Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Phys Rev Lett ; 129(21): 213201, 2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36461964

RESUMO

We report that flat substrates such as glass coverslips with surface roughness well below 0.5 nm feature notable speckle patterns when observed with high-sensitivity interference microscopy. We uncover that these speckle patterns unambiguously originate from the subnanometer surface undulations, and develop an intuitive model to illustrate how subnanometer nonresonant dielectric features could generate pronounced interference contrast in the far field. We introduce the concept of optical fingerprint for the deterministic speckle pattern associated with a particular substrate surface area and intentionally enhance the speckle amplitudes for potential applications. We demonstrate such optical fingerprints can be leveraged for reproducible position identification and marker-free lateral displacement detection with an experimental precision of 0.22 nm. The reproducible position identification allows us to detect new nanoscopic features developed during laborious processes performed outside of the microscope. The demonstrated capability for ultrasensitive displacement detection may find applications in the semiconductor industry and superresolution optical microscopy.


Assuntos
Microscopia
2.
Nat Methods ; 18(10): 1159-1160, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34608317
3.
Nano Lett ; 18(1): 513-519, 2018 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-29227108

RESUMO

Cellular secretion of proteins into the extracellular environment is an essential mediator of critical biological mechanisms, including cell-to-cell communication, immunological response, targeted delivery, and differentiation. Here, we report a novel methodology that allows for the real-time detection and imaging of single unlabeled proteins that are secreted from individual living cells. This is accomplished via interferometric detection of scattered light (iSCAT) and is demonstrated with Laz388 cells, an Epstein-Barr virus (EBV)-transformed B cell line. We find that single Laz388 cells actively secrete IgG antibodies at a rate of the order of 100 molecules per second. Intriguingly, we also find that other proteins and particles spanning ca. 100 kDa-1 MDa are secreted from the Laz388 cells in tandem with IgG antibody release, likely arising from EBV-related viral proteins. The technique is general and, as we show, can also be applied to studying the lysate of a single cell. Our results establish label-free iSCAT imaging as a powerful tool for studying the real-time exchange between cells and their immediate environment with single-protein sensitivity.


Assuntos
Linfócitos B/imunologia , Infecções por Vírus Epstein-Barr/imunologia , Herpesvirus Humano 4/imunologia , Imunoglobulina G/análise , Análise de Célula Única/métodos , Linfócitos B/virologia , Linhagem Celular , Herpesvirus Humano 4/isolamento & purificação , Humanos , Imunoglobulina G/imunologia , Luz , Microscopia de Interferência/métodos , Imagem Óptica/métodos , Espalhamento de Radiação
4.
Opt Express ; 20(1): 672-80, 2012 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-22274391

RESUMO

We report on a new biosensor with localized surface plasmons (LSP) based on an array of gold nanorods and the total internal reflection imaging in polarization contrast. The sensitivity of the new biosensor is characterized and a model detection of DNA hybridization is carried out. The results are compared with a reference experiment using a conventional high-resolution surface plasmon resonance (SPR) biosensor. We show that the LSP-based biosensor delivers the same performance as the SPR system while involving significantly lower surface densities of interacting molecules. We demonstrate a limit of detection of 100 pM and a surface density resolution of only 35 fg×mm-2 that corresponds to less than one DNA molecule per nanoparticle on average.


Assuntos
Técnicas Biossensoriais/instrumentação , DNA/análise , DNA/genética , Desenho de Equipamento , Hibridização In Situ/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Análise de Falha de Equipamento
5.
Opt Express ; 19(10): 9213-20, 2011 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-21643175

RESUMO

We report on an experimental characterization of the sensitivity of localized surface plasmons (LSP) to local changes in the refractive index at a nanometer scale. The method is based on forming a polymer mask covering different well defined areas of metallic nanoparticles and measuring the extinction peak shifts associated with the local refractive index changes. Arrays of nanoparticles (nanorod chains) are prepared using electron beam lithography and the dielectric mask is aligned with respect to the nanoparticle array in a second lithographic step. Extinction peak shifts corresponding to different positions of the mask are measured and values for the local refractive index sensitivity are deduced. A deconvolution procedure is established and used to map the local sensitivity across the surface of nanoparticle based on measured data. The experimental results are shown to correspond well with theoretical simulations obtained using the finite-difference time-domain method. The results indicate that the sensitivity is strongly correlated with the profile of the LSP electric field.

6.
Small Methods ; 5(4): e2000985, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-34927839

RESUMO

Microtubules are cytoskeletal polymers of tubulin dimers assembled into protofilaments that constitute nanotubes undergoing periods of assembly and disassembly. Static electron micrographs suggest a structural transition of straight protofilaments into curved ones occurring at the tips of disassembling microtubules. However, these structural transitions have never been observed and the process of microtubule disassembly thus remains unclear. Here, label-free optical microscopy capable of selective imaging of the transient structural changes of protofilaments at the tip of a disassembling microtubule is introduced. Upon induced disassembly, the transition of ordered protofilaments into a disordered conformation is resolved at the tip of the microtubule. Imaging the unbinding of individual tubulin oligomers from the microtubule tip reveals transient pauses and relapses in the disassembly, concurrent with increased organization of protofilament segments at the microtubule tip. These findings show that microtubule disassembly is a discrete process and suggest a stochastic mechanism of switching from the disassembly to the assembly phase.


Assuntos
Microscopia/métodos , Microtúbulos/química , Polímeros/análise , Conformação Proteica , Tubulina (Proteína)
7.
Small Methods ; 5(10): e2100370, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34927934

RESUMO

Diffusion is the most fundamental mode of protein translocation within cells. Confined diffusion of proteins along the electrostatic potential constituted by the surface of microtubules, although modeled meticulously in molecular dynamics simulations, has not been experimentally observed in real-time. Here, interferometric scattering microscopy is used to directly visualize the movement of the microtubule-associated protein Ase1 along the microtubule surface at nanometer and microsecond resolution. Millisecond confinements of Ase1 and fast leaps between these positions of dwelling preferentially occurring along the microtubule protofilaments are resolved, revealing Ase1's mode of diffusive translocation along the microtubule's periodic surface. The derived interaction potential closely matches the tubulin-dimer periodicity and the distribution of the electrostatic potential on the microtubule lattice. It is anticipated that mapping the interaction landscapes for different proteins on microtubules, finding plausible energetic barriers of different positioning and heights, can provide valuable insights into regulating the dynamics of essential cytoskeletal processes, such as intracellular cargo trafficking, cell division, and morphogenesis, all of which rely on diffusive translocation of proteins along microtubules.


Assuntos
Proteínas Associadas aos Microtúbulos/química , Proteínas Associadas aos Microtúbulos/metabolismo , Microtúbulos/metabolismo , Animais , Divisão Celular , Simulação de Dinâmica Molecular , Domínios Proteicos , Transporte Proteico , Imagem Individual de Molécula , Análise Espaço-Temporal , Suínos
8.
Nat Commun ; 12(1): 2921, 2021 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-34012021

RESUMO

Spatial light modulators have become an essential tool for advanced microscopy, enabling breakthroughs in 3D, phase, and super-resolution imaging. However, continuous spatial-light modulation that is capable of capturing sub-millisecond microscopic motion without diffraction artifacts and polarization dependence is challenging. Here we present a photothermal spatial light modulator (PT-SLM) enabling fast phase imaging for nanoscopic 3D reconstruction. The PT-SLM can generate a step-like wavefront change, free of diffraction artifacts, with a high transmittance and a modulation efficiency independent of light polarization. We achieve a phase-shift > π and a response time as short as 70 µs with a theoretical limit in the sub microsecond range. We used the PT-SLM to perform quantitative phase imaging of sub-diffractional species to decipher the 3D nanoscopic displacement of microtubules and study the trajectory of a diffusive microtubule-associated protein, providing insights into the mechanism of protein navigation through a complex microtubule network.


Assuntos
Microscopia de Contraste de Fase/métodos , Proteínas de Ciclo Celular/metabolismo , Simulação por Computador , Ouro , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/estatística & dados numéricos , Luz , Nanopartículas Metálicas/ultraestrutura , Microscopia de Força Atômica , Microscopia de Interferência/métodos , Microscopia de Interferência/estatística & dados numéricos , Microscopia de Contraste de Fase/estatística & dados numéricos , Proteínas Associadas aos Microtúbulos/metabolismo , Microtúbulos/metabolismo , Microtúbulos/ultraestrutura , Nanotecnologia , Nanotubos/ultraestrutura , Fenômenos Ópticos , Proteínas de Schizosaccharomyces pombe/metabolismo , Fatores de Tempo , Tubulina (Proteína)/metabolismo
9.
Anal Bioanal Chem ; 398(5): 1955-61, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20824425

RESUMO

We report a novel approach to biosensor-based observations of biomolecular interactions which enables real-time monitoring of biomolecular interactions in complex media. This approach is demonstrated by investigating the interaction between the human chorionic gonadotropin (hCG) and its antibody in blood plasma using a surface plasmon resonance biosensor and a dispersionless microfluidics system. The real-time binding data obtained in blood plasma are compared with those obtained in buffer and blood plasma using a conventional method. It is also demonstrated that the proposed approach can enhance the capability of the biosensor to detect biomolecules in complex samples in terms of detection time and sensitivity. In the model experiment, this approach is shown to enable direct detection of hCG in blood plasma at levels which are five times lower than those detected using the conventional detection approach.


Assuntos
Anticorpos/química , Gonadotropina Coriônica/sangue , Microfluídica , Ressonância de Plasmônio de Superfície/métodos , Técnicas Biossensoriais/métodos , Gonadotropina Coriônica/química , Humanos
10.
Opt Express ; 17(19): 16505-17, 2009 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-19770865

RESUMO

We report on a unified theoretical model of the resolution of SPR sensors which makes it possible to predict the ultimate performance of all major configurations of SPR sensors. The theory indicates that the performance of SPR sensors is independent of the method of excitation of surface plasmons (prism or grating coupling) or the method of modulation (amplitude, angular or wavelength) and depends dominantly on the noise properties of the light source and detector. Results of the theoretical analysis are compared with the performance reported for several SPR sensors to illustrate that the best state-of-art SPR sensors are approaching their theoretical limits. Possibilities for further advances in the performance of SPR sensor technology are discussed.

11.
Methods Mol Biol ; 503: 65-88, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19151937

RESUMO

Surface plasmon resonance (SPR) biosensors belong to label-free optical biosensing technologies. The SPR method is based on optical measurement of refractive index changes associated with the binding of analyte molecules in a sample to biorecognize molecules immobilized on the SPR sensor. Since late 1990's, SPR biosensors have become the main tool for the study of biomolecular interactions both in life science and pharmaceutical research. In addition, they have been increasingly applied in the detection of chemical and biological substances in important areas such as medical diagnostics, environmental monitoring, food safety and security. This chapter reviews the main principles of SPR biosensor technology and discusses applications of this technology for rapid, sensitive and specific detection of chemical and biological analytes.


Assuntos
Bioensaio/instrumentação , Técnicas Biossensoriais/instrumentação , Imunoensaio/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Bioensaio/métodos , Técnicas Biossensoriais/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Imunoensaio/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ressonância de Plasmônio de Superfície/métodos
12.
Anal Bioanal Chem ; 393(4): 1157-63, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18958451

RESUMO

In this work, we present an antibody array for the detection of cancer biomarker candidates by a surface plasmon resonance (SPR) imaging sensor with polarization contrast. Responses from the SPR imaging sensor are shown to be similar to those from a conventional spectroscopy-based SPR sensor. Antibodies are spotted onto a self-assembled monolayer (SAM) composed of oligo(ethylene glycol) (OEG)-containing alkanethiol chains. Detection of two cancer biomarker candidates, activated leukocyte cell adhesion molecule/CD 166 (ALCAM) and transgelin-2 (TAGLN2), is demonstrated. Limits of detection for ALCAM and TAGLN2 are established at 6 ng/mL and 3 ng/mL, respectively, in buffer. No cross-reactivity is observed between immobilized antibodies and nonspecific antigen. Biomarker candidates are also detected in a 10% human serum solution.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias/diagnóstico , Ressonância de Plasmônio de Superfície/métodos , Calibragem , Humanos , Sensibilidade e Especificidade
13.
Anal Chem ; 80(11): 4231-6, 2008 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-18457413

RESUMO

In this work, we present a novel surface and assay for the simultaneous detection of DNA and protein analytes on a surface plasmon resonance (SPR) imaging sensor. A mixed DNA/oligo (ethylene glycol) (OEG) self-assembled monolayer (SAM) is created using a microarrayer. Thiol-modified single-stranded DNA sequences are spotted onto a gold-coated glass substrate. Backfilling with an OEG-modified alkanethiol creates a protein-resistant surface background. Antibodies conjugated to complementary single-stranded DNA sequences are immobilized on the surface through DNA hybridization. By converting only part of the DNA array into a protein array, simultaneous detections of DNA and protein analytes are possible. A model system of two cDNA sequences and two human pregnancy hormones are used to demonstrate the assay. No cross-reactivity was observed between DNA or protein analytes and nontargeted immobilized cDNA sequence or antibodies. A response from a detection of a single analyte in a mixture of protein and DNA analytes corresponds well with that of a single-analyte solution.


Assuntos
DNA/análise , Proteínas/análise , Ressonância de Plasmônio de Superfície/métodos , Anticorpos/química , Gonadotropina Coriônica/análise , Gonadotropina Coriônica/química , DNA/química , Hormônio Foliculoestimulante/análise , Hormônio Foliculoestimulante/química , Humanos , Análise de Sequência com Séries de Oligonucleotídeos , Análise Serial de Proteínas , Proteínas/química , Compostos de Sulfidrila/química
14.
Anal Chem ; 80(20): 7894-901, 2008 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-18808152

RESUMO

A crucial step in the development of implanted medical devices, in vivo diagnostics, and microarrays is the effective prevention of nonspecific protein adsorption from real-world complex media such as blood plasma or serum. In this work, a zwitterionic poly(carboxybetaine acrylamide) (polyCBAA) biomimetic material was employed to create a unique biorecognition coating with an ultralow fouling background, enabling the sensitive and specific detection of proteins in blood plasma. Conditions for surface activation, protein immobilization, and surface deactivation of the carboxylate groups in the polyCBAA coating were determined. An antibody-functionalized polyCBAA surface platform was used to detect a target protein in blood plasma using a sensitive surface plasmon resonance (SPR) sensor. A selective protein was directly detected from 100% human blood plasma with extraordinary specificity and sensitivity. The total nonspecific protein adsorption on the functionalized polyCBAA surface was very low (<3 ng/cm (2) for undiluted blood plasma). Because of the significant reduction of nonspecific protein adsorption, it was possible to monitor the kinetics of antigen-antibody interactions in undiluted blood plasma. The functionalization effectiveness and detection characteristics using a cancer protein marker candidate of polyCBAA were compared with those of the conventional nonfouling oligo(ethylene glycol)-based surface chemistry.


Assuntos
Acrilamidas/química , Proteínas Sanguíneas/análise , Polímeros/química , Acrilamidas/metabolismo , Adsorção , Anticorpos/imunologia , Materiais Biomiméticos/química , Materiais Biomiméticos/metabolismo , Proteínas Sanguíneas/metabolismo , Humanos , Hidrólise , Polímeros/metabolismo , Sensibilidade e Especificidade , Propriedades de Superfície
15.
Biosens Bioelectron ; 22(6): 1020-6, 2007 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16797175

RESUMO

This paper describes the direct label-free detection of antibodies against the Epstein-Barr virus (anti-EBNA) using a surface plasmon resonance (SPR) biosensor. The antibody detection was performed using the immunoreaction between anti-EBNA and a respective synthetic peptide (EBNA-1), which was conjugated with bovine serum albumin (BSA-EBNA) and immobilized on the sensor surface. Three immobilization chemistries for the attachment of BSA-EBNA were investigated to optimize ligand density and minimize loss of EBNA-1 immunoreactivity. The developed SPR biosensor functionalized with the optimal immobilization method was calibrated and characterized in terms of detection limit, reproducibility, regenerability and storability. It was demonstrated that the sensor is capable of detecting concentrations of anti-EBNA as low as 0.2 ng/ml (approximately 1 pM) both in buffer and 1% human serum and can be stored and regenerated for repeated use.


Assuntos
Anticorpos/análise , Anticorpos/imunologia , Técnicas Biossensoriais/instrumentação , Antígenos Nucleares do Vírus Epstein-Barr/análise , Antígenos Nucleares do Vírus Epstein-Barr/imunologia , Herpesvirus Humano 4/imunologia , Imunoensaio/instrumentação , Técnicas Biossensoriais/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Imunoensaio/métodos
16.
Biosens Bioelectron ; 20(10): 2104-10, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15741081

RESUMO

We report a new high-throughput surface plasmon resonance (SPR) sensor based on combination of SPR imaging with polarization contrast and a spatially patterned multilayer SPR structure. We demonstrate that this approach offers numerous advantageous features including high-contrast SPR images suitable for automated computer analysis, minimum crosstalk between neighboring sensing channels and inherent compensation for light level fluctuations. Applications of a laboratory prototype of the high-throughput SPR sensor with 108 sensing channels for refractometry and biosensing are described. In refractometric experiments, the noise-limited refractive index resolution of the system has been established to be 3 x 10(-6) refractive index unit (RIU). Experimental data on detection of human choriogonadotropin (hCG) suggest that in conjunction with monoclonal antibodies against hCG, the reported SPR imaging sensor is capable of detecting hCG at concentrations lower than 500 ng/ml.


Assuntos
Técnicas Biossensoriais/instrumentação , Gonadotropina Coriônica/análise , Imunoensaio/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Refratometria/instrumentação , Robótica/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Técnicas Biossensoriais/métodos , Gonadotropina Coriônica/imunologia , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imunoensaio/métodos , Técnicas Analíticas Microfluídicas/métodos , Refratometria/métodos , Robótica/métodos , Ressonância de Plasmônio de Superfície/métodos
17.
Nat Commun ; 5: 4495, 2014 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-25072241

RESUMO

Detection of single analyte molecules without the use of any label would improve the sensitivity of current biosensors by orders of magnitude to the ultimate graininess of biological matter. Over two decades, scientists have succeeded in pushing the limits of optical detection to single molecules using fluorescence. However, restrictions in photophysics and labelling protocols make this technique less attractive for biosensing. Recently, mechanisms based on vibrational spectroscopy, photothermal detection, plasmonics and microcavities have been explored for fluorescence-free detection of single biomolecules. Here, we show that interferometric detection of scattering (iSCAT) can achieve this goal in a direct and label-free fashion. In particular, we demonstrate detection of cancer marker proteins in buffer solution and in the presence of other abundant proteins. Furthermore, we present super-resolution imaging of protein binding with nanometer localization precision. The ease of iSCAT instrumentation promises a breakthrough for label-free studies of interactions involving proteins and other small biomolecules.


Assuntos
Sítios de Ligação/genética , Biomarcadores Tumorais/genética , Técnicas Biossensoriais/métodos , Microscopia de Interferência/métodos , Proteínas/ultraestrutura , Técnicas Biossensoriais/tendências , Proteínas/genética
18.
Biosens Bioelectron ; 26(4): 1656-61, 2010 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-20864329

RESUMO

Surface plasmon resonance (SPR) biosensor for high-throughput screening of protein biomarkers in diluted blood plasma is reported. The biosensor combines a high-resolution SPR imaging sensor and a high-density protein array with low-fouling background. The SPR imaging sensor utilizes polarization contrast and advanced referencing and provides a total of 120 sensing areas (each 200 µm×150 µm). Antibodies are immobilized on the sensing areas via hybridization of antibody-oligonucleotide conjugates to thiolated complementary oligonucleotides microspotted on the sensor surface (DNA-directed immobilization). A low-fouling background is achieved by covalent immobilization of bovine serum albumin to carboxyl-terminated thiols filling the areas among the thiolated oligonucleotides and outside the sensing areas. The biosensor was evaluated for detection of protein biomarkers relevant to cancer diagnostics--human chorionic gonadotropin (hCG) and activated leukocyte cell adhesion molecule (ALCAM) both in buffer and in 10% blood plasma. Limits of detection as low as 45 ng/mL (ALCAM) and 100 ng/mL (hCG) were achieved in blood plasma samples.


Assuntos
Biomarcadores/sangue , Proteínas Sanguíneas/análise , Ressonância de Plasmônio de Superfície/instrumentação , Animais , Anticorpos Imobilizados , Antígenos CD/sangue , Biomarcadores Tumorais/sangue , Bovinos , Moléculas de Adesão Celular Neuronais/sangue , Gonadotropina Coriônica/sangue , Desenho de Equipamento , Proteínas Fetais , Humanos , Proteínas Imobilizadas , Limite de Detecção , Neoplasias/sangue , Neoplasias/diagnóstico , Oligonucleotídeos , Refratometria , Soroalbumina Bovina , Ressonância de Plasmônio de Superfície/métodos , Ressonância de Plasmônio de Superfície/estatística & dados numéricos , Tionucleotídeos
19.
Biosens Bioelectron ; 25(10): 2276-82, 2010 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-20359880

RESUMO

Non-specific protein binding from human plasma and serum has severely hindered the full capabilities of biosensors concerned with cancer biomarker detection. Currently, there is a strong desire for developing new materials which allow for the convenient attachment of an ultra-low fouling and functionalizable surface coating which can be used for highly sensitive and label-free detection of target analytes directly from complex media. In this work, a short 20 min in situ "graft to" protocol using Tris pH 8.5 buffer was developed for zwitterionic carboxybetaine methacrylate (CBMA) polymer conjugates containing the adhesive biomimetic moiety, 3,4-dihydroxy-L-phenylalanine (DOPA), on SiO(2) substrates. Using a surface plasmon resonance (SPR) biosensor, different buffers, pH values, salt concentrations, and temperatures were investigated for determining the "graft to" conditions that yield dense polymer films which both minimize non-specific protein adsorption and maximize antibody immobilization. The optimized surface coatings were shown to be highly protein resistant to 100% human blood plasma and serum. Subsequent antibody functionalized surfaces without any blocking agents enabled the specific detection of the cancer biomarker ALCAM directly from undiluted human serum down to 64 ng/mL. The successful use of this zwitterionic surface coating for detection from complex media on SiO(2) surfaces indicates its potential for broad impacts in the development of implantable medical devices, in vivo diagnostics, and nano-scale biosensors.


Assuntos
Antígenos CD/sangue , Materiais Biomiméticos/química , Técnicas Biossensoriais/instrumentação , Análise Química do Sangue/instrumentação , Moléculas de Adesão Celular Neuronais/sangue , Dióxido de Silício/química , Ressonância de Plasmônio de Superfície/instrumentação , Adesivos/química , Materiais Revestidos Biocompatíveis/química , Desenho de Equipamento , Análise de Falha de Equipamento , Proteínas Fetais , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Propriedades de Superfície
20.
Biosens Bioelectron ; 26(4): 1231-8, 2010 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-20637590

RESUMO

Techniques for immunosensing like surface plasmon resonance (SPR) may respond to the need for rapid screening methods to improve food safety. This paper describes the development of a novel portable six channel SPR biosensor based on the plasmon of gold diffraction grating surface for simultaneous multianalyte antibiotic detection in milk samples. Representative congeners from three important antibiotic families (FQs: fluoroquinolones, SAs: sulfonamides and CAP: phenicols) were chosen for this study. The chips are covalently biofunctionalized with haptenized proteins by means of a previously formed mixed self assembled monolayer (m-SAM) prepared using two types of mercapto alkyl reagents containing polyethyleneglycol (PEG) units. The samples or standards are mixed with specific polyclonal antibodies and injected into the sensor device. The detectability accomplished is very good (i.e. in buffer, enrofloxacin, 0.30 µg L(-1); sulfapyridine, 0.29 µg L(-1); and chloramphenicol, 0.26 µg L(-1)) and whole milk samples can be analyzed directly without clean-up steps, by just diluting the sample five times with water to remove non-specific interferences caused by the matrix. Although the detectability of CAP regarding the MRPL (minimum required performance limit) is slightly compromised by the dilution, the detectability accomplished by FQs and SAs was far below the maximum residue levels (MRLs) established by the European Union.


Assuntos
Antibacterianos/análise , Contaminação de Alimentos/análise , Leite/química , Ressonância de Plasmônio de Superfície/instrumentação , Animais , Cloranfenicol/análise , Enrofloxacina , Desenho de Equipamento , Fluoroquinolonas/análise , Inocuidade dos Alimentos , Dispositivos Lab-On-A-Chip , Sulfapiridina/análise , Ressonância de Plasmônio de Superfície/métodos , Ressonância de Plasmônio de Superfície/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA