Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biol Proced Online ; 26(1): 14, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773366

RESUMO

Extracellular vesicles (EVs) are nano-sized, membranous transporters of various active biomolecules with inflicting phenotypic capabilities, that are naturally secreted by almost all cells with a promising vantage point as a potential leading drug delivery platform. The intrinsic characteristics of their low toxicity, superior structural stability, and cargo loading capacity continue to fuel a multitude of research avenues dedicated to loading EVs with therapeutic and diagnostic cargos (pharmaceutical compounds, nucleic acids, proteins, and nanomaterials) in attempts to generate superior natural nanoscale delivery systems for clinical application in therapeutics. In addition to their well-known role in intercellular communication, EVs harbor microRNAs (miRNAs), which can alter the translational potential of receiving cells and thus act as important mediators in numerous biological and pathological processes. To leverage this potential, EVs can be structurally engineered to shuttle therapeutic miRNAs to diseased recipient cells as a potential targeted 'treatment' or 'therapy'. Herein, this review focuses on the therapeutic potential of EV-coupled miRNAs; summarizing the biogenesis, contents, and function of EVs, as well as providing both a comprehensive discussion of current EV loading techniques and an update on miRNA-engineered EVs as a next-generation platform piloting benchtop studies to propel potential clinical translation on the forefront of nanomedicine.

2.
Vet Surg ; 52(2): 284-298, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36523261

RESUMO

OBJECTIVE: To develop an in vivo experimental model for bone marrow lesions (BMLs) in ovine femorotibial joints. STUDY DESIGN: Randomized, prospective experimental study. ANIMALS: Eighteen healthy, skeletally-mature Dorper cross ewes. METHODS: One medial femoral condyle was penetrated with a 1.1 mm pin, and the contralateral medial femoral condyle was treated with transcutaneous extracorporeal shockwave (ESW) at 0.39 ± 0.04 mJ/mm2 . Clinical examination, magnetic resonance imaging (MRI), computed tomography (CT), and histopathological analyses were used to detect and characterize the development and progression of BMLs in the medial femoral condyle at 4, 8, and 12 weeks post-surgery. RESULTS: Pin penetration induced a BML detected on MRI within 2 weeks and lasted at least 12 weeks. BMLs were not observed in ESW-treated condyles. Histologically, BMLs were characterized by hemorrhage and inflammatory cellular infiltrate, and progressed to more dense fibrous tissue over time. Pathological changes were not observed in the articular cartilage overlying the region of BMLs. CONCLUSIONS: Direct, focal trauma to all layers of the osteochondral unit was sufficient to create an experimentally-induced BML which persisted for at least 90 days. The protocol used for ESW in this study did not induce BMLs. CLINICAL SIGNIFICANCE: Experimental induction of BMLs is possible and mimicked naturally occurring disease states. Volumetric imaging is a sensitive method for characterization of the dynamic nature of these lesions.


Assuntos
Doenças Ósseas , Doenças das Cartilagens , Cartilagem Articular , Osteoartrite do Joelho , Doenças dos Ovinos , Ovinos , Animais , Feminino , Medula Óssea/patologia , Osteoartrite do Joelho/patologia , Osteoartrite do Joelho/veterinária , Estudos Prospectivos , Articulação do Joelho/patologia , Fêmur/diagnóstico por imagem , Fêmur/patologia , Imageamento por Ressonância Magnética/veterinária , Imageamento por Ressonância Magnética/métodos , Cartilagem Articular/patologia , Doenças Ósseas/veterinária , Doenças das Cartilagens/veterinária , Carneiro Doméstico , Modelos Teóricos
3.
Anesth Analg ; 135(4): 815-819, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35551148

RESUMO

BACKGROUND: Because intubation-mediated cervical spine and spinal cord injury are likely determined by intubation force magnitude, understanding the determinants of intubation force magnitude is clinically relevant. With direct (Macintosh) laryngoscopy, when glottic view is less favorable, anesthesiologists apply greater force. We hypothesized that, when compared with direct (Macintosh) laryngoscopy, intubation force with an optical indirect laryngoscope (Airtraq) would be less dependent on glottic visualization. METHODS: Using data obtained in a prior clinical study, we tested whether the slope of the intubation force versus glottic view relationship differed between intubations performed in 14 patients who were intubated twice, once with a Macintosh and once with an Airtraq videolaryngoscope. Slopes were compared using least-squares linear regression and robust regression. RESULTS: The slope of the intubation force (N) versus glottic view (%) relationship with the Macintosh (-0.679 [standard error {SE}, 0.147]) was significantly more negative than that of the Airtraq (-0.076 [SE, 0.246]). The least-squares regression difference in slopes was -0.603 (SE, 0.287); P = .046. The robust regression difference in slopes was -0.747 (SE, 0.187); P = .0005. Thus, when compared with the Macintosh, intubation force magnitude with Airtraq laryngoscopy was less dependent on glottic visualization. CONCLUSIONS: Previously, we reported that intubation force with the Airtraq was less in magnitude compared with the Macintosh. Our current study adds that intubation force also is less dependent on glottic view with Airtraq compared with the Macintosh.


Assuntos
Laringoscópios , Laringoscopia , Vértebras Cervicais , Desenho de Equipamento , Glote , Humanos , Intubação Intratraqueal/efeitos adversos
4.
Anesthesiology ; 135(6): 1055-1065, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34731240

RESUMO

BACKGROUND: In a closed claims study, most patients experiencing cervical spinal cord injury had stable cervical spines. This raises two questions. First, in the presence of an intact (stable) cervical spine, are there tracheal intubation conditions in which cervical intervertebral motions exceed physiologically normal maximum values? Second, with an intact spine, are there tracheal intubation conditions in which potentially injurious cervical cord strains can occur? METHODS: This study utilized a computational model of the cervical spine and cord to predict intervertebral motions (rotation, translation) and cord strains (stretch, compression). Routine (Macintosh) intubation force conditions were defined by a specific application location (mid-C3 vertebral body), magnitude (48.8 N), and direction (70 degrees). A total of 48 intubation conditions were modeled: all combinations of 4 force locations (cephalad and caudad of routine), 4 magnitudes (50 to 200% of routine), and 3 directions (50, 70, and 90 degrees). Modeled maximum intervertebral motions were compared to motions reported in previous clinical studies of the range of voluntary cervical motion. Modeled peak cord strains were compared to potential strain injury thresholds. RESULTS: Modeled maximum intervertebral motions occurred with maximum force magnitude (97.6 N) and did not differ from physiologically normal maximum motion values. Peak tensile cord strains (stretch) did not exceed the potential injury threshold (0.14) in any of the 48 force conditions. Peak compressive strains exceeded the potential injury threshold (-0.20) in 3 of 48 conditions, all with maximum force magnitude applied in a nonroutine location. CONCLUSIONS: With an intact cervical spine, even with application of twice the routine value of force magnitude, intervertebral motions during intubation did not exceed physiologically normal maximum values. However, under nonroutine high-force conditions, compressive strains exceeded potentially injurious values. In patients whose cords have less than normal tolerance to acute strain, compressive strains occurring with routine intubation forces may reach potentially injurious values.


Assuntos
Fenômenos Biomecânicos/fisiologia , Vértebras Cervicais/fisiologia , Simulação por Computador , Intubação Intratraqueal/efeitos adversos , Amplitude de Movimento Articular/fisiologia , Medula Espinal/fisiologia , Vértebras Cervicais/lesões , Humanos , Intubação Intratraqueal/métodos , Laringoscopia/efeitos adversos , Laringoscopia/métodos , Traumatismos da Medula Espinal/etiologia , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/prevenção & controle , Entorses e Distensões/etiologia , Entorses e Distensões/fisiopatologia , Entorses e Distensões/prevenção & controle
5.
Connect Tissue Res ; 62(6): 671-680, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33153311

RESUMO

Purpose/Aim: Expanded, human connective tissue cells can adopt mesenchymal stromal cell (MSC) properties that are favorable for applications in regenerative medicine. Sheep are used as a large animal model for cell therapies, although for preclinical testing it is important to establish whether ovine cells resemble humans in their tendency to adopt MSC properties. The objective of this study was to investigate whether cells from five ovine connective tissues are MSC-like in their propensity for extensive expansion and immunophenotype.Materials and Methods: Monolayer cultures were established with cells from annulus fibrosus, cartilage, meniscus, tendon, and nucleus pulposus. Bone marrow MSCs were evaluated as a control. Cultures were seeded at 500 cells/cm2, and subcultured every 5 days up to day 20. Flow cytometry was used to evaluate expression of cluster of differentiation (CD) molecules associated with MSCs (29, 44, 166). Colony formation was evaluated using time-lapse imaging of individual cells.Results: By day 20, cumulative population doublings ranged between 22 (chondrocytes) and 27 (MSCs). All cells uniformly expressed CD44 and 73. Expression of CD166 for MSCs was 98-99%, and ranged between 64 and 97% for the other cell types. Time-lapse imaging demonstrated that 58-94% of the cells colonized as indicated by 3 population doublings within 52 hours.Conclusions: Cells from ovine connective tissues resembled MSCs in their propensity for sustained, colony-forming growth and expression of CD molecules. These data supports the potential for preclinical testing of MSC-like connective tissue cells in sheep.


Assuntos
Células-Tronco Mesenquimais , Animais , Células da Medula Óssea , Diferenciação Celular , Proliferação de Células , Células Cultivadas , Condrócitos , Citometria de Fluxo , Imunofenotipagem , Medicina Regenerativa , Ovinos
6.
J Biomech Eng ; 143(12)2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34350934

RESUMO

Ventricle dysfunction is the most common cause of heart failure, which leads to high mortality and morbidity. The mechanical behavior of the ventricle is critical to its physiological function. It is known that the ventricle is anisotropic and viscoelastic. However, the understanding of ventricular viscoelasticity is much less than that of its elasticity. Moreover, the left and right ventricles (LV&RV) are different in embryologic origin, anatomy, and function, but whether they distinguish in viscoelastic properties is unclear. We hypothesized that passive viscoelasticity is different between healthy LVs and RVs. Ex vivo cyclic biaxial tensile mechanical tests (1, 0.1, 0.01 Hz) and stress relaxation (strain of 3, 6, 9, 12, 15%) were performed for ventricles from healthy adult sheep. Outflow track direction was defined as the longitudinal direction. Hysteresis stress-strain loops and stress relaxation curves were obtained to quantify the viscoelastic properties. We found that the RV had more pronounced frequency-dependent viscoelastic changes than the LV. Under the physiological frequency (1 Hz), the LV was more anisotropic in the elasticity and stiffer than the RV in both directions, whereas the RV was more anisotropic in the viscosity and more viscous than the LV in the longitudinal direction. The LV was quasi-linear viscoelastic in the longitudinal but not circumferential direction, and the RV was nonlinear viscoelastic in both directions. This study is the first to investigate passive viscoelastic differences in healthy LVs and RVs, and the findings will deepen the understanding of biomechanical mechanisms of ventricular function.


Assuntos
Ventrículos do Coração , Animais , Anisotropia , Elasticidade , Ovinos , Estresse Mecânico , Viscosidade
7.
J Biomech Eng ; 141(5)2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30835287

RESUMO

The constitutive equation used to characterize and model spinal tissues can significantly influence the conclusions from experimental and computational studies. Therefore, researchers must make critical judgments regarding the balance of computational efficiency and predictive accuracy necessary for their purposes. The objective of this study is to quantitatively compare the fitting and prediction accuracy of linear viscoelastic (LV), quasi-linear viscoelastic (QLV), and (fully) nonlinear viscoelastic (NLV) modeling of spinal-cord-pia-arachnoid-construct (SCPC), isolated cord parenchyma, and isolated pia-arachnoid-complex (PAC) mechanics in order to better inform these judgements. Experimental data collected during dynamic cyclic testing of each tissue condition were used to fit each viscoelastic formulation. These fitted models were then used to predict independent experimental data from stress-relaxation testing. Relative fitting accuracy was found not to directly reflect relative predictive accuracy, emphasizing the need for material model validation through predictions of independent data. For the SCPC and isolated cord, the NLV formulation best predicted the mechanical response to arbitrary loading conditions, but required significantly greater computational run time. The mechanical response of the PAC under arbitrary loading conditions was best predicted by the QLV formulation.

8.
Eur Spine J ; 25(1): 122-126, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26162921

RESUMO

PURPOSE: This study examined the cervical spine range of motion (ROM) resulting from whiplash-type hyperextension and hyperflexion type ligamentous injuries, and sought to improve the accuracy of specific diagnosis of these injuries. METHODS: The study was accomplished by measurement of ROM throughout axial rotation, lateral bending, and flexion and extension, using a validated finite element model of the cervical spine that was modified to simulate hyperextension and/or hyperflexion injuries. RESULTS: It was found that the kinematic difference between hyperextension and hyperflexion injuries was minimal throughout the combined flexion and extension ROM measurement that is commonly used for clinical diagnosis of cervical ligamentous injury. However, the two injuries demonstrated substantially different ROM under axial rotation and lateral bending. CONCLUSIONS: It is recommended that other bending axes beyond flexion and extension are incorporated into clinical diagnosis of cervical ligamentous injury.


Assuntos
Vértebras Cervicais/lesões , Ligamentos Longitudinais/lesões , Amplitude de Movimento Articular , Traumatismos da Coluna Vertebral/diagnóstico , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Rotação , Traumatismos em Chicotada/complicações
9.
Anesthesiology ; 123(5): 1042-58, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26288267

RESUMO

BACKGROUND: The aims of this study are to characterize (1) the cadaver intubation biomechanics, including the effect of repeated intubations, and (2) the relation between intubation force and the motion of an injured cervical segment. METHODS: Fourteen cadavers were serially intubated using force-sensing Macintosh and Airtraq laryngoscopes in random order, with simultaneous cervical spine motion recorded with lateral fluoroscopy. Motion of the C1-C2 segment was measured in the intact and injured state (type II odontoid fracture). Injured C1-C2 motion was proportionately corrected for changes in intubation forces that occurred with repeated intubations. RESULTS: Cadaver intubation biomechanics were comparable with those of patients in all parameters other than C2-C5 extension. In cadavers, intubation force (set 2/set 1 force ratio = 0.61; 95% CI, 0.46 to 0.81; P = 0.002) and Oc-C5 extension (set 2 - set 1 difference = -6.1 degrees; 95% CI, -11.4 to -0.9; P = 0.025) decreased with repeated intubations. In cadavers, C1-C2 extension did not differ (1) between intact and injured states; or (2) in the injured state, between laryngoscopes (with and without force correction). With force correction, in the injured state, C1-C2 subluxation was greater with the Airtraq (mean difference 2.8 mm; 95% CI, 0.7 to 4.9 mm; P = 0.004). CONCLUSIONS: With limitations, cadavers may be clinically relevant models of intubation biomechanics and cervical spine motion. In the setting of a type II odontoid fracture, C1-C2 motion during intubation with either the Macintosh or the Airtraq does not appear to greatly exceed physiologic values or to have a high likelihood of hyperextension or direct cord compression.


Assuntos
Intubação/métodos , Laringoscopia/métodos , Laringe/diagnóstico por imagem , Movimento (Física) , Processo Odontoide/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/fisiologia , Feminino , Humanos , Intubação/instrumentação , Laringoscópios , Laringoscopia/instrumentação , Masculino , Pessoa de Meia-Idade , Processo Odontoide/fisiologia , Radiografia
10.
Anesthesiology ; 121(2): 260-71, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24739996

RESUMO

INTRODUCTION: Laryngoscopy and endotracheal intubation in the presence of cervical spine instability may put patients at risk of cervical cord injury. Nevertheless, the biomechanics of intubation (cervical spine motion as a function of applied force) have not been characterized. This study characterized and compared the relationship between laryngoscope force and cervical spine motion using two laryngoscopes hypothesized to differ in force. METHODS: Fourteen adults undergoing elective surgery were intubated twice (Macintosh, Airtraq). During each intubation, laryngoscope force, cervical spine motion, and glottic view were recorded. Force and motion were referenced to a preintubation baseline (stage 1) and were characterized at three stages: stage 2 (laryngoscope introduction); stage 3 (best glottic view); and stage 4 (endotracheal tube in trachea). RESULTS: Maximal force and motion occurred at stage 3 and differed between the Macintosh and Airtraq: (1) force: 48.8 ± 15.8 versus 10.4 ± 2.8 N, respectively, P = 0.0001; (2) occiput-C5 extension: 29.5 ± 8.5 versus 19.1 ± 8.7 degrees, respectively, P = 0.0023. Between stages 2 and 3, the motion/force ratio differed between Macintosh and Airtraq: 0.5 ± 0.2 versus 2.0 ± 1.4 degrees/N, respectively; P = 0.0006. DISCUSSION: The relationship between laryngoscope force and cervical spine motion is: (1) nonlinear and (2) differs between laryngoscopes. Differences between laryngoscopes in motion/force relationships are likely due to: (1) laryngoscope-specific cervical extension needed for intubation, (2) laryngoscope-specific airway displacement/deformation needed for intubation, and (3) cervical spine and airway tissue viscoelastic properties. Cervical spine motion during endotracheal intubation is not directly proportional to force. Low-force laryngoscopes cannot be assumed to result in proportionally low cervical spine motion.


Assuntos
Intubação Intratraqueal/instrumentação , Laringoscópios , Laringoscopia/métodos , Coluna Vertebral/fisiologia , Adulto , Idoso , Anestesia Geral , Fenômenos Biomecânicos , Vértebras Cervicais/anatomia & histologia , Vértebras Cervicais/fisiologia , Transtornos de Deglutição/epidemiologia , Transtornos de Deglutição/etiologia , Feminino , Glote/anatomia & histologia , Cabeça/anatomia & histologia , Humanos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Laringoscopia/efeitos adversos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Pescoço/anatomia & histologia , Medição da Dor , Dor Pós-Operatória/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Coluna Vertebral/anatomia & histologia , Decúbito Dorsal , Traumatismos Dentários/epidemiologia , Traumatismos Dentários/etiologia , Distúrbios da Voz/epidemiologia , Distúrbios da Voz/etiologia
11.
J Biomech Eng ; 136(5): 051009, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24599055

RESUMO

Interlamellar shear may play an important role in the homeostasis and degeneration of the intervertebral disk. Accurately modeling the shear behavior of the interlamellar compartment would enhance the study of its mechanobiology. In this study, physical experiments were utilized to describe interlamellar shear and define a constitutive model, which was implemented into a finite element analysis. Ovine annulus fibrosus (AF) specimens from three locations within the intervertebral disk (lateral, outer anterior, and inner anterior) were subjected to in vitro mechanical shear testing. The local shear stress-stretch relationship was described for the lamellae and across the interlamellar layer of the AF. A hyperelastic constitutive model was defined for interlamellar and lamellar materials at each location tested. The constitutive models were incorporated into a finite element model of a block of AF, which modeled the interlamellar and lamellar layers using a continuum description. The global shear behavior of the AF was compared between the finite element model and physical experiments. The shear moduli at the initial and final regions of the stress-strain curve were greater within the lamellae than across the interlamellar layer. The difference between interlamellar and lamellar shear was greater at the outer anterior AF than at the inner anterior region. The finite element model was shown to accurately predict the global shear behavior or the AF. Future studies incorporating finite element analysis of the interlamellar compartment may be useful for predicting its physiological mechanical behavior to inform the study of its mechanobiology.


Assuntos
Análise de Elementos Finitos , Disco Intervertebral , Teste de Materiais , Resistência ao Cisalhamento , Animais , Fenômenos Biomecânicos , Elasticidade , Ovinos , Estresse Mecânico
12.
J Biomech Eng ; 136(2): 021020, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24170133

RESUMO

Microgravity and its inherent reduction in body-weight associated mechanical loading encountered during spaceflight have been shown to produce deleterious effects on important human physiological processes. Rodent hindlimb unloading is the most widely-used ground-based microgravity model. Unfortunately, results from these studies are difficult to translate to the human condition due to major anatomic and physiologic differences between the two species such as bone microarchitecture and healing rates. The use of translatable ovine models to investigate orthopedic-related conditions has become increasingly popular due to similarities in size and skeletal architecture of the two species. Thus, a new translational model of simulated microgravity was developed using common external fixation techniques to shield the metatarsal bone of the ovine hindlimb during normal daily activity over an 8 week period. Bone mineral density, quantified via dual-energy X-ray absorptiometry, decreased 29.0% (p < 0.001) in the treated metatarsi. Post-sacrifice biomechanical evaluation revealed reduced bending modulus (-25.8%, p < 0.05) and failure load (-27.8%, p < 0.001) following the microgravity treatment. Microcomputed tomography and histology revealed reduced bone volume (-35.9%, p < 0.01), trabecular thickness (-30.9%, p < 0.01), trabecular number (-22.5%, p < 0.05), bone formation rate (-57.7%, p < 0.01), and osteoblast number (-52.5%, p < 0.001), as well as increased osteoclast number (269.1%, p < 0.001) in the treated metatarsi of the microgravity group. No significant alterations occurred for any outcome parameter in the Sham Surgery Group. These data indicate that the external fixation technique utilized in this model was able to effectively unload the metatarsus and induce significant radiographic, biomechanical, and histomorphometric alterations that are known to be induced by spaceflight. Further, these findings demonstrate that the physiologic mechanisms driving bone remodeling in sheep and humans during prolonged periods of unloading (specifically increased osteoclast activity) are more similar than previously utilized models, allowing more comprehensive investigations of microgravity-related bone remodeling as it relates to human spaceflight.


Assuntos
Adaptação Fisiológica/fisiologia , Densidade Óssea/fisiologia , Ossos do Metatarso/citologia , Ossos do Metatarso/fisiologia , Modelos Animais , Ovinos/fisiologia , Simulação de Ausência de Peso/métodos , Animais , Contagem de Células , Força Compressiva/fisiologia , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Resistência ao Cisalhamento/fisiologia , Resistência à Tração/fisiologia
13.
Sensors (Basel) ; 14(1): 1691-704, 2014 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-24445416

RESUMO

We propose and demonstrate a wireless, passive, metamaterial-based sensor that allows for remotely monitoring submicron displacements over millimeter ranges. The sensor comprises a probe made of multiple nested split ring resonators (NSRRs) in a double-comb architecture coupled to an external antenna in its near-field. In operation, the sensor detects displacement of a structure onto which the NSRR probe is attached by telemetrically tracking the shift in its local frequency peaks. Owing to the NSRR's near-field excitation response, which is highly sensitive to the displaced comb-teeth over a wide separation, the wireless sensing system exhibits a relatively high resolution (<1 µm) and a large dynamic range (over 7 mm), along with high levels of linearity (R2 > 0.99 over 5 mm) and sensitivity (>12.7 MHz/mm in the 1-3 mm range). The sensor is also shown to be working in the linear region in a scenario where it is attached to a standard structural reinforcing bar. Because of its wireless and passive nature, together with its low cost, the proposed system enabled by the metamaterial probes holds a great promise for applications in remote structural health monitoring.


Assuntos
Técnicas Biossensoriais/métodos , Telemetria/métodos , Humanos , Tecnologia sem Fio
14.
Ann Biomed Eng ; 52(3): 671-681, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38044413

RESUMO

Nuclear factor-erythroid 2-related factor-2 (Nrf2) is a transcription factor that serves as a master regulator of anti-inflammatory agents, phase I xenobiotic, and phase II antioxidant enzymes, all of which provide a cytoprotective role during disease progression. We hypothesized that oral administration of a purported phytochemical Nrf2-activator, PB125®, would increase long bone strength in aging Hartley guinea pigs, a model prone to musculoskeletal decline. Male (N = 56) and female (N = 56) guinea pigs were randomly assigned to receive daily oral treatment with either PB125® or vehicle control. Animals were treated for a consecutive 3-months (starting at 2-months of age) or 10-months (starting at 5-months of age) and sacrificed at 5-months or 15-months of age, respectively. Outcome measures included: (1) ANY-maze™ enclosure monitoring, (2) quantitative microcomputed tomography, and (3) biomechanical testing. Treatment with PB125® for 10 months resulted in increased long bone strength as determined by ultimate bending stress in female Hartley guinea pigs. In control groups, increasing age resulted in significant effects on geometric and structural properties of long bones, as well as a trending increase in ultimate bending stress. Furthermore, both age and sex had a significant effect on the geometric properties of both cortical and trabecular bone. Collectively, this work suggests that this nutraceutical may serve as a promising target and preventive measure in managing the decline in bone mass and quality documented in aging patients. Auxiliary to this main goal, this work also capitalized upon 5 and 15-month-old male and female animals in the control group to characterize age- and sex-specific differences on long bone geometric, structural, and material properties in this animal model.


Assuntos
Fator 2 Relacionado a NF-E2 , Osteoartrite , Animais , Feminino , Cobaias , Masculino , Osso e Ossos , Fator 2 Relacionado a NF-E2/farmacologia , Fator 2 Relacionado a NF-E2/uso terapêutico , Osteoartrite/prevenção & controle , Microtomografia por Raio-X , Modelos Animais de Doenças
15.
Front Bioeng Biotechnol ; 11: 1182703, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37324443

RESUMO

Introduction: The right ventricle (RV) mechanical property is an important determinant of its function. However, compared to its elasticity, RV viscoelasticity is much less studied, and it remains unclear how pulmonary hypertension (PH) alters RV viscoelasticity. Our goal was to characterize the changes in RV free wall (RVFW) anisotropic viscoelastic properties with PH development and at varied heart rates. Methods: PH was induced in rats by monocrotaline treatment, and the RV function was quantified by echocardiography. After euthanasia, equibiaxial stress relaxation tests were performed on RVFWs from healthy and PH rats at various strain-rates and strain levels, which recapitulate physiological deformations at varied heart rates (at rest and under acute stress) and diastole phases (at early and late filling), respectively. Results and Discussion: We observed that PH increased RVFW viscoelasticity in both longitudinal (outflow tract) and circumferential directions. The tissue anisotropy was pronounced for the diseased RVs, not healthy RVs. We also examined the relative change of viscosity to elasticity by the damping capacity (ratio of dissipated energy to total energy), and we found that PH decreased RVFW damping capacity in both directions. The RV viscoelasticity was also differently altered from resting to acute stress conditions between the groups-the damping capacity was decreased only in the circumferential direction for healthy RVs, but it was reduced in both directions for diseased RVs. Lastly, we found some correlations between the damping capacity and RV function indices and there was no correlation between elasticity or viscosity and RV function. Thus, the RV damping capacity may be a better indicator of RV function than elasticity or viscosity alone. These novel findings on RV dynamic mechanical properties offer deeper insights into the role of RV biomechanics in the adaptation of RV to chronic pressure overload and acute stress.

16.
Injury ; 54(12): 111080, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37802738

RESUMO

OBJECTIVES: This study explored the efficacy of collecting temporal fracture site compliance data via an advanced direct electromagnetic coupling (DEC) system equipped with a Vivaldi-type antenna, novel calibration technique, and multi-antenna setup (termed maDEC) as an approach to monitor acute fracture healing progress in a translational large animal model. The overarching goal of this approach was to provide insights into the acute healing dynamics, offering a promising avenue for optimizing fracture management strategies. METHODS: A sample of twelve sheep, subjected to ostectomies and intramedullary nail fixations, was divided into two groups, simulating normal and impaired healing scenarios. Sequential maDEC compliance or stiffness measurements and radiographs were taken from the surgery until euthanasia at four or eight weeks and were subsequently compared with post-sacrifice biomechanical, micro-CT, and histological findings. RESULTS: The results showed that the maDEC system offered straightforward quantification of fracture site compliance via a multiantenna array. Notably, the rate of change in the maDEC-measured bending stiffness significantly varied between normal and impaired healing groups during both the 4-week (p = 0.04) and 8-week (p = 0.02) periods. In contrast, radiographically derived mRUST healing measurements displayed no significant differences between the groups (p = 0.46). Moreover, the cumulative normalized stiffness maDEC data significantly correlated with post-sacrifice mechanical strength (r2 = 0.80, p < 0.001), micro-CT measurements of bone volume fraction (r2 = 0.60, p = 0.003), and density (r2 = 0.60, p = 0.003), and histomorphometric measurements of new bone area fraction (r2 = 0.61, p = 0.003) and new bone area (r2 = 0.60, p < 0.001). CONCLUSIONS: These data indicate that the enhanced maDEC system provides a non-invasive, accurate method to monitor fracture healing during the acute healing phase, showing distinct stiffness profiles between normal and impaired healing groups and offering critical insights into the healing process's progress and efficiency.


Assuntos
Consolidação da Fratura , Fraturas Ósseas , Animais , Ovinos , Fraturas Ósseas/diagnóstico por imagem , Fixadores Internos , Radiografia , Fenômenos Eletromagnéticos , Fenômenos Biomecânicos
17.
J Biomech Eng ; 134(11): 114501, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23387789

RESUMO

Finite element (FE) models of articular joint structures do not typically implement the fully nonlinear viscoelastic behavior of the soft connective tissue components. Instead, contemporary whole joint FE models usually represent the transient soft tissue behavior with significantly simplified formulations that are computationally tractable. The resultant fidelity of these models is greatly compromised with respect to predictions under temporally varying static and dynamic loading regimes. In addition, models based upon experimentally derived nonlinear viscoelastic coefficients that do not account for the transient behavior during the loading event(s) may further reduce the model's predictive accuracy. The current study provides the derivation and validation of a novel, phenomenological nonlinear viscoelastic formulation (based on the single integral nonlinear superposition formulation) that can be directly inputted into FE algorithms. This formulation and an accompanying experimental characterization technique, which incorporates relaxation manifested during the loading period of stress relaxation experiments, is compared to a previously published characterization method and validated against an independent analytical model. The results demonstrated that the static and dynamic FE approximations are in good agreement with the analytical solution. Additionally, the predictive accuracy of these approximations was observed to be highly dependent upon the experimental characterization technique. It is expected that implementation of the novel, computationally tractable nonlinear viscoelastic formulation and associated experimental characterization technique presented in the current study will greatly improve the predictive accuracy of the individual connective tissue components for whole joint FE simulations subjected to static and dynamic loading regimes.


Assuntos
Tecido Conjuntivo , Elasticidade , Análise de Elementos Finitos , Dinâmica não Linear , Algoritmos , Animais , Ovinos , Estresse Mecânico , Viscosidade
18.
J Biomech Eng ; 134(10): 101003, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23083194

RESUMO

Using a continuum approach for modeling the constitutive mechanical behavior of the intervertebral disk's annulus fibrosus holds the potential for facilitating the correlation of morphology and biomechanics of this clinically important tissue. Implementation of a continuum representation of the disk's tissues into computational models would yield a particularly valuable tool for investigating the effects of degenerative disease. However, to date, relevant efforts in the literature towards this goal have been limited due to the lack of a computationally tractable and implementable constitutive function. In order to address this, annular specimens harvested from a total of 15 healthy and degenerated intervertebral disks were tested under planar biaxial tension. Predictions of a strain energy function, which was previously shown to be unconditionally convex, were fit to the experimental data, and the optimized coefficients were used to modify a previously validated finite element model of the L4/L5 functional spinal unit. Optimization of material coefficients based on experimental results indicated increases in the micro-level orientation dispersion of the collagen fibers and the mechanical nonlinearity of these fibers due to degeneration. On the other hand, the finite element model predicted a progressive increase in the stress generation in annulus fibrosus due to stepwise degeneration of initially the nucleus and then the entire disk. Range of motion was predicted to initially increase with the degeneration of the nucleus and then decrease with the degeneration of the annulus in all rotational loading directions, except for axial rotation. Overall, degeneration was observed to specifically impact the functional effectiveness of the collagen fiber network of the annulus, leading to changes in the biomechanical behavior at both the tissue level and the motion-segment level.


Assuntos
Degeneração do Disco Intervertebral , Vértebras Lombares , Fenômenos Mecânicos , Modelos Biológicos , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Humanos , Degeneração do Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/fisiopatologia , Vértebras Lombares/patologia , Vértebras Lombares/fisiopatologia , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Estresse Mecânico
19.
Front Bioeng Biotechnol ; 10: 1018257, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36394049

RESUMO

Following herniation of the intervertebral disc, there is a need for advanced surgical strategies to protect the diseased tissue from further herniation and to minimize further degeneration. Accordingly, a novel tissue engineered implant for annulus fibrosus (AF) repair was fabricated via three-dimensional fiber deposition and evaluated in a large animal model. Specifically, lumbar spine kinetics were assessed for eight (n = 8) cadaveric ovine lumbar spines in three pure moment loading settings (flexion-extension, lateral bending, and axial rotation) and three clinical conditions (intact, with a defect in the AF, and with the defect treated using the AF repair implant). In ex vivo testing, seven of the fifteen evaluated biomechanical measures were significantly altered by the defect. In each of these cases, the treated spine more closely approximated the intact biomechanics and four of these cases were also significantly different to the defect. The same spinal kinetics were also assessed in a preliminary in vivo study of three (n = 3) ovine lumbar spines 12 weeks post-implantation. Similar to the ex vivo results, functional efficacy of the treatment was demonstrated as compared to the defect model at 12 weeks post-implantation. These promising results motivate a future large animal study cohort which will establish statistical power of these results further elucidate the observed outcomes, and provide a platform for clinical translation of this novel AF repair patch strategy. Ultimately, the developed approach to AF repair holds the potential to maintain the long-term biomechanical function of the spine and prevent symptomatic re-herniation.

20.
Acta Biomater ; 152: 290-299, 2022 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-36030049

RESUMO

The increasing evidence of stress-strain hysteresis in large animal or human myocardium calls for extensive characterizations of the passive viscoelastic behavior of the myocardium. Several recent studies have investigated and modeled the viscoelasticity of the left ventricle while the right ventricle (RV) viscoelasticity remains poorly understood. Our goal was to characterize the biaxial viscoelastic behavior of RV free wall (RVFW) using two modeling approaches. We applied both quasi-linear viscoelastic (QLV) and nonlinear viscoelastic (NLV) theories to experimental stress relaxation data from healthy adult ovine. A three-term Prony series relaxation function combined with an Ogden strain energy density function was used in the QLV modeling, while a power-law formulation was adopted in the NLV approach. The ovine RVFW exhibited an anisotropic and strain-dependent viscoelastic behavior relative to anatomical coordinates, and the NLV model showed a higher capacity in predicting strain-dependent stress relaxation than the QLV model. From the QLV fitting, the relaxation term associated with the largest time constant played the dominant role in the overall relaxation behavior at most strains from early to late diastole, whereas the term associated with the smallest time constant was pronounced only at low strains at early diastole. From the NLV fitting, the parameters showed a nonlinear dependence on the strain. Overall, our study characterized the anisotropic, nonlinear viscoelasticity to capture the elastic and viscous resistances of the RVFW during diastole. These findings deepen our understanding of RV myocardium dynamic mechanical properties. STATEMENT OF SIGNIFICANCE: Although significant progress has been made to understand the passive elastic behavior of the right ventricle free wall (RVFW), its viscoelastic behavior remains poorly understood. In this study, we originally applied both quasi-linear viscoelastic (QLV) and nonlinear viscoelastic (NLV) models to published experimental data from healthy ovine RVFW. Our results revealed an anisotropic and strain-dependent viscoelastic behavior of the RVFW. The parameters from the NLV fitting showed nonlinear relationships with the strain, and the NLV model showed a higher capacity in predicting strain-dependent stress relaxation than the QLV model. These findings characterize the anisotropic, nonlinear viscoelasticity of RVFW to fully capture the total (elastic and viscous) resistance that is critical to diastolic function.


Assuntos
Modelos Biológicos , Dinâmica não Linear , Adulto , Animais , Anisotropia , Elasticidade , Humanos , Ovinos , Estresse Mecânico , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA