Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Endovasc Ther ; : 15266028241261661, 2024 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-38881034

RESUMO

PURPOSE: The iliac veins are the least frequent location for venous aneurysms, with only a few cases described globally. The etiology and clinical presentation of this extremely rare entity is diverse and unclear and no treatment consensus has been reached yet. Our purpose is to present an interesting iliac vein aneurysm (IVA) case that we treated in our department, with a brief review of the literature. CASE REPORT: We report a case of a 74-year-old male patient with a giant, 55 mm in diameter, asymptomatic, right common IVA, with concurrent aplasia of the left common iliac vein and an extensive network of venous collaterals. The patient was treated, under general anesthesia, with total endovascular iliocaval reconstruction through implantation of a 32 × 100 mm thoracic aortic tubular Ankura stent graft. The computed tomography venography at first-month follow-up showed the complete exclusion of the IVA, without any endoleak and the patient remains up to date free of symptoms and thromboembolic events. CONCLUSION: Twelve cases of endovascular treatment of IVA have been reported so far, and our case is the first with implantation of a thoracic aortic stent graft. Our results suggest that this technique is safe, effective, and may be considered for appropriately selected patients. CLINICAL IMPACT: This is the first case with total endovascular repair of an iliac vein aneurysm with contralateral iliac vein aplasia through endovenous implantation of a thoracic aortic stent-graft. Our results suggest that this technique is safe and effective and thus, may be considered for appropriately selected cases.

2.
J Clin Monit Comput ; 2024 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-39305452

RESUMO

PURPOSE: Regional anaesthesia techniques provide highly effective alternative to general anaesthesia. Existing evidence on the effect of spinal anaesthesia (SA) on cardiac diastolic function is scarce. This study aimed to evaluate the effects of a single-injection, low-dose SA on left ventricular end-diastolic pressures (LVEDP) using echocardiography in euvolaemic patients undergoing elective vascular surgery. METHODS: This is a prospective study in adult patients undergoing elective vascular surgery with SA. Patients with contraindications for SA or significant valvular disease were excluded. During patients' evaluations fluid administration was targeted using arterial waveform monitoring. All patients underwent echocardiographic studies before and after SA for the assessment of indices reflective of diastolic function. LVEDP was evaluated using the E/e' ratio. Blood samples were drawn to measure troponin and brain natriuretic peptide (BNP) levels before and after SA. RESULTS: A total of 62 patients (88.7% males, 71.00 ± 9.42 years) were included in the analysis. In total population, end-diastolic volume (EDV, 147.51 ± 41.36 vs 141.72 ± 40.13 ml; p = 0.044), end-systolic volume (ESV, 69.50 [51.50] vs 65.00 [29.50] ml; p < 0.001) and E/e' ratio significantly decreased (10.80 [4.21] vs. 9.55 [3.91]; p = 0.019). In patients with elevated compared to those with normal LVEDP, an overall improvement in diastolic function was noted. The A increased (- 6.58 ± 11.12 vs. 6.46 ± 16.10; p < 0.001) and E/A decreased (0.02 ± 0.21 vs. - 0.36 ± 0.90; p = 0.004) only in the elevated LVEDP group. Patients with elevated LVEDP had a greater decrease in E/e' compared to those with normal LVEDP (- 0.03 ± 2.39 vs. - 2.27 ± 2.92; p = 0.002). CONCLUSION: This study in euvolaemic patients undergoing elective vascular surgery provides evidence that SA improved LVEDP.

3.
J Vasc Surg ; 77(3): 941-956.e1, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35948244

RESUMO

OBJECTIVE: To provide an updated systematic literature review summarizing current evidence on aortic neck dilatation (AND) after endovascular aortic aneurysm repair (EVAR) in patients with infrarenal abdominal aortic aneurysm. METHODS: An extensive electronic search in major electronic databases was conducted between January 2000 and December 2021. Eligible for inclusion were observational studies that followed up with patients (n ≥ 20) undergoing EVAR with self-expanding endografts, for 12 or more months, evaluated AND with computed tomography angiography and provided data on relevant outcomes. The primary end point was the incidence of AND after EVAR, and the secondary end points were the occurrence of type Ia endoleak, stent graft migration, secondary rupture, and reintervention. RESULTS: We included 34 studies with a total sample of 12,038 patients (10,413 men; median age, 71 years). AND was defined clearly in 18 studies, but significant differences in AND definition were evidenced. The pooled incidence of AND based on quantitative analysis of 16 studies with a total of 9201 patients (7961 men; median age, 72 years) was calculated at 22.9% (95% confidence interval [CI], 14.4-34.4) over a follow-up period ranging from 12 months to 14 years. The risk of a type Ia endoleak was significantly higher in AND patients compared with those without AND (odds ratio, 2.95; 95% CI, 1.10-7.93; P = .030). Similarly, endograft migration was more common in the AND group compared with the non-AND group (odds ratio, 5.95; 95% CI, 1.80-19.69; P = .004). The combined incidence of secondary rupture and reintervention did not differ significantly between the two groups, even though the combined effect was in favor of the non-AND group. CONCLUSIONS: Proximal AND after EVAR is common and occurs in a large proportion of patients with infrarenal abdominal aortic aneurysm. AND can influence the long-term durability of proximal endograft fixation and is significantly related to adverse outcomes, often leading to reinterventions.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Resultado do Tratamento , Dilatação/efeitos adversos , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos
4.
J Endovasc Ther ; : 15266028231172379, 2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37166154

RESUMO

PURPOSE: A variety of last-generation endografts are currently available for standard endovascular repair (EVAR) of infrarenal abdominal aortic aneurysms (AAAs). The purpose of this study is to report the preliminary clinical outcomes of the Minos trimodular stent-graft system, which was recently introduced to the European market. MATERIALS AND METHODS: Between February 2020 and 2022, we treated 41 consecutive AAA patients (mean age 72.2±8.5, 37 males) with elective standard EVAR using the Minos. The mean maximum diameter of AAAs was 54.7±6.6 mm, the mean proximal neck's (PN) diameter was 24.8±2.7 mm, while the relevant length and angulation were 16.0 mm and 21.7°, respectively. Overall, 22 (53.6%) patients presented with shorter and angulated PN, according to the stent-graft's instructions of use, and in 6 (14.6%) patients the PN angulation >60° was combined with concomitant iliac angulation >60°. Eleven (26.8%) EVARs were performed with concomitant enormous iliac artery narrowing and tortuosity. Finally, in 19 (46.3%) AAAs, the distal iliac landing zone was aneurysmatic and they were treated with the bell-bottom technique in 17 patients and with limb extension to the external iliac artery in two cases. We evaluated technical and clinical success of the index procedures, which was based on the combination of five factors: freedom from EVAR-related mortality, from graft-related endoleak of any type, from migration at any part of graft as well the absence of notable increase AAA's sac maximum diameter and the patency of bifurcated stent-graft and of access vessels. RESULTS: Primary technical and clinical success of index procedures was 100%. During a median 12-month radiological follow-up the clinical success remained 100%. No type I or III endoleak, stent-graft migration, EVAR-related death, AAA rupture, or graft-related adverse events or reinterventions were documented. Four (9.8%) type II endoleaks were detected with stable AAA sac diameter. The overall incidence of sac regression was 34.1% (n=14). CONCLUSION: The preliminary results of our series showed that Minos provided excellent feasibility and safety features even through angulated and tortuous iliac vessels and in short and angulated PNs. The overall clinical success at 1 year suggests that performance of Minos follows very high standards. Further validation of these promising results with long-term data is acquired to complete the evaluation of this recently introduced stent-graft system. CLINICAL IMPACT: The current study explored the clinical performance of a new in market ultra-low profile bifurcated abdominal aortic stent-graft, the MINOS. The early and 12-month results of study suggest that implantation of this stent-graft in standard EVAR, even in hostile proximal aortic neck and iliac vessels conditions, follows very high clinical standards and encourage the further clinical use of MINOS.

5.
J Endovasc Ther ; : 15266028231167998, 2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37078515

RESUMO

PURPOSE: To measure the long-term proximal aortic neck dilatation (AND) after elective endovascular aortic aneurysm repair (EVAR) with a variety of contemporary, third-generation, endograft devices. MATERIALS AND METHODS: This is a noninterventional prospective cohort study of 157 patients that underwent standard EVAR with self-expanding abdominal endografts. Patients' recruitment lasted from 2013 to 2017, and postoperative follow-up was up to 5 years. A computed tomography angiography (CTA) was performed at the first month and then at 1, 2, and 5 years. Proximal aortic neck's (PAN) basic morphological characteristics (diameter, length, angulation) were measured based on the analysis of CTA in a standardized fashion. Neck-related adverse events, such as migration, endoleak or rupture, and reinterventions were recorded. RESULTS: Significant straightening of the PAN was evident even in the first-month CTA with concurrent neck shortening that became significant at 5 years. Both the suprarenal aorta and the PAN significantly dilated overtime, with PAN dilating more progressively. Mean neck dilatation at the juxtarenal level was 0.8±0.4 mm at 1 year, 1.8±0.8 mm at 2 years, and 3.9±1.7 mm at 5 years, with a mean neck dilatation rate of 0.07 mm/month overall. The incidence of AND ≥2.5 mm was 37.2% at 2 years and 58.1% at 5 years after EVAR and was considered important (≥5 mm) in 11.5% of patients at 2 years and 30.6% of patients at 5 years. A multivariate analysis performed showed that the endograft oversizing, the preoperative neck diameter, and the preoperative abdominal aortic aneurysm sac diameter served as independent predictors of AND at 5 years. At the 5-year follow-up, 8 late type Ia endoleaks (6.5%) and 7 caudal migrations (5.6%) were identified, while no late ruptures were reported. In total, 11 late endovascular reinterventions (8.9%) were performed. Overall, proximal neck-related adverse outcomes (5/7 migrations and 5/8 endoleaks) and reinterventions (7/11) were significantly associated with the presence of important late AND. CONCLUSION: Proximal AND after EVAR is common. It can influence the long-term durability of proximal endograft fixation and is significantly associated with adverse outcomes, often leading to reinterventions. A systemic and extended surveillance protocol is needed for maintenance of good long-term results. CLINICAL IMPACT: This is a thorough and systematic analysis of the long-term geometric remodeling of the proximal aortic neck after EVAR, that highlights the importance of a strict, and extended surveillance protocol for maintenance of good long-term results of EVAR.

6.
Eur J Vasc Endovasc Surg ; 66(2): 270-277, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37172689

RESUMO

OBJECTIVE: To evaluate in vitro the performance of in vivo published covered or bare metal chimney stents (ChSs) in combination with the Endurant II abdominal endograft (Medtronic) as the only CE approved main graft (MG) in the treatment of juxtarenal abdominal aortic aneurysms with the chimney endovascular aneurysm repair (chEVAR) technique. METHODS: Bench top experimental study. A silicon flow model with adjustable physiological simulating conditions and patient based anatomy was used to test nine different MG-ChS combinations: Advanta V12 (Getinge); BeGraft+ (Bentley); VBX (Gore & Associates Inc.); LifeStream (Bard Medical); Dynamic (Biotronik); Absolute Pro (Abbott); double Absolute Pro; Viabahn (Gore) lined with Dynamic; and Viabahn lined with EverFlex (Medtronic). Angiotomography was performed after each implantation. DICOM data were analysed blindly twice per observer by three independent experienced observers. Each blinded evaluation was performed at one month intervals. The main analysed parameters were the area of gutters, MG and ChS maximum compression, and the presence of infolding. RESULTS: Bland-Altman analysis confirmed adequate results correlation (p < .05). Each employed ChS showed significantly different performance favouring the balloon expandable covered stent (BECS). The smallest gutter area was seen in the combination with Advanta V12 (0.26 cm2). MG infolding was observed in all tests. The lowest ChS compression was observed in the combination with BeGraft+ (compression 4.91%, D ratio 0.95). In our model, BECSs showed higher angulations than bare metal stents (BMSs) (p < .001). CONCLUSION: This in vitro study shows the variability of performance with each theoretically possible ChS and explains the divergent ChS outcomes in the published literature. BECS in combination with the Endurant abdominal device confirms their superiority vs. BMS. The presence of MG infolding in each test underlines the need for prolonged kissing ballooning. Angulation evaluation and comparison with other in vitro and in vivo publications demands the need for further investigation in transversely or upwardly oriented target vessels.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Silício , Stents , Desenho de Prótese , Resultado do Tratamento
7.
Vascular ; 31(3): 455-462, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35225085

RESUMO

OBJECTIVE: To describe mid-term outcomes of the use of EndoAnchors as an adjunct for arch and thoracic endovascular aortic repair (TEVAR). METHODS: A retrospective multicentre series from nine centres using the Heli-FX EndoAnchor System (Medtronic Inc, Minneapolis, USA) at TEVAR over May 2014-May 2019 is presented. The study is registered at ClinicalTrials.gov with number NCT04100499. The primary outcome was freedom from Type I endoleak at EndoAnchors deployments; secondary outcomes included evaluation of aortic wall penetration (AWP) at first computed tomography scan, EndoAnchor-related issues and mortality. RESULTS: 54 high-risk patients (35 males/19 females, age 73 ± 11 years) with arch, thoracic and thoracoabdominal aneurysmal disease (3 chronic post-dissection and one patch pseudoaneurysm), with a mean neck length 19.7 ± 6.6 mm that were treated with multiple hybrid and endovascular techniques were included. A total of 329 EndoAnchors were used with a mean of 6.1 ± 2.5 per patient. Overall adequate AWP was 86%, whereas arch (Ishimaru's zones 0-2) deployments achieved 80.6% when compared to 87.3% in descending thoracic aorta (dTA); although there was no statistical significance. Freedom from type I endoleaks was 88% at 2 year follow-up, due to 4 type IA endoleaks, two of them successfully treated, one with conservative treatment due to complexity of repair and remaining patient died 1 year later due to endograft infection. There were reported five EndoAnchor-related issues; four losses and one renal stent-graft was crushed due to catheter deflection solved with balloon reinflation. None of the losses had clinical significance. Overall mortality is described for 7 (9.5%) patients, one of them aneurysm-related. CONCLUSIONS: The adjunctive use of EndoAnchors in TEVAR and complex TEVAR procedures achieved acceptable outcomes at midterm in a high-risk series with hostile seal zones. Still, they should be still judiciously used as there is lack of data to suggest a more liberal use; therefore, the landing zone should not be compromised in favour of their use.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia
8.
J Endovasc Ther ; 29(2): 226-239, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34605299

RESUMO

PURPOSE: Chimney endovascular abdominal aortic aneurysm repair (CHEVAR) has predominantly been described as an alternative technique for the management of urgent presentations of degenerative pararenal aortic aneurysms (dPAAs). However, the role of CHEVAR in the treatment of asymptomatic patients remains unknown. The aim of current multinational study was to evaluate the outcomes of elective CHEVAR of dPAAs. MATERIAL AND METHODS: Retrospective analysis of 267 consecutive dPAA patients treated with elective CHEVAR at 13 European and US centers from 2008 to 2014. Primary endpoints were 30 days and out of hospital CHEVAR-related mortality. Secondary endpoints included persistent type Ia endoleak or endotension, angiographically confirmed occlusion and/or high-grade chimney graft (CG) or involved splanchnic vessel stenosis identified at index procedure and/or during follow-up, as well as CHEVAR-related re-intervention. RESULTS: Mean follow-up time was 25.5±13.3 months. The 442 visceral vessels were involved and mean number of CGs per patient was 1.63±0.7. 436 targeted vessels were successfully cannulated. The aortic graft intentionally covered 6 renal arteries and immediate technical success was 98.6%. The 30 days mortality was 1.9% (n=5), while the in-hospital complication rate was 10.1% (n=27) including 3 strokes, 1 permanent dialysis, and 1 intestinal ischemia. No 30 day type Ia endoleaks were detected and 3.2% of CGs (n=14, including the intentionally covered) had evidence of occlusion and/or stenosis. The overall CHEVAR-related mortality was 2.2% (n=6). Freedom from primary and secondary type Ia endoleak/endotension rates at 3 years was 93.0% and 98.0%, respectively. Primary and secondary CG patency was 87.0% and 89.0%. Primary and secondary endovascular freedom from any endpoint at 3 years was 81.0% and 94.0% respectively. CONCLUSION: Elective use of CHEVAR in the management of dPAAs seems to be durable. These results are comparable to published outcomes with other total endovascular strategies, which justifies an expanded role for CHEVAR in the treatment of asymptomatic patients presenting with dPAAs.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Humanos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents , Resultado do Tratamento
9.
J Endovasc Ther ; : 15266028221127839, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36214450

RESUMO

PURPOSE: To analyze sac evolution patterns in matched patients with hostile neck anatomy (HNA) treated with standard endovascular aneurysm repair (sEVAR) and endosutured aneurysm repair (ESAR). METHODS: Observational retrospective study using prospectively collected data between June 2010 and December 2019. ESAR group data were extracted from the primary arm of the PERU registry with an assigned identifier (NCT04100499) at 8 centers and those from the sEVAR came from 4 centers. Suitability for inclusion required: no proximal endograft adjuncts (besides EndoAnchor use), ≤15 mm neck length and minimum of 12-months follow-up imaging. Bubble-shaped neck (noncylindrical short neck with discontinuous seal) aspect was analyzed. Both groups were analyzed using propensity score matching (PSM) for aortic neck length, width, angulation, and device fixation type. Main outcome assessed was sac evolution patterns (sac expansion and regression were defined as >5mm increase or decrease, of the maximum sac diameter respectively; all AAAs within this ±5 mm range in diameter change were considered stable) and secondary outcomes were type-Ia endoleaks; other endoleaks and mortality. A power analysis calculation >80% was confirmed for sac regression evaluation. RESULTS: After exclusions, PSM resulted in 96 ESAR and 96 sEVAR patients. Mean imaging follow-up (months) was 44.4±21.3 versus 43.0±19.6 (p=0.643), respectively. The overall number of patients achieving sac regression was higher in the ESAR group (n=57, 59.4% vs n=31, 32.3%; p<0.001) and the cumulative sac regression achieved at 5 years was 65% versus 38% (p=0.003) in favor of the ESAR group. There were no statistically significant differences in type-Ia endoleak and/or other endoleaks. Univariate analysis for sac regression patients in the sEVAR and ESAR group individually showed the bubble-shape neck as a predictor of sac regression failure. There were no statistical differences in overall and aneurysm-related mortality. CONCLUSION: Endosutured aneurysm repair provided improved rates of sac regression for patients with AAA and HNA when compared with sEVAR at midterm and up to 5 years, despite similar rates of type-Ia endoleaks, and the need to consider some important limitations. The presence of bubble-shaped neck was a predictor of sac regression failure for both groups equally. CLINICAL IMPACT: The use of EndoAnchors aids and improves EVAR treatment in hostile neck anatomies by an increased rate of sac regression when compared to EVAR treatment alone in up to 5 year analysis. Moreover, a trend to reduced number of type Ia endoleaks is also achieved, although not significant in the present study. This data, adds to current and growing evidence on the usefulness of EndoAnchors for AAA endovascular treatment.

10.
Vascular ; 30(1): 27-37, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33568007

RESUMO

OBJECTIVES: We aim to describe real-world outcomes from multicenter data about the efficacy of adjunct Heli-FX EndoAnchor usage in preventing or repairing failures during infrarenal endovascular aneurysm repair (EVAR), so-called EndoSutured-aneurysm-repair (ESAR). METHODS: The current study has been assigned an identifier (NCT04100499) at the US National Library of Medicine (https://ClinicalTrials.gov). It is an observational retrospective study of prospectively collected data from seven vascular surgery departments between June 2010 and December 2019. Patients included in the ANCHOR registry were excluded from this analysis. The decision for the use of EndoAnchors was made by the treating surgeon or multidisciplinary aortic committee according to each center's practice. Follow-up imaging was scheduled according to each center's protocol, which necessarily included either abdominal ultrasound or radiography or computed tomographic scan imaging. The main outcomes analyzed were technical success, freedom from type Ia endoleaks (IaEL), all-cause and aneurysm-related mortality, and sac variation and trends evaluated for those with at least six months imaging follow-up. RESULTS: Two hundred and seventy-five patients underwent ESAR in participating centers during the study period. After exclusions, 221 patients (184 males, 37 females, mean age 75 ± 8.3 years) were finally included for analysis. Median follow-up for the cohort was 27 (interquartile range 12-48) months. A median 6 (interquartile range 3) EndoAnchors were deployed at ESAR, 175 (79%) procedures were primary and 46 (21%) revision cases, 40 associated with type IaEL. Technical success at operation (initial), 30-day, and overall success were 89, 95.5, and 96.8%, respectively; the 30-day success was higher due to those with subsequent spontaneous proximal endoleak seal. At two years, freedom from type IaEL was 94% for the whole series; 96% and 86% for the primary and revision groups, respectively; whereas freedom from all-cause mortality, aneurysm-related mortality, and reintervention was 89%, 98%, and 87%, respectively. Sac evolution pre-ESAR was 66 ± 15.1 vs. post ESAR 61 ± 17.5 (p < 0.001) and for 180 patients with at least six-month follow-up, 92.2% of them being in a stable (51%) or regression (41%) situation. CONCLUSIONS: This real-world registry demonstrates that adjunct EndoAnchor usage at EVAR achieves high rates of freedom from type IaEL at mid-term including in a high number of patients with hostile neck anatomy, with positive trends in sac-size evolution. Further data with longer follow-up may help to establish EndoAnchor usage as a routine adjunct to EVAR, especially in hostile necks.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Médicos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Peru , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
11.
J Vasc Surg ; 73(2): 433-442, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32473338

RESUMO

OBJECTIVE: In the treatment of pararenal abdominal aortic aneurysms and aortic pathologic processes, chimney endovascular aneurysm repair (CHEVAR) represents an alternative technique for urgent cases. The aim of the study was to evaluate the outcomes of CHEVAR in the elective setting. METHODS: We performed a retrospective analysis of prospectively collected records of 165 consecutive asymptomatic CHEVAR patients who were treated between March 2009 and January 2018 with the Endurant stent graft (Medtronic, Santa Rosa, Calif). A total of 244 chimney grafts (CGs) were implanted. The primary end point was clinical success, defined as freedom from procedure-related mortality, persistent type IA endoleak, occlusion or high-grade stenosis (>70%) of CGs, and any chimney technique-related secondary procedure for the entire follow-up period. Secondary clinical success included patients with successful treatment of a primary end point with a secondary endovascular procedure. RESULTS: All 244 targeted chimney vessels were successfully cannulated. Total perioperative morbidity was 7.8% (n = 13), including 3 (1.8%) cases of bowel ischemia, 1 (0.6%) patient with renal ischemia, and 1 patient (0.6%) with stroke. Median follow-up was 25.5 ± 2.2 months. Both 30-day and follow-up procedure-related mortality rates were 1.8% (n = 3). Primary and secondary freedom from persistent type IA endoleak rates were 96.4% (n = 159) and 99.4% (n = 164), respectively. Primary and secondary CG patency rates were 92.2% (n = 225) and 95.9% (n = 234), respectively. The rate of reinterventions related to the chimney technique was 10.9% (n = 18), and 83.3% of them were performed by endovascular means. The estimated cumulative primary patency and freedom from persistent type IA endoleak were 87.5% and 95.3%, respectively, and the primary and secondary clinical successes rates at midterm were 80.3% and 87.5%, respectively. CONCLUSIONS: The elective use of CHEVAR with the Endurant stent graft in our series showed favorable midterm clinical results, which are similar to the published results of other total endovascular modalities. A prospective randomized trial of elective treatment of pararenal abdominal aortic aneurysms and aortic pathologic processes with current endovascular options is needed to assess the value of CHEVAR in the elective setting.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Comorbidade , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
12.
J Endovasc Ther ; 28(4): 585-592, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34060354

RESUMO

OBJECTIVE: To evaluate early and follow-up outcomes following bilateral use of iliac branch devices (IBD) for aortoiliac endografting and assess the impact of center volume. We used data from the pELVIS international multicentric registry. METHODS: For the purpose of this study, only those patients receiving concomitant bilateral IBD implantation were analyzed. To assess the impact that procedural volume of bilateral IBD implantation could have on early and follow-up outcomes, participating institutions were classified as Site(s) A if they had performed >10 and/or >20% concomitant bilateral IBD procedure, otherwise they were classified as Site(s) B. Endpoints of the analysis included early (ie, 30-day) mortality and morbidity, as well as all-cause and aneurysm-related mortality during follow-up. Additional endpoints that were evaluated included IBD-related reinterventions, IBD occlusion or stenosis requiring reintervention (ie, loss of primary patency), and IBD-related type I endoleak. RESULTS: Overall, 96 patients received bilateral IBD implantation (out of 910 procedures collected in the whole pELVIS cohort), of whom 65 were treated at Site A (ie, Group A) and 31 were treated at Site(s) B (ie, Group B). In total, only 1 death occurred within 30 days from bilateral IBD implantation, and 9 patients experienced at least 1 major complication without any significant difference between subjects in Group A versus those in Group B (10.8% vs 6.5%, p=0.714). In the overall cohort, the 2-year freedom from IBD-related type I endoleaks and IBD primary patency were 96% and 92%, respectively; no significant differences were seen in those rates between Group A or Group B (95% vs 100%, p=0.335; 93% vs 88%, p=0.470). Freedom from any IBD-related reinterventions was 83% at 2 years, with similar rates between study groups (85% vs 83%, p=0.904). CONCLUSIONS: Within the pELVIS registry, concomitant bilateral IBD implantation is a safe and feasible technique for management of aortoiliac aneurysms in patients with suitable anatomy. Despite increased technical complexity, effectiveness of the repair is satisfactory with low rates of IBD-related adverse events at mid-term follow-up. Procedural volume does not seem to affect technical or clinical outcomes after bilateral use of IBD, which remains a favorable treatment option in selected patients.

13.
Ann Vasc Surg ; 72: 498-506, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32949740

RESUMO

BACKGROUND: We aimed to investigate whether the transfusion of 2 units of fresh frozen plasma (FFP) immediately post aneurysm exclusion has any effect on the perioperative fibrinogen levels and the outcome of patients undergoing elective endovascular repair (EVAR) of abdominal aortic aneurysm (AAA). METHODS: Consecutive infrarenal AAA patients undergoing elective EVAR with the bifurcated Endurant-II stent-graft (Medtronic) were recruited from 2 vascular units. The first unit has a routine policy of administering 2 units of FFP immediately upon aneurysm exclusion (FFP group), whereas the second unit has no such policy (control group). Serum fibrinogen levels were measured on admission and 24 hr post-EVAR and the perioperative change in fibrinogen (Δfib) was calculated (24-hr postoperative minus preoperative fibrinogen). The 2 groups were compared with regards to the perioperative fibrinogen levels (preoperative, 24-hr postoperative, and Δfib) and the outcome (endoleaks, reinterventions, major adverse cardiovascular events, death) during follow up. RESULTS: A total of 70 patients (41 in the FFP group, 29 controls) were examined. There were 68 men, the mean age was 70 ± 7 years and the maximum AAA diameter was 63.3 ± 13.8 mm. During the follow up (34 ± 19 months), a total of 6 endoleaks were recorded (2 type Ia, 2 type Ib and 1 type II). Mean preoperative fibrinogen, 24-hr postoperative fibrinogen and Δfib was 391.1 ± 92.8 mg/dL, 367.7 ± 97.8 mg/dL and -23.5 ± 51.02 mg/dL, respectively. There was a trend for the fibrinogen to fall 24 hr postprocedure, but this was not statistically significant (P = 0.07). There was a weak negative association between Δfib and endoleaks (P = 0.007, r = -0.29). Compared to controls, the FFP group had a higher 24-hr postoperative fibrinogen (401.8 ± 112.9 mg/dL vs. 319.3 ± 34.9 mg/dL, P < 0.0001) and a lower Δfib (-3.00 ± 56.01 mg/dL vs. -52.48 ± 21.15 mg/dL, P < 0.0001). No significant difference was observed between the 2 groups with regards to endoleaks, reinterventions, major adverse cardiovascular events, or deaths. CONCLUSIONS: Transfusion of 2 units of FFP postaneurysm exclusion prevents a significant drop in plasma fibrinogen 24 hr post-EVAR, but the impact on clinical outcome has yet to be defined.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Fibrinogênio/metabolismo , Troca Plasmática , Plasma , Idoso , Aneurisma da Aorta Abdominal/sangue , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Biomarcadores/sangue , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Grécia , Humanos , Masculino , Pessoa de Meia-Idade , Troca Plasmática/efeitos adversos , Troca Plasmática/mortalidade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Reoperação , Fatores de Tempo , Resultado do Tratamento
14.
Folia Med Cracov ; 61(4): 115-119, 2021 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-35180207

RESUMO

An 11-year old boy presented with a blunt trauma in the right inguinal area after a bicycle accident. Initial clinical picture was indicative of decreased arterial blood supply to the right lower extremity and the diagnostic confirmation was made with a colour flow Doppler ultrasonography. During operative investigation, a thrombosis of the common femoral artery, 3.5 cm in length, was found. The thrombotic part of the femoral artery was removed and replaced with a venous graft taken from the major saphenous vein, before the saphenofemoral junction. Postoperative course was uneventful. Traumatic thrombosis of the common femoral artery as a result of a blunt trauma is very rare, as only 4 relevant cases have been described previously.


Assuntos
Trombose , Ferimentos não Penetrantes , Criança , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/lesões , Artéria Femoral/cirurgia , Veia Femoral/lesões , Veia Femoral/cirurgia , Humanos , Perna (Membro) , Masculino , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico por imagem
15.
Ann Vasc Surg ; 69: 418-425, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32768543

RESUMO

BACKGROUND: The total endovascular approach is in current evolution, and many series have described variable outcomes for branched technology, chimney techniques, or fenestrated repair; and even a combination of some of them. We aim to describe the current outcomes on physician-modified endograft for the treatment of arch diseases. METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were used for this systematic review. The search was applied to MEDLINE, EMBASE, Google Scholar, and Cochrane Central Register of Controlled Trials. We used the following search terms in all possible combinations: home-made, physician-modified, surgeon-modified, on-table modification, hand-made, endograft, endovascular, aortic arch, and TEVAR: a thorough search of the English-language literature published until March 2020 was performed to identify studies using physician-modified endograft for the treatment of arch diseases. Only studies with treatment of 3 patients or more and with a minimum of 6-month follow-up were enrolled in the systematic review, whereas case reports were excluded from the analysis. RESULTS: Six articles participated in the systematic review after the exclusions, including a total of 239 patients for analysis. Four high-volume centers provided data including a high rate of single fenestrations in zone 2, accounting for nearly 70% of the cases. About 80.3% were males, and 67.4% received urgent treatment mainly for acute/subacute dissection (64.4%). Thoracic aortic aneurysm and/or postdissection arch aneurysm was the second leading cause of treatment with 25.9%. There was a technical success of 93.7% reaching up to 98.3% when additional procedures were performed. The 30-day mortality, stroke/transient ischemic attack, paraplegia, and stent-induced new entry rates were 2.9%, 2.1%, 0.4%, and 0.4%, respectively; whereas, overall mortality of the study was 4.6% at a mean follow-up of 33.2 ± 14.8 months. CONCLUSIONS: Endograft modification for aortic arch diseases' treatment demonstrates to be safe and highly effective, especially for aortic dissections needing single zone 2 fenestrations. Although outcomes achieved in the study seem encouraging, these are achieved at high-volume experienced centers, thus, they need to be judiciously evaluated, whereas proctoring may be a good alternative if one patient may benefit from the technique in an unexperienced center.


Assuntos
Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Doenças da Aorta/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
16.
Ann Vasc Surg ; 64: 124-131, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31634594

RESUMO

BACKGROUND: Efforts to achieve optimal seal during endovascular aortic aneurysm repair (EVAR) may produce partial coverage of the lowest renal artery and in some cases even occlusion. This coverage might alter the renal ostial flow, which could finally affect renal function. We sought to evaluate the incidence of renal ostium coverage and its possible effects on renal function. METHODS: All patients undergoing elective EVAR with suprarenal fixation devices between January 2014, and December 2017, at our institution were identified. Patients with preoperative and postoperative computed tomography angiography (CTA), as well as the preoperative, postoperative, and one year postintervention creatinine levels and estimated glomerular filtration rate (eGFR) were included in the present study. Patients in hemodialysis, with a preoperative eGFR <30 mL/min, urgent EVAR, neck adjunctive procedures, excessive aortic thrombus, or procedure-related reintervention were excluded. RESULTS: A total of 127 patients received EVAR for aortoiliac aneurysmatic pathologies between January 2014, and December 2017. Forty-three of them met the inclusion criteria having a median follow-up of 18.8 months (range; 12.0-53.9). Twenty-six (60.5%) patients presented at least one criterion of hostile neck condition and 23 (53.5%) had a preoperative eGFR <60 mL/min. The average distance from the proximal endograft fabric to the lower renal artery was 1.5 mm (range, 0.0-6.0) while a total of 15 renal ostia (34.9%) suffered unintended partial coverage (range, 20 to 75% of the renal ostium) in the postoperative CTA. Nine of these patients (60%) had a hostile neck condition. Eight patients (18.6%) suffered significant deterioration (>20% of the eGFR), 27 patients (62.8%) maintained their renal function and 8 (18.6%) presented an improvement of the eGFR in the latest available blood sample. Renal function impairment showed no significant association with renal ostium coverage (P = 0.561), hostile neck condition (P = 0.973), or the diameter of the renal artery (P = 0.835). In the subgroup analysis, patients with the eGFR <60 mL/min did not show significantly greater renal function deterioration (P = 0.568). CONCLUSIONS: Partial renal coverage is not an uncommon phenomenon occurring in one-third of the treated patients. However, it was not associated with renal function impairment in the early term. Further studies with longer follow-up are needed to confirm our results in the long haul.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Taxa de Filtração Glomerular , Nefropatias/fisiopatologia , Rim/fisiopatologia , Artéria Renal/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Nefropatias/diagnóstico , Nefropatias/etiologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
J Vasc Surg ; 69(4): 1072-1079.e1, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30545704

RESUMO

OBJECTIVE: Hypogastric aneurysms (HAs) frequently coexist with aortoiliac aneurysms (AIAs). However, the presence of an HA is a contraindication to endovascular aneurysm treatment by iliac branch devices (IBDs) because of the risk of distal sealing-related endoleaks. No robust evidence exists in the published literature, and therefore we sought to evaluate the performance of IBDs in the presence of HAs within a multicenter registry of nine vascular centers. METHODS: Clinical and radiographic information of 804 patients with AIAs treated by IBDs was retrospectively reviewed and analyzed using prearranged, defined, and documented protocols. The treatment period was between January 2005 and April 2017. RESULTS: HA was present in 315 (32.6%) of the overall 910 deployed IBDs. Mean radiologic follow-up was 32 months. The incidence of incomplete aneurysm exclusion and type I endoleak was 3% in the HA group vs 0.7% in the non-HA group (P = .019). The 5-year freedom from IBD-related type I endoleak was 93% vs 98% in the HA group vs the non-HA group, respectively (P = .006). Subgroup analysis of the HA group revealed that use of a single distal bridging stent graft vs multiple bridging devices led to higher rate of type I endoleak (9.6% vs 2.8%; P = .031), branch occlusions (8.3% vs 0.9%; P = .009), and buttock claudication (7.6% vs 1.9%; P = .038). CONCLUSIONS: This series of AIAs with HAs is the largest reported. It shows that HAs coexisting with AIAs, when treated with IBDs, have significantly worse outcomes. Lengthening the distal landing zone with more than one bridging stent graft into the distal healthy hypogastric artery or one of its main branches improves outcomes.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular , Prótese Vascular , Endoleak/etiologia , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Pelve/irrigação sanguínea , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Europa (Continente) , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Masculino , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Ann Vasc Surg ; 60: 61-69, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31028850

RESUMO

BACKGROUND: The durability of endovascular aortic aneurysms repair (EVAR) is highly related to several anatomical constraints. The term "hostile neck" describes several anatomical features that usually make EVAR treatment technically demanding despite having higher risk of failure. The aim of the study was to describe a multicenter experience with EVAR and an adjunctive use of EndoAnchors in hostile neck anatomies. METHODS: Data were prospectively collected from 4 academic vascular centers including 46 patients with a hostile neck treated by standard EVAR with the adjunctive use of EndoAnchors. Twenty-two of them (47.8%, group A) had an intraoperative type Ia endoleak, and 24 (52.2%) patients were treated in a preventive manner (group B). Primary endpoints were technical and procedural success. Secondary endpoints were regression of the aneurysm sac, freedom from type Ia endoleak, and reinterventions. RESULTS: Neck length and diameter showed no statistical difference in preoperative measures, 9.1 ± 6.9 mm and 8.6 ± 2.8 mm and 25.4 ± 4.7 mm and 27.3 ± 4.7 mm, in group A and B, respectively. Aneurysm sac diameter decreased from 58.2 ± 8 mm and 57.9 ± 9.8 mm to 55.7 ± 8.5 mm and 53.8 ± 10.4 mm in group A and B; respectively, at the last computed tomography scan. Technical and procedural success was 97.8% and 100%, respectively, for group B. Group A showed persistence of type Ia endoleak at completion angiogram in 9 (40.9%) patients. Five of them showed early spontaneous sealing at the first (30 days) computed tomography angiography (CTA), and in the remaining 4, a delayed spontaneous sealing was diagnosed at 12-month CTA. No neck-related secondary procedures were performed. Overall survival was 91%. CONCLUSIONS: Our study shows that additional use of EndoAnchors can successfully improve the sealing of abdominal endografts in case of intraoperative type Ia endoleaks in hostile neck anatomies, representing a safe and effective endovascular alternative in our armamentarium. However, meticulous radiological follow-up is necessary because complete resolution of all observed intraoperative type Ia endoleaks was not observed until the 12-month CTA follow-up.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/etiologia , Procedimentos Endovasculares/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/fisiopatologia , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Feminino , Humanos , Masculino , Duração da Cirurgia , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
J Vasc Surg ; 66(6): 1686-1695, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28583728

RESUMO

OBJECTIVE: Hostile proximal aortic neck (HN) challenges the suitability for standard endovascular aneurysm repair (EVAR) of patients at high risk for "open" repair. However, there has been little if any focus placed on the individual role of the "nonlength" HN features in EVAR outcomes. The aim of this study was to evaluate their individual and potentially predictive role in outcomes of EVAR under HN conditions. METHODS: Data of 156 consecutive EVAR patients with short (<15 mm) HN, treated with the Endurant device (Medtronic Cardiovascular, Santa Rosa, Calif) at three European academic vascular centers between 2007 and 2015, were collected and retrospectively analyzed. All patients had at least one of the four well-known nonlength HN criteria (width >32 mm or bulge, angulation >60 degrees, reverse taper anatomy, and circumferential thrombus or calcification >50%) and underwent standard EVAR without additional techniques, such as use of chimney grafts or endoanchors. Primary end points were absence of type IA endoleak at 1 month and midterm follow-up and aneurysm sac stabilization or shrinkage. Secondary end points were 30-day mortality, overall survival, and secondary interventions related to EVAR. The study cohort was classified in two subgroups related to neck length (length <10 mm and length between 10 and 14 mm) as well as in two subgroups according to on-label or off-label stent graft use. RESULTS: Mean clinical and radiologic follow-up was 41.1 ± 24.7 and 31.7 ± 19.0 months, respectively. Overall EVAR-related mortality was 1.9% (n = 3). The total type IA endoleak rate was 5.8% (n = 9). In four patients, the type IA endoleak was detected intraoperatively and solved by endovascular means. A type IA endoleak was detected in three patients at 1 month and in two patients at 2-year follow-up. During follow-up, five patients showed an increase of aneurysm diameter due to type II endoleak and were treated by secondary endovascular reinterventions. The total number of all EVAR-related secondary procedures in the midterm was 12 (7.7%). Univariate analysis showed that the center of treatment and the clinical or anatomic features were not associated with adverse outcomes. Multiple regression and Cox regression analysis of HN features revealed that reverse taper anatomy (conical neck) was the single and significantly associated predictor of proximal EVAR failure (P < .012). Width >32 mm, angulation >60 degrees, and calcification or thrombus were not associated with adverse outcomes. Analysis between HN length cohorts and between on-label and off-label subgroups revealed no difference in outcomes. CONCLUSIONS: A conical neck in hostile anatomies represents the single strongest factor associated with proximal failure of standard EVAR. This finding should be considered and highlighted apart from the length of the infrarenal neck to prevent midterm failure of standard EVAR.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/mortalidade , Endoleak/terapia , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Falha de Tratamento
20.
Cytokine ; 91: 140-144, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28073026

RESUMO

Visfatin is an adipokine molecule acting as an essential coenzyme in multiple cellular redox reactions. The increased serum levels of Visfatin have been correlated with metabolic syndrome and endothelial homeostasis. In this study we investigate the possible relationship of Visfatin serum levels with the severity and location of atherosclerotic peripheral arterial occlusive disease (PAOD). Study protocol included 45 consecutive PAOD and 20 Control patients with age >55years old. Definition of PAOD was based in Rutherord's classification (RC). End-stage PAOD patients (RC-V & -VI) were excluded from study. Data were collected prospectively and included age, gender, atherosclerotic risk factors and the body mass index (BMI). In PAOD patients recorded the PAOD's clinical stage and the presence of carotid stenosis >50%. PAOD patients divided in two subgroups, those with mild (RC-I & -II) and moderate disease (RC-III & -IV). In all serum samples Visfatin was measured, blindly, twice by anosoenzymatic technique. Statistical analysis was performed by non-parametric Mann-Whitney U test, Pearson's chi-square, One Way Anova and Kruskall-Wallis tests, as appropriate. The mean Visfatin value in PAOD and Control groups were 38.5±16.0 and 13.9±3.8ng/ml respectively (p<0.0005). In-PAOD subgroup of patients the visfatin values were not affected by demographics, BMI and atherosclerotic risk factors (p>0.05). Univariate analysis showed that severity of PAOD (mild vs severe), presence of carotid stenosis >50% and multilevel disease significantly affected outcomes (p=0.018, p=0.010 and p=0.006 respectively). In multivariate regression analysis severity of PAOD was the solely factor with strong correlation with high visfatin values (p=0.001). High Visfatin levels seem to be strongly correlated with the presence and severity of PAOD. Further and in depth investigation is needed to define the possible role of Visfatin in atherosclerosis and it's value as a potential prognostic biomarker of PAOD.


Assuntos
Índice de Massa Corporal , Citocinas/sangue , Nicotinamida Fosforribosiltransferase/sangue , Doença Arterial Periférica/sangue , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/patologia , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA