Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 181
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
CA Cancer J Clin ; 73(6): 620-652, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37329269

RESUMO

Small cell lung cancer (SCLC) is characterized by rapid growth and high metastatic capacity. It has strong epidemiologic and biologic links to tobacco carcinogens. Although the majority of SCLCs exhibit neuroendocrine features, an important subset of tumors lacks these properties. Genomic profiling of SCLC reveals genetic instability, almost universal inactivation of the tumor suppressor genes TP53 and RB1, and a high mutation burden. Because of early metastasis, only a small fraction of patients are amenable to curative-intent lung resection, and these individuals require adjuvant platinum-etoposide chemotherapy. Therefore, the vast majority of patients are currently being treated with chemoradiation with or without immunotherapy. In patients with disease confined to the chest, standard therapy includes thoracic radiotherapy and concurrent platinum-etoposide chemotherapy. Patients with metastatic (extensive-stage) disease are treated with a combination of platinum-etoposide chemotherapy plus immunotherapy with an anti-programmed death-ligand 1 monoclonal antibody. Although SCLC is initially very responsive to platinum-based chemotherapy, these responses are transient because of the development of drug resistance. In recent years, the authors have witnessed an accelerating pace of biologic insights into the disease, leading to the redefinition of the SCLC classification scheme. This emerging knowledge of SCLC molecular subtypes has the potential to define unique therapeutic vulnerabilities. Synthesizing these new discoveries with the current knowledge of SCLC biology and clinical management may lead to unprecedented advances in SCLC patient care. Here, the authors present an overview of multimodal clinical approaches in SCLC, with a special focus on illuminating how recent advancements in SCLC research could accelerate clinical development.


Assuntos
Produtos Biológicos , Neoplasias Pulmonares , Carcinoma de Pequenas Células do Pulmão , Humanos , Carcinoma de Pequenas Células do Pulmão/diagnóstico , Carcinoma de Pequenas Células do Pulmão/terapia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/terapia , Etoposídeo/uso terapêutico , Terapia Combinada , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Produtos Biológicos/uso terapêutico
2.
Thorax ; 79(8): 788-795, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38448221

RESUMO

BACKGROUND: Fibrotic interstitial lung diseases (fILDs) are a heterogeneous group of lung diseases associated with significant morbidity and mortality. Despite a large increase in the number of clinical trials in the last 10 years, current regulatory-approved management approaches are limited to two therapies that prevent the progression of fibrosis. The drug development pipeline is long and there is an urgent need to accelerate this process. This manuscript introduces the concept and design of an innovative research approach to drug development in fILD: a global Randomised Embedded Multifactorial Adaptive Platform in fILD (REMAP-ILD). METHODS: Description of the REMAP-ILD concept and design: the specific terminology, design characteristics (multifactorial, adaptive features, statistical approach), target population, interventions, outcomes, mission and values, and organisational structure. RESULTS: The target population will be adult patients with fILD, and the primary outcome will be a disease progression model incorporating forced vital capacity and mortality over 12 months. Responsive adaptive randomisation, prespecified thresholds for success and futility will be used to assess the effectiveness and safety of interventions. REMAP-ILD embraces the core values of diversity, equity, and inclusion for patients and researchers, and prioritises an open-science approach to data sharing and dissemination of results. CONCLUSION: By using an innovative and efficient adaptive multi-interventional trial platform design, we aim to accelerate and improve care for patients with fILD. Through worldwide collaboration, novel analytical methodology and pragmatic trial delivery, REMAP-ILD aims to overcome major limitations associated with conventional randomised controlled trial approaches to rapidly improve the care of people living with fILD.


Assuntos
Doenças Pulmonares Intersticiais , Humanos , Doenças Pulmonares Intersticiais/terapia , Progressão da Doença , Projetos de Pesquisa , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
Eur Radiol ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38724764

RESUMO

OBJECTIVES: To conduct an intrapatient comparison of ultra-low-dose computed tomography (ULDCT) and standard-of-care-dose CT (SDCT) of the chest in terms of the diagnostic accuracy of ULDCT and intrareader agreement in patients with post-COVID conditions. METHODS: We prospectively included 153 consecutive patients with post-COVID-19 conditions. All participants received an SDCT and an additional ULDCT scan of the chest. SDCTs were performed with standard imaging parameters and ULDCTs at a fixed tube voltage of 100 kVp (with tin filtration), 50 ref. mAs (dose modulation active), and iterative reconstruction algorithm level 5 of 5. All CT scans were separately evaluated by four radiologists for the presence of lung changes and their consistency with post-COVID lung abnormalities. Radiation dose parameters and the sensitivity, specificity, and accuracy of ULDCT were calculated. RESULTS: Of the 153 included patients (mean age 47.4 ± 15.3 years; 48.4% women), 45 (29.4%) showed post-COVID lung abnormalities. In those 45 patients, the most frequently detected CT patterns were ground-glass opacities (100.0%), reticulations (43.5%), and parenchymal bands (37.0%). The accuracy, sensitivity, and specificity of ULDCT compared to SDCT for the detection of post-COVID lung abnormalities were 92.6, 87.2, and 94.9%, respectively. The median total dose length product (DLP) of ULDCTs was less than one-tenth of the radiation dose of our SDCTs (12.6 mGy*cm [9.9; 15.5] vs. 132.1 mGy*cm [103.9; 160.2]; p < 0.001). CONCLUSION: ULDCT of the chest offers high accuracy in the detection of post-COVID lung abnormalities compared to an SDCT scan at less than one-tenth the radiation dose, corresponding to only twice the dose of a standard chest radiograph in two views. CLINICAL RELEVANCE STATEMENT: Ultra-low-dose CT of the chest may provide a favorable, radiation-saving alternative to standard-dose CT in the long-term follow-up of the large patient cohort of post-COVID-19 patients.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38626904

RESUMO

BACKGROUND: In older patients, a limited physical reserve is considered a contraindication for lung transplantation (LTx). Herein, we aimed to establish a computed tomography (CT)-based quantification of physical reserve in older patients scheduled for transplantation. METHODS: This retrospective study included patients older than 60 years who received LTx. Semiautomatic measurements of the mediastinal fat area and the dorsal muscle group area in pretransplantation CT scans were performed, and normalized data were correlated with clinical parameters. RESULTS: Patients (n = 108) were assigned into three groups (Musclehighfatlow [n = 25], Musclelowfathigh [n = 24], and other combinations [n = 59]). The Musclelowfathigh group had a significantly increased risk of wound infections (p = 0.002) and tracheostomy (p = 0.001) compared with Musclehighfatlow patients. The median length of intensive care unit stay (25 vs. 3.5 days; p = 0.002) and the median length of hospital stay (44 vs. 22.5 days; p = 0.013) post-LTx were significantly prolonged in the Musclelowfathigh group. Significantly more patients in this group had a prolonged ventilation time (11 vs. 0; p < 0.001). CONCLUSION: Body composition parameters determined in pretransplant chest CT scans in older LTx candidates might aid in identifying high-risk patients with a worse perioperative outcome after LTx.

5.
Ultraschall Med ; 45(2): 118-146, 2024 Apr.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-38237634

RESUMO

The CME review presented here is intended to explain the significance of pleural sonography to the interested reader and to provide information on its application. At the beginning of sonography in the 80 s of the 20th centuries, with the possible resolution of the devices at that time, the pleura could only be perceived as a white line. Due to the high impedance differences, the pleura can be delineated particularly well. With the increasing high-resolution devices of more than 10 MHz, even a normal pleura with a thickness of 0.2 mm can be assessed. This article explains the special features of the examination technique with knowledge of the pre-test probability and describes the indications for pleural sonography. Pleural sonography has a high value in emergency and intensive care medicine, preclinical, outpatient and inpatient, in the general practitioner as well as in the specialist practice of pneumologists. The special features in childhood (pediatrics) as well as in geriatrics are presented. The recognition of a pneumothorax even in difficult situations as well as the assessment of pleural effusion are explained. With the high-resolution technology, both the pleura itself and small subpleural consolidations can be assessed and used diagnostically. Both the direct and indirect sonographic signs and accompanying symptoms are described, and the concrete clinical significance of sonography is presented. The significance and criteria of conventional brightness-encoded B-scan, colour Doppler sonography (CDS) with or without spectral analysis of the Doppler signal (SDS) and contrast medium ultrasound (CEUS) are outlined. Elastography and ultrasound-guided interventions are also mentioned. A related further paper deals with the diseases of the lung parenchyma and another paper with the diseases of the thoracic wall, diaphragm and mediastinum.


Assuntos
Pneumopatias , Derrame Pleural , Humanos , Criança , Pleura/diagnóstico por imagem , Derrame Pleural/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tórax , Ultrassonografia/métodos
6.
Ultraschall Med ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38588693

RESUMO

PURPOSE: To evaluate the diagnostic yield of contrast-enhanced ultrasound (CEUS)-guided biopsy of retroperitoneal masses (RMs). MATERIALS AND METHODS: Between 2006 and 2023, 87 patients presented at our US center for biopsy of an RM. In all biopsies, CEUS was performed prior to the intervention. The technical success rate of biopsy, the presence of diagnostic tissue in solid tumor biopsy samples, the accuracy of the biopsy and the occurrence of post-interventional complications were evaluated. RESULTS: A US-guided biopsy could be conducted in 84/87 cases (96.6%). In 3/87 cases (3.4%), US-guided biopsy was impossible because the planned needle path was obstructed by vital structures. Of 84 lesions, 80 (95.2%) were solid lesions, and 4 (4.8%) were lesions containing fluid. In all solid tumors, 80/80 (100%), diagnostic vital tissue was successfully obtained. CEUS-guided biopsy showed a sensitivity of 93.2%, a specificity of 100%, a positive predictive value of 100%, a negative predictive value of 72.2%, and a diagnostic accuracy of 94.2% for the differentiation between malignant and benign RMs. In one of the 84 cases (1.2%), there was a complication of postinterventional abdominal pain. CONCLUSION: Percutaneous CEUS-guided biopsy is a safe procedure with a high diagnostic yield and a low complication rate.

7.
Ultraschall Med ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38484782

RESUMO

As an extension of the clinical examination and as a diagnostic and problem-solving tool, ultrasound has become an established technique for clinicians. A prerequisite for high-quality clinical ultrasound practice is adequate student ultrasound training. In light of the considerable heterogeneity of ultrasound curricula in medical studies worldwide, this review presents basic principles of modern medical student ultrasound education and advocates for the establishment of an ultrasound core curriculum embedded both horizontally and vertically in medical studies.

8.
Z Rheumatol ; 83(2): 160-168, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38240817

RESUMO

OBJECTIVE: Rheumatoid arthritis-associated interstitial lung disease (RA-ILD) is a major driver of premature mortality in patients with rheumatoid arthritis (RA). Detection of RA-ILD is crucial but requires awareness among the treating physicians. To date, however, there is no international recommendation concerning screening for ILD in RA patients. METHODS: After a systematic literature review, the modified Delphi technique in combination with the nominal group technique was used to provide a Delphi consensus statement elaborated by an expert panel of pneumonologists, rheumatologists, and a radiologist. Based on the available evidence, several clusters of questions were defined and discussed until consent was reached. RESULTS: A screening algorithm for ILD in patients with RA based on clinical signs, respiratory symptoms, and risk factors has been developed. Further, the recommendations address diagnostic tools for RA-ILD and the follow-up of RA patients qualifying for ILD screening.


Assuntos
Artrite Reumatoide , Doenças Pulmonares Intersticiais , Humanos , Artrite Reumatoide/complicações , Artrite Reumatoide/diagnóstico , Artrite Reumatoide/tratamento farmacológico , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/etiologia , Fatores de Risco
9.
Radiology ; 307(1): e222087, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36445225

RESUMO

Background Photon-counting detector (PCD) CT enables ultra-high-resolution lung imaging and may shed light on morphologic correlates of persistent symptoms after COVID-19. Purpose To compare PCD CT with energy-integrating detector (EID) CT for noninvasive assessment of post-COVID-19 lung abnormalities. Materials and Methods For this prospective study, adult participants with one or more COVID-19-related persisting symptoms (resting or exertional dyspnea, cough, fatigue) underwent same-day EID and PCD CT between April 2022 and June 2022. The 1.0-mm EID CT images and, subsequently, 1.0-, 0.4-, and 0.2-mm PCD CT images were reviewed for the presence of lung abnormalities. Subjective and objective EID and PCD CT image quality were evaluated using a five-point Likert scale (-2 to 2) and lung signal-to-noise ratios (SNRs). Results Twenty participants (mean age, 54 years ± 16 [SD]; 10 men) were included. EID CT showed post-COVID-19 lung abnormalities in 15 of 20 (75%) participants, with a median involvement of 10% of lung volume [IQR, 0%-45%] and 3.5 lobes [IQR, 0-5]. Ground-glass opacities and linear bands (10 of 20 participants [50%] for both) were the most frequent findings at EID CT. PCD CT revealed additional lung abnormalities in 10 of 20 (50%) participants, with the most common being bronchiectasis (10 of 20 [50%]). Subjective image quality was improved for 1.0-mm PCD versus 1.0-mm EID CT images (median, 1; IQR, 1-2; P < .001) and 0.4-mm versus 1.0-mm PCD CT images (median, 1; IQR, 1-1; P < .001) but not for 0.4-mm versus 0.2-mm PCD CT images (median, 0; IQR, 0-0.5; P = .26). PCD CT delivered higher lung SNR versus EID CT for 1.0-mm images (mean difference, 0.53 ± 0.96; P = .03) but lower SNR for 0.4-mm versus 1.0-mm images and 0.2-mm vs 0.4-mm images (-1.52 ± 0.68 [P < .001] and -1.15 ± 0.43 [P < .001], respectively). Conclusion Photon-counting detector CT outperformed energy-integrating detector CT in the visualization of subtle post-COVID-19 lung abnormalities and image quality. © RSNA, 2023 Supplemental material is available for this article.


Assuntos
COVID-19 , Fótons , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Imagens de Fantasmas , COVID-19/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem
10.
Eur Respir J ; 62(4)2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37802631

RESUMO

BACKGROUND: Screening for lung cancer with low radiation dose computed tomography has a strong evidence base, is being introduced in several European countries and is recommended as a new targeted cancer screening programme. The imperative now is to ensure that implementation follows an evidence-based process that will ensure clinical and cost effectiveness. This European Respiratory Society (ERS) task force was formed to provide an expert consensus for the management of incidental findings which can be adapted and followed during implementation. METHODS: A multi-European society collaborative group was convened. 23 topics were identified, primarily from an ERS statement on lung cancer screening, and a systematic review of the literature was conducted according to ERS standards. Initial review of abstracts was completed and full text was provided to members of the group for each topic. Sections were edited and the final document approved by all members and the ERS Science Council. RESULTS: Nine topics considered most important and frequent were reviewed as standalone topics (interstitial lung abnormalities, emphysema, bronchiectasis, consolidation, coronary calcification, aortic valve disease, mediastinal mass, mediastinal lymph nodes and thyroid abnormalities). Other topics considered of lower importance or infrequent were grouped into generic categories, suitable for general statements. CONCLUSIONS: This European collaborative group has produced an incidental findings statement that can be followed during lung cancer screening. It will ensure that an evidence-based approach is used for reporting and managing incidental findings, which will mean that harms are minimised and any programme is as cost-effective as possible.


Assuntos
Neoplasias Pulmonares , Guias de Prática Clínica como Assunto , Humanos , Detecção Precoce de Câncer/métodos , Etiquetas de Sequências Expressas , Achados Incidentais , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
11.
Eur Radiol ; 33(6): 4205-4213, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36604329

RESUMO

OBJECTIVES: To assess the reproducibility of radiomics features extracted from the developing lung in repeated in-vivo fetal MRI acquisitions. METHODS: In-vivo MRI (1.5 Tesla) scans of 30 fetuses, each including two axial and one coronal T2-weighted sequences of the whole lung with all other acquisition parameters kept constant, were retrospectively identified. Manual segmentation of the lungs was performed using ITK-Snap. One hundred radiomics features were extracted from fetal lung MRI data using Pyradiomics, resulting in 90 datasets. Intra-class correlation coefficients (ICC) of radiomics features were calculated between baseline and repeat axial acquisitions and between baseline axial and coronal acquisitions. RESULTS: MRI data of 30 fetuses (12 [40%] females, 18 [60%] males) at a median gestational age of 24 + 5 gestational weeks plus days (GW) (interquartile range [IQR] 3 + 3 GW, range 21 + 1 to 32 + 6 GW) were included. Median ICC of radiomics features between baseline and repeat axial MR acquisitions was 0.92 (IQR 0.13, range 0.33 to 1), with 60 features exhibiting excellent (ICC > 0.9), 27 good (> 0.75-0.9), twelve moderate (0.5-0.75), and one poor (ICC < 0.5) reproducibility. Median ICC of radiomics features between baseline axial and coronal MR acquisitions was 0.79 (IQR 0.15, range 0.2 to 1), with 20 features exhibiting excellent, 47 good, 29 moderate, and four poor reproducibility. CONCLUSION: Standardized in-vivo fetal MRI allows reproducible extraction of lung radiomics features. In the future, radiomics analysis may improve diagnostic and prognostic yield of fetal MRI in normal and pathologic lung development. KEY POINTS: • Non-invasive fetal MRI acquired using a standardized protocol allows reproducible extraction of radiomics features from the developing lung for objective tissue characterization. • Alteration of imaging plane between fetal MRI acquisitions has a negative impact on lung radiomics feature reproducibility. • Fetal MRI radiomics features reflecting the microstructure and shape of the fetal lung could complement observed-to-expected lung volume in the prediction of postnatal outcome and optimal treatment of fetuses with abnormal lung development in the future.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Masculino , Feminino , Humanos , Lactente , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Feto/diagnóstico por imagem
12.
Eur Radiol ; 33(2): 925-935, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36066734

RESUMO

OBJECTIVES: To identify and evaluate predictive lung imaging markers and their pathways of change during progression of idiopathic pulmonary fibrosis (IPF) from sequential data of an IPF cohort. To test if these imaging markers predict outcome. METHODS: We studied radiological disease progression in 76 patients with IPF, including overall 190 computed tomography (CT) examinations of the chest. An algorithm identified candidates for imaging patterns marking progression by computationally clustering visual CT features. A classification algorithm selected clusters associated with radiological disease progression by testing their value for recognizing the temporal sequence of examinations. This resulted in radiological disease progression signatures, and pathways of lung tissue change accompanying progression observed across the cohort. Finally, we tested if the dynamics of marker patterns predict outcome, and performed an external validation study on a cohort from a different center. RESULTS: Progression marker patterns were identified and exhibited high stability in a repeatability experiment with 20 random sub-cohorts of the overall cohort. The 4 top-ranked progression markers were consistently selected as most informative for progression across all random sub-cohorts. After spatial image registration, local tracking of lung pattern transitions revealed a network of tissue transition pathways from healthy to a sequence of disease tissues. The progression markers were predictive for outcome, and the model achieved comparable results on a replication cohort. CONCLUSIONS: Unsupervised learning can identify radiological disease progression markers that predict outcome. Local tracking of pattern transitions reveals pathways of radiological disease progression from healthy lung tissue through a sequence of diseased tissue types. KEY POINTS: • Unsupervised learning can identify radiological disease progression markers that predict outcome in patients with idiopathic pulmonary fibrosis. • Local tracking of pattern transitions reveals pathways of radiological disease progression from healthy lung tissue through a sequence of diseased tissue types. • The progression markers achieved comparable results on a replication cohort.


Assuntos
Fibrose Pulmonar Idiopática , Aprendizado de Máquina não Supervisionado , Humanos , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Progressão da Doença
13.
Eur Radiol ; 33(7): 5077-5086, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36729173

RESUMO

This statement from the European Society of Thoracic imaging (ESTI) explains and summarises the essentials for understanding and implementing Artificial intelligence (AI) in clinical practice in thoracic radiology departments. This document discusses the current AI scientific evidence in thoracic imaging, its potential clinical utility, implementation and costs, training requirements and validation, its' effect on the training of new radiologists, post-implementation issues, and medico-legal and ethical issues. All these issues have to be addressed and overcome, for AI to become implemented clinically in thoracic radiology. KEY POINTS: • Assessing the datasets used for training and validation of the AI system is essential. • A departmental strategy and business plan which includes continuing quality assurance of AI system and a sustainable financial plan is important for successful implementation. • Awareness of the negative effect on training of new radiologists is vital.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Radiologia/métodos , Radiologistas , Radiografia Torácica , Sociedades Médicas
14.
Eur Radiol ; 33(1): 360-367, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35779087

RESUMO

OBJECTIVES: Content-based image retrieval systems (CBIRS) are a new and potentially impactful tool for radiological reporting, but their clinical evaluation is largely missing. This study aimed at assessing the effect of CBIRS on the interpretation of chest CT scans from patients with suspected diffuse parenchymal lung disease (DPLD). MATERIALS AND METHODS: A total of 108 retrospectively included chest CT scans with 22 unique, clinically and/or histopathologically verified diagnoses were read by eight radiologists (four residents, four attending, median years reading chest CT scans 2.1± 0.7 and 12 ± 1.8, respectively). The radiologists read and provided the suspected diagnosis at a certified radiological workstation to simulate clinical routine. Half of the readings were done without CBIRS and half with the additional support of the CBIRS. The CBIRS retrieved the most likely of 19 lung-specific patterns from a large database of 6542 thin-section CT scans and provided relevant information (e.g., a list of potential differential diagnoses). RESULTS: Reading time decreased by 31.3% (p < 0.001) despite the radiologists searching for additional information more frequently when the CBIRS was available (154 [72%] vs. 95 [43%], p < 0.001). There was a trend towards higher overall diagnostic accuracy (42.2% vs 34.7%, p = 0.083) when the CBIRS was available. CONCLUSION: The use of the CBIRS had a beneficial impact on the reading time of chest CT scans in cases with DPLD. In addition, both resident and attending radiologists were more likely to consult informational resources if they had access to the CBIRS. Further studies are needed to confirm the observed trend towards increased diagnostic accuracy with the use of a CBIRS in practice. KEY POINTS: • A content-based image retrieval system for supporting the diagnostic process of reading chest CT scans can decrease reading time by 31.3% (p < 0.001). • The decrease in reading time was present despite frequent usage of the content-based image retrieval system. • Additionally, a trend towards higher diagnostic accuracy was observed when using the content-based image retrieval system (42.2% vs 34.7%, p = 0.083).


Assuntos
Doenças Pulmonares Intersticiais , Neoplasias Pulmonares , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Tórax
15.
Pediatr Blood Cancer ; 70(2): e30064, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36317710

RESUMO

INTRODUCTION: Radiographic skeletal survey (R-SS) is the standard imaging technique for the initial staging of Langerhans cell histiocytosis (LCH). Whole-body magnetic resonance imaging (WB-MRI) has been proposed as an effective, radiation-free alternative. METHODS: We prospectively assessed patients with LCH followed at three tertiary centers in Italy and Austria. Two national study protocols were independently designed, and data were then pooled to increase the power of their findings. R-SS and WB-MRI were performed at diagnosis and repeated at the follow-up to confirm the nature of the identified lesions and to study their evolution. RESULTS: Data from 67 patients were analyzed (52 from Italy and 15 from Austria). Compared to R-SS, WB-MRI identified 29 additional skeletal lesions in 14 patients (including two false-positive lesions). Two skeletal lesions were detected at R-SS and missed at WB-MRI (false negative). Per-lesion sensitivity rates were 78.6% (95% CI: 71.0-85.9) for R-SS and 98.4% (95% CI: 94.4-99.8) for WB-MRI, respectively. Based on WB-MRI findings, six patients would have been upstaged to a higher risk class than staging with R-SS. CONCLUSIONS: WB-MRI had a significantly higher detection rate for skeletal lesions compared to R-SS. Clinical and radiology expertise is required to avoid upstaging and overtreatment.


Assuntos
Doenças Ósseas , Histiocitose de Células de Langerhans , Humanos , Criança , Adulto Jovem , Imageamento por Ressonância Magnética/métodos , Imagem Corporal Total/métodos , Radiografia , Histiocitose de Células de Langerhans/diagnóstico por imagem , Estadiamento de Neoplasias , Sensibilidade e Especificidade
16.
AJR Am J Roentgenol ; 220(5): 672-680, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36475813

RESUMO

BACKGROUND. Prior work has shown improved image quality for photon-counting detector (PCD) CT of the lungs compared with energy-integrating detector CT. A paucity of the literature has compared PCD CT of the lungs using different reconstruction parameters. OBJECTIVE. The purpose of this study is to the compare the image quality of ultra-high-resolution (UHR) PCD CT image sets of the lungs that were reconstructed using different kernels and slice thicknesses. METHODS. This retrospective study included 29 patients (17 women and 12 men; median age, 56 years) who underwent noncontrast chest CT from February 15, 2022, to March 15, 2022, by use of a commercially available PCD CT scanner. All acquisitions used UHR mode (1024 × 1024 matrix). Nine image sets were reconstructed for all combinations of three sharp kernels (BI56, BI60, and BI64) and three slice thicknesses (0.2, 0.4, and 1.0 mm). Three radiologists independently reviewed reconstructions for measures of visualization of pulmonary anatomic structures and pathologies; reader assessments were pooled. Reconstructions were compared with the clinical reference reconstruction (obtained using the BI64 kernel and a 1.0-mm slice thickness [BI641.0-mm]). RESULTS. The median difference in the number of bronchial divisions identified versus the clinical reference reconstruction was higher for reconstructions with BI640.4-mm (0.5), BI600.4-mm (0.3), BI640.2-mm (0.5), and BI600.2-mm (0.2) (all p < .05). The median bronchial wall sharpness versus the clinical reference reconstruction was higher for reconstructions with BI640.4-mm (0.3) and BI640.2-mm (0.3) and was lower for BI561.0-mm (-0.7) and BI560.4-mm (-0.3) (all p < .05). Median pulmonary fissure sharpness versus the clinical reference reconstruction was higher for reconstructions with BI640.4-mm (0.3), BI600.4-mm (0.3), BI560.4-mm (0.5), BI640.2-mm (0.5), BI600.2-mm (0.5), and BI560.2-mm (0.3) (all p < .05). Median pulmonary vessel sharpness versus the clinical reference reconstruction was lower for reconstructions with BI561.0-mm (-0.3), BI600.4-mm (-0.3), BI560.4-mm (-0.7), BI640.2-mm (-0.7), BI600.2-mm (-0.7), and BI560.2-mm (-0.7). Median lung nodule conspicuity versus the clinical reference reconstruction was lower for reconstructions with BI561.0-mm (-0.3) and BI560.4-mm (-0.3) (both p < .05). Median conspicuity of all other pathologies versus the clinical reference reconstruction was lower for reconstructions with BI561.0 mm (-0.3), BI560.4-mm (-0.3), BI640.2-mm (-0.3), BI600.2-mm (-0.3), and BI560.2-mm (-0.3). Other comparisons among reconstructions were not significant (all p > .05). CONCLUSION. Only the reconstruction using BI640.4-mm yielded improved bronchial division identification and bronchial wall and pulmonary fissure sharpness without a loss in pulmonary vessel sharpness or conspicuity of nodules or other pathologies. CLINICAL IMPACT. The findings of this study may guide protocol optimization for UHR PCD CT of the lungs.


Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Brônquios
17.
Am J Respir Crit Care Med ; 206(8): 981-998, 2022 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-35763380

RESUMO

Rationale: Pulmonary hypertension (PH) is a common, severe comorbidity in interstitial lung diseases such as pulmonary fibrosis (PF), and it has limited treatment options. Excessive vascular fibrosis and inflammation are often present in PH, but the underlying mechanisms are still not well understood. Objectives: To identify a novel functional link between natural killer T (NKT) cell activation and vascular fibrosis in PF-PH. Methods: Multicolor flow cytometry, secretome, and immunohistological analyses were complemented by pharmacological NKT cell activation in vivo, in vitro, and ex vivo. Measurements and Main Results: In pulmonary vessels of patients with PF-PH, increased collagen deposition was linked to a local NKT cell deficiency and decreased IL-15 concentrations. In a mouse model of PH caused by lung fibrosis, pharmacological NKT cell activation using a synthetic α-galactosylceramide analog (KRN7000) restored local NKT cell numbers and ameliorated vascular remodeling and right ventricular systolic pressure. Supplementation with activated NKT cells reduced collagen deposition in isolated human pulmonary arterial smooth muscle cells (hPASMCs) and in ex vivo precision-cut lung slices of patients with end-stage PF-PH. Coculture with activated NKT cells induced STAT1 signaling in hPASMCs. Secretome analysis of peripheral blood mononuclear cells identified CXCL9 and CXCL10 as indicators of NKT cell activation. Pharmacologically, CXCL9, but not CXCL10, potently inhibited collagen deposition in hPASMCs via the chemokine receptor CXCR3. Conclusions: Our results indicate that the absence of NKT cells impairs the STAT1-CXCL9-CXCR3 axis in PF-PH and that restoration of this axis by NKT cell activation may unravel a novel therapeutic strategy to target vascular fibrosis in interstitial lung disease.


Assuntos
Hipertensão Pulmonar , Doenças Pulmonares Intersticiais , Fibrose Pulmonar , Animais , Humanos , Camundongos , Quimiocina CXCL9/uso terapêutico , Colágeno/metabolismo , Hipertensão Pulmonar/tratamento farmacológico , Interleucina-15/uso terapêutico , Leucócitos Mononucleares/metabolismo , Doenças Pulmonares Intersticiais/patologia , Fator de Transcrição STAT1 , Células T Matadoras Naturais
18.
Z Gastroenterol ; 61(7): 836-851, 2023 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-36170860

RESUMO

The use of handheld ultrasound devices from a technical and data protection point of view, device properties, functionality, documentation, indications, delegation of performance, applications by doctors, students and non-medical staff is examined and discussed.


Assuntos
Médicos , Humanos , Ultrassonografia
19.
Ultraschall Med ; 44(6): 582-599, 2023 Dec.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37054729

RESUMO

The CME review is intended to explain and discuss the clinical value of lung ultrasound but also to enable a pragmatically oriented approach by analyzing the clinical aspect. This includes knowledge of the pre-test probability, the acuteness of the disease, the current clinical situation, detection and/or characterization, initial diagnosis or follow up assessment and the peculiarities of exclusion diagnosis. Diseases of the pleura and lungs are described using these criteria with their direct and indirect sonographic signs and the specific clinical significance of ultrasound findings. The importance and criteria of conventional B-mode, color Doppler ultrasound with or without spectral analysis of the Doppler signal and contrast-enhanced ultrasound are discussed as well.


Assuntos
Pulmão , Pleura , Humanos , Pulmão/diagnóstico por imagem , Ultrassonografia , Pleura/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Tórax
20.
Ultraschall Med ; 44(5): 516-519, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36377189

RESUMO

The safety of ultrasound is of particular importance when examining the lungs, due to specific bioeffects occurring at the alveolar air-tissue interface. Lung is significantly more sensitive than solid tissue to mechanical stress. The causal biological effects due to the total reflection of sound waves have also not been investigated comprehensively.On the other hand, the clinical benefit of lung ultrasound is outstanding. It has gained considerable importance during the pandemic, showing comparable diagnostic value with other radiological imaging modalities.Therefore, based on currently available literature, this work aims to determine possible effects caused by ultrasound on the lung parenchyma and evaluate existing recommendations for acoustic output power limits when performing lung sonography.This work recommends a stepwise approach to obtain clinically relevant images while ensuring lung ultrasound safety. A special focus was set on the safety of new ultrasound modalities, which had not yet been introduced at the time of previous recommendations.Finally, necessary research and training steps are recommended in order to close knowledge gaps in the field of lung ultrasound safety in the future.These recommendations for practice were prepared by ECMUS, the safety committee of the EFSUMB, with participation of international experts in the field of lung sonography and ultrasound bioeffects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA