Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 39(8): 2100-2103, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38423259

RESUMO

BACKGROUND: Preoperative intra-articular corticosteroid injections to the hip joint increase the risk of periprosthetic joint infection (PJI) during primary total hip arthroplasty (THA). This study aimed to determine the relationship between preoperative timing of intra-articular corticosteroid injections and PJI risk following THA using data from a single-center hospital. METHODS: This single-center, retrospective cohort study included patients who underwent a THA between 2014 and 2020. Medical records were checked for intra-articular corticosteroid injections and PJI within 1 year of surgery. Patients were categorized into groups based on whether they received "no injection" or "injection 0 to 3 months," "3 to 6 months," and "> 6 months prior to THA." Hazard ratios (HRs) for these groups were calculated using multivariate Cox regression analysis, correcting for potential confounders, and presented with 95% confidence intervals [95% CIs]. RESULTS: In total, 4,507 patients (5,909 THAs) were identified. A total of 1,581 patients (27%) received an injection prior to THA. Without considering the timing factor, no increased risk for PJI following an intra-articular injection was noted (P = .19). Comparing the specified groups using multivariate analysis, corticosteroid injection within 3 months of THA showed an increased risk of PJI (HR 2.63, 95% CI 1.18 to 5.87, P = .018), but this effect was not observed for the "injection 3 to 6 months" group (HR 1.51, 95% CI 0.74 to 3.08, P = .264). CONCLUSIONS: Corticosteroid injections administered up to 3 months prior to THA increased the risk of PJI within 1 year after THA, with an HR of 2.63; however, injections between 3 and 6 months before surgery did not have a significantly higher infection rate.


Assuntos
Corticosteroides , Artroplastia de Quadril , Infecções Relacionadas à Prótese , Humanos , Artroplastia de Quadril/efeitos adversos , Injeções Intra-Articulares , Masculino , Feminino , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Corticosteroides/administração & dosagem , Corticosteroides/efeitos adversos , Cuidados Pré-Operatórios/métodos , Articulação do Quadril/cirurgia , Fatores de Tempo , Idoso de 80 Anos ou mais
2.
Molecules ; 29(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38731611

RESUMO

Solvents prepared from natural terpenes (menthol and thymol), as H-bond acceptors, and a series of organic acids (chain lengths of 8, 10, and 14 C atoms), as H-bond donors, were characterized and tested as reaction media for liquid-liquid extraction purposes. Due to their high hydrophobicity, they seem to be promising alternatives to conventional (nonpolar and toxic) solvents, since they possess relatively less toxic, less volatile, and consequently, more environmentally friendly characteristics. Assuming that the equilibrium is established between solvent and analyte during a ligandless procedure, it can be concluded that those nonpolar solvents can efficiently extract nonpolar analytes from the aqueous environment. Previous investigations showed a wide range of applications, including their use as solvents in extractions of metal cations, small molecules, and bioactive compounds for food and pharmaceutical applications. In this work, hydrophobic solvents based on natural terpenes, which showed chemical stability and desirable physicochemical and thermal properties, were chosen as potential reaction media in the liquid-liquid extraction (LLE) procedure for Pb(II) removal from aqueous solutions. Low viscosities and high hydrophobicities of prepared solvents were confirmed as desirable properties for their application. Extraction parameters were optimized, and chosen solvents were applied. The results showed satisfactory extraction efficiencies in simple and fast procedures, followed by low solvent consumption. The best results (98%) were obtained by the thymol-based solvent, thymol-decanoic acid (Thy-DecA) 1:1, followed by L-menthol-based solvents: menthol-octanoic acid (Men-OctA) 1:1 with 97% and menthol-decanoic acid (Men-DecA) 1:1 with 94.3% efficiency.

3.
Molecules ; 28(7)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37049660

RESUMO

Plant extracts are increasingly being examined in the corrosion inhibition of metal and alloys in various environments due to their potent antioxidant properties. The use of Artemisia annua L. aqueous extract (AAE) as an aluminium alloy 5083 (ALA) corrosion inhibitor in artificial seawater (ASW) was investigated using electrochemical tests and spectroscopy tools, while the active biocompounds found in AAE were analyzed using high-performance liquid chromatography (HPLC). Electrochemical results showed that AAE acts as an anodic inhibitor through the physisorption (ΔG ≈ -16.33 kJ mol-1) of extract molecules on the ALA surface, thus reducing the active sites for the dissolution of the alloy in ASW. Fourier-transform infrared spectra confirmed that phenolic acids found in AAE formed the surface layer that protects ALA against the corrosive marine environment, while HPLC analysis confirmed that the main phytoconstituents of AAE were chlorogenic acid and caffeic acid. The inhibition action of phenolic acids and their derivatives found in the AAE was based on the physisorption of caffeic acid on the ALA surface, which improved physicochemical properties of the barrier film and/or conversion of Al3+ to elemental aluminium by phenolic acids as reducens, which slowed down the diffusion rate of Al3+ to or from the ALA surfaces. The protective effect of the surface layer formed in the presence of AAE against ASW was also confirmed by inductively coupled plasma-optical emission spectrometry (ICP-OES) whereby the measured concentration of Al ions after 1 h of immersion of ALA in the pure ASW was 15.30 µg L-1 cm-2, while after the addition of 1 g L-1 AAE, the concentration was 3.09 µg L-1 cm-2.


Assuntos
Ligas , Artemisia annua , Ligas/química , Alumínio , Corrosão , Água do Mar
4.
Environ Geochem Health ; 45(12): 9855-9873, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37864130

RESUMO

Acid mine drainage (AMD) is generally outlined as one of the largest environmental concerns, characterized by very low pH value of mine waste, heavy metals and high sulphate content. This extremely hostile environment reduces plant ability to develop and grow. Present study focuses on a silver birch (Betula pendula Roth), a pioneer species that grows on an extremely hostile gold mine waste, to investigate the bioaccumulation of rare metals (thallium (Tl) and indium (In)), as well as nine other more common heavy metals (bismuth (Bi), cadmium (Cd), cobalt (Co), copper (Cu), lead (Pb), manganese (Mn), nickel (Ni), silver (Ag) and zinc (Zn)), and to asses phytoextraction and phytostabilization potential of silver birch. Additionally, parameters determining AMD process and overall contamination (pH, electrical conductivity (EC), sulphates (SO42-), arsenic (As), iron (Fe), oxidation-reduction potential (ORP), turbidity, dissolved oxygen (DO), total dissolved solids (TDS), acidity, hardness, X-ray diffraction (XRD) and radioactivity) were determined in mine waste and drainage water samples. To assess the heavy metals bioaccumulation and mine waste status, statistical geochemical indices were determined: bioaccumulation factor (BCF), pollution load index (PLI), geochemical abundance index (GAI) and exposure index (EI). The results show that silver birch bioaccumulates the essential elements Cu, Ni, Mn and Zn, and the nonessential elements Tl (average BCF = 24.99), In (average BC = 23.01) and Pb (average BCF = 0.84). Investigated mine waste was enriched by Bi, Ag and Cd according to positive values of GAI index. Present research provides a novel insight into bioaccumulation of nonessential heavy metals in silver birches who grow on the extremely hostile mine waste, and they exhibit significant phytoremediation potential.


Assuntos
Betula , Metais Pesados , Ouro , Cádmio , Bioacumulação , Chumbo , Metais Pesados/análise , Zinco , Manganês , Monitoramento Ambiental
5.
Molecules ; 27(17)2022 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-36080233

RESUMO

Considering the vast cultural and traditional heritage of the use of aromatic herbs and wildflowers for the treatment of light medical conditions in the Balkans, a comparison of the antioxidant capacity of wildflowers extracts from Herzegovina was studied using both cyclic voltammetry and spectrophotometry. The cyclic voltammograms taken in the potential range between 0 V and 800 mV and scan rate of 100 mV s-1 were used for the quantification of the electrochemical properties of polyphenols present in four aqueous plant extracts. Antioxidant capacity expressed as mmoL of gallic acid equivalents per gram of dried weight of the sample (mmoL GAE g-1 dw) was deduced from the area below the major anodic peaks (Q400 pH 6.0, Q500 pH 4.7, Q600 pH 3.6). The results of electrochemical measurements suggest that the major contributors of antioxidant properties of examined plants are polyphenolic compounds that contain ortho-dihydroxy-phenol or gallate groups. Using Ferric reducing-antioxidant power (FRAP) and 2,2'-azino-bis spectrophotometric methods (3-ethylbenzthiazoline-6-sulphonic acid) radical cation-scavenging activity (ABTS) additionally determined antioxidant capacity. The FRAP results ranged from 2.9702-9.9418 mmoL Fe/g dw, while the results for ABTS assays expressed as Trolox equivalents (TE) ranged from 14.1842-42.6217 mmoL TE/g dw. The Folin-Ciocalteu procedure was applied to determine the total phenolics content (TP). The TP content expressed as Gallic acid equivalents (GAE) ranged from 6.0343-9.472 mmoL GAE/g dw. The measurements of total flavonoid (TF) and total condensed tannin (TT) contents were also performed to obtain a broader polyphenolic profile of tested plant materials. Origanum vulgare L. scored the highest on each test, with the exception of TT content, followed by the Mentha × piperita L., Artemisia annua L., and Artemisia absinthium L., respectively. The highest TT content, expressed as mg of (-)catechin equivalents per gram of dried weight of sample (mg CE/g dw), was achieved with A. absinthium extract (119.230 mg CE/g dw) followed by O. vulgare (90.384 mg CE/g dw), A. annua (86.538 mg CE/g dw) and M. piperita (69.231 mg CE/g dw), respectively. In addition, a very good correlation between electrochemical and spectroscopic methods was achieved.


Assuntos
Antioxidantes , Extratos Vegetais , Antioxidantes/química , Flavonoides/química , Ácido Gálico/análise , Humanos , Fenóis/química , Extratos Vegetais/química , Polifenóis/análise
6.
Sensors (Basel) ; 22(1)2021 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-35009839

RESUMO

The solid-state ion-selective electrodes presented here are based on the FePO4:Ag2S:polytetrafluoroethylene (PTFE) = 1:1:2 with an addition of (0.25-1)% microwave-synthesized hematite (α-Fe2O3), magnetite (Fe3O4), boehmite [γ-AlO(OH)], and alumina (Al2O3) nanoparticles (NPs) in order to establish ideal membrane composition for iron(III) cations determination. Synthesized NPs are characterized with Fourier-Transform Infrared (FTIR) spectroscopy, Powder X-Ray Diffraction (PXRD), and Scanning Electron Microscopy (SEM) with Energy Dispersive Spectroscopy (EDS). The iron oxides NPs, more specifically, magnetite and hematite, showed a more positive effect on the sensing properties than boehmite and alumina NPs. The hematite NPs had the most significant effect on the linear range for the determination of ferric cations. The membrane containing 0.25% hematite NPs showed a slope of -19.75 mV per decade in the linear range from 1.2∙10-6 to 10-2 mol L-1, with a correlation factor of 0.9925. The recoveries for the determination of ferric cations in standard solutions were 99.4, 106.7, 93.6, and 101.1% for different concentrations.

7.
Sensors (Basel) ; 21(5)2021 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-33668940

RESUMO

A novel ion-selective electrode with membranes based on iron(III) phosphate and silver sulfide integrated into a completely new electrode body design has been developed for the determination of iron(III) cations. The best response characteristics with linear potential change were found in the iron(III) concentration range from 3.97 × 10-5 to 10-2 mol L-1. The detection limit was found to be 2.41 × 10-5 mol L-1 with a slope of -20.53 ± 0.63 and regression coefficient of 0.9925, while the quantification limit was 3.97 × 10-5 M. The potential change per concentration decade ranged from -13.59 ± 0.54 to -20.53 ± 1.56 for Electrode Body 1 (EB1) and from -17.28 ± 1.04 to -24 ± 1.87 for Electrode Body 2 (EB2), which is presented for the first time in this work. The prepared electrode has a long lifetime and the ability to detect changes in the concentration of iron cations within 20 s. Membrane M1 showed high recoveries in the determination of iron cations in iron(III) standard solutions (98.2-101.2%) as well as in two different pharmaceuticals (98.6-106.5%). This proves that this type of sensor is applicable in the determination of ferric cations in unknown samples, and the fact that all sensor parts are completely manufactured in our laboratory proves the simplicity of the method.

8.
Molecules ; 26(12)2021 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-34205735

RESUMO

Micellar systems are colloids with significant properties for pharmaceutical and food applications. They can be used to formulate thermodynamically stable mixtures to solubilize hydrophobic food-related substances. Furthermore, micellar formation is a complex process in which a variety of intermolecular interactions determine the course of formation and most important are the hydrophobic and hydrophilic interactions between surfactant-solvent and solvent-solvent. Glycols are organic compounds that belong to the group of alcohols. Among them, propane-1,2-diol (PG) is a substance commonly used as a food additive or ingredient in many cosmetic and hygiene products. The nature of the additive influences the micellar structure and properties of sodium dodecyl sulfate (SDS). When increasing the mass fraction of propane-1,2-diol in binary mixtures, the c.m.c. values decrease because propane-1,2-diol is a polar solvent, which gives it the ability to form hydrogen bonds, decreasing the cohesivity of water and reducing the dielectric constant of the aqueous phase. The values of ΔGm0 are negative in all mixed solvents according to the reduction in solvophobic interactions and increase in electrostatic interaction. With the rising concentration of cosolvent, the equilibrium between cosolvent in bulk solution and in the formed micelles is on the side of micelles, leading to the formation of micelles at a lower concentration with a small change in micellar size. According to the 1H NMR, with the addition of propylene glycol, there is a slight shift of SDS peaks towards lower ppm regions in comparison to the D2O peak. The shift is more evident with the increase in the amount of added propane-1,2-diol in comparison to the NMR spectra of pure SDS. Addition of propane-1,2-diol causes the upfield shift of the protons associated with hydrophilic groups, causing the shielding effect. This signifies that the alcohol is linked with the polar head groups of SDS due to its proximity to the SDS molecules.

9.
J Cosmet Sci ; 72(3): 292-297, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35361317

RESUMO

Tinctures are alcoholic or hydroalcoholic solutions prepared from vegetable or chemical substances. The concentration of the solute varies up to a maximum of 50%, e.g., vanilla tincture. Tinctures are very useful in the perfume industry because they contain ethanol, which can dissolve molecules such as fragrant molecules, and consequently form hydroalcoholic formulations together. Recently, we have shown that nanostructures exist in the monophasic water-ethanol-citronellol system, and it is therefore a question whether such nanostructures exist in a system where a perfume molecule of citral is present as the oil component instead of citronellol. In this study, the single-phase region was mapped conductometrically and then measured by Dynamic Light Scattering (DLS) and UV/Vis spectroscopy to determine the presence of nanostructures similar to classical microemulsions.


Assuntos
Perfumes , Tensoativos , Emulsões/química , Odorantes , Tensoativos/química , Água/química
10.
Molecules ; 25(21)2020 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-33182383

RESUMO

A new modified ion-selective electrode with membranes of LaF3 single crystals with different internal contacts (solid steel or electrolyte) and with FexOy nanoparticles as loading was developed. The best response characteristic with linear potential change was found in the fluoride concentration range from 10-1 to 3.98 × 10-7 M. The detection limit for the electrolyte contact was determined at 7.41 × 10-8 M with a regression coefficient of 0.9932, while the regression coefficient for the solid contact was 0.9969. The potential change per concentration decade ranged from 50.3 to 62.4 mV, depending on whether the contact was solid or electrolytic. The prepared modified electrode has a long lifetime, as well as the possibility of application in different positions (solid contact), and it can also be used for the determination of iron ions. The electrode characterization was performed with scanning electron microscopy and elemental analysis with the technique of electron-dispersive X-ray spectroscopy.


Assuntos
Eletrodos , Fluoretos/química , Íons , Nanopartículas Metálicas/química , Nanotecnologia/métodos , Concentração de Íons de Hidrogênio , Lantânio/química , Limite de Detecção , Modelos Lineares , Metais/química , Microscopia Eletrônica de Varredura , Espectroscopia Fotoeletrônica , Potenciometria/métodos
11.
J Shoulder Elbow Surg ; 28(10): 2017-2022, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31202625

RESUMO

BACKGROUND: Total elbow arthroplasty (TEA) is a relatively infrequently performed procedure. Therefore, nationwide databases help to provide more insight into factors that might influence implant survival, for example, the surgical approach used. Using data from the Dutch Arthroplasty Register, we aimed to reveal whether high-volume centers use different approaches than low-volume centers and whether the approach is implant specific. METHODS: Using data from 2014 to 2017, we compared the surgical approaches used for high- vs. low-volume centers, as well as for the 2 most frequently used types of TEA, by use of χ2 tests. RESULTS: We analyzed 276 procedures. In 2016 and 2017, when posterior approaches were further specified, the triceps-on approach was used most frequently in the high-volume center (27 of 42 procedures, 64%) and the triceps-flap approach was used most often in the low-volume centers (48 of 84 procedures, 57%) (P < .001). For the 2 most frequently used types of TEA, the Coonrad-Morrey and Latitude EV arthroplasties, the surgical approaches did not differ. When the high-volume center was compared with the low-volume centers, implant choice differed, with the Coonrad-Morrey arthroplasty being most often used in the high-volume center and the Latitude EV arthroplasty, in the low-volume centers. CONCLUSION: The posterior triceps-flap approach was the most frequently used surgical approach in primary TEA in the Netherlands, yet the triceps-on approach was used more often in the high-volume center. The surgical approaches did not differ between the 2 most frequently used types of TEA in the Netherlands.


Assuntos
Artroplastia de Substituição do Cotovelo/instrumentação , Artroplastia de Substituição do Cotovelo/métodos , Articulação do Cotovelo/cirurgia , Hospitais com Alto Volume de Atendimentos/estatística & dados numéricos , Hospitais com Baixo Volume de Atendimentos/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Prótese de Cotovelo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/cirurgia , Países Baixos , Sistema de Registros , Retalhos Cirúrgicos , Adulto Jovem
12.
J Shoulder Elbow Surg ; 27(7): 1326-1332, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29907373

RESUMO

BACKGROUND: Anatomic surgical reduction of intra-articular fractures of the distal humerus is important to achieve the best long-term outcomes and prevent post-traumatic arthritis. In this study we compared the radiographic reduction using the trochleocapitellar index. We also correlated the trochleocapitellar index to the functional outcomes next to the comparison of the triceps brachii lifting approach and olecranon osteotomy approach, 2 common approaches for distal humeral fractures. METHODS: From January 2006 to June 2016, patients with elbow fractures were registered in 4 centers. The trochleocapitellar index, a ratio between the angle of the capitellum and the trochlea to the midline of the distal humerus on anterior-posterior radiographs, was calculated for included patients. Functional outcomes were measured using the Oxford Elbow Score and the Mayo Elbow Performance Score. Bone healing was measured using radiographic union scoring. RESULTS: There were 86 patients enrolled: 46 in the olecranon osteotomy group and 40 in the triceps lifting group. Functional outcomes and bone healing did not differ between the approaches. Functional results had a medium correlation with the trochleocapitellar index, which did not differ between the 2 approaches (olecranon osteotomy group, κ = 0.56; triceps lifting group, κ = 0.57; P = .7932). CONCLUSIONS: The trochleocapitellar index has a moderate predictive value on the functional results after 12 months after open reduction and internal fixation of intra-articular distal humeral factures. There is no difference in reduction, as measured by trochlear index and functional outcome scores, between the olecranon osteotomy approach and the triceps brachii lifting approach groups.


Assuntos
Fixação Interna de Fraturas , Fraturas do Úmero/cirurgia , Fraturas Intra-Articulares/cirurgia , Olécrano/cirurgia , Redução Aberta , Osteotomia , Adulto , Idoso , Articulação do Cotovelo/cirurgia , Feminino , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas Intra-Articulares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Músculo Esquelético , Medidas de Resultados Relatados pelo Paciente , Radiografia , Amplitude de Movimento Articular , Resultado do Tratamento
13.
Molecules ; 23(10)2018 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-30304777

RESUMO

Samples of white and red wines produced in two different wine-growing regions, coastal (Dalmatia) and continental (Hrvatsko zagorje) of Croatia, were analysed for biogenic amines content. Biogenic amines content was determined, and its concentration levels were associated with the geographical origin of the wine. Due to its high sensitivity, HPLC method with ultraviolet detector was used, including the derivatisation step with dansyl chloride. The method was applied to detect and quantify 11 biogenic amines in 48 red and white wines. It was found that both Dalmatian red and white wines are characterised by tryptamine (0.23⁻1.22 mg L-1), putrescine (0.41⁻7.5 mg L-1) and ethanolamine (2.87⁻24.32 mg L-1). White wines from the Hrvatsko zagorje region are characterised by content of isopentylamine (0.31⁻1.47 mg L-1), putrescine (0.27⁻1.49 mg L-1) and ethanolamine (3.80⁻17.96 mg L-1). In contrast to white wines from the Hrvatsko zagorje region, in the red wines, all biogenic amines except ethylamine, were found and equally presented.


Assuntos
Aminas Biogênicas/análise , Vinho/análise , Cromatografia Líquida de Alta Pressão , Croácia , Limite de Detecção , Razão Sinal-Ruído
14.
J Shoulder Elbow Surg ; 26(4): 716-722, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28089825

RESUMO

BACKGROUND: The aim of this study is to report on the midterm outcomes and complications of revision surgery of total elbow arthroplasty. METHODS: All patients who had undergone total elbow arthroplasty revision surgery between 2009 and 2014 with semiconstrained total elbow prostheses were prospectively enrolled in the study. Records were reviewed for demographic data; baseline measurements; and several follow-up assessments including the Mayo Elbow Performance Score (MEPS), visual analog scale (VAS) score for pain, Oxford Elbow Score, range of motion, satisfaction, and radiographs. RESULTS: A total of 19 revision arthroplasties were included. At a mean follow-up of 57 months, there had been 1 rerevision and 2 removals. One patient was excluded from follow-up because of confounding comorbidity. At last follow-up, MEPS values and VAS pain scores both improved (P < .01). The rate of combined good and excellent results on the MEPS was 53%. The mean VAS scores for pain at rest and with activity were 2 and 4, respectively. Fair results for the Oxford Elbow Score were reported, with a mean score of 28 points. Range of motion improved to an average flexion-extension arc of 108° (P < .01), and the pronation-supination arc improved to an average of 123° (P < .01). All elbows were stable at last follow-up (P < .01). Radiographs showed nonprogressive osteolysis around the prosthesis in 3 cases (19%) and suspicion of loosening in 1 (6%). In 11 patients postoperative complications occurred. Of 15 patients, 13 (87%) were satisfied with the result of the revision procedure. CONCLUSION: Revision of total elbow prostheses leads to satisfactory results, less pain, and better elbow function. This procedure is related to a relatively high complication rate.


Assuntos
Artroplastia de Substituição do Cotovelo , Articulação do Cotovelo/cirurgia , Reoperação , Idoso , Artroplastia de Substituição do Cotovelo/efeitos adversos , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiopatologia , Prótese de Cotovelo/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Medição da Dor , Dor Pós-Operatória/etiologia , Satisfação do Paciente , Pronação , Falha de Prótese/etiologia , Radiografia , Amplitude de Movimento Articular , Reoperação/efeitos adversos , Supinação , Fatores de Tempo , Resultado do Tratamento
15.
Arch Orthop Trauma Surg ; 137(6): 761-769, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28391430

RESUMO

BACKGROUND: Total elbow arthroplasty is a relatively uncommon type of arthroplasty, which has undergone several design changes in the past four decades. However, research on improvement requires knowledge of failure mechanisms that can be addressed. Therefore, we conducted a systematic review on modes of failure of total elbow arthroplasty. METHODS: We conducted searches on PubMed/Medline, Embase and Cochrane databases to identify studies describing modes of failure of primary total elbow arthroplasties. The results were coupled per type of total elbow arthroplasty and individual arthroplasty models. RESULTS: A total of 70 articles were included in this systematic review. 9308 individual total elbow arthroplasties were identified with 1253 revisions (13.5%). Aseptic loosening was the most prevalent reason for revision (38%), followed by deep infection (19%) and periprosthetic fractures (12%). CONCLUSION: Revision rates have been found similar to a systematic review published in 2003. The revision percentage of total elbow arthroplasty for rheumatoid arthritis is significantly higher than for trauma and post-traumatic osteoarthritis. Aseptic loosening was seen less in linked implants. Infections and periprosthetic fractures did not differ between linkage design groups. Aseptic loosening remains the most frequent cause for revision of primary total elbow arthroplasty. Therefore, more research on the occurrence, progression and risk factors of aseptic loosening should be performed and lead to higher implant survival.


Assuntos
Artrite Reumatoide/cirurgia , Artroplastia de Substituição do Cotovelo/efeitos adversos , Articulação do Cotovelo/cirurgia , Fraturas Periprotéticas/etiologia , Humanos , Falha de Prótese , Resultado do Tratamento
16.
Arch Orthop Trauma Surg ; 136(5): 617-21, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26980096

RESUMO

PURPOSE: Total elbow arthroplasty (TEA) is a definitive surgical procedure for treating rheumatoid arthritis and (posttraumatic) osteoarthritis of the elbow and is also useful in comminuted elbow fractures. Pre-operative digital templating may theoretically improve the surgical implantation of TEA, but reliability and predictive values of templating are unknown. The aim of this study was to determine the intra- and inter-observer reliability and the validity of pre-operative digital templating for TEA. MATERIALS AND METHODS: All pre-operative plain anterior-posterior and lateral calibrated elbow radiographs from patients who underwent TEA in our center from 2008 to June 2014 were reviewed. Two independent assessors templated implant sizes using digital overlays twice. Intra- and inter-observer reliability were evaluated with Cohen's kappa. Two experienced elbow surgeons reviewed post-operative radiographs for evaluation. The predictive value of templating was the percentage of the correctly templated sizes, with the optimal implant size as the reference standard. RESULTS: Twenty-one cases were included. Intra-observer reliability was substantial to almost perfect (κ = 0.61 and κ = 0.90) for humeral implants, moderate to substantial (κ = 0.54 and κ = 0.73) for ulnar implants. Inter-observer reliability was substantial (κ = 0.67) for humeral implants and moderate (κ = 0.60) for ulnar implants. The predictive value was 53 % for both implants. CONCLUSIONS: Pre-operative digital templating for TEA is a reliable method to plan implant sizes. However, the predictive value is low.


Assuntos
Artroplastia de Substituição do Cotovelo/instrumentação , Artroplastia de Substituição do Cotovelo/métodos , Cuidados Pré-Operatórios/métodos , Idoso , Idoso de 80 Anos ou mais , Artrite Reumatoide/cirurgia , Cotovelo/diagnóstico por imagem , Cotovelo/cirurgia , Feminino , Fraturas Espontâneas/cirurgia , Humanos , Úmero/cirurgia , Pessoa de Meia-Idade , Variações Dependentes do Observador , Osteoartrite/cirurgia , Radiografia , Reprodutibilidade dos Testes
17.
Nanomaterials (Basel) ; 14(8)2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38668223

RESUMO

Magnetite nanoparticles (NPs) possess properties that make them suitable for a wide range of applications. In recent years, interest in the synthesis of magnetite NPs and their surface functionalization has increased significantly, especially regarding their application in biomedicine such as for controlled and targeted drug delivery. There are several conventional methods for preparing magnetite NPs, all of which mostly utilize Fe(iii) and Fe(ii) salt precursors. In this study, we present a microwave hydrothermal synthesis for the precipitation of magnetite NPs at temperatures of 200 °C for 20 min and 260 °C for 5 min, with only iron(iii) as a precursor utilizing chamomile flower extract as a stabilizing, capping, and reducing agent. Products were characterized using FTIR, PXRD, SEM, and magnetometry. Our analysis revealed significant differences in the properties of magnetite NPs prepared with this approach, and the conventional two-precursor hydrothermal microwave method (sample MagH). FTIR and PXRD analyses confirmed coated magnetite particles. The temperature and magnetic-field dependence of magnetization indicate their superparamagnetic behavior. Importantly, the results of our study show the noticeable cytotoxicity of coated magnetite NPs-toxic to carcinoma cells but harmless to healthy cells-further emphasizing the potential of these NPs for biomedical applications.

18.
Bone Jt Open ; 4(2): 110-119, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37051858

RESUMO

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry. All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision. A total of 514 TEAs were included, of which 35 were revised. The five-year implant survival was 91%. Male sex, a higher BMI, and previous surgery to the same elbow showed a statistically significant association with revision (p < 0.036). Of the 35 revised implants, ten (29%) underwent a second revision. This study reports a five-year implant survival of TEA of 91%. Patient factors associated with revision are defined and can be used to optimize informed consent and shared decision-making. There was a high rate of secondary revisions.

19.
Shoulder Elbow ; 14(1): 96-102, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35154411

RESUMO

BACKGROUND: This study aims to use the Dutch Arthroplasty Register data to report an overview of the contemporary indications and implant designs, and report the short-term survival of radial head arthroplasty. METHODS: From the Dutch Arthroplasty Register, data on patient demographics, surgery and revision were extracted for radial head arthroplasties performed from January 2014 to December 2019. Implant survival was calculated using the Kaplan-Meier method. RESULTS: Two hundred fifty-eight arthroplasties were included with a median follow-up of 2.2 years. The most common indication was a fracture of the radial head (178, 69%). One hundred thirty-nine (68%) of the prostheses were of bipolar design, and the most commonly used implant type was the Radial Head System (Tornier; 134, 51%). Of the 258 included radial head arthroplasties, 16 were revised at a median of six months after surgery. Reason for revision was predominantly aseptic loosening (9). The overall implant survival was 95.8% after one year, 90.5% after three years and 89.5% after five years. DISCUSSION: For radial head arthroplasties, acute trauma is the most common indication and Radial Head System the most commonly used implant. The implant survival is 89.5% after five years.

20.
Strategies Trauma Limb Reconstr ; 17(2): 68-73, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35990180

RESUMO

Introduction: Injuries around the elbow pose a challenging problem for orthopaedic surgeons. The complex bony architecture of the joint should be restored and the thin soft tissue envelope needs to be handled with meticulous care. Elbow instability is a complication seen after dislocations and fractures of the elbow and remains a treatment challenge. The purpose of this study was to provide subjective and objective results following the surgical treatment of unstable elbow dislocations with an external hinged fixation technique. Methods: Forty-six consecutive patients with complex trauma of the elbow with instability after ligament reconstruction were enrolled between January 2017 and December 2019. The parameters used to quantify the subjective and objective functional results were the Mayo Elbow Score (MES, objective) and Oxford Elbow Score (OES, subjective), and clinical stability of the elbow joint. We also performed a radiological follow-up of the fractures. Results: The mean MES and OES scores were good at the 12-month follow-up. We had 38 patients with stable joints and 8 patients with minor instability. Using the stress test, we saw a significant difference in the affected joint under varus stress (6.7 ± 1.8 mm) compared to the healthy joint (5.8 ± 1.2 mm) laterally. Furthermore, medially the gap was significantly larger (5.8 ± 0.8 mm, treated elbow) than the contralateral gap under valgus stress (4.3 ± 0.8 mm) (p <0.001). Twenty-one complications occurred in 46 patients (46%): Seven patients had a clinical change of elbow axis: Three valgus (6%), four varus (9%); Superficial wound infection occurred in one case (2%) and ulnar nerve dysfunction in two (4%). The most common medium-term complication was post-traumatic osteoarthritis in eight cases (17%). Heterotopic ossification occurred in five patients (11%) and elbow stiffness in five cases (11%). Conclusion: The use of the hinged elbow external fixator in the treatment of complex elbow trauma is a valid therapeutic adjunct to ligamentous reconstruction showing encouraging results with acceptable complications. How to cite this article: Meccariello L, Caiaffa V, Mader K, et al. Treatment of Unstable Elbow Injuries with a Hinged Elbow Fixator: Subjective and Objective Results. Strategies Trauma Limb Reconstr 2022;17(2):68-73.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA