Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 28(24): 36723-36739, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33379760

RESUMO

An adaptive optics optical coherence tomography (AO-OCT) system is used to assess sixty healthy eyes of thirty subjects (age 22 to 75) to evaluate how the outer retinal layers, foveal eccentricity and age effect the mean cone density. The cone mosaics of different retinal planes (the cone inner segment outer segment junction (IS/OS), the cone outer segment combined with the IS/OS (ISOS+), the cone outer segment tips (COST), and the full en-face plane (FEF)) at four main meridians (superior, nasal, inferior, temporal) and para- and perifoveal eccentricities (ecc 2.5° and 6.5°) were analyzed quantitatively. The mean overall cone density was 19,892/mm2 at ecc 2.5° and 13,323/mm2 at ecc 6.5°. A significant impact on cone density was found for eccentricity (up to 6,700/mm2 between ecc 2.5° and 6.5°), meridian (up to 3,700/mm2 between nasal and superior meridian) and layer (up to 1,400/mm2 between FEF and IS/OS). Age showed only a weak negative effect. These factors as well as inter-individual variability have to be taken into account when comparing cone density measurements between healthy and pathologically changed eyes, as their combined effect on density can easily exceed several thousand cones per mm2 even in parafoveal regions.


Assuntos
Envelhecimento/fisiologia , Fóvea Central/diagnóstico por imagem , Imageamento Tridimensional/métodos , Células Fotorreceptoras Retinianas Cones/citologia , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Contagem de Células , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Estudos Prospectivos , Acuidade Visual/fisiologia , Campos Visuais/fisiologia , Adulto Jovem
2.
Retina ; 39(3): 465-472, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29360686

RESUMO

PURPOSE: To characterize retinal microaneurysms (MAs) in patients with diabetes using adaptive optics optical coherence tomography (AOOCT) and compare details found in AOOCT with those found in commercially available retinal imaging techniques. METHODS: Patients with diabetes and MA in the macular area were included in this pilot study. The area of interest, identified in standard fluorescein angiography, was imaged using an AO fundus camera and AOOCT. Microaneurysms were characterized in AOOCT (visibility, reflectivity, feeding/draining vessels, and intraretinal location) and compared with findings in AO fundus camera, OCT angiography, and fluorescein angiography. RESULTS: Fifty-three MAs were imaged in 15 eyes of 10 patients. Feeding and/or draining vessels from both capillary plexus could be identified in 34 MAs in AOOCT images. Of 45 MAs imaged with OCT angiography, 18 (40%) were visible in the superior plexus, 12 (27%) in the deep capillary plexus, and 15 MAs (33%) could not be identified at all. Intraluminal hyperreflectivity, commonly seen in AO fundus camera, corresponded only in 8 of 27 cases (30%) to intraluminal densities seen in AOOCT. CONCLUSION: Adaptive optics OCT imaging revealed that MAs located in the inner nuclear layer were connected to the intermediate and/or deep capillary plexus. Intraluminal hyperreflectivity seen on AO fundus camera images originated from a strong reflection from the vessel wall and only in a third of the cases from intraluminal clots. Currently, AOOCT is the most expedient in vivo imaging method to capture morphologic details of retinal microvasculature in 3D and in the context of the surrounding retinal anatomy.


Assuntos
Retinopatia Diabética/diagnóstico por imagem , Imageamento Tridimensional/métodos , Microaneurisma/diagnóstico por imagem , Vasos Retinianos/patologia , Tomografia de Coerência Óptica/métodos , Idoso , Estudos Transversais , Feminino , Angiofluoresceinografia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
3.
Retina ; 39(3): 558-569, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29215532

RESUMO

PURPOSE: To examine the involvement of the retinal pigment epithelium (RPE) in the presence of vitelliform macular lesions (VML) in Best vitelliform macular dystrophy (BVMD), autosomal recessive bestrophinopathy, and adult-onset vitelliform macular degeneration using polarization-sensitive optical coherence tomography (PS-OCT). METHODS: A total of 35 eyes of 18 patients were imaged using a PS-OCT system and blue light fundus autofluorescence imaging. Pathogenic mutations in the BEST1 gene, 3 of which were new, were detected in all patients with BVMD and autosomal recessive bestrophinopathy. RESULTS: Polarization-sensitive optical coherence tomography showed a characteristic pattern in all three diseases with nondepolarizing material in the subretinal space consistent with the yellowish VML seen on funduscopy with a visible RPE line below it. A focal RPE thickening was seen in 26 eyes under or at the edge of the VML. Retinal pigment epithelium thickness outside the VML was normal or mildly thinned in patients with BVMD and adult-onset vitelliform macular degeneration but was diffusely thinned or atrophic in patients with autosomal recessive bestrophinopathy. Patients with autosomal recessive bestrophinopathy showed sub-RPE fibrosis alongside the subretinal VML. Polarization-sensitive optical coherence tomography was more reliable in assessing the localization and the integrity of the RPE than spectral domain OCT alone. On spectral domain OCT, identification of the RPE was not possible in 19.4% of eyes. Polarization-sensitive optical coherence tomography allowed for definite identification of the location of VML in respect to the RPE in all eyes, since it provides a tissue-specific contrast. CONCLUSION: Polarization-sensitive optical coherence tomography confirms in vivo the subretinal location of VML and is useful in the assessment of RPE integrity.


Assuntos
Distrofia Macular Viteliforme/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Angiofluoresceinografia/métodos , Humanos , Macula Lutea/patologia , Masculino , Pessoa de Meia-Idade , Epitélio Pigmentado da Retina/patologia , Tomografia de Coerência Óptica/métodos , Adulto Jovem
4.
Retina ; 34(11): 2208-17, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25046395

RESUMO

PURPOSE: To investigate pigmentation characteristics of the retinal pigment epithelium (RPE) in patients with albinism using wide-field polarization-sensitive optical coherence tomography compared with intensity-based spectral domain optical coherence tomography and fundus autofluorescence imaging. METHODS: Five patients (10 eyes) with previously genetically diagnosed albinism and 5 healthy control subjects (10 eyes) were imaged by a wide-field polarization-sensitive optical coherence tomography system (scan angle: 40 × 40° on the retina), sensitive to melanin contained in the RPE, based on the polarization state of backscattered light. Conventional intensity-based spectral domain optical coherence tomography and fundus autofluorescence examinations were performed. Retinal pigment epithelium-pigmentation was analyzed qualitatively and quantitatively based on depolarization assessed by polarization-sensitive optical coherence tomography. RESULTS: This study revealed strong evidence of polarization-sensitive optical coherence tomography to specifically image melanin in the RPE. Depolarization of light backscattered by the RPE in patients with albinism was reduced compared with normal subjects. Heterogeneous RPE-specific depolarization characteristics were observed in patients with albinism. Reduction of depolarization observed in the light backscattered by the RPE in patients with albinism corresponds to expected decrease of RPE pigmentation. The degree of depigmentation of the RPE is possibly associated with visual acuity. Findings suggest that different albinism genotypes result in heterogeneous levels of RPE pigmentation. CONCLUSION: Polarization-sensitive optical coherence tomography showed a heterogeneous appearance of RPE pigmentation in patients with albinism depending on different genotypes.


Assuntos
Albinismo/patologia , Epitélio Pigmentado da Retina/patologia , Tomografia de Coerência Óptica/instrumentação , Adulto , Albinismo/fisiopatologia , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Melaninas/análise , Pessoa de Meia-Idade , Fenótipo , Tomografia de Coerência Óptica/métodos , Acuidade Visual/fisiologia , Adulto Jovem
5.
J Clin Med ; 13(4)2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38398387

RESUMO

Purpose: To assess retinal function in areas of presumed fibrosis due to neovascular age-related macular degeneration (nAMD), using multimodal imaging and structure-function correlation. Design: Cross-sectional observational study. Methods: 30 eyes of 30 consecutive patients with nAMD with a minimum history of one year of anti-vascular endothelial growth factor therapy were included. Each patient underwent microperimetry (MP), color fundus photography (CFP), standard spectral-domain-based OCT (SD-OCT), and polarization sensitive-OCT (PS-OCT) imaging. PS-OCT technology can depict retinal fibrosis based on its birefringence. CFP, SD-OCT, and PS-OCT were evaluated independently for the presence of fibrosis at the corresponding MP stimuli locations. MP results and morphologic findings in CFP, SD-OCT, and PS-OCT were co-registered and analyzed using mixed linear models. Results: In total, 1350 MP locations were evaluated to assess the functional impact of fibrosis according to a standardized protocol. The estimated means of retinal areas with signs of fibrosis were 12.60 db (95% confidence interval: 10.44-14.76) in CFP, 11.60 db (95% COI: 8.84-14.36) in OCT, and 11.02 db (95% COI 8.10-13.94) in PS-OCT. Areas evaluated as subretinal fibrosis in three (7.2 db) or two (10.1 db) modalities were significantly correlated with a lower retinal sensitivity than a subretinal fibrosis observed in only one (15.3 db) or none (23.3 db) modality (p < 0.001). Conclusions: CFP, SD-OCT and PS-OCT are all suited to detect areas of reduced retinal sensitivity related to fibrosis, however, a multimodal imaging approach provides higher accuracy in the identification of areas with low sensitivity in MP (i.e., impaired retinal function), and thereby improves the detection rate of subretinal fibrosis in nAMD.

6.
Eye Vis (Lond) ; 11(1): 30, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39004731

RESUMO

BACKGROUND: Accurately assessing corneal structural status is challenging when thickness deviates from the average. Polarization-sensitive optical coherence tomography (PS-OCT) measures tissue-specific polarization changes, providing additional contrast for accurate segmentations and aids in phase retardation (PR) measurements. Previous studies have shown PR's effectiveness in identifying sub-clinical keratoconus (KC) in asymmetric cases. Thus, this study aims to assess PR distribution in thick corneas with and without KC. METHODS: In this retrospective and cross-sectional study, 45 thick corneas from 30 Asian-Indian subjects, categorized into healthy (n = 26) and KC (n = 19) groups were analyzed. All eyes underwent standard clinical evaluations, tomographic assessments, and corneal biomechanics measurements. PR and individual layer thicknesses were measured using custom-designed ultrahigh-resolution PS-OCT. PR en-face maps were generated. Individual layer thicknesses and PR analysis was conducted across multiple zones, extending up to 8-10 mm in diameter. All eyes in the study had not undergone interventions, received topical medications, or had previous corneal disease history. RESULTS: Significant differences were found in spherical and cylindrical powers, keratometry, pachymetry, and biomechanical indices (all P < 0.01). Thickness profiles from PS-OCT showed significant differences in the 4-8 mm zones only. Bowman's layer thickness significantly differed only in the central 2 mm zone (P = 0.02). The median PR values showed marginal differences in the central 2 mm zone (P = 0.0565). Additionally, there were significant differences observed in the 2-4 mm and 4-6 mm zones (P = 0.0274 and P = 0.0456, respectively). KC eyes exhibited an atypical PR distribution and corneal thinning, while normal eyes maintained a uniform Bowman's layer thickness and PR maps with larger areas of higher PR. CONCLUSION: The study revealed distinctive PR distribution in thick corneas among healthy and KC groups. Using an ultrahigh-resolution PS-OCT the significance of Bowman's layer thickness in these groups was also emphasized. The study offered potential improvements in clinical diagnostics by enhancing our understanding of corneal structure and its altered function.

7.
Sci Rep ; 14(1): 13450, 2024 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-38862584

RESUMO

This study tested if a high-resolution, multi-modal, multi-scale retinal imaging instrument can provide novel information about structural abnormalities in vivo. The study examined 11 patients with very mild to moderate non-proliferative diabetic retinopathy (NPDR) and 10 healthy subjects using fundus photography, optical coherence tomography (OCT), OCT angiography (OCTA), adaptive optics scanning laser ophthalmoscopy (AO-SLO), adaptive optics OCT and OCTA (AO-OCT(A)). Of 21 eyes of 11 patients, 11 had very mild NPDR, 8 had mild NPDR, 2 had moderate NPDR, and 1 had no retinopathy. Using AO-SLO, capillary looping, inflections and dilations were detected in 8 patients with very mild or mild NPDR, and microaneurysms containing hyperreflective granular elements were visible in 9 patients with mild or moderate NPDR. Most of the abnormalities were seen to be perfused in the corresponding OCTA scans while a few capillary loops appeared to be occluded or perfused at a non-detectable flow rate, possibly because of hypoperfusion. In one patient with moderate NPDR, non-perfused capillaries, also called ghost vessels, were identified by alignment of corresponding en face AO-OCT and AO-OCTA images. The combination of multiple non-invasive imaging methods could identify prominent microscopic abnormalities in diabetic retinopathy earlier and more detailed than conventional fundus imaging devices.


Assuntos
Capilares , Retinopatia Diabética , Oftalmoscopia , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Retinopatia Diabética/diagnóstico por imagem , Retinopatia Diabética/patologia , Feminino , Masculino , Oftalmoscopia/métodos , Pessoa de Meia-Idade , Capilares/diagnóstico por imagem , Capilares/patologia , Adulto , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Idoso , Angiofluoresceinografia/métodos
8.
Biomed Opt Express ; 14(7): 3726-3747, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37497506

RESUMO

Optical coherence tomography (OCT) is the most widely used imaging modality in ophthalmology. There are multiple variations of OCT imaging capable of producing complementary information. Thus, registering these complementary volumes is desirable in order to combine their information. In this work, we propose a novel automated pipeline to register OCT images produced by different devices. This pipeline is based on two steps: a multi-modal 2D en-face registration based on deep learning, and a Z-axis (axial axis) registration based on the retinal layer segmentation. We evaluate our method using data from a Heidelberg Spectralis and an experimental PS-OCT device. The empirical results demonstrated high-quality registrations, with mean errors of approximately 46 µm for the 2D registration and 9.59 µm for the Z-axis registration. These registrations may help in multiple clinical applications such as the validation of layer segmentations among others.

9.
J Cataract Refract Surg ; 49(1): 76-83, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36026712

RESUMO

PURPOSE: To assess phase retardation and corneal sublayer thickness repeatability using ultrahigh-resolution polarization-sensitive optical coherence tomography (PS-OCT). SETTING: Narayana Nethralaya Eye Hospital, Bangalore. DESIGN: Observational. METHODS: In this study, all eyes were imaged using a custom-built ultrahigh-resolution PS-OCT and high-resolution hybrid OCT (MS-39). The repeatability of phase retardation en face maps and corneal sublayer thickness profiles was evaluated. The reflectivity and phase retardation were calculated from the 2 orthogonal polarization channels to generate en face maps of phase retardation and corneal sublayer thicknesses. 3 consecutive measurements of all participants were acquired for each eye. For each measurement, the participant was asked to sit back and was realigned again. The repeatability was assessed using the intraclass correlation coefficient (ICC). RESULTS: The study included 20 healthy eyes of 20 participants. The phase retardation en face maps showed preferential arrangement of collagen fibrils with least retardation in the apex and maximum retardation in the periphery. The phase retardation showed excellent repeatability (ICC >0.95) in all zones. The Bowman layer and stromal layer thicknesses were measured with excellent repeatability (ICC >0.93 and >0.99, respectively). Significant differences ( P < .05) in stromal layer thickness were observed between MS-39 and PS-OCT. The repeatability of epithelial thickness measurements was better with PS-OCT than MS-39. CONCLUSIONS: The combinational assessment of corneal birefringence and sublayer thicknesses shows the advanced potential of ultrahigh-resolution PS-OCT in routine clinical practice over current OCT devices.


Assuntos
Córnea , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Índia , Refração Ocular , Paquimetria Corneana
10.
Biomed Opt Express ; 14(6): 2709-2725, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37342719

RESUMO

Using conventional optical coherence tomography (OCT), it is difficult to image Henle fibers (HF) due to their low backscattering potential. However, fibrous structures exhibit form birefringence, which can be exploited to visualize the presence of HF by polarization-sensitive (PS) OCT. We found a slight asymmetry in the retardation pattern of HF in the fovea region that can be associated with the asymmetric decrease of cone density with eccentricity from the fovea. We introduce a new measure based on a PS-OCT assessment of optic axis orientation to estimate the presence of HF at various eccentricities from the fovea in a large cohort of 150 healthy subjects. By comparing a healthy age-matched sub-group (N = 87) to a cohort of 64 early-stage glaucoma patients, we found no significant difference in HF extension but a slightly decreased retardation at about 2° to 7.5° eccentricity from the fovea in the glaucoma patients. This potentially indicates that glaucoma affects this neuronal tissue at an early state.

11.
Opt Express ; 20(16): 17297-310, 2012 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-23038283

RESUMO

We present an alternative approach for an adaptive optics scanning laser ophthalmoscope (AO-SLO). In contrast to other commonly used AO-SLO instruments, the imaging optics consist of lenses. Images of the fovea region of 5 healthy volunteers are recorded. The system is capable to resolve human foveal cones in 3 out of 5 healthy volunteers. Additionally, we investigated the capability of the system to support larger scanning angles (up to 5°) on the retina. Finally, in order to demonstrate the performance of the instrument images of rod photoreceptors are presented.


Assuntos
Adaptação Ocular , Lasers , Lentes , Oftalmoscópios , Óptica e Fotônica/instrumentação , Óptica e Fotônica/métodos , Adulto , Feminino , Análise de Fourier , Fóvea Central/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Células Fotorreceptoras Retinianas Bastonetes/citologia
12.
Opt Express ; 20(7): 7564-74, 2012 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-22453435

RESUMO

We present a new method to automatically segment the thickness of the choroid in the human eye by polarization sensitive optical coherence tomography (PS-OCT). A swept source PS-OCT instrument operating at a center wavelength of 1040 nm is used. The segmentation method is based entirely on intrinsic, tissue specific polarization contrast mechanisms. In a first step, the anterior boundary of the choroid, the retinal pigment epithelium, is segmented based on depolarization. In a second step, the choroid-sclera interface is found by using the birefringence of the sclera. The method is demonstrated in five healthy eyes. The mean repeatability (standard deviation) of thickness measurement was found to be 18.3 µm.


Assuntos
Corioide/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Oftalmoscopia/métodos , Reconhecimento Automatizado de Padrão/métodos , Tomografia de Coerência Óptica/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Retina ; 32(2): 256-64, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21926940

RESUMO

PURPOSE: Idiopathic juxtafoveal telangiectasia (IJT) is characteristically associated with pigmentary changes. Polarization-sensitive spectral-domain optical coherence tomography (PS-SD-OCT) enables imaging of the retinal pigment epithelium (RPE) and similar melanin-containing structures based on specific polarization properties. This study examined IJT with the latest-generation SD-OCT and PS-SD-OCT, identifying pathophysiologically relevant characteristics of the retinal layers and RPE. METHODS: Twenty-two eyes of 12 patients with IJT were examined by PS-SD-OCT, with special focus on RPE detection and segmentation. Furthermore, SD-OCT technology (Cirrus, Spectralis, and 3D-OCT-1000) was applied. Characteristics of the retinal layers and RPE were evaluated. A classification system based on OCT characteristics of IJT was suggested. RESULTS: Polarization-sensitive spectral-domain optical coherence tomography together with SD-OCT identified characteristic patterns of IJT, used to classify eyes into three distinct groups. Group 1 (5 eyes) revealed discrete alterations in the inner retinal layers; group 2 (12 eyes) showed irregularities of the junction between the inner and outer photoreceptor segments with outer retinal atrophy but an intact RPE. Group 3 (5 eyes) revealed RPE irregularities and loss in addition to intraretinal alterations and photoreceptor abnormalities. CONCLUSION: This study described characteristic morphologic changes in IJT based on PS-SD-OCT and SD-OCT. Morphologic changes were classified, possibly leading to an OCT-based grading scheme. The intensity images of SD-OCT verified intraretinal and photoreceptor irregularities in great detail, whereas PS-SD-OCT additionally showed RPE alterations.


Assuntos
Epitélio Pigmentado da Retina/patologia , Telangiectasia Retiniana/patologia , Tomografia de Coerência Óptica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Telangiectasia Retiniana/classificação , Acuidade Visual/fisiologia
14.
Optom Vis Sci ; 89(5): 585-92, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22525128

RESUMO

PURPOSE: To demonstrate the ability of a new high-speed polarization-sensitive optical coherence tomography (PS-OCT) system for retinal imaging at 1040 nm. METHODS: A new polarization-sensitive swept source OCT system in the 1 µm wavelength range is used to image the retina of healthy volunteers. The instrument is operated at an A-scan rate of 100 kHz which is about three times faster than previously reported PS-OCT instruments in this wavelength region. The increased imaging speed can be used to record densely sampled volumes of the retina. Moreover, it enables averaging of several B-scans recorded at the same location to obtain high-definition B-scans without the use of an eye tracker. RESULTS: Polarization-sensitive images of healthy volunteers clearly show the retinal pigment epithelium as a depolarizing layer. In addition, the good tissue penetration of the system allows the visualization of the sclera, which is highly birefringent and therefore shows increased image contrast with PS-OCT. CONCLUSIONS: PS-OCT in the 1 µm wavelength region shows similar polarization effects as in the 840 nm wavelength range. The high speed enables averaging of several B-scans to obtain high-definition polarization-sensitive images. The new system provides excellent penetration depth into the choroid and sclera.


Assuntos
Processamento de Imagem Assistida por Computador , Epitélio Pigmentado da Retina/anatomia & histologia , Tomografia de Coerência Óptica/instrumentação , Birrefringência , Desenho de Equipamento , Humanos , Valores de Referência , Reprodutibilidade dos Testes
15.
J Cataract Refract Surg ; 48(8): 929-936, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35082233

RESUMO

PURPOSE: To evaluate phase retardation (PR) across healthy eyes and eyes with thin corneas (<500 µm) and with asymmetric and bilateral keratoconus (KC). SETTING: Narayana Nethralaya Eye Hospital, Bangalore, India. DESIGN: Observational cross-sectional. METHODS: There were 4 eye groups: healthy eyes (Group 1; n = 10 eyes), eyes with thin corneas and no clinical disease (Group 2; n = 10 eyes), eyes with asymmetric KC (Group 3; n = 5 eyes), and eyes with clinical KC (Group 4; n = 15 eyes). All eyes were imaged with polarization-sensitive optical coherence tomography (PS-OCT), MS-39, and Corvis-ST. Using PS-OCT, PR was analyzed in annular regions. The anterior (A-E) and Bowman (E-B) wavefront aberrations, epithelial Zernike indices (EZI), total corneal thickness, Corvis biomechanical index (CBI), total biomechanical index (TBI), and Belin-Ambrósio overall deviation index (BAD-D) were analyzed. RESULTS: Only CBI, TBI, BAD-D, A-E and E-B aberrations, EZI, and total corneal thickness distributions of Groups 1 (n =10), 2 (n =10), and 3 (n =5) were similar ( P > .05) but not CCT ( P < .05). PR distributions clearly showed that the eyes in Groups 1, 2, and 3 had a normal corneal birefringence unlike Group 4 (n = 10) eyes ( P < .05). The PR map was similar to the preferred orientations of collagen fibers seen in X-ray diffraction ex vivo studies of corneal stroma. CONCLUSIONS: PR distributions may eliminate the uncertainty associated with the stromal status of thin and asymmetric KC corneas. Group 2 and 3 eyes appeared as healthy because of normal corneal birefringence at the time of imaging, but a longitudinal follow-up of these eyes with PS-OCT may assist in early detection of onset of disease.


Assuntos
Ceratocone , Birrefringência , Córnea , Topografia da Córnea/métodos , Estudos Transversais , Humanos , Índia , Ceratocone/diagnóstico , Curva ROC , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos
16.
Invest Ophthalmol Vis Sci ; 63(12): 8, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36331260

RESUMO

Purpose: To study the circumpapillary retinal nerve fiber layer (RNFL) birefringence (BIR) of early glaucoma and age-matched healthy eyes using polarization-sensitive optical coherence tomography (PS-OCT). Methods: In this prospective cross-sectional study, we compared virtual circular PS-OCT B-scans with a diameter of 3.5 mm centered on the optic disc (OD) acquired with a PS-OCT prototype (860 nm center wavelength). Early glaucoma was defined by the glaucomatous appearance of the OD and a pathologic visual field test with a mean deviation (MD) better than -6 dB. The main outcome parameters were BIR, RNFL-thickness (RNFL-T), and phase retardation (RET). The BIR value at each virtual A-scan position was the quotient of the RET measured at the inner segment/outer segment junction divided by the RNFL-T. Results: The dataset comprised 49 early glaucoma patients (mean ± standard deviation [SD]: 64 ± 10 years) and 49 healthy control subjects (61 ± 9 years). Glaucomatous eyes showed a statistically significant lower BIR globally (mean ± SD: 0.108 ± 0.008°/µm vs. 0.112 ± 0.009°/µm, P = 0.033), superiorly (0.116 ± 0.017°/µm vs. 0.126 ± 0.013°/µm, P = 0.0001), and inferiorly (0.112 ± 0.011°/µm vs. 0.121 ± 0.011°/µm, P < 0.0001), and increased BIR in the temporal quadrant (0.088 ± 0.015°/µm vs. 0.078 ± 0.014°/µm, P = 0.0001) compared to healthy eyes. Conclusions: We report a reduced BIR of the RNFL in early perimetric glaucoma, which can be interpreted as a sign of loss or change of intracellular microtubules and may contribute to a better understanding of early disease development. Prospective longitudinal studies are needed to determine whether BIR is altered in pre-perimetric human glaucoma before RNFL-T decline.


Assuntos
Glaucoma , Fibras Nervosas , Humanos , Fibras Nervosas/patologia , Tomografia de Coerência Óptica/métodos , Células Ganglionares da Retina/patologia , Birrefringência , Campos Visuais , Estudos Transversais , Estudos Prospectivos , Glaucoma/diagnóstico , Glaucoma/patologia , Pressão Intraocular
17.
PLoS One ; 17(12): e0278679, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36512582

RESUMO

We present measurements of depolarization introduced by the retinal pigment epithelium (RPE) over a 45° field of view using polarization sensitive optical coherence tomography. A detailed spatial distribution analysis of depolarization caused by the RPE is presented in a total of 153 subjects including both healthy and diseased eyes. Age and sex related differences in the depolarizing character of the RPE are investigated.


Assuntos
Glaucoma , Epitélio Pigmentado da Retina , Humanos , Epitélio Pigmentado da Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Refração Ocular , Nível de Saúde , Angiofluoresceinografia/métodos
18.
Biomed Opt Express ; 13(1): 65-81, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35154854

RESUMO

A technique to accurately estimate trajectories of retinal nerve fiber bundles (RNFB) in a large field of view (FOV) image covering 45° is described. The method utilizes stitched projections of polarization-sensitive optical coherence tomography (PS-OCT) data, as well as a mathematical model of average RNFB trajectories as prior. The fully automatic process was applied to data recorded in healthy subjects and glaucoma patients and automatically detected individual RNFB trajectories are compared to manual traces.

19.
Sci Rep ; 12(1): 88, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996934

RESUMO

To find baseline predictors for subretinal fibrosis (SF) in neovascular age-related macular degeneration (nAMD). Forty-five eyes of 45 participants with treatment-naïve nAMD were consecutively enrolled and treated according to a standardized treat-and-extend protocol. Spectral-domain optical coherence tomography (OCT), color fundus photography and fluorescein angiography as well as novel imaging modalities polarization-sensitive OCT and OCT angiography (OCTA) were performed to detect SF after 1 year and find baseline predictors for SF development. Baseline OCTA scans were evaluated for quantitative features such as lesion area, vessel area, vessel junctions, vessel length, vessel endpoints and mean lacunarity. Additionally, the type of macular neovascularization, the presence of subretinal fluid, intraretinal fluid (IRF), subretinal hyperreflective material (SHRM), retinal hemorrhage as well as best-corrected visual acuity (BCVA) were evaluated. After 12 months 8 eyes (18%) developed SF. Eyes with SF had worse baseline BCVA (p = .001) and a higher prevalence of IRF (p = .014) and SHRM at baseline (p = .017). There was no significant difference in any of the evaluated quantitative OCTA parameters (p > .05) between eyes with and without SF. There were no quantitative baseline microvascular predictors for SF in our study. Low baseline BCVA, the presence of IRF and SHRM, however, are easily identifiable baseline parameters indicating increased risk.


Assuntos
Angiofluoresceinografia , Degeneração Macular/diagnóstico por imagem , Fotografação , Retina/diagnóstico por imagem , Neovascularização Retiniana/diagnóstico por imagem , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Inibidores da Angiogênese/uso terapêutico , Feminino , Fibrose , Humanos , Estudos Longitudinais , Degeneração Macular/tratamento farmacológico , Degeneração Macular/patologia , Degeneração Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Retina/efeitos dos fármacos , Retina/patologia , Retina/fisiopatologia , Neovascularização Retiniana/tratamento farmacológico , Neovascularização Retiniana/patologia , Neovascularização Retiniana/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual
20.
Sci Rep ; 12(1): 9577, 2022 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-35688890

RESUMO

We present a compact multi-modal and multi-scale retinal imaging instrument with an angiographic functional extension for clinical use. The system integrates scanning laser ophthalmoscopy (SLO), optical coherence tomography (OCT) and OCT angiography (OCTA) imaging modalities and provides multi-scale fields of view. For high resolution, and high lateral resolution in particular, cellular imaging correction of aberrations by adaptive optics (AO) is employed. The entire instrument has a compact design and the scanning head is mounted on motorized translation stages that enable 3D self-alignment with respect to the subject's eye by tracking the pupil position. Retinal tracking, based on the information provided by SLO, is incorporated in the instrument to compensate for retinal motion during OCT imaging. The imaging capabilities of the multi-modal and multi-scale instrument were tested by imaging healthy volunteers and patients.


Assuntos
Pupila , Retina , Humanos , Oftalmoscopia/métodos , Óptica e Fotônica , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA