Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Healthc Policy ; 18(3): 31-46, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36917452

RESUMO

Introduction: Identifying ways to eliminate unnecessary transfer of nursing home (NH) residents to hospitals provides an opportunity to improve outcomes and use scarce healthcare resources more efficiently. This study's goal was to better understand where NH residents access X-ray (XR) and computed tomography (CT) scans and to determine if there was a case for mobile radiography policies in New Brunswick. Methods: A retrospective analysis of all the visits to the emergency department (ED) and outpatient imaging departments in two hospitals in Saint John, New Brunswick, in 2020, that involved XR or CT investigations was conducted. Results: There were 521 visits by 311 unique NH residents and 920 investigations (688 XR and 232 CT scans). Most investigations were ordered in the ED (696 of 920; 75.6%; confidence interval: 72.8-78.3%). Of the NH residents who visited the ED and received either an XR or a CT scan, 33.2% received only XR imaging and were discharged back to the NH after a mean ED stay of 5.15 hours. Discussion: The pattern of NH residents' use of the ED for their imaging needs supports the creation of mobile XR policies to deliver more safe and efficient care in a Canadian medium population urban centre.


Assuntos
Serviço Hospitalar de Emergência , Casas de Saúde , Humanos , Novo Brunswick , Estudos Retrospectivos , Canadá , Radiografia
2.
Cureus ; 14(11): e30987, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36475129

RESUMO

OBJECTIVES:  Significant heterogeneity exists internationally in the airway devices used in the pre-hospital setting during cardiac arrest. This study evaluated the first-pass success (FPS) rate of two supraglottic airways (SGAs) used by paramedics during out-of-hospital cardiac arrest: the King LTS-D and the i-gel. METHODS:  By examining 2,680 patient care records compiled by Ambulance New Brunswick between 2015 and 2020, we evaluated the FPS rate of the two SGAs using a 2x2 Pearson chi-square test for association, and a Mann-Whitney U test, to determine whether there were significant differences in FPS rates. RESULTS:  Our study demonstrated a statistically significant association between airway devices and FPS favoring the i-gel with an FPS of 90.6% compared to a 76.6% FPS with the King LTS-D; X 2(1) = 96.01, p < 0.001. The odds of successfully inserting the airway on the first attempt were 2.94 times higher if paramedics used the i-gel than if they used the King LTS-D with a 95% CI [2.32, 3.60]. Mann-Whitney's U test for SGA differences favored the i-gel in fewer attempts for successful insertion (z = -4.357, p < 0.001, d = 0.15). CONCLUSIONS:  Among patients in New Brunswick with out-of-hospital cardiac arrest, paramedics had a higher FPS rate with the i-gel compared to the King LTS-D. Our study also found a statistically significant difference between the King LTS-D and i-gel, favoring the i-gel in fewer attempts. Our findings suggest that the i-gel provides a more consistent FPS rate compared to the King LTS-D within our study populations; however, further research is necessary to determine the clinical implications of this. While multiple attempts at tracheal intubation are associated with negative clinical outcomes, no such evidence exists for SGAs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA