Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Esthet Restor Dent ; 36(1): 197-206, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37975525

RESUMO

OBJECTIVE: Despite the wide clinical use of translucent zirconia for full-arch implant prostheses, reduced flexural strength and fracture toughness compared with high-strength opaque zirconia needs to be addressed. A novel proof of concept for FP1 full-arch prosthesis featured by translucent monolithic zirconia and titanium framework was presented. CLINICAL CONSIDERATIONS: Computer-guided implant planning and surgery were executed and digitally designed FP1 temporary prosthesis prefabricated. Implant and prosthetic placement were achieved with a set of three-dimensional (3D)-printed templates. Implants were immediately loaded. After 4 months intraoral optical scan was taken to record implant coordinates, soft tissue anatomy, and temporary FP1 prosthesis. A novel digital workflow was used to design and mill overlaying translucent zirconia and anatomically shaped titanium framework with a scalloped soft-tissue interface. Final FP1 prosthesis was assembled cementing zirconia jacket on titanium counterpart. CONCLUSIONS: Translucent zirconia supported by titanium framework can address esthetic and mechanical requirements of FP1 full-arch prosthesis, minimizing risk of fracture and providing a rigid and passive joint with supporting implants. The smooth and highly polished titanium surface with an anatomic design, tightly matching scalloped soft tissue interface, can limit food impaction, air and saliva leakage and contribute to overall biologic integration of FP1 full-arch prosthesis. CLINICAL SIGNIFICANCE: Translucent monolithic zirconia featured with anatomically shaped titanium framework with scalloped transmucosal part, combining a pleasant esthetic outcome with increased flexural strength and fracture toughness, may be indicated to increase the clinical performance of FP1 full-arch prosthesis.


Assuntos
Produtos Biológicos , Implantes Dentários , Titânio , Desenho Assistido por Computador , Prótese Dentária Fixada por Implante , Estética Dentária , Zircônio
2.
Clin Oral Implants Res ; 34(4): 351-366, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36760035

RESUMO

PURPOSE: To retrospectively assess clinical and radiographic outcomes of immediately loaded full-arch fixed prostheses supported by axial and tilted implants up to 15 years of function. MATERIALS AND METHODS: Patients with one completely edentulous arch received an immediate full-arch fixed prosthesis supported by two anterior axial and two posterior tilted implants. Definitive prosthesis consisting of a CAD-CAM titanium framework and acrylic teeth was delivered 6 months later. Patients were regularly followed to assess clinical parameters and marginal bone level (MBL) change. Multilevel regression analysis was performed to investigate factors affecting implant failure and MBL. RESULTS: Six hundred ninety-two implants were placed in 72 maxillae and 101 mandibles. Seven maxillary implants (5 axial and 2 tilted) in 6 patients and 12 mandibular implants (6 axial and 6 tilted) in 5 patients failed. 15-year cumulative implant survival was 97.51% and 96.91% in maxilla and mandible, respectively (p = .64). After 10 years, the difference in MBL between axial and tilted implants was not significant in the maxilla (p = .47, 65 patients), while it was in the mandible (p < .001, 80 patients). Significant higher bone loss was reported in the mandible at both 5- and 10-year follow-up (p < .001 and p = .004, respectively). Mixed-effect multilevel linear regression evidenced a correlation between arch and bone loss at 5- and 10-year follow-up, while no correlation was found with age, gender, smoking, diabetes, and history of periodontal disease. CONCLUSION: This long-term study suggests that the present technique can be considered a viable treatment modality for the immediate rehabilitation of both maxilla and mandible.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Arcada Edêntula , Humanos , Estudos Retrospectivos , Seguimentos , Planejamento de Prótese Dentária , Arcada Edêntula/cirurgia , Arcada Edêntula/reabilitação , Prótese Dentária Fixada por Implante , Carga Imediata em Implante Dentário/métodos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-37994685

RESUMO

OBJECTIVE: This scoping review aimed to (1) critically evaluate the outcomes measures used to assess the accuracy of implant placement with Computer Assisted Implant Surgery (CAIS) and (2) review the evidence supporting the efficient implementation of CAIS in training and education of clinicians. METHODS: A scoping literature review was conducted aiming to identify (a) clinical trials assessing accuracy of implant placement with CAIS, and (b) clinical trials or simulation/cadaver studies where CAIS was utilised and assessed for the training/education of clinicians. Studies since 1995 were assessed for suitability and data related to the outcomes measures of accuracy and educational efficacy were extracted and synthesised. RESULTS: Accuracy of CAIS has been mainly assessed through surrogate measures. Individual clinical trials have not shown any difference between static and dynamic CAIS, but recent meta-analyses suggest an advantage of dynamic CAIS in reducing angular deviation. The combination of static and dynamic CAIS might offer higher accuracy than each of the two used alone. Dynamic CAIS is suitable for novice surgeons and might even have added value as an education tool for implant surgery, although mastering the technique requires longer training than static. CONCLUSION: Meta-analyses of large samples, new and diverse outcomes measures, as well as benchmarking of levels of accuracy with specific clinical outcomes will help to better understand the potential and limitations of CAIS. Dynamic CAIS is suitable for novice operators, but educational interventions distributed over longer periods of time will be required for mastery of the process.

4.
Clin Oral Implants Res ; 34(10): 1106-1117, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37485737

RESUMO

OBJECTIVES: To assess accuracy of intraoral optical scanning (IOS) and stereophotogrammetry (SPG), complete-arch digital implant impressions in vivo. MATERIALS AND METHODS: Consecutive patients needing implant-supported screw-retained zirconia complete-arch fixed-dental prostheses (ISZ-FDP) were recruited. For each patient, three impressions were taken: IOS, SPG (tests), and open-tray plaster (reference). Linear (ΔX, ΔY, and ΔZ), three-dimensional (ΔEUC), and angular deviations (ΔANGLE) were evaluated and stratified according to scanning technology for each implant. Potential effects of impression device (IOS and SPG), arch (maxilla and mandible), and implant number (4 and 6) were evaluated through multivariable analysis. Significance level was set at .05. RESULTS: A total of 11 complete arches (5 maxillae, 6 mandibles) in 11 patients were rehabilitated with ISZ-FDPs supported by 4 (n = 8) and 6 implants (n = 3). A total of 50 implants and 100 implant positions were captured by two investigated devices and compared to respective reference (mean ΔEUC IOS 137.2, SPG 87.6 µm; mean ΔANGLE 0.79, 0.38°). Differences between measurements (SPG-IOS) were computed for each implant, with negative values indicating better SPG accuracy. Significant mean ΔEUC difference of -49.60 µm (p = .0143; SD 138.15) and mean ΔANGLE difference of -0.40° (p < .0001; SD 0.65) were observed in favor of SPG. Multivariable analysis showed significant effect on ΔEUC (p = .0162) and ΔANGLE (p = .0001) only for impression devices, with SPG performing better. CONCLUSIONS: SPG experienced significantly higher linear and angular accuracy. No effect of type of arch or implant number was detected. Higher extreme deviations were experienced for IOS. SPG can be feasible for complete-arch digital impressions with caution, and rigid prototype try-in is recommended before screw-retained prosthesis manufacturing.

5.
J Prosthet Dent ; 129(1): 96-108, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34187699

RESUMO

STATEMENT OF PROBLEM: Despite the broad clinical application of zirconia for fixed implant-supported prostheses, evidence of long-term performance is sparse. PURPOSE: The purpose of this retrospective study was to evaluate the long-term clinical and radiographic outcomes of zirconia-based partial and complete screw-retained implant-supported zirconia fixed dental prostheses (ISZFDPs). MATERIAL AND METHODS: Records of patients treated with dental implants and ISZFDPs between December 2004 and June 2017 were screened. Eligible study participants, according to inclusion criteria, were contacted and invited to undergo clinical and radiographic examinations. Outcomes were evaluated as implant and prosthetic survival rates, prosthetic success rate, complications, marginal bone level (MBL) change, and soft tissue condition. Along with the effects of zirconia prosthesis type and level, the effects of implant type and connection, type of loading, and follow-up on MBL were tested with a generalized linear effects model (GLEM) (α=.05). RESULTS: A total of 118 patients were identified, of whom 20 (16.9%) were not available for clinical examination for various reasons. Ninety-eight participants (mean age 60.7 ±11.7 years) with 337 implants were included, of which 176 (52.2%) had been immediately loaded. A total of 111 ISZFDPs (96 zirconia connection and 15 titanium base) were investigated: 24 complete ISZFDPs with a zirconia connection (12.9 ±0.97 dental units, minimum 12, maximum 14), 72 partial with a zirconia connection (3.11 ±1.12, minimum 2, maximum 7), 15 partial with a titanium base (3.62 ±1.02, minimum 2, maximum 5). Forty ISZFDPs had been in function for ≥10 years (36%), 38 for 5 to 9 years (34.2%), and 33 for 2 to 4 years (22.8%). The mean follow-up time was 7.2 ±3.4 years. No zirconia fractures were identified. Two implants and 2 ISZFDPs failed, with chipping being the most common complication (13.5%). The implant survival rate was 99.4%, and the prosthetic survival rate was 98.2%. The cumulative prosthetic success rate was 91.9%. MBL change was -0.18 ±0.59 mm. Thirteen implants were treated for peri-implantitis (3.8%), and 9 for mucositis (2.7%), but presented healthy peri-implant soft tissues at the follow-up examination. A significant difference was found between the implant-level and abutment-level prostheses (P=.013), with less marginal bone loss observed in ISZFDPs delivered at the implant level. CONCLUSIONS: Zirconia-based screw-retained implant-supported prosthesis can be considered a reliable long-term treatment option for partial and complete edentulism. No zirconia fractures were experienced. Stable bone levels and low peri-implantitis rates were reported regardless of the ISZFDP type and level, implant type and connection, and type of loading.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Titânio , Falha de Restauração Dentária , Parafusos Ósseos , Prótese Dentária Fixada por Implante
6.
Int J Comput Dent ; 26(1): 19-28, 2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-35072425

RESUMO

AIM: To evaluate the trueness of seven different intraoral scanners (IOSs) in making a complete-arch digital scan with and without splinting the scan bodies. MATERIALS AND METHODS: A polyurethane cast of an edentulous mandible with four dental implant analogs was prepared. A reference scan was made using a laboratory scanner. The reference model was scanned with each of the seven investigated IOSs (control groups, n = 10 per scanner), and scanned again after splinting the scan bodies (study groups, n = 10 per scanner). Each scan was exported as a standard tessellation language (STL) file and transferred to a comprehensive metrology software program (Geomagic Control X). In order to measure the trueness, four points (A, B, C, and D) were determined on the scan bodies, and the distance between point A and the other points (DAB, DAC, and DAD) was measured. The measurements were tested for normality using the Kolmogorov-Smirnov test and probability plots. Trueness was compared using three-way analysis of variance (ANOVA), and pairwise comparisons were performed using the post hoc Tukey and paired sample t tests. Statistical analyses were two-sided, and the significance level was set at 5%. RESULTS: Splinting the scan bodies improved the trueness values of the digital scans, while increasing the interimplant distance decreased them. A significant association was found between the trueness values and all three tested variables, including splinting the scan bodies, type of IOS, and interimplant distance (P < 0.001). CONCLUSION: Based on the present findings, splinting the scan bodies can improve the trueness of complete-arch digital implant scans due to the improvement in morphologic landmarks by the stitching process, regardless of the type of IOS or the interimplant distance. (Int J Comput Dent 2023;26(1): 19-0; doi: 10.3290/j.ijcd.b2599297).


Assuntos
Implantes Dentários , Imageamento Tridimensional , Humanos , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Modelos Dentários
7.
Clin Oral Investig ; 26(4): 3593-3604, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34997359

RESUMO

OBJECTIVES: This open, single-cohort, multicenter, prospective study investigated the efficacy of immediately provisionalized tapered conical connection implant for single-tooth restorations in the anterior and premolar regions of the maxilla after 5 years of function. MATERIALS AND METHODS: All implants were placed in healed sites and immediately provisionalized. MBLs, soft-tissue parameters, and oral-health impact profile (OHIP) were evaluated at implant insertion, 6, 12, 24, 36, and 60 months. Paired Wilcoxon signed-rank tests and Kaplan-Meier survival analysis was used for statistical and implant survival/success analyses, respectively. RESULTS: Seventy-seven patients (81 implants) completed the 5-year follow-up. The 5-year cumulative survival and success rates were 97.8%, and the mean MBL change from implant insertion to 5 years was - 0.80 ± 1.13 mm. Optimal papilla index scores were observed at 90.1% of sites at 5 years compared with 32.8% of sites at insertion. Pink esthetic score, modified bleeding and plaque indices, and OHIP showed statistically significant improvement at the 5-year follow-up. CONCLUSIONS: Immediately provisionalized tapered conical connection implants promote marginal bone stability and excellent esthetic outcomes after 5 years of function. CLINICAL RELEVANCE: This treatment is a viable option for patients requiring immediately provisionalized single-tooth restorations in the esthetic zone and shows favorable long-term clinical outcomes, including marginal bone stability and excellent esthetics.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Planejamento de Prótese Dentária , Estética Dentária , Seguimentos , Humanos , Maxila/cirurgia , Estudos Prospectivos , Resultado do Tratamento
8.
J Esthet Restor Dent ; 34(1): 203-214, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34994995

RESUMO

OBJECTIVE: To assess clinical, radiological performance of novel navigation guided socket-shield technique (NSS) with immediate implant placement and loading. MATERIALS AND METHODS: Eighteen patients (12 females; age 52.54 ± 4.92; 33-72) treated between January 2018 and June 2019, were investigated, and followed for at least 1 year after definitive prosthesis placement (mean 20.1 months, 18-23). Primary outcomes: implant and prosthetic success rates, surgical, biologic, prosthetic complications. SECONDARY OUTCOMES: marginal bone loss (MBL), implant stability quotient (ISQ), pink esthetic score (PES), plaque and bleeding indexes. RESULTS: Sixty-nine navigation guided socket-shield procedures were performed (27 implant-sites and 42 pontic-sites) and 27 implants (NobelParallel, NobelBiocare AG) positioned and immediately loaded. Mean insertion torque and ISQ at implant positioning were 49 ± 5.34 Ncm (36-74), 73 ± 5.72 (68-81). No implant failure was experienced. Two root-shield exposures with mucositis, ulceration and bleeding were reported at two pontic-sites (2.9%) and successfully treated. No complications were experienced at implant-site leading to an overall NSS success-rate of 100%. No prosthetic complications occurred. Mean MBL was -0.72 ± 0.26 mm (-0.42 to -1.06 mm). PES final at the last follow-up 12.84 ± 0.92. The plaque and bleeding scores were 18.5 ± 6.12 and 3.15 ± 2.21. CONCLUSIONS: Within study limitations, dynamic navigation was effective to streamline execution of socket-shield technique at implant and pontic sites, shortening treatment time and reducing complications. Navigation guided socket-shield technique was reliable to achieve digitally planned shield-to-implant distance, facilitate immediate implant placement and loading and establish the mucosal dimension needed for underlying bone-to-implant protection and esthetic integration. CLINICAL SIGNIFICANCE: The investigated NSS technique overcomes the difficulties related to root preparation at implant and pontic-sites, facilitating immediate implant placement and loading. Dynamic guided surgery contributed to make socket-shield technique less technical-sensitive, shortening time for execution, reducing complication rate.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Pré-Escolar , Prótese Parcial Fixa , Estética Dentária , Feminino , Humanos , Carga Imediata em Implante Dentário/métodos , Estudos Prospectivos , Extração Dentária , Alvéolo Dental/cirurgia , Resultado do Tratamento
9.
Clin Oral Implants Res ; 32(12): 1397-1410, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34467555

RESUMO

OBJECTIVES: To evaluate clinical, radiological performance of novel digital workflow integrating dynamic navigation to streamline in one-visit single-implant immediate loading in aesthetic zone. MATERIAL AND METHODS: Consecutive patients requiring one single-implant in aesthetic zone of both jaws were treated between May and September 2017. Primary outcomes were implant and prosthetic success rates, surgical and prosthetic complications, marginal bone loss (MBL), final pink aesthetic score (PES-f), and implant stability quotient (ISQ-f). Secondary outcomes were ISQ-0 and PES-0 at implant positioning and PES-p at definitive prosthesis placement. Potential effect of jaw (maxilla vs mandible), biotype (thin vs thick), type of incision (flap vs flapless), and implant site (healed vs. post-extractive) on the primary outcomes (MBL, PES-f, and ISQ-f) was evaluated through a multivariable analysis. RESULTS: Fifty-two implants were placed (follow-up 18.6, 15-20 months). One post-extractive implant failed. No other surgical, biological complications occurred, accounting for 98.10% cumulative success rate (CSR). No definitive prostheses failed. Mean MBL was -0.63 ± 0.25 mm (-1.69 to -0.06). PES-f was 12.34 ± 1.41 (9-14). ISQ-f was 78.1 ± 3.2 (70-84). Age had significantly negative effect on MBL and PES-f (p = .0058 and p = .0052). No other variables significantly affected primary outcomes. CONCLUSIONS: Within study limitations, investigated digital workflow integrating dynamic navigation was reliable for single-implant immediate loading in aesthetic zone in one visit. No statistically significant difference was found for MBL, PES-f, and ISQ-f, considering type of incision (flap vs. flapless), implant site (healed vs post-extractive), jaw (maxilla vs. mandible), and biotype (thick vs. thin). Live-tracked dynamic navigation may have contributed to improve operator clinical performance regardless of implant site characteristics. Further investigations are needed to confirm positive outcomes.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Prótese Dentária Fixada por Implante , Estética Dentária , Seguimentos , Humanos , Maxila/cirurgia , Resultado do Tratamento , Fluxo de Trabalho
10.
J Esthet Restor Dent ; 33(1): 224-236, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33470044

RESUMO

OBJECTIVE: To assess clinical and radiological performance of novel digital workflow integrating dynamic guided surgery, to streamline execution of implant placement, soft and bone tissue sculpturing, and immediate delivery of navigation guided complete-arch prosthesis. MATERIALS AND METHODS: This proof of concept prospective single cohort study investigated 10 consecutive patients (three males, seven females; mean age 62.5 ± 8.9 years; range, 48-75) requiring at least one complete-arch fixed dental prostheses (FDP) in both jaws, treated between January and August 2019. Primary outcomes were implant and prosthetic success rates, surgical and prosthetic complications. Secondary outcomes were marginal bone loss (MBL), implant stability quotient (ISQ), periodontal parameters (plaque and bleeding indexes). RESULTS: Sixty implants (32 NobelParallel TiUltra and 28 NobelActive TiUltra, Nobel Biocare) were placed and 14 complete-arch FDPs immediately loaded (mean follow-up 16.2 ± 1.7 months, 14-18). One implant failed and was immediately replaced. No other surgical or biological complications occurred, accounting for a cumulative success rate of 98.3%. No prosthetic complication occurred, leading to 100% prosthetic success rate. Mean ISQ at implant placement was 71 ± 2.8 (65-78). The mean MBL was -0.53 ± 0.28 mm (-0.22 to -1.12 mm). Plaque and bleeding scores were 14.4 ± 8.18 and 7.15 ± 4.4, respectively. CONCLUSION: Within the limitations of this proof-of-concept dynamic navigation was effective to deliver in the planned coordinates both implants and prosthesis and guide bone and soft tissue sculpturing. Immediate loading of digitally prefabricated esthetically driven complete-arch FDP was facilitated, resulting in high implant and prosthetic success rates. CLINICAL SIGNIFICANCE: The investigated digital workflow integrating dynamic navigation may overcome the difficulties related to immediate positioning and loading of digitally prefabricated complete-arch FDP. The navigation guided soft and bone tissues sculpturing, associated to xenogeneic collagen matrix grafting, represented a predictable technique to achieve the digitally planned interface, reestablishing the mucosal dimension required for the protection of underlying bone while maintaining tissue health.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Idoso , Estudos de Coortes , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
11.
BMC Gastroenterol ; 20(1): 147, 2020 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-32398011

RESUMO

BACKGROUND: Incidence of ulcerative colitis (UC) in elderly population is increasing because of ageing and because of its minimal impact on life span. Data on natural history, outcomes and therapeutic strategies are limited. Our aim is to characterize UC in elderly-onset patients followed at our Inflammatory Bowel Disease outpatient clinic and compare with adult-onset UC. METHODS: From January 2000 to June 2019, 94 patients with UC diagnosed after the age of 65 years (elderly group, E-O) were identified and matched 1-1 according to gender and calendar year of diagnosis with patients diagnosed with UC at age between 40 and 64 years (adult age, A-O). RESULTS: Comorbidity Index (3.8 vs 1.6, p < 0.0005) was higher for elderly UC patients. Symptoms at presentation were similar between the two groups, although abdominal pain was more common in adults, and weight loss was more common in the elderly. At diagnosis, left colitis (61% vs 39%) and proctitis (14% vs 26%) (p = 0.011) were more frequent in the elderly. Therapy and clinical behaviour were similar. Surgery was more frequently performed in the elderly (20% vs 9%, p = 0.02), while biological therapy was less used (2.1% vs 22%, p < 0.0005). Complications were more frequent in the elderly. Extraintestinal manifestations were lower in elderly patients (9.6% vs 19.2%, p = 0.061). Time to first relapse was similar between the two groups. Mortality (p < 0.0005) was higher in elderly patients. CONCLUSIONS: Ulcerative Colitis has similar presentation and behaviour in elderly and adults patients. However, the elderly are more fragile because of comorbidities, increased risk of infections and disease-related complications.


Assuntos
Idade de Início , Colite Ulcerativa/patologia , Adulto , Idoso , Envelhecimento , Colite Ulcerativa/terapia , Comorbidade , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
12.
Clin Oral Investig ; 23(4): 1877-1885, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30225678

RESUMO

OBJECTIVES: This multicenter prospective clinical trial investigated immediately provisionalized, anodized, conical connection, tapered implants with platform shifting in maxillary anterior and premolar sites. MATERIALS AND METHODS: Patients requiring single-tooth implant-supported restorations in maxillary anterior and premolar sites were enrolled. Implants were immediately provisionalized and evaluated at insertion, 6 months, and annually thereafter. Outcome measures were marginal bone level change (ΔMBL), cumulative survival rate (CSR), and success rate, soft-tissue parameters, and oral health impact profile (OHIP). ΔMBL and Pink Esthetic Score were analyzed using Wilcoxon signed-rank tests. CSR was calculated using life table analysis. Other soft-tissue parameters were analyzed using sign tests. RESULTS: Of 94 enrolled patients (99 implants), 84 (88 implants) attended the 3-year follow-up. After an initial bone loss between implant insertion and 6 months (- 0.92 ± 1.23 mm), bone levels stabilized from 6 months to 3 years (0.13 ± 0.94 mm) with no significant change. The 3-year CSR was 98.9%, and the cumulative success rate was 96.9%. Papilla index scores of 2 or 3 were observed at 88.6% of sites at the 3-year visit compared with 32.8% at implant insertion. Improvements were observed for all other outcomes, including bleeding on probing, esthetics, plaque, and OHIP. CONCLUSIONS: This restorative protocol was associated with high primary stability, patient satisfaction, stable bone levels, and an overall improvement of the soft tissue outcomes over a 3-year period. CLINICAL RELEVANCE: The presented treatment is a viable option for single-tooth restorations of maxillary anterior teeth and premolars with successful short- to mid-long-term clinical outcomes.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Adolescente , Adulto , Idoso , Dente Pré-Molar , Estética Dentária , Feminino , Seguimentos , Humanos , Masculino , Maxila , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
13.
Clin Oral Investig ; 22(6): 2299-2308, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29397467

RESUMO

OBJECTIVES: The aim of this interim analysis of a 5-year prospective multicenter study is to evaluate clinical and radiological performance of immediately provisionalized 3.0-mm-diameter tapered implants. MATERIALS AND METHODS: Patients needing implant rehabilitation of maxillary lateral incisors or mandibular lateral and central incisors were treated with 3.0-mm-diameter implants placed in extraction or healed sites and immediately provisionalized. Clinical and radiographic examinations were performed at implant insertion, 6 months thereafter, and are ongoing. Marginal bone levels and changes, complications, the papilla, plaque, and bleeding indices, and the pink esthetic score (PES) were evaluated at each follow-up visit. RESULTS: Of 112 enrolled patients, 77 patients (91 implants) met the inclusion criteria. Seventy-one patients with 82 implants completed the 1-year follow-up. Three implants failed yielding a CSR of 96.7%. All failures occurred within the first 3 months after implant insertion. Marginal bone level changes from insertion to 6 months was - 0.57 ± 1.30 mm (n = 75) and from insertion to 12 months - 0.25 ± 1.38 mm (n = 72). Fifteen non-serious complications were recorded. Papilla index score and PES improved at the 1-year follow-up. Plaque formation and bleeding-on-probing showed no statistically significant differences between the 6-month and the 1-year visit. CONCLUSIONS: This 1-year analysis demonstrated high survival, stable bone levels, and healthy soft tissue with 3.0-mm-diameter implants. CLINICAL IMPLICATIONS: Narrow diameter implants are a safe and predictable treatment option in patients with limited bone volume and/or limited interdental space and eligible for immediate loading protocols.


Assuntos
Implantes Dentários para Um Único Dente , Estética Dentária , Carga Imediata em Implante Dentário/métodos , Adulto , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Feminino , Humanos , Incisivo , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos , Resultado do Tratamento
14.
Clin Oral Investig ; 21(6): 2133-2142, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27864641

RESUMO

OBJECTIVES: The aim of this multicenter prospective clinical study was to evaluate anodized tapered implants with a conical connection and integrated platform shifting placed in the anterior and premolar maxilla. MATERIALS AND METHODS: The study enrolled patients requiring single-tooth restorations in healed sites of maxillary anterior and premolar teeth. All implants were immediately temporized. Clinical and radiographic evaluations were conducted at implant insertion, 6 months, and 1 year. Outcome measures included bone remodeling, cumulative survival rate (CSR), success rate, soft-tissue health and esthetics, and patient satisfaction. Bone remodeling and pink esthetic score were analyzed using Wilcoxon signed-rank tests. CSR was calculated using life table analysis. Other soft-tissue outcomes were analyzed using sign tests. RESULTS: Out of 97 enrolled patients (102 implants), 87 patients (91 implants) completed the 1-year visit. Marginal bone remodeling was -0.85 ± 1.36 mm. After the expected initial bone loss, a mean bone gain of 0.11 ± 1.05 mm was observed between 6 months and 1 year. The CSR was 99.0%, and the cumulative success rate was 97.0%. Partial or full papilla was observed at 30.8% of sites at baseline, 87.2% at 6 months, and 90.5% at 1 year. Soft-tissue response, esthetics, and patient satisfaction all improved during the study period. CONCLUSIONS: Bone gain was observed following the expected initial bone loss, and soft-tissue outcomes improved suggesting favorable tissue response using anodized tapered conical connection implants. CLINICAL RELEVANCE: Rapid stabilization of bone remodeling and robust papilla regeneration indicate favorable tissue healing promoted by the conical connection, platform-shift design. TRIAL REGISTRATION: clinicaltrials.gov NCT02175550.


Assuntos
Remodelação Óssea/fisiologia , Coroas , Implantes Dentários para Um Único Dente , Prótese Dentária Fixada por Implante , Adolescente , Adulto , Idoso , Planejamento de Prótese Dentária , Estética Dentária , Feminino , Humanos , Carga Imediata em Implante Dentário , Tábuas de Vida , Masculino , Maxila/cirurgia , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Resultado do Tratamento
15.
J Prosthet Dent ; 116(4): 516-523, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27160781

RESUMO

STATEMENT OF PROBLEM: In patients with an altered skeletal maxillomandibular relationship and bone resorption, the rehabilitation of edentulous jaws by combining 4 implants, 2 straight medially and 2 tilted distally, may be preferred to avoid a bone augmentation procedure. PURPOSE: The purpose of this single cohort 1-year prospective study was to evaluate the clinical performance of a 4-implant overdenture fully supported by a computer-aided designed and computer-aided manufactured (CAD-CAM) titanium bar. MATERIAL AND METHODS: This single cohort prospective study included edentulous participants rehabilitated with a 4-implant overdenture in 1 of the 2 jaws. The outcomes were implant and prosthetic survival and success rates, any biologic and technical complications, periimplant marginal bone loss, changes in the oral health impact profile (OHIP), bleeding on probing, and the plaque index. RESULTS: Eighteen participants received 72 implants. One year after implant placement, no implants or prosthesis had failed, and no biologic or technical complications had been observed. At the 1-year follow-up, the mean marginal bone loss was 0.29 ±0.16 mm. The OHIP summary scores demonstrated a significant improvement in oral health-related quality of life. At the 1-year follow-up, positive bleeding was found in 2 participants (11.1%) around 3 implants (4.1%). Three participants (16.6%), accounting for 5 implants (6.9%), showed a slight amount of plaque. CONCLUSIONS: A 4-implant overdenture supported by a CAD-CAM titanium bar may be a reliable option for the treatment of the edentulous mandible and maxilla over a 1-year period. Oral health-related quality of life significantly improved in all treated participants.


Assuntos
Prótese Dentária Fixada por Implante/métodos , Revestimento de Dentadura , Idoso , Desenho Assistido por Computador , Falha de Restauração Dentária/estatística & dados numéricos , Planejamento de Dentadura , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Titânio
16.
Rheumatology (Oxford) ; 54(1): 96-103, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25096601

RESUMO

OBJECTIVES: The aims of this study were to determine whether micro-CT is a reliable investigation method to evaluate the severity of OA in the trapezium and to develop a novel micro-CT scoring system based on a quantitative assessment of the subchondral bone thickness in order to better assess OA through an objective parameter. METHODS: We compared different diagnostic and imaging techniques performed consecutively on each sample: X-ray, visual analysis, micro-CT and histology. OA and healthy trapezia were subjected to semi-quantitative and quantitative analyses to be classified in four degrees of severity in OA (control, OA-2, OA-3 and OA-4). Specifically, samples were analysed using Dell's score for X-ray, Brown's score for visual analysis and Mankin's score for histology. Micro-CT was scored using a novel quantitative scoring system based on subchondral bone thickness measurements. Results obtained with each technique were then compared and correlated. RESULTS: X-ray analysis showed a higher frequency of OA-2 (27%) and OA-3 (32%) compared with OA-4 (5%), whereas visual analysis, micro-CT and histology showed a lower percentage for OA-2 (18%, 18% and 14%) and OA-3 (23%) and increased frequency for OA-4 (45%, 32% and 40%). Only the micro-CT score of subchondral bone thickness correlated significantly with all the other techniques (P < 0.05). CONCLUSION: This is the first comparison of techniques proposing a novel scoring system based on objective and quantitative micro-CT data that can be applied as a useful diagnostic tool for OA, providing a deeper comprehension of the pathophysiology of OA in trapezium.


Assuntos
Osteoartrite/diagnóstico por imagem , Osteoartrite/patologia , Trapézio/diagnóstico por imagem , Trapézio/patologia , Microtomografia por Raio-X/métodos , Idoso , Estudos de Casos e Controles , Feminino , Histologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Raios X
17.
J Prosthodont Res ; 68(1): 172-180, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-37574278

RESUMO

PURPOSE: To assess and compare the accuracies of intraoral scanners (IOS) and stereophotogrammetry (SPG) devices for complete-arch digital implant impressions. METHODS: A 4-analog model was digitized using a desk scanner to obtain a reference file. Thirty test scans were conducted using the investigated IOS device, while an additional 30 scans were performed using the SPG device. Using the best-fit algorithm, the resulting 60 test files were aligned with the reference file. Linear (ΔX, ΔY, and ΔZ-axis) and angular deviations (ΔANGLE) were evaluated. Three-dimensional (3D) deviation was calculated based on the Euclidean distance (ΔEUC). The analysis was stratified according to the scanning device and implant position. Fisher's F and t-tests were used to compare the variances and expected values of the two scanning systems. RESULTS: IOS expressed a higher 3D (ΔEUC) mean deviation than SPG (52.8 µm vs. 33.4 µm, P < 0.0001), with extreme measurements up to 181.9 µm. A significantly higher standard deviation (SD) was associated with IOS (37.1 µm vs. 17.7 µm, P < 0.0001). Considering angular deviations, the IOS showed slightly higher angular mean deviations (ΔANGLE) than the SPG (0.28° vs. 0.24°, P = 0.0022), with extreme measurements of up to 0.73°. The SPG SD values were significantly lower than the IOS SD values (0.14° vs. 0.04°, P < 0.0001). CONCLUSIONS: The SPG showed significantly higher 3D and angular accuracies for complete arch implant impressions, with consistent repeatability. IOS scanning revealed significantly higher extreme deviations exceeding the acceptable threshold value. Despite study limitations, SPG appears more feasible than IOS for complete-arch digital implant impressions.


Assuntos
Implantes Dentários , Imageamento Tridimensional , Técnica de Moldagem Odontológica , Modelos Dentários , Desenho Assistido por Computador
18.
J Clin Med ; 12(12)2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37373841

RESUMO

The aim of this study was to assess intra-arch mandibular dimensional changes that may occur during mouth opening using cone beam-computed tomography (CBCT). Fifteen patients in need of any type of treatment whose execution considered a pre- and post-CBCT assessment consented and were enrolled. CBCTs were taken with the following settings: 90 kV, 8 mA, field of view (FOV) 140 by 100 mm (height and diameter), Voxel size 0.25 mm (high resolution). The pre-CBCT was executed in the maximum mandibular opening (MO), while the post-CBCT was in the maximum intercuspation (MI). A thermoplastic stent with radiopaque fiducial markers (steel ball bearings) was fabricated for each patient. Measurements were made using radiographic markers between contralateral canines and contralateral first molars and between ipsilateral canines and first molars on both sides. Paired t-tests were performed to evaluate the difference between open and closed positions on these four measurements. In the MO position were registered a significative tightening of the mandible at the canine (-0.49 mm, SD 0.54 mm; p < 0.001) and molar points (-0.81 mm, SD 0.63 mm; p < 0.001) and a significative shortening of the mandible on the right (-0.84 mm, SD 0.80 mm; p < 0.001) and left sides (-0.87 mm, SD 0.49 mm; p < 0.001). Within the study limitations, mandibular flexure determined a significant shortening and tightening between maximum intercuspation to maximum opening positions. Mandibular dimensional changes should be considered in light of other patient factors in the treatment planning of implant positioning and long-span complete arch implant-supported fixed prostheses in order to avoid technical complications.

19.
J Prosthet Dent ; 108(5): 286-97, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23107236

RESUMO

STATEMENT OF PROBLEM: In the posterior maxilla, tooth loss is usually associated with alveolar bone resorption and sinus pneumatization, limiting the placement of implants without grafting procedures. PURPOSE: The purpose of this study was to evaluate a minimally invasive treatment of the atrophic posterior maxilla, with axial and tilted implants and immediate loading. The research hypothesis was that the combination of a guided, minimally invasive approach and the biomimetic features of computer-aided design and computer-aided manufacturing (CAD/CAM) abutments would be an effective alternative to maxillary sinus floor augmentation procedures with reduced bone resorption around implants. MATERIAL AND METHODS: Twenty-seven consecutive participants (female=12, male=15) (mean age 54.18 years) with severe atrophy of the posterior maxilla were treated by using guided surgery with immediately loaded axial (39) and tilted (42) implants supporting CAD/CAM zirconia (39) and titanium (42) abutments (81 total) and partial fixed prostheses. Each participant underwent a computed tomography scan, after which 2 or 3 implants were positioned with a flapless or miniflap approach. The drilling protocol was adapted to the bone density of each implant site to obtain an insertion torque ranging between 40 and 50 Ncm. CAD/CAM customized abutments composed of zirconia or titanium were fixed to the implants with prosthetic screws tightened with a torque of 35 Ncm. An acrylic resin interim restoration reinforced with metal was placed immediately. Five to 6 months after initial loading, a zirconia framework was manufactured, and a definitive prosthesis was placed. Clinical and radiological controls were performed at baseline and after 1 and 3 years to assess implant and prosthesis survival and success rate and compare marginal bone remodeling of axial and tilted implants. Inferential statistics for radiological data were acquired by using the Mann-Whitney U-test. All statistical comparisons were conducted at the .05 significance level. RESULTS: The mean follow-up period was 43.3 months (ranging from 36 months to 54 months). The cumulative implant survival rate was 96.3% at 3 years. All prosthetic restorations were stable and in good function, resulting in a cumulative prosthetic survival rate of 100%. Three restorations had chipping of the veneer material; thereafter, the cumulative prosthetic success rate was 91.9%. CONCLUSIONS: Treatment of the posterior partially edentulous atrophic maxilla with guided surgery and immediate loading of tilted and straight implants supporting short-span partial fixed dental prostheses is effective.


Assuntos
Perda do Osso Alveolar/cirurgia , Dente Suporte , Implantação Dentária Endóssea/métodos , Carga Imediata em Implante Dentário , Cirurgia Assistida por Computador , Adulto , Idoso , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Feminino , Humanos , Masculino , Doenças Maxilares/cirurgia , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Prospectivos , Estatísticas não Paramétricas
20.
Materials (Basel) ; 15(4)2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35208002

RESUMO

The aim of this study was to systematically review the current scientific literature regarding the accuracy of fully guided flapless implant positioning for complete-arch rehabilitations in edentulous patients and to assess if there was any statistically significant correlation between linear deviation at shoulder point, at apex point and angular deviation. The electronic and manual literature search of clinical studies was carried out using specified indexing terms. A total of 13 studies were eligible for qualitative analysis and 277 edentulous patients were rehabilitated with 1556 implants patients by means of fully guided mucosa-supported template-assisted flapless surgery. Angular deviation was 3.42° (95% CI 2.82-4.03), linear deviation at shoulder point 1.23 mm (95% CI 0.97-1.49) and linear deviation at apex point 1.46 mm (95% CI 1.17-1.74). No statistically significant correlations were found between the linear and angular deviations. A statistically significant correlation was found between the two linear deviations (correlation coefficient 0.91) that can be summarized by the regression equation y = 0.03080 + 0.8254x. Computer-assisted flapless implant placement by means of mucosa-supported templates in complete arch restorations can be considered a reliable and predictable treatment choice despite the potential effects that flapless approach could bring to the overall treatment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA