Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Sensors (Basel) ; 20(5)2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-32155785

RESUMO

Terahertz pulsed imaging (TPI) was introduced approximately fifteen years ago and has attracted a lot of interest in the pharmaceutical industry as a fast, non-destructive modality for quantifying film coatings on pharmaceutical dosage forms. In this topical review, we look back at the use of TPI for analysing pharmaceutical film coatings, highlighting the main contributions made and outlining the key challenges ahead.


Assuntos
Preparações Farmacêuticas/química , Imagem Terahertz , Calibragem , Formas de Dosagem , Refratometria
2.
Anal Bioanal Chem ; 403(5): 1405-14, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22447218

RESUMO

Terahertz (THz) time-domain spectroscopy and 3D THz pulsed imaging have been explored with regard to polymer materials, both commodity and historic polymers. A systematic spectroscopic study of a wide range of different polymer materials showed significant differences in their spectra. Polyolefins and polystyrenes generally exhibit lower absorption than other examined polymers, various cellulose derivates, poly(vinyl chloride), poly(methyl methacrylate), polyamide, hard rubber and phenol formaldehyde resin, the last of these exhibiting the most intense absorption over the entire range, 0.15-4.2 THz. It was also examined how the presence of plasticisers in poly(vinyl chloride), the presence of fillers in polypropylene, and the degree of branching in polyethylene and polystyrene affect the spectra; inorganic fillers in polypropylene affected the absorption most. With 3D THz pulsed imaging, features in polymer objects were explored, appearing either as integral parts of the material (coatings and pores in foams) or as a consequence of physical deterioration (cracks, delamination). All of these features of various complexities can be successfully imaged in 3D. Terahertz technology is thus shown to have significant potential for both chemical and structural characterisation of polymers, which will be of interest to heritage science, but also to the polymer industry and development of analytical technologies in general.

3.
J Pharm Sci ; 110(5): 2083-2092, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33307044

RESUMO

There is a clear need for a robust process analytical technology tool that can be used for on-line/in-line prediction of dissolution and disintegration characteristics of pharmaceutical tablets during manufacture. Tablet porosity is a reliable and fundamental critical quality attribute which controls key mass transport mechanisms that govern disintegration and dissolution behavior. A measurement protocol was developed to measure the total porosity of a large number of tablets in transmission without the need for any sample preparation. By using this fast and non-destructive terahertz spectroscopy method it is possible to predict the disintegration and dissolution of drug from a tablet in less than a second per sample without the need of a chemometric model. The validity of the terahertz porosity method was established across a range of immediate release (IR) formulations of ibuprofen and indomethacin tablets of varying geometries as well as with and without debossing. Excellent correlation was observed between the measured terahertz porosity, dissolution characteristics (time to release 50% drug content) and disintegration time for all samples. These promising results and considering the robustness of the terahertz method pave the way for a fully automated at-line/on-line porosity sensor for real time release testing of IR tablets dissolution.


Assuntos
Espectroscopia Terahertz , Composição de Medicamentos , Porosidade , Solubilidade , Comprimidos
4.
J Pharm Sci ; 97(4): 1543-50, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17722005

RESUMO

Delayed release dosage forms such as Asacol employ coatings that are engineered to breakdown and release the drug topically at the nominal pH of the lower intestinal tract. Asacol tablets were found to dissolve in an erratic fashion when they are dissolved in buffers below pH 7 which can occur naturally. In this study Terahertz pulsed imaging (TPI) was used to accurately map the coating thickness of a group of Asacol tablets that were subsequently dissolved using the USP method at pH 6.8. The mean dissolution times were found to correlate with the average coating thickness measured over all surfaces. Thickness values for a single randomly selected face did not correlate well with the dissolution results. The speed and ease of TPI mapping may make it an attractive replacement for wet dissolution testing both in product development and eventually for process analysis.


Assuntos
Comprimidos , Tecnologia Farmacêutica , Preparações de Ação Retardada , Concentração de Íons de Hidrogênio , Mesalamina/administração & dosagem , Mesalamina/química , Solubilidade
5.
Biomed Opt Express ; 8(6): 2932-2945, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28663917

RESUMO

Since nearly 20% of breast-conserving surgeries (BCS) require re-operation, there is a clear need for developing new techniques to more accurately assess tumor resection margins intraoperatively. This study evaluates the diagnostic accuracy of a handheld terahertz pulsed imaging (TPI) system to discriminate benign from malignant breast tissue ex vivo. Forty six freshly excised breast cancer samples were scanned with a TPI handheld probe system, and histology was obtained for comparison. The image pixels on TPI were classified using (1) parameters in combination with support vector machine (SVM) and (2) Gaussian wavelet deconvolution in combination with Bayesian classification. The results were an accuracy, sensitivity, specificity of 75%, 86%, 66% for method 1, and 69%, 87%, 54% for method 2 respectively. This demonstrates the probe can discriminate invasive breast cancer from benign breast tissue with an encouraging degree of accuracy, warranting further study.

6.
J Pharm Innov ; 7(2): 87-93, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22707994

RESUMO

Terahertz pulsed spectroscopy was used to qualitatively detect ciprofloxacin hydrochloride monohydrate (CPFX·HCl·H(2)O) in tablets, and terahertz pulsed imaging (TPI) was used to scrutinize not only the coating state but also the density distribution of tablets produced by several manufacturers. TPI was also used to evaluate distinguishability among these tablets. The same waveform, which is a unique terahertz absorption spectrum derived from pure CPFX·HCl·H(2)O, was observed in all of the crushed tablets and in pure CPFX·HCl·H(2)O. TPI can provide information about the physical states of coated tablets. Information about the uniformity of parameters such as a coating thickness and density can be obtained. In this study, the authors investigated the coating thickness distributions of film-coated CPFX·HCl·H(2)O from four different manufacturers. Unique terahertz images of the density distributions in these commercial tablets were obtained. Moreover, B-scan (depth) images show the status of the coating layer in each tablet and the density map inside the tablets. These features would reflect differences resulting from different tablet-manufacturing processes.

7.
Magn Reson Chem ; 42(3): 313-20, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-14971016

RESUMO

We recorded both carbon-13 and nitrogen-15 NMR spectra of the three solid forms of sulfanilamide most commonly known. This study led to an interpretation of the solid-state effects seen in cross-polarization magic angle spinning spectra. Relaxation times for the different forms were measured. These show different behaviour for the three forms, arising from mobility variations. To obtain information on local environments, static spectra and spinning sideband manifolds were recorded and analysed for the 15N resonances, using isotopically enriched samples. Shielding asymmetries and anisotropies for the two nitrogen nuclei were obtained, showing very different behaviour for the two sites. Shielding calculations were carried out for both 13C and 15N nuclei, and the results are discussed in relation to the experimental values.


Assuntos
Sulfanilamidas/química , Anisotropia , Calibragem , Isótopos de Carbono , Ligação de Hidrogênio , Isomerismo , Espectroscopia de Ressonância Magnética , Modelos Moleculares , Conformação Molecular , Isótopos de Nitrogênio , Sulfanilamida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA