Anal Bioanal Chem ; 411(1): 217-229, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30402675

RESUMO

Biomedical devices are complex products requiring numerous assembly steps along the industrial process chain, which can carry the potential of surface contamination. Cleanliness has to be analytically assessed with respect to ensuring safety and efficacy. Although several analytical techniques are routinely employed for such evaluation, a reliable analysis chain that guarantees metrological traceability and quantification capability is desirable. This calls for analytical tools that are cascaded in a sensible way to immediately identify and localize possible contamination, both qualitatively and quantitatively. In this systematic inter-comparative approach, we produced and characterized sodium dodecyl sulfate (SDS) films mimicking contamination on inorganic and organic substrates, with potential use as reference materials for ambient techniques, i.e., ambient mass spectrometry (AMS), infrared and Raman spectroscopy, to reliably determine amounts of contamination. Non-invasive and complementary vibrational spectroscopy techniques offer a priori chemical identification with integrated chemical imaging tools to follow the contaminant distribution, even on devices with complex geometry. AMS also provides fingerprint outputs for a fast qualitative identification of surface contaminations to be used at the end of the traceability chain due to its ablative effect on the sample. To absolutely determine the mass of SDS, the vacuum-based reference-free technique X-ray fluorescence was employed for calibration. Convex hip liners were deliberately contaminated with SDS to emulate real biomedical devices with an industrially relevant substance. Implementation of the aforementioned analytical techniques is discussed with respect to combining multimodal technical setups to decrease uncertainties that may arise if a single technique approach is adopted. Graphical abstract ᅟ.


Assuntos
Dodecilsulfato de Sódio/análise , Análise Espectral/métodos , Vácuo , Humanos , Padrões de Referência , Dodecilsulfato de Sódio/normas , Propriedades de Superfície
2.
Sensors (Basel) ; 16(7)2016 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-27347950

RESUMO

Transition-edge sensors (TESs) are single photon detectors attractive for applications in quantum optics and quantum information experiments owing to their photon number resolving capability. Nowadays, high-energy resolution TESs for telecommunication are based on either W or Au/Ti films, demonstrating slow recovery time constants. We report our progress on the development of an Al/Ti TES. Since bulk aluminum has a critical temperature (Tc) of ca. 1.2 K and a sufficiently low specific heat (less than 10(-4) J/cm³K²), it can be employed to produce the sensitive material for optical TESs. Furthermore, exploiting its high Tc, Al-based TESs can be trimmed in a wider temperature range with respect to Ti or W. A first Al/Ti TES with a Tc ≈ 142 mK, investigated from a thermal and optical point of view, has shown a response time constant of about 2 µs and single photon discrimination with 0.34 eV energy resolution at telecom wavelength, demonstrating that Al/Ti films are suitable to produce TESs for visible and NIR photon counting.

3.
Mol Nutr Food Res ; 68(10): e2300796, 2024 May.
Artigo em Alemão | MEDLINE | ID: mdl-38704747

RESUMO

Alpha-gal syndrome (AGS) is a mammalian meat allergy associated with tick bites and specific IgE to the oligosaccharide galactose-α-1,3-galactose (α-gal). Recent studies have shown that 10-20% of AGS patients also react to the dairy proteins. Considering the already described role of the meat lipid fraction in AGS manifestations, the aim of this work has been to investigate whether the milk fat globule proteins (MFGPs) could be involved in AGS. The MFGPs are extracted and their recognition by the IgE of AGS patients is proved through immunoblotting experiments. The identification of the immunoreactive proteins by LC-HRMS analysis allows to demonstrate for the first time that butyrophillin, lactadherin, and xanthine oxidase (XO) are α-gal glycosylated. The role of xanthine oxidase seems to be prevalent since it is highly recognized by both the anti-α-gal antibody and AGS patient sera. The results obtained in this study provide novel insights in the characterization of α-Gal carrying glycoproteins in bovine milk, supporting the possibility that milk, especially in its whole form, may give reactions in AGS patients. Although additional factors are probably associated with the clinical manifestations, the avoidance of milk and milk products should be considered in individuals with AGS showing symptoms related to milk consumption.


Assuntos
Glicolipídeos , Glicoproteínas , Gotículas Lipídicas , Leite , Humanos , Animais , Bovinos , Leite/química , Alérgenos/imunologia , Butirofilinas/metabolismo , Feminino , Proteínas do Leite/imunologia , Imunoglobulina E/imunologia , Hipersensibilidade Alimentar/imunologia , Picadas de Carrapatos , Adulto , Masculino , Antígenos de Superfície/imunologia , Pessoa de Meia-Idade , alfa-Galactosidase , Dissacarídeos
4.
Front Microbiol ; 14: 1292461, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38075896

RESUMO

An innovative spectroscopic method that allows to chemically and structurally characterize viruses directly in suspension within few minutes was developed. A library of five different plant viruses was obtained combining dielectrophoresis (DEP), performed with a device specifically designed to capture and agglomerate virus particles, and Raman spectroscopy to provide a chemical fingerprint of virions. The tested viruses, purified from infected plants, were chosen for their economic impact on horticultural crops and for their different morphological and structural features. Using the Raman-DEP device, specific profiles for each virus were successfully obtained, relying on chemical differences occurring even with genetically similar viruses belonging to the same taxonomic species and morphologically indiscernible by transmission electron microscopy (TEM). Moreover, we investigated the potentiality of Raman-DEP to follow dynamic changes occurring upon heat treatment of tobacco mosaic virus (TMV) particles. Raman peak deviations linked to TMV coat protein conformation were observed upon treatment at temperatures equal or higher than 85°C, substantiating the rod-to-spherical shape transitions observed by TEM and the concomitant drastic loss of infectivity following plant inoculation. Overall, the Raman-DEP method can be useful for the characterization of virus (nano)particles, setting the basis to create a database suitable for the study of viruses or virus derived-nanoparticles relevant for the agricultural, medical, or biotechnological fields.

5.
Colloids Surf B Biointerfaces ; 204: 111800, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33945966

RESUMO

In this work the quantification of antimicrobial properties of differently sized AgNPs immobilized on a surface was studied. Three different sizes of spheroidal AgNPs with a diameter of (6, 30 and 52) nm were synthetized and characterized with UV-vis, SEM, TEM and ICP-MS. The MIC (Minimal Inhibitory Concentration) and MBC (Minimal Bactericidal Concentration) against Escherichia coli were investigated. Then, the antibacterial efficacy (R) of amino-silanized glasses coated with different amounts of the three sizes of AgNPs were quantified by international standard ISO 22196 adapted protocol against E. coli, clarifying the relationship between size and antibacterial properties of immobilized AgNPs on a surface. The total amount of silver present on glasses with an R ∼ 6 for each AgNPs size was quantified with ICP-MS and this was considered the Surface MBC (SMBC), which were found to be (0.023, 0.026 and 0.034) µg/cm2 for (6, 30 and 52) nm AgNPs, respectively. Thus, this study demonstrates that active surfaces with a bactericidal effect at least ≥ 99.9999 % could be obtained using an amount of silver almost 100 times lower than the MBC found for colloidal AgNPs. The immobilization reduces the aggregation phenomena normally occuring in liquid media, maximizing the exposed specific superficial area of the AgNPs and their direct contact with bacterial cells. Starting from this glass model system, our work could broaden the way to the development of a wide range of antibacterial materials with very low amount of silver that can be safely applied in biomedical and food packaging fields.


Assuntos
Nanopartículas Metálicas , Prata , Antibacterianos/farmacologia , Escherichia coli , Testes de Sensibilidade Microbiana , Prata/farmacologia
6.
RSC Adv ; 8(49): 27863-27869, 2018 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-35542714

RESUMO

Tip-Enhanced Raman Spectroscopy (TERS) is a topographic and chemical analysis technique with nanoscale resolution, consisting of the combination of Scanning Probe Microscopy (SPM) and Localized Surface Plasmon Resonance (LSPR) for the enhancement of Raman scattering in the vicinity of the probe. The quantification of spatial resolution represents an important issue, and, as of now, standards for calibration are not available. In the present work a candidate reference sample for TERS measurements was fabricated. It consists of a flat, conductive gold surface with a nanometric grating of a self-assembled monolayer of Raman-active organic molecules fabricated by an optimized Electron Beam Lithography (EBL) method to replicate established SPM calibration standards. Its feasibility as a TERS standard was tested by STM-TERS imaging.

7.
Sci Rep ; 8(1): 11305, 2018 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-30054503

RESUMO

Controlling the location and the distribution of hot spots is a crucial aspect in the fabrication of surface-enhanced Raman spectroscopy (SERS) substrates for bio-analytical applications. The choice of a suitable method to tailor the dimensions and the position of plasmonic nanostructures becomes fundamental to provide SERS substrates with significant signal enhancement, homogeneity and reproducibility. In the present work, we studied the influence of the long-range ordering of different flexible gold-coated Si nanowires arrays on the SERS activity. The substrates are made by nanosphere lithography and metal-assisted chemical etching. The degree of order is quantitatively evaluated through the correlation length (ξ) as a function of the nanosphere spin-coating speed. Our findings showed a linear increase of the SERS signal for increasing values of ξ, coherently with a more ordered and dense distribution of hot spots on the surface. The substrate with the largest ξ of 1100 nm showed an enhancement factor of 2.6 · 103 and remarkable homogeneity over square-millimetres area. The variability of the signal across the substrate was also investigated by means of a 2D chemical imaging approach and a standard methodology for its practical calculation is proposed for a coherent comparison among the data reported in literature.

8.
J Pharm Biomed Anal ; 150: 308-317, 2018 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-29272815

RESUMO

There is a strong need in the medical device industry to decrease failure rates of biomedical devices by reducing the incidence of defect structures and contaminants during the production process. The detection and identification of defect structures and contaminants is crucial for many industrial applications. The present study exploits reference-free X-ray fluorescence (XRF) analysis as an analytical tool for the traceable characterization of surface contaminants of medical devices, in particular N,N'-ethylene-bis (stearamide), an ubiquitous compound used in many industrial applications as a release agent or friction reduction additive. Reference-free XRF analysis as primary method has been proven to be capable of underpinning all other applied methods since it yields the absolute mass deposition of the selected N,N'-ethylene-bis (stearamide) contaminant whilst X-ray absorption fine structure analysis determines the chemical species. Ambient vibrational spectroscopy and mass spectroscopy methodologies such as Fourier transform infrared, Raman, and secondary ion mass spectroscopy have been used in this systematic procedure providing an extensive range of complementary analyses. The calibration procedure described in this paper was developed using specially designed and fabricated model systems varying in thickness and substrate material. Furthermore, typical real medical devices such as both a polyethylene hip liner and a silver-coated wound dressing have been contaminated and investigated by these diverse methods, enabling testing of this developed procedure. These well-characterized samples may be used as calibration standards for bench top instrumentation from the perspective of providing traceable analysis of biomaterials and surface treatments. These findings demonstrate the potential importance and usefulness of combining complementary methods for a better understanding of the relevant organic materials.


Assuntos
Contaminação de Equipamentos , Equipamentos e Provisões , Espectrometria por Raios X/normas , Ácidos Esteáricos/análise , Calibragem , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massa de Íon Secundário , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman
SELEÇÃO DE REFERÊNCIAS