Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Bioinformatics ; 19(1): 123, 2018 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-29621971

RESUMO

BACKGROUND: Thanks to a reasonable cost and simple sample preparation procedure, linear MALDI-ToF spectrometry is a growing technology for clinical microbiology. With appropriate spectrum databases, this technology can be used for early identification of pathogens in body fluids. However, due to the low resolution of linear MALDI-ToF instruments, robust and accurate peak picking remains a challenging task. In this context we propose a new peak extraction algorithm from raw spectrum. With this method the spectrum baseline and spectrum peaks are processed jointly. The approach relies on an additive model constituted by a smooth baseline part plus a sparse peak list convolved with a known peak shape. The model is then fitted under a Gaussian noise model. The proposed method is well suited to process low resolution spectra with important baseline and unresolved peaks. RESULTS: We developed a new peak deconvolution procedure. The paper describes the method derivation and discusses some of its interpretations. The algorithm is then described in a pseudo-code form where the required optimization procedure is detailed. For synthetic data the method is compared to a more conventional approach. The new method reduces artifacts caused by the usual two-steps procedure, baseline removal then peak extraction. Finally some results on real linear MALDI-ToF spectra are provided. CONCLUSIONS: We introduced a new method for peak picking, where peak deconvolution and baseline computation are performed jointly. On simulated data we showed that this global approach performs better than a classical one where baseline and peaks are processed sequentially. A dedicated experiment has been conducted on real spectra. In this study a collection of spectra of spiked proteins were acquired and then analyzed. Better performances of the proposed method, in term of accuracy and reproductibility, have been observed and validated by an extended statistical analysis.


Assuntos
Algoritmos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Artefatos
2.
Biom J ; 60(2): 262-274, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29230881

RESUMO

Controlling the technological variability on an analytical chain is critical for biomarker discovery. The sources of technological variability should be modeled, which calls for specific experimental design, signal processing, and statistical analysis. Furthermore, with unbalanced data, the various components of variability cannot be estimated with the sequential or adjusted sums of squares of usual software programs. We propose a novel approach to variance component analysis with application to the matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) technology and use this approach for protein quantification by a classical signal processing algorithm and two more recent ones (BHI-PRO 1 and 2). Given the high technological variability, the quantification failed to restitute the known quantities of five out of nine proteins present in a controlled solution. There was a linear relationship between protein quantities and peak intensities for four out of nine peaks with all algorithms. The biological component of the variance was higher with BHI-PRO than with the classical algorithm (80-95% with BHI-PRO 1, 79-95% with BHI-PRO 2 vs. 56-90%); thus, BHI-PRO were more efficient in protein quantification. The technological component of the variance was higher with the classical algorithm than with BHI-PRO (6-25% vs. 2.5-9.6% with BHI-PRO 1 and 3.5-11.9% with BHI-PRO 2). The chemical component was also higher with the classical algorithm (3.6-18.7% vs. < 3.5%). Thus, BHI-PRO were better in removing noise from signal when the expected peaks are detected. Overall, either BHI-PRO algorithm may reduce the technological variance from 25 to 10% and thus improve protein quantification and biomarker validation.


Assuntos
Biometria/métodos , Proteínas/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Algoritmos , Análise de Variância , Biomarcadores/análise , Biomarcadores/química , Modelos Lineares , Proteínas/química
3.
Eur J Mass Spectrom (Chichester) ; 20(5): 351-60, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25707124

RESUMO

Among the needs usually expressed by teams using mass spectrometry imaging, one that often arises is that for user-friendly software able to manage huge data volumes quickly and to provide efficient assistance for the interpretation of data. To answer this need, the Computis European project developed several complementary software tools to process mass spectrometry imaging data. Data Cube Explorer provides a simple spatial and spectral exploration for matrix-assisted laser desorption/ionisation-time of flight (MALDI-ToF) and time of flight-secondary-ion mass spectrometry (ToF-SIMS) data. SpectViewer offers visualisation functions, assistance to the interpretation of data, classification functionalities, peak list extraction to interrogate biological database and image overlay, and it can process data issued from MALDI-ToF, ToF-SIMS and desorption electrospray ionisation (DESI) equipment. EasyReg2D is able to register two images, in American Standard Code for Information Interchange (ASCII) format, issued from different technologies. The collaboration between the teams was hampered by the multiplicity of equipment and data formats, so the project also developed a common data format (imzML) to facilitate the exchange of experimental data and their interpretation by the different software tools. The BioMap platform for visualisation and exploration of MALDI-ToF and DESI images was adapted to parse imzML files, enabling its access to all project partners and, more globally, to a larger community of users. Considering the huge advantages brought by the imzML standard format, a specific editor (vBrowser) for imzML files and converters from proprietary formats to imzML were developed to enable the use of the imzML format by a broad scientific community. This initiative paves the way toward the development of a large panel of software tools able to process mass spectrometry imaging datasets in the future.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Espectrometria de Massas/métodos , Software , Comportamento Cooperativo , Europa (Continente) , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Espectrometria de Massa de Íon Secundário
5.
N Biotechnol ; 33(3): 311-30, 2016 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-26514324

RESUMO

The REvolutionary Approaches and Devices for Nucleic Acid analysis (READNA) project received funding from the European Commission for 41/2 years. The objectives of the project revolved around technological developments in nucleic acid analysis. The project partners have discovered, created and developed a huge body of insights into nucleic acid analysis, ranging from improvements and implementation of current technologies to the most promising sequencing technologies that constitute a 3(rd) and 4(th) generation of sequencing methods with nanopores and in situ sequencing, respectively.


Assuntos
Biotecnologia/métodos , DNA/análise , DNA/genética , Animais , Química Click , Exoma/genética , Humanos , Espectrometria de Massas , Análise de Sequência de DNA
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA