Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Hyperthermia ; 38(1): 995-1001, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34180768

RESUMO

OBJECTIVE: Percutaneous ethanol injection (PEI) and microwave ablation (MWA) are both important methods used in treating benign thyroid nodules. This study aimed to investigate the efficacy and safety of a modified PEI method combined with MWA for the treatment of symptomatic, predominantly cystic and benign thyroid nodules. MATERIALS AND METHODS: This study included 201 patients who underwent treatment in our department between April 2015 and August 2018. Predominantly cystic thyroid nodules were treated by the modified PEI procedure, which included short-term boiling ethanol ablation (STBEA) and was combined with MWA. Complications, the volume reduction ratio (VRR), symptoms and cosmetic scores were recorded at 1, 3, 6 and 12 months after treatment and every 6 months thereafter. RESULTS: No major complications were observed during or after the treatment. Ten patients (4.8%) experienced temporary voice change, which resolved within 3 months. Of 200 (97.6%) out of 205 nodules showed significant volume reduction at the final follow-up. Recurrence occurred for only 5 (2.4%) nodules. The mean thyroid nodule volume decreased from 17.40 ± 3.21 mL at baseline to 1.17 ± 0.37 mL at 12 months. The greatest VRR was observed within the first 3 months after treatment. CONCLUSIONS: The modified PEI method combined with MWA is safe and effective for the treatment of predominantly cystic benign thyroid nodules and provides a shorter operating time and lower recurrence rate than traditional treatments.


Assuntos
Nódulo da Glândula Tireoide , Etanol/uso terapêutico , Humanos , Micro-Ondas , Recidiva Local de Neoplasia , Estudos Retrospectivos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/tratamento farmacológico , Nódulo da Glândula Tireoide/cirurgia , Resultado do Tratamento
2.
Int J Hyperthermia ; 37(1): 819-825, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32633649

RESUMO

OBJECTIVE: To compare the postoperative hypocalcemia between ultrasound-guided microwave ablation (MWA) and total parathyroidectomy (TPTX) for secondary hyperparathyroidism (SHPT). METHODS: The retrospective study reviewed 286 SHPT patients (171 received MWA and 115 underwent TPTX) between March 2018 and May 2019. Propensity-score matching was used to assemble a cohort of patients with similar baseline characteristics. A total of 184 SHPT patients (92 in each group) were finally enrolled, the occurrence and prognosis of postoperative hypocalcemia were compared. And the risk factors associated with severe hypocalcemia (SH) in each group were analyzed. RESULTS: Hypocalcemia encountered in 95cases (49 in the MWA group and 46 in the TPTX group). SH occurred in 76 cases (40 in the MWA group and 36 in the TPTX group). There were no statistically significant differences in the detection time, incidence, minimum value of serum calcium and symptomatic hypocalcemia between MWA and TPTX group (all p values > 0.05). Of patients developing hypocalcemia, serum calcium did not recover to normal range in 5 cases (10.2%) in the MWA group, while 13 cases (28.3%) were still hypocalcemia at 6 months follow-up in TPTX group (p = 0.035). The time to recovery from hypocalcemia in the TPTX group (mean 30 days, range 3-180 days) was longer than the WA group (mean 14 days, range 3-126 days) (p = 0.000). High serum alkaline phosphatase (ALP) level and low serum calcium level were the main risk factors of postoperative SH. CONCLUSION: There was no difference in hypocalcemia between MWA and TPTX group. Hypocalcemia in the TPTX group might need a longer time to recover.


Assuntos
Hiperparatireoidismo Secundário , Hipocalcemia , Cálcio , Humanos , Hiperparatireoidismo Secundário/cirurgia , Hipocalcemia/etiologia , Micro-Ondas , Hormônio Paratireóideo , Paratireoidectomia , Estudos Retrospectivos , Ultrassonografia de Intervenção
3.
J Ultrasound Med ; 36(1): 189-199, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27925679

RESUMO

OBJECTIVES: This study aimed to compare the efficacy of shear wave elastography (SWE) and contrast-enhanced sonography in the differential diagnosis of superficial lymphadenopathy with abnormal imaging findings, which could not be otherwise confirmed by conventional sonography. METHODS: Forty-two enlarged superficial lymph nodes in 42 patients who met the screening criteria for this study were evaluated by both contrast-enhanced sonography and SWE. All lymph nodes underwent both methods using biopsy pathologic findings as a reference standard. RESULTS: The maximum elastic modulus, mean elastic modulus, and standard deviation of the elastic modulus were the main distinguishing features on SWE; they were significantly higher in malignant lesions than benign ones. The threshold value for the maximum elastic modulus was set at 37.9 kPa, and the sensitivity, specificity, and accuracy of differential diagnosis of superficial lymph nodes were 81.8%, 80.0%, and 81.0%, respectively. The diagnosis of benignity and malignancy by this index was statistically significant (P < .001). The lymph nodes were divided into benign and malignant groups according to different types based on the degree and range of intensity on contrast-enhanced sonography: intense or moderate homogeneous enhancement (n = 26) and heterogeneous, low homogeneous, or absent enhancement (n = 16). The sensitivity, specificity, and accuracy of contrast-enhanced sonography were 27.3%, 50.0%, and 38.1%. There was no statistically significant difference in the values between the benign and malignant groups (χ2 = 2.295; P = .130). CONCLUSIONS: Compared with contrast-enhanced sonography, SWE has better diagnostic value and efficiency in differentiation of superficial lymph nodes unexplained by conventional sonography. When conventional sonography cannot differentiate malignant superficial lymph nodes from benign ones, SWE is a useful adjunctive tool for assessment of lymph nodes.


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Linfonodos/diagnóstico por imagem , Linfadenopatia/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Diagnóstico Diferencial , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
4.
Cancer Med ; 12(19): 19537-19547, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37792639

RESUMO

PURPOSE: Pancreatic cancer is one of the most aggressive malignant tumors with poor prognosis. High-intensity focused ultrasound (HIFU) is an effective and safe treatment option for advanced pancreatic cancer, however, the survival time of patients after the treatment was different. So, the purpose of this study was to evaluate the relationship between the high-risk characteristics and prognosis of unresectable pancreatic cancer after HIFU treatment. PATIENTS AND METHODS: This prospective study included 30 patients with unresectable pancreatic cancer who received HIFU at Beijing Friendship Hospital. Data on patients' tumor size, pain scores, peripheral blood lymphocyte subsets, CA19-9 and contrast enhanced ultrasound (CEUS) features were collected to assess the relationship with overall survival (OS) after HIFU. RESULTS: The median OS from the start of HIFU treatment was 159 days, 95% confidence interval (95% CI): 108-210. The levels of pain were determined by visual analogue scale (VAS) score, and the quartile of the score decreased from 6 (2, 7) to 4 (2, 5) immediately after one session of the treatment (p = 0.001). The diagnostic model showed that high post VAS score and decreasing of peripheral CD4+ T cells were significantly correlated with poor prognosis (p < 0.05), and showed good discrimination ability (AUC = 0.848, 95% CI = 0.709-0.987). CONCLUSION: HIFU can effectively relieve pain in patients with unresectable pancreatic cancer. Post treatment VAS and change of peripheral CD4+ T cells are independent risk factors affecting the prognosis in patients with unresectable pancreatic cancer after HIFU treatment.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Neoplasias Pancreáticas , Humanos , Estudos Prospectivos , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Neoplasias Pancreáticas/patologia , Dor/etiologia , Resultado do Tratamento , Neoplasias Pancreáticas
5.
Yao Xue Xue Bao ; 47(5): 634-9, 2012 May.
Artigo em Zh | MEDLINE | ID: mdl-22812009

RESUMO

This study is to evaluate the sustained-release effect of the thermosensitive in situ gel for injection of boanmycin hydrochloride (BAM) by bioluminescence imaging in nude mice. BAM was labeled with fluorescein isothiocyanate (FITC). The FITC-labeled BAM (FITC-BAM) was purified by dialysis and Sephadex G25 gel column, and then was identified by matrix-assisted laser desorption ionization/time of flight (MALDI-TOF). The model of experimental hepatoma HepG-2 nude mice was established, and the optical imaging system was applied to evaluate the distribution of FITC-BAM in vivo. Results of MALDI-TOF proved that the major molecular ratio of BAM : FITC was 1 : 1 or 1 : 2. Bioluminescence imaging showed that the diffusion of FITC-BAM in situ gel group was significantly delayed compared with the negative control group. This study demonstrated that the thermosensitive in situ gel can effectively delay the release of boanmycin hydrochloride, and extend the retention time in vivo.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Antibióticos Antineoplásicos/farmacocinética , Bleomicina/análogos & derivados , Animais , Antibióticos Antineoplásicos/química , Bleomicina/administração & dosagem , Bleomicina/química , Bleomicina/farmacocinética , Preparações de Ação Retardada , Portadores de Fármacos/química , Feminino , Fluoresceína-5-Isotiocianato/administração & dosagem , Fluoresceína-5-Isotiocianato/química , Fluoresceína-5-Isotiocianato/farmacocinética , Géis/química , Células Hep G2 , Humanos , Injeções , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Transplante de Neoplasias , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Temperatura , Distribuição Tecidual , Viscosidade
6.
Clin Hemorheol Microcirc ; 81(1): 57-67, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35001881

RESUMO

OBJECTIVE: To examine whether contrast-enhanced ultrasound (CEUS) parameters in patients with advanced pancreatic cancer could be used to assess response to treatment with pulsed-wave high intensity focused ultrasound (PW-HIFU). METHODS: We prospectively recorded the pretreatment and posttreatment CEUS related parameters, CA19-9, pain scores of 30 patients with advanced pancreatic cancer treated with PW-HIFU treatment. Correlation of clinical parameters, tumor characteristics, and PW-HIFU treatment energy with CEUS parameters were analyzed. RESULTS: Pain score decreased after treatment (from 4.80±2.14 to 3.28±1.93, p = 0.001). CA19-9 dropped in RT decreased group, 4 weeks after one session PW-HIFU, compared with prolonged group (p = 0.013). According to the display of blood vessels in the mass by CEUS, tumors were classified by vessel grade (VG), VG1: no vessel can be seen; VG 2: vessels diameter < 5 mm; VG 3: vessels diameter > 5 mm. VGs were different between increased and decreased relative rise intensity (rRI) groups (p = 0.008). VG1 group shown a decreased rRI after treatment, while VG3 group showed the opposite trend (p = 0.006). CONCLUSIONS: CEUS can evaluating response to PW-HIFU in advanced pancreatic cancer. Quantitative analysis may help to assess the short-term efficacy of patients and help for individualized treatment.


Assuntos
Tratamento por Ondas de Choque Extracorpóreas , Ablação por Ultrassom Focalizado de Alta Intensidade , Neoplasias Pancreáticas , Antígeno CA-19-9 , Meios de Contraste/uso terapêutico , Humanos , Dor , Neoplasias Pancreáticas/tratamento farmacológico , Neoplasias Pancreáticas/terapia , Resultado do Tratamento , Neoplasias Pancreáticas
7.
Acad Radiol ; 28(3): 328-332, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32253114

RESUMO

BACKGROUND: Bilateral papillary thyroid carcinoma (PTC) requires aggressive treatment, such as total thyroidectomy (TT). If there is only an isolated PTC focus in one lobe that can be diagnosed preoperatively, and it is unknown whether there are foci in the contralateral lobe that are too small to be detected, it is difficult to know whether to perform TT or to remove only the lobe with the isolated PTC focus. Here, we investigated the prevalence of and predictive factors for occult bilateral PTC that was only diagnosed unilaterally before surgery. METHODS: This retrospective study involved 586 patients with unilateral PTC who were diagnosed preoperatively by ultrasound. They underwent TT and cervical lymph node dissection. According to the pathology, they were divided into unilateral PTC and bilateral (Bil)-PTC groups. Student's t test, chi-squared test, and multivariate analysis were performed to identify features of the malignant tumor that increased the likelihood of malignancy in the contralateral lobe. The prevalence of occult Bil-PTC was calculated. RESULTS: Bil-PTC was found in 70 of 586 (11.95%) PTC patients. Multivariate analysis showed that vascularity (odds ratio[OR]: 2.180, 95% confidence interval [CI]: 1.142-4.162, p = 0.018) and ultrasound diagnosis of lymph node metastasis (USLNM) (OR: 2.056, 95% CI: 1.056-4.004, p = 0.034) were independent predictors of occult Bil-PTC. CONCLUSION: The prevalence of occult PTC in the contralateral lobe was only 11.95%. Vascularity and USLNM were risk factors for Bil-PTC. In terms of these preoperative risk factors for PTC, TT should be cautiously performed in patients with preoperative diagnosis of PTC with isolated focus.


Assuntos
Carcinoma Papilar , Neoplasias da Glândula Tireoide , Carcinoma Papilar/diagnóstico por imagem , Carcinoma Papilar/epidemiologia , Humanos , Linfonodos , Metástase Linfática , Estudos Retrospectivos , Fatores de Risco , Câncer Papilífero da Tireoide/diagnóstico por imagem , Câncer Papilífero da Tireoide/epidemiologia , Câncer Papilífero da Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/epidemiologia , Neoplasias da Glândula Tireoide/cirurgia
8.
World J Clin Cases ; 9(16): 3943-3950, 2021 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-34141751

RESUMO

BACKGROUND: Transplant renal artery stenosis is a relatively frequent vascular complication after transplantation. However, extra-renal pseudo-aneurysms (EPSAs) are rare after transplantation; they can be life-threatening and usually need open surgical repair. We discuss the diagnosis and spontaneous healing of an asymptomatic renal allograft EPSA caused by renal artery anastomotic stenosis, which was diagnosed in a timely manner and managed by conservative treatments. CASE SUMMARY: We present a 37-year-old male patient diagnosed with a renal allograft EPSA caused by renal artery anastomotic stenosis due to multiple atherosclerotic plaques with ultrasonographic examination 6 mo post transplantation. The stenosis rate of 90% and the EPSA were verified by computed tomography angiography. The diagnosis was further confirmed with digital subtraction angiography. Percutaneous transluminal angiography was conducted, and a metallic stent was successfully implanted at the stenosed site of the main renal artery trunk. No further intervention for the EPSA was undertaken due to the difficulty of stenting and the risk of bleeding; regular ultrasonographic follow-ups were recommended. The stenosis was significantly relieved immediately after stent implantation and the EPSA was healed spontaneously by completely filling with hypo-echoic thrombosis 8 mo after stenting. CONCLUSION: Ultrasonography combined with a high-frequency linear probe can detect vascular complications post renal transplantation at an early stage and improve prognosis.

9.
Front Oncol ; 11: 756878, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35087745

RESUMO

OBJECTIVES: Differentiation of benign and malignant changes in lymph nodes is extremely important. We aimed to identify the ultrasound and clinical diagnostic criteria permitting this differentiation. METHODS: Clinical and ultrasound data were collected at Beijing Friendship Hospital from May 2019 to November 2020. Univariate and multivariate analysis were performed using statistical methods, and a mathematical model was established to evaluate benign and malignant lymph nodes. RESULTS: A total of 1343 LNs (person) with US-guided core needle or fine needle biopsy (CNB or FNB) were evaluated in the analysis. Variables with a high predictive power were sex (odds ratio, OR: 3.360, p<0.001), short diameter (OR: 4.660, p<0.001), short/long diameter (S/L) ratio (OR: 1.515, P=0.007), border (OR: 1.626, p=0.002), cortex echogenicity (OR: 2.089, P<0.001), fusion (OR: 2.313, p=0.002), vascularity (peripheral vascularity, OR: 3.424, p<0.001; mixed vascularity, OR: 4.127, p<0.001), and medical history (fever/local pain, OR: 0.316, p<0.001; tumor history in the drainage area, OR: 4.595, p<0.001; both, OR: 5.554, p<0.001). The cut-off score on receiver operating characteristic (ROC) curve analysis using these eight variables was 2.5. The largest area under the ROC curve (Az) value was 82.3% (95% confidence interval (CI), 0.805-0.851), and the sensitivity (79.4%), specificity (72.3%), and accuracy (74.8%) were higher than those for nearly all the single indices. CONCLUSION: The model of combination of ultrasound and clinical symptoms can preliminarily evaluate the benign and malignant of lymph nodes.

10.
Ultrasound Med Biol ; 46(3): 582-588, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31917043

RESUMO

We aimed to evaluate whether subcapsular injection of ultrasonic contrast agent (UCA) can distinguish between benign and malignant lymph node (LN) lesions exhibiting homogeneous enhancement in intravenous contrast-enhanced ultrasound (CEUS) images. From November 2012 to July 2015, 32 patients with superficial lymphadenopathy exhibiting homogeneous enhancement after intravenous CEUS were enrolled. A small amount of UCA was injected into LNs using a subcapsular approach, and perfusion characteristics were recorded. Using the pathology identified via core needle biopsy as the gold standard, we calculated the sensitivity, specificity and accuracy of the technique in terms of distinguishing between benign and malignant LN lesions. Pathology revealed 23 cases of true benign and 9 cases of true malignant LN lesions; the former included 2 cases of tuberculosis and 21 cases of reactive hyperplasia, and the latter included 7 lymphomas and 2 metastases. Subcapsular CEUS diagnosed 24 benign and 8 malignant LN lesions. Most lymphomas (6 of 7, 85.7%) exhibited heterogeneous perfusion, with lymphatic tract distortion in the absence of interruption. Reactive hyperplasia LNs manifested as diffuse homogeneous or brush-like perfusion from the subcapsular region to the center, without lymphatic tract distortion. Metastatic LNs had lymphatic tract interruptions. The sensitivity, specificity, consistency and positive and negative predictive values were 77.8%, 95.6%, 90.6%, 87.5% and 91.7%, respectively. For LNs exhibiting uniform enhancement in intravenous CEUS imaging, subcapsular CEUS may help to distinguish between benign and malignant lesions. In particular, lymphatic distortion without interruption may specifically indicate a lymphoma.


Assuntos
Meios de Contraste/administração & dosagem , Linfonodos/diagnóstico por imagem , Linfadenopatia/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Injeções Intralesionais , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Ultrassonografia/métodos , Adulto Jovem
11.
World J Clin Cases ; 7(13): 1677-1685, 2019 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-31367627

RESUMO

BACKGROUND: Primary renal synovial sarcoma (PRSS) is an extremely rare tumor with a poor prognosis. Its imaging and immunohistochemical characteristics may overlap with other renal tumors, which renders its early diagnosis in a dilemma. The diagnosis of primary renal synovial sarcoma requires histopathology and the confirmation of SYT-SSX gene fusion using molecular techniques. Cases of primary renal synovial sarcoma have been previously reported in the literature. However, to our knowledge, primary renal allograft synovial sarcoma was never described. CASE SUMMARY: A 43-year-old male patient who underwent kidney transplantation 9 months ago came to our hospital for regular follow-up. Traditional ultrasonography revealed multiple hypo-echo neoplasms in the renal allograft. Contrast-enhanced computed tomography (CECT) showed slightly hyper-density masses with slow homogeneous enhancement. Ultrasound-guided biopsy was conducted for accurate pathological diagnosis. The neoplasms were diagnosed as synovial sarcoma by pathological, immunohistochemical, and genetic analyses. Positron emission tomography/CT showed no evidence of metastasis. At approximately one week post biopsy, contrast-enhanced ultrasound was conducted to eliminate active hemorrhage. One month later, CECT showed that the biggest neoplasm grew from 3.3 cm to 5.7 cm in diameter. Parametric imaging was conducted with SonoLiver CAP to conduct further quantitative analysis, which showed that the enhancement pattern was heterogeneous hyper-vascular enhancement. Radical surgical resection of the whole renal allograft and ureter was conducted without additional adjuvant chemotherapy or external radiotherapy. Anlotinib was chosen for targeted therapy with a good response. CONCLUSION: We propose multimodality imaging for accurate diagnosis of renal allograft synovial sarcoma especially when it is formed by spindle-shaped cells.

12.
World J Clin Cases ; 7(10): 1122-1132, 2019 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-31183343

RESUMO

BACKGROUND: Staging diagnosis of liver fibrosis is a prerequisite for timely diagnosis and therapy in patients with chronic hepatitis B. In recent years, ultrasound elastography has become an important method for clinical noninvasive assessment of liver fibrosis stage, but its diagnostic value for early liver fibrosis still needs to be further improved. In this study, the texture analysis was carried out on the basis of two dimensional shear wave elastography (2D-SWE), and the feasibility of 2D-SWE plus texture analysis in the diagnosis of early liver fibrosis was discussed. AIM: To assess the diagnostic value of 2D-SWE combined with textural analysis in liver fibrosis staging. METHODS: This study recruited 46 patients with chronic hepatitis B. Patients underwent 2D-SWE and texture analysis; Young's modulus values and textural patterns were obtained, respectively. Textural pattern was analyzed with regard to contrast, correlation, angular second moment (ASM), and homogeneity. Pathological results of biopsy specimens were the gold standard; comparison and assessment of the diagnosis efficiency were conducted for 2D-SWE, texture analysis and their combination. RESULTS: 2D-SWE displayed diagnosis efficiency in early fibrosis, significant fibrosis, severe fibrosis, and early cirrhosis (AUC > 0.7, P < 0.05) with respective AUC values of 0.823 (0.678-0.921), 0.808 (0.662-0.911), 0.920 (0.798-0.980), and 0.855 (0.716-0.943). Contrast and homogeneity displayed independent diagnosis efficiency in liver fibrosis stage (AUC > 0.7, P < 0.05), whereas correlation and ASM showed limited values. AUC of contrast and homogeneity were respectively 0.906 (0.779-0.973), 0.835 (0.693-0.930), 0.807 (0.660-0.910) and 0.925 (0.805-0.983), 0.789 (0.639-0.897), 0.736 (0.582-0.858), 0.705 (0.549-0.883) and 0.798 (0.650-0.904) in four liver fibrosis stages, which exhibited equivalence to 2D-SWE in diagnostic efficiency (P > 0.05). Combined diagnosis (PRE) displayed diagnostic efficiency (AUC > 0.7, P < 0.01) for all fibrosis stages with respective AUC of 0.952 (0.841-0.994), 0.896 (0.766-0.967), 0.978 (0.881-0.999), 0.947 (0.835-0.992). The combined diagnosis showed higher diagnosis efficiency over 2D-SWE in early liver fibrosis (P < 0.05), whereas no significant differences were observed in other comparisons (P > 0.05). CONCLUSION: Texture analysis was capable of diagnosing liver fibrosis stage, combined diagnosis had obvious advantages in early liver fibrosis, liver fibrosis stage might be related to the hepatic tissue hardness distribution.

13.
J Biomech ; 76: 235-240, 2018 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-29853319

RESUMO

It has been reported that ex vivo viscoelastic properties of liver tissues usually differ from those measured in in vivo state due to the reasons such as the effects of perfusion, temperature, and native pre-stress. Therefore, the development of an appropriate ex vivo protocol, which enables the measurement of liver mechanical properties close to those in vivo, is of great importance and has been pursued over the years. In this paper, we propose a simple protocol by ligating the liver when performing ex vivo indentation relaxation tests. Our results show that the viscoelastic kernel function, which measures the intrinsic time-dependent mechanical behavior of a viscoelastic material, determined with the present protocol can describe the in vivo viscoelasticity of liver tissues well in comparison with the ex vivo result measured on a liver without ligation and that obtained in vitro. The performance of the protocol reported here is similar to the ex vivo perfusion system developed by Kerdok et al. (2006). However, the present experimental set-up is much easier to realize.


Assuntos
Fígado/fisiologia , Algoritmos , Animais , Elasticidade , Ligadura , Masculino , Perfusão , Ratos Sprague-Dawley , Estresse Mecânico , Viscosidade
14.
J Mech Behav Biomed Mater ; 83: 120-125, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29702328

RESUMO

Determining the mechanical properties of brain tissues is essential in the field of brain biomechanics. In this paper, we use ultrasound-based shear wave elastography to measure both in vivo and ex vivo elastic properties of brain tissues. Our results demonstrate that the shear modulus from in vivo measurements is about 47% higher than that given by the ex vivo measurements (p value = 0.0063). The change in ex vivo elastic properties within 60-min post-mortem is negligible. The results also show that within 60-min post-mortem and in a temperature range of 37-23 °C, the elastic properties of brain tissues approximately linearly depend on the temperature in both cooling and re-heating processes.


Assuntos
Encéfalo/diagnóstico por imagem , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade , Animais , Teste de Materiais , Coelhos , Temperatura
15.
Zhonghua Gan Zang Bing Za Zhi ; 15(1): 47-9, 2007 Jan.
Artigo em Zh | MEDLINE | ID: mdl-17244460

RESUMO

OBJECTIVE: To compare the complication rates induced by three liver biopsy methods. METHODS: One thousand five hundred fifty-seven liver biopsies were performed from 1995 to 2006 by the senior author of the present article. The patients were grouped into a non-ultrasound-guided biopsy group (783 cases), a partially ultrasound-guided group (485 cases) and an ultrasound-guided group (289 cases). The observed complications such as death, hemorrhage, pneumothorax, pain, choleperitoneum and vasovagal syncope were compared between these three groups. RESULTS: Only 1 patient in the non-ultrasound-guided group died. Seven patients (45%), 4 in non-ultrasound-guided group, 2 in partially ultrasound-guided group and 1 in ultrasound-guided group, had hemorrhage complications. The hemorrhage complication rates between partially ultrasound-guided group and ultrasound-guided group had no significant differences and both were lower than those of the non-ultrasound-guided group. Thirty-five patients, 23 in non-ultrasound-guided group and 12 in partially ultrasound-guided group, suffered from pneumothorax; but the rates between the two groups were not significantly different. Forty-eight patients (45%), 28 in non-ultrasound-guided group, 17 in partially ultrasound-guided group and 3 in ultrasound-guided group, had severe pain and the rate in the ultrasound-guided group was significantly lower than those of the other two groups. CONCLUSION: Liver biopsy performed under ultrasound guidance is the safest and most reliable way to do the procedure. It should be recommended in clinical practices.


Assuntos
Biópsia/efeitos adversos , Biópsia/métodos , Fígado/patologia , Adolescente , Adulto , Idoso , Criança , Humanos , Fígado/diagnóstico por imagem , Pessoa de Meia-Idade , Ultrassonografia , Adulto Jovem
16.
Zhonghua Gan Zang Bing Za Zhi ; 15(4): 249-53, 2007 Apr.
Artigo em Zh | MEDLINE | ID: mdl-17456309

RESUMO

OBJECTIVE: To discuss the diagnostic value of an ultrasonic assessing system for detecting the severity of hepatic fibrosis in patients with chronic hepatitis B (CHB). METHODS: Ultrasonographic variables were analyzed in 110 CHB patients. An ultrasonic semi-quantitative scoring system using seven ultrasonic morphologic parameters, a Fisher discriminating function and three quantitative ultrasonic parameters was developed. The performance of these methods was also studied and compared. RESULTS: The areas under the curve of the scoring system for different liver fibrosis stages were >or= S2: 0.946, >or= S3: 0.914, and S4: 0.915. The total score was well correlated with the histological stage of fibrosis (r=0.824, P < 0.001). There was a significant difference between the stages of fibrosis. The accuracy of the Fisher discriminating function for identifying three study endpoints was 76.5%, 78.2% and 67.3%. Combining the ultrasonic scoring system and the discriminating function, the specificity was 85%-90% and the accuracy was 77%-84%. CONCLUSION: Our ultrasonic semi-quantitative scoring system is a noninvasive method for quantitating liver fibrosis. If it is used together with a discriminating function, the accuracy of diagnosing liver fibrosis can be significantly increased.


Assuntos
Hepatite B Crônica/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Adolescente , Adulto , Idoso , Feminino , Humanos , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Adulto Jovem
17.
Exp Biol Med (Maywood) ; 242(15): 1515-1523, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28847173

RESUMO

The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up ( P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.


Assuntos
Ablação por Cateter , Micro-Ondas , Nódulo da Glândula Tireoide/radioterapia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
18.
Ultrasound Med Biol ; 43(10): 2343-2351, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28705556

RESUMO

The goal of the work described here was to explore the cause of spleen stiffness (SS) in hepatic fibrogenesis and evaluate the value of SS in liver fibrosis (LF) staging. LF was induced with carbon tetrachloride (CCl4) in rats (n = 40). Supersonic shear wave imaging and contrast-enhanced ultrasound were performed to determine liver stiffness (LS), SS and splenic hemodynamics. SS, LS and free portal pressure exhibited moderate correlations with fibrosis stage (r = 0.744-0.835, p < 0.001). Time-intensity curves of contrast-enhanced ultrasound for the spleen were presented as decreasing peak intensity and slope of decrease, and increasing time to peak. Splenic sinus dilation and congestion were observed on histopathologic analysis. The area under the receiver operating characteristic curve of SS was higher than that of LS for differentiating LF stages 0-2 from stages 3-4 (Z = 2.293, p = 0.02). SS is a reliable diagnostic marker for the assessment of LF in the CCl4 model, especially for severe fibrosis. Elevated portal pressure is the cause of increasing SS.


Assuntos
Meios de Contraste , Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/métodos , Cirrose Hepática/patologia , Baço/diagnóstico por imagem , Baço/patologia , Animais , Modelos Animais de Doenças , Fosfolipídeos , Pressão na Veia Porta/fisiologia , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Baço/fisiopatologia , Hexafluoreto de Enxofre
19.
World J Gastroenterol ; 23(12): 2141-2148, 2017 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-28405141

RESUMO

AIM: To assess the insulating effect of a poloxamer 407 (P407)-based gel during microwave ablation of liver adjacent to the diaphragm. METHODS: We prepared serial dilutions of P407, and 22.5% (w/w) concentration was identified as suitable for ablation procedures. Subsequently, microwave ablations were performed on the livers of 24 rabbits (gel, saline, control groups, n = 8 in each). The P407 solution and 0.9% normal saline were injected into the potential space between the diaphragm and liver in experimental groups. No barriers were applied to the controls. After microwave ablations, the frequency, size and degree of thermal injury were compared histologically among the three groups. Subsequently, another 8 rabbits were injected with the P407 solution and microwave ablation was performed. The levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), blood urea nitrogen (BUN) and creatinine (Cr) in serum were tested at 1 d before microwave ablation and 3 and 7 d after operation. RESULTS: In vivo ablation thermal injury to the adjacent diaphragm was evaluated in the control, saline and 22.5% P407 gel groups (P = 0.001-0.040). However, there was no significant difference in the volume of ablation zone among the three groups (P > 0.05). Moreover, there were no statistical differences among the preoperative and postoperative gel groups according to the levels of ALT, AST, BUN and Cr in serum (all P > 0.05). CONCLUSION: Twenty-two point five percent P407 gel could be a more effective choice during microwave ablation of hepatic tumors adjacent to the diaphragm. Further studies for clinical translation are warranted.


Assuntos
Carcinoma Hepatocelular/terapia , Ablação por Cateter/métodos , Diafragma/lesões , Neoplasias Hepáticas/terapia , Micro-Ondas , Poloxâmero/química , Lesões por Radiação/prevenção & controle , Alanina Transaminase/sangue , Animais , Aspartato Aminotransferases/sangue , Nitrogênio da Ureia Sanguínea , Creatinina/sangue , Feminino , Géis , Temperatura Alta , Humanos , Fígado/efeitos da radiação , Masculino , Coelhos , Reologia , Temperatura
20.
Zhonghua Gan Zang Bing Za Zhi ; 14(3): 169-73, 2006 Mar.
Artigo em Zh | MEDLINE | ID: mdl-16556408

RESUMO

OBJECTIVE: To develop a diagnostic model comprising clinical and serum markers for assessing HBV-related liver fibrosis. METHODS: 270 chronic hepatitis B patients were randomly allocated to either an estimation group (195 cases) or a validation group (75 cases). Liver biopsies were done and staging of fibrosis was assessed. Twenty-six common clinical and serum markers were analyzed initially in the estimation group to derive a predictive model to discriminate the stages of fibrosis. The model created was then assessed with ROC analysis. It was also applied to the validation group to test its accuracy. RESULTS: Among 13 variables associated with liver fibrosis selected by univariate analysis, age, gamma glutamyltranspeptidase (GGT), hyaluronic acid (HA), and platelet count (PLT) were identified by multivariate logistic regression analysis as independent factors of fibrosis. A fibrosis index constructed from the above four markers was established. In ROC analysis, the AUC was 0.889 for the estimation group and 0.850 for the validation group for discriminating > or =S3 from < or=S2. Using the optimal cutoff score 3.0, the sensitivity of the index was 90.2%, the specificity 76.1%, and the accuracy was 82%. There was a positive linear relationship between the index scores and the fibrosis stages (r = 0.731, P<0.001). The AUC for identifying > or=S2 was 0.873 with sensitivity/specificity of 79%/82%, cutoff score 2.2; The AUC for identifying S4 was 0.872 with sensitivity/specificity of 83%/75%, cutoff score 5.4. There were no significant differences in diagnostic efficacy in the model between the estimation and the validation group (P>0.05). CONCLUSION: A model for assessment of liver fibrosis was established with easily accessible markers. It appears to be sensitive, accurate and reproducible, suggesting it could be used to assist or replace liver biopsy to detect dynamic changes of HBV-related liver fibrosis.


Assuntos
Hepatite B Crônica/diagnóstico , Cirrose Hepática/diagnóstico , Adolescente , Adulto , Idoso , Feminino , Previsões , Hepatite B Crônica/complicações , Humanos , Cirrose Hepática/etiologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA