiments, and can simultaneously increase the throughput and sensitivity of large-scale proteomics experiments where limited material is available, such as clinical samples and cellular subpopulations.


Assuntos
Peptídeos , Proteômica , Proteômica/métodos , Peptídeos/análise , Espectrometria de Massas/métodos , Espectrometria de Mobilidade Iônica
4.
bioRxiv ; 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36865114

RESUMO

A linear ion trap (LIT) is an affordable, robust mass spectrometer that proves fast scanning speed and high sensitivity, where its primary disadvantage is inferior mass accuracy compared to more commonly used time-of-flight (TOF) or orbitrap (OT) mass analyzers. Previous efforts to utilize the LIT for low-input proteomics analysis still rely on either built-in OTs for collecting precursor data or OT-based library generation. Here, we demonstrate the potential versatility of the LIT for low-input proteomics as a stand-alone mass analyzer for all mass spectrometry measurements, including library generation. To test this approach, we first optimized LIT data acquisition methods and performed library-free searches with and without entrapment peptides to evaluate both the detection and quantification accuracy. We then generated matrix-matched calibration curves to estimate the lower limit of quantification using only 10 ng of starting material. While LIT-MS1 measurements provided poor quantitative accuracy, LIT-MS2 measurements were quantitatively accurate down to 0.5 ng on column. Finally, we optimized a suitable strategy for spectral library generation from low-input material, which we used to analyze single-cell samples by LIT-DIA using LIT-based libraries generated from as few as 40 cells.

5.
Nat Commun ; 14(1): 5910, 2023 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-37737208

RESUMO

Single-cell resolution analysis of complex biological tissues is fundamental to capture cell-state heterogeneity and distinct cellular signaling patterns that remain obscured with population-based techniques. The limited amount of material encapsulated in a single cell however, raises significant technical challenges to molecular profiling. Due to extensive optimization efforts, single-cell proteomics by Mass Spectrometry (scp-MS) has emerged as a powerful tool to facilitate proteome profiling from ultra-low amounts of input, although further development is needed to realize its full potential. To this end, we carry out comprehensive analysis of orbitrap-based data-independent acquisition (DIA) for limited material proteomics. Notably, we find a fundamental difference between optimal DIA methods for high- and low-load samples. We further improve our low-input DIA method by relying on high-resolution MS1 quantification, thus enhancing sensitivity by more efficiently utilizing available mass analyzer time. With our ultra-low input tailored DIA method, we are able to accommodate long injection times and high resolution, while keeping the scan cycle time low enough to ensure robust quantification. Finally, we demonstrate the capability of our approach by profiling mouse embryonic stem cell culture conditions, showcasing heterogeneity in global proteomes and highlighting distinct differences in key metabolic enzyme expression in distinct cell subclusters.


Assuntos
Células-Tronco Embrionárias Murinas , Proteômica , Animais , Camundongos , Espectrometria de Massas , Proteoma , Análise de Célula Única
6.
Nat Cell Biol ; 24(11): 1666-1676, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36344775

RESUMO

Despite their fundamental role in assessing (patho)physiological cell states, conventional gene reporters can follow gene expression but leave scars on the proteins or substantially alter the mature messenger RNA. Multi-time-point measurements of non-coding RNAs are currently impossible without modifying their nucleotide sequence, which can alter their native function, half-life and localization. Thus, we developed the intron-encoded scarless programmable extranuclear cistronic transcript (INSPECT) as a minimally invasive transcriptional reporter embedded within an intron of a gene of interest. Post-transcriptional excision of INSPECT results in the mature endogenous RNA without sequence alterations and an additional engineered transcript that leaves the nucleus by hijacking the nuclear export machinery for subsequent translation into a reporter or effector protein. We showcase its use in monitoring interleukin-2 (IL2) after T cell activation and tracking the transcriptional dynamics of the long non-coding RNA (lncRNA) NEAT1 during CRISPR interference-mediated perturbation. INSPECT is a method for monitoring gene transcription without altering the mature lncRNA or messenger RNA of the target of interest.


Assuntos
RNA Longo não Codificante , Íntrons/genética , RNA Longo não Codificante/genética , RNA Longo não Codificante/metabolismo , Processamento Pós-Transcricional do RNA , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Sequência de Bases
7.
Nat Cell Biol ; 23(6): 652-663, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34083785

RESUMO

Expression of exon-specific isoforms from alternatively spliced mRNA is a fundamental mechanism that substantially expands the proteome of a cell. However, conventional methods to assess alternative splicing are either consumptive and work-intensive or do not quantify isoform expression longitudinally at the protein level. Here, we therefore developed an exon-specific isoform expression reporter system (EXSISERS), which non-invasively reports the translation of exon-containing isoforms of endogenous genes by scarlessly excising reporter proteins from the nascent polypeptide chain through highly efficient, intein-mediated protein splicing. We applied EXSISERS to quantify the inclusion of the disease-associated exon 10 in microtubule-associated protein tau (MAPT) in patient-derived induced pluripotent stem cells and screened Cas13-based RNA-targeting effectors for isoform specificity. We also coupled cell survival to the inclusion of exon 18b of FOXP1, which is involved in maintaining pluripotency of embryonic stem cells, and confirmed that MBNL1 is a dominant factor for exon 18b exclusion. EXSISERS enables non-disruptive and multimodal monitoring of exon-specific isoform expression with high sensitivity and cellular resolution, and empowers high-throughput screening of exon-specific therapeutic interventions.


Assuntos
Processamento Alternativo , Fatores de Transcrição Forkhead/metabolismo , Ensaios de Triagem em Larga Escala , Células-Tronco Pluripotentes Induzidas/metabolismo , Proteômica , Estabilidade de RNA , RNA Mensageiro/metabolismo , Proteínas de Ligação a RNA/metabolismo , Proteínas Repressoras/metabolismo , Proteínas tau/metabolismo , Sistemas CRISPR-Cas , Éxons , Fatores de Transcrição Forkhead/genética , Células HEK293 , Humanos , Isoformas de Proteínas , Proteoma , RNA Mensageiro/genética , Proteínas de Ligação a RNA/genética , Proteínas Repressoras/genética , Análise de Célula Única , Proteínas tau/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA