Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Rev Cardiovasc Med ; 25(1): 3, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39077657

RESUMO

Background: Transcatheter aortic valve replacement (TAVR) has become the dominant treatment for aortic valve disease. While TAVR safety has improved over time, concern remains over the occurrence of cerebrovascular accidents (CVA) secondary to device placement, which is associated with increased morbidity and mortality. The Sentinel Cerebral Protection System (CPS) was developed to reduce the risk of embolic strokes associated with debris produced during TAVR. Studies evaluating Sentinel CPS efficacy have produced conflicting results, and there is little understanding of which patients are selected for device placement in "real-world" settings. With no existing guidelines on device use, the purpose of this study was to describe and compare the characteristics of patients who receive CPS with those who do not in a "real-world" setting of consecutive TAVR patients and evaluate its impact on postoperative complications, namely stroke. Methods: This was a single-center, retrospective study of all patients undergoing TAVR between July 1, 2019, and December 31, 2020. Patient demographics, baseline, and perioperative characteristics were collected prospectively using the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapy (TVT) Registry and our institution's TAVR database for analysis. Postoperative outcomes were assessed using primary endpoints of in-hospital/30-day stroke and the composite of death, stroke, and bleeding/vascular events at one-year. To adjust for baseline differences, a propensity score was developed including all factors that were different between groups, and Multivariate Cox Regression analysis was used to control for these differences. Patient follow-up was 97% complete at 12 months with 100% echocardiographic follow-up. Results: A total of 242 consecutive patients (57.9% male) were analyzed, with a mean age of 79.9 ± 9 years. Of these patients, 134 (55.4%) received the Sentinel CPS and 108 (44.6%) did not. Sentinel CPS patients were more likely to be male, not on dialysis, without prior CVA or pacemaker, had less severe chronic lung disease, and were lower operative risk compared to concurrent non-CPS patients. CPS patients were also found to have higher hemoglobin and albumin levels, lower creatinine, and were less likely to be on immunosuppressant therapy. The incidence of in-hospital/30-day stroke after TAVR did not differ between CPS and non-CPS patients (0.0% vs. 1.9%; p = 0.198). Unadjusted analyses at one-year showed a lower occurrence of the composite endpoint in CPS patients compared non-CPS patients (8.3% vs. 17.0%; p = 0.034). After adjustment, the hazard ratio (Adj HR) for the CPS group was no longer significantly associated with a lower composite endpoint (Adj HR = 0.609, 95% CI 0.244-1.523; p = 0.289). Both unadjusted (p = 0.233) and adjusted (p = 0.132) analyses showed no difference in the incidence of stroke at one-year. Conclusions: Our study demonstrates that in a "real-world" setting, the Sentinel CPS device is more likely to be used in healthier and less complex patients. In analyses adjusted for illness severity and patient complexity, CPS use did not have a significant effect on the incidence of in-hospital/30-day stroke or the composite endpoint of death, stroke, and bleeding/vascular events at one-year.

2.
Catheter Cardiovasc Interv ; 96(1): E53-E58, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31631521

RESUMO

OBJECTIVE: The primary objective was to demonstrate diagnostic equivalence between RFR and iFR in clinical practice. BACKGROUND: The instantaneous wave-free ratio (iFR), a nonhyperemic pressure ratio (NHPR), has been shown to be noninferior to fractional flow reserve (FFR) in determining coronary artery stenosis severity in intermediate lesions. However, iFR has a number of inherent limitations, including sensitive landmarking of the pressure waveform and the assumption that maximal flow and minimal microcirculatory resistance occur during a fixed period within diastole. The resting full-cycle ratio (RFR) is a novel NHPR which evaluates the entire cardiac cycle independent of the ECG, landmark identification, and timing within the cardiac cycle. METHODS: RE-VALIDATE RFR was designed to determine the diagnostic utility of RFR for the physiological assessment of coronary artery disease in clinical practice compared to iFR. RFR was also tested for equivalence (1% margin), diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), areas under the receiver operated characteristic curve (AUC), and correlations compared to calculated iFR (iFRcalc ). RESULTS: From two centers, 501 blinded rest- and hyperemic pressure recordings from 431 patients were suitable for analysis according to a core laboratory. The mean FFR, RFR, and iFRcalc were 0.80 ± 0.09, 0.90 ± 0.08, and 0.90 ± 0.08, respectively. Based on a binary cut-off approach (RFR/iFR ≤0.89), RFR demonstrated equivalence with iFRcalc (95% confidence interval: 0.025-0.019) with overall diagnostic accuracy 97.8%, sensitivity 97.8%, specificity 97.8%, PPV 96.2%, NPV 98.7%, and AUC 0.96 (0.94-0.97, p < .001). RFR had a mean bias 0.003 (95% limits of agreement: 0.019, -0.025). CONCLUSIONS: RFR was equivalent to iFR in clinical practice. RFR is an alternative NHPR, avoiding the need for hyperemic agents, thus potentially reducing side effects, procedural time and cost compared to FFR.


Assuntos
Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Reserva Fracionada de Fluxo Miocárdico , Hiperemia/fisiopatologia , Idoso , Estenose Coronária/fisiopatologia , Feminino , Georgia , Humanos , Masculino , Pessoa de Meia-Idade , Cidade de Nova Iorque , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
3.
Am Heart J ; 213: 105-111, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31132582

RESUMO

BACKGROUND: Drug-eluting stents (DESs) have improved clinical outcomes of patients undergoing percutaneous coronary intervention (PCI). Nevertheless, adverse events related to previously treated lesion still occur. We sought to evaluate the incidence and predictors of target lesion failure (TLF) in patients undergoing contemporary DES implantation. METHODS: Patient-level data from 6 prospective, randomized trials were pooled, and DES treatment outcomes were analyzed at up to 5 years. Primary outcome was TLF (cardiac death, target lesion revascularization, or target vessel myocardial infarction). Cox proportional-hazards model was used to identify predictors of TLF. RESULTS: Overall, 10,072 patients were included in the analysis. TLF rate was 1.7%, 4.3%, and 11.9% at 30 days, 1 year, and 5 years, respectively. The only independent predictor of TLF at 30 days was stent length (hazard ratio [HR] 1.017, 95% CI 1.011-1.024, P < .0001). Moderate/severe calcification, stent length and post procedural diameter sthenosis were predictors between 30 days to 1 year but not at 1 to 5 years. Reference vessel diameter was the only lesion-related predictor at 5 years (P = .003). Clinical predictors of TLF between 30 days and 1 year were diabetes and hypertension (P < .01 for both), and between 1 and 5 years, diabetes (HR 1.40, 95% CI 1.13-1.73, P = .002), prior coronary artery bypass grafting (HR 2.52, 95% CI 1.92-3.30, P < .0001), and prior PCI (HR 1.29, 95% CI 1.02-1.64, P = .04) predicted TLF. CONCLUSIONS: Predictors of TLF vary in the early, late, and very late postprocedural periods. Reference vessel diameter was the only lesion-related predictor of long-term TLF; clinical predictors were diabetes, prior coronary artery bypass grafting, and prior PCI.


Assuntos
Reestenose Coronária/terapia , Stents Farmacológicos/estatística & dados numéricos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/estatística & dados numéricos , Falha de Prótese , Antineoplásicos/uso terapêutico , Everolimo/uso terapêutico , Feminino , Cardiopatias/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/uso terapêutico , Intervenção Coronária Percutânea/métodos , Modelos de Riscos Proporcionais , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Fatores de Tempo , Falha de Tratamento
4.
Catheter Cardiovasc Interv ; 93(7): 1255-1261, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30489011

RESUMO

OBJECTIVES: We aimed to evaluate the safety and efficacy of the dedicated Tryton side branch (SB) stent for the treatment of true bifurcations involving large SBs. BACKGROUND: Bifurcation lesions are associated with lower procedural success and a higher risk of adverse cardiac events. Provisional stenting (PS) is currently the default approach for the treatment of bifurcation lesions. The Tryton stent is a dedicated bifurcation stent system for the treatment of true bifurcation lesions. METHODS: We performed an individual-patient-data pooled post-hoc analysis of the Tryton Pivotal randomized controlled trial and post-approval Confirmatory Study. Only patients with true bifurcations involving a SB ≥ 2.25 mm in diameter were included. The primary endpoint was non-inferiority of Tryton compared with PS for target vessel failure (TVF) at 1 year. RESULTS: Of the 411 patients meeting the criteria for enrolment, 287 patients were treated with the Tryton stent and 124 with PS. Procedural success was higher in the Tryton group (95.4 versus 82.3%, P < 0.0001). TVF at 1 year was 8.1% in the Tryton group and 9.7% in the PS group, meeting the pre-specified criteria for non-inferiority established for the randomized controlled trail (pnon-inferiority = 0.02). At 9-month angiographic follow-up, SB diameter stenosis was significantly lower in the Tryton group (29.3 ± 21.9 versus 41.1 ± 17.5, P = 0.0008) and in-segment binary restenosis (diameter stenosis ≥ 50%) was higher in the PS group (19.0 versus 34.2%, respectively, P = 0.052). CONCLUSIONS: In patients with true bifurcations involving a large SB, treatment with the Tryton SD Stent was clinically non-inferior to PS and showed favorable angiographic outcomes.


Assuntos
Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Estudos de Equivalência como Asunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Pediatr Blood Cancer ; 60(12): 2012-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23956157

RESUMO

BACKGROUND: High-dose chemotherapy with autologous hematopoietic progenitor cell rescue (AuHPCR) for pediatric patients with brain tumors has become an important therapeutic modality to avoid or delay the long-term effects of cranial irradiation. Data on post-AuHPCR infectious complications in this population are lacking. This single institution retrospective review reports the prophylactic practices and infections in the first year following AuHPCR in pediatric patients with brain tumors. PROCEDURE: The medical record of patients who underwent AuHPCR for the treatment of a malignant brain tumor at Children's Hospital Los Angeles between 1988 and 2010 were reviewed. Patients without prior irradiation who were free of disease at 1 year without additional chemotherapy were evaluated for all infectious disease complications occurring from time of neutrophil engraftment to 1 year post-AuHPCR. RESULTS: Forty-three of the 115 eligible patients were included. The median time to neutrophil engraftment was 11 days (range: 8-43 days), and 20 Grade III/IV (no Grade V) infectious episodes developed in 15 patients (35%). Fourteen episodes of bacteremia (70%) were catheter-related, predominantly gram-negative (71%), and polymicrobial (50%). There were no fungal or pneumocystis infections and only 1 of 25 (4%) at-risk patients developed VZV reactivation. CONCLUSIONS: These data suggest patients with brain tumors undergoing AuHPCR have few late-occurring non-catheter-related post-transplant infections indicating that prophylaxis practices were sufficient. Central lines should be removed soon after engraftment, but those with central line infections should receive adequate treatment including gram-negative coverage. In addition, only at-risk patients who receive further irradiation may benefit from VZV reaction prophylaxis.


Assuntos
Neoplasias Encefálicas/terapia , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Controle de Infecções/métodos , Infecções/epidemiologia , Adolescente , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/prevenção & controle , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Infecções/etiologia , Masculino , Transplante Autólogo , Adulto Jovem
6.
JACC Case Rep ; 4(4): 241-246, 2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35199025

RESUMO

We present a unique case of a paravalvular leak through a periannular channel around a bioprosthetic mitral valve. The role of multimodality imaging, in addition to novel technology, helped uncover the complex course of the jet, including its origin and direction, which translated into excellent procedural success. (Level of Difficulty: Advanced.).

7.
J Am Heart Assoc ; 10(16): e020491, 2021 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-34376060

RESUMO

Background Suprasternal access is an alternative access strategy for transcatheter aortic valve replacement (TAVR) where the innominate artery is cannulated from an incision above the sternal notch. To date, suprasternal access has never been compared with transfemoral TAVR. Thus, we sought to assess safety, feasibility, and early clinical outcomes between suprasternal and transfemoral access for patients undergoing TAVR. Methods and Results We evaluated patients from 2 institutional prospective, observational registries containing 1348 patients. Patients were selected in a 2:1 ratio (transfemoral:suprasternal) on the basis of propensity score matching. The primary outcome was in-hospital mortality, and secondary outcomes included the incidence of ischemic stroke, major bleeding, vascular injury, left bundle-branch block, and permanent pacemaker implantation at 30-day follow-up. Propensity score matching identified 89 patients undergoing suprasternal TAVR and 159 patients undergoing transfemoral TAVR suitable for analysis. There was no significant difference between suprasternal TAVR and transfemoral TAVR with respect to in-hospital mortality (1.1% versus 0.6%; odds ratio [OR], 1.80; 95% CI, 0.11-29.06; P=0.680). No patients in either cohort suffered an ischemic stroke. The incidence of major bleeding (2.2% versus 2.5%; OR, 0.89; 95% CI, 0.16-4.96; P=0.895) and vascular injury (1.1% versus 1.9%; OR, 0.59; 95% CI, 0.06-5.77; P=0.651) did not differ significantly. The frequency of left bundle-branch block (9.4% versus 15.8%; OR, 0.56; 95% CI, 0.24-1.30; P=0.177) and permanent pacemaker implantation (11.2% versus 5.9%; OR, 2.01; 95% CI, 0.75-5.45; P=0.169) were not statistically significantly different. Conclusions Suprasternal TAVR was safe and achieved promising short-term clinical outcomes when compared with transfemoral TAVR. Future studies seeking to identify the optimal alternative access site should evaluate suprasternal TAVR access alongside other substitutes for transfemoral TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Tronco Braquiocefálico , Cateterismo Periférico , Artéria Femoral , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Alabama , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Tronco Braquiocefálico/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Estudos de Viabilidade , Feminino , Artéria Femoral/diagnóstico por imagem , Mortalidade Hospitalar , Humanos , Masculino , Cidade de Nova Iorque , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Pontuação de Propensão , Estudos Prospectivos , Punções , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
8.
BMC Mol Biol ; 11: 31, 2010 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-20429939

RESUMO

BACKGROUND: Topors is a nuclear protein that co-localizes with promyelocytic leukemia bodies and has both ubiquitin and SUMO E3 ligase activity. Expression studies implicated Topors as a tumor suppressor in various malignancies. To gain insight into the function of Topors, we generated a Topors-deficient mouse strain. RESULTS: Mice homozygous for a mutant Topors allele exhibited a high rate of perinatal mortality and decreased lifespan. In addition, heterozygotes were found to have an increased incidence of malignancy, involving a variety of tissues. Consistent with this finding, primary embryonic fibroblasts lacking Topors exhibited an increased rate of malignant transformation, associated with aneuploidy and defective chromosomal segregation. While loss of Topors did not alter sensitivity to DNA-damaging or microtubule-targeting agents, cells lacking Topors exhibited altered pericentric heterochromatin, manifested by mislocalization of HP1alpha and an increase in transcription from pericentric major satellite DNA. Topors-deficient cells exhibited a transcriptional profile similar to that of cells treated with histone deacetylase inhibitors, and were resistant to the anti-proliferative effects of the histone deacetylase inhibitor trichostatin A. CONCLUSION: These results indicate a unique role for Topors in the maintenance of genomic stability and pericentric heterochromatin, as well as in cellular sensitivity to histone deacetylase inhibitors.


Assuntos
Neoplasias/genética , Proteínas Supressoras de Tumor/metabolismo , Ubiquitina-Proteína Ligases/metabolismo , Animais , Homólogo 5 da Proteína Cromobox , Fibroblastos , Instabilidade Genômica , Heterozigoto , Inibidores de Histona Desacetilases , Humanos , Ácidos Hidroxâmicos , Camundongos , Proteínas Modificadoras Pequenas Relacionadas à Ubiquitina/metabolismo , Ubiquitina-Proteína Ligases/genética
9.
Am J Cardiol ; 125(6): 916-923, 2020 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-31928720

RESUMO

The pulse amplitude ratio (PAR), the ratio of pulse pressure at the end of the Valsalva maneuver to before the onset, correlates with cardiac filling pressure. We have developed a handheld device that uses finger photoplethysmography to measure PAR and estimate left ventricular end diastolic pressure (LVEDP). Patients hospitalized with heart failure (HF) performed three 10-second trials of a standardized Valsalva maneuver (at 20 mm Hg measured via pressure transducer), while photoplethysmography waveforms were recorded, at admission and discharge. Combined primary outcome was 30-day HF hospitalization, intravenous diuresis, or death. Fifty-two subjects had discharge PAR testing; 12 met the primary outcome. Median PAR on admission was 0.55 (interquartile range: 0.40 to 0.70, n = 48) and on discharge was 0.50 (interquartile range: 0.36 to 0.69). Mean PAR-estimated LVEDP was significantly higher in subjects that had an event (20.2 vs 16.9 mm Hg, p = 0.043). Subjects with PAR-estimated LVEDP >19.5 mm Hg had an event rate hazard ratio of 4.57 (95% confidence interval 1.37, 15.19, p = 0.013) compared with patients with LVEDP 19.5 mm Hg or below, with significantly lower 30-day event-free survival (log-rank p = 0.006). In conclusion, noninvasively estimated LVEDP using the pulse amplitude response to a Valsalva maneuver in patients hospitalized for HF changes with diuresis and identifies patients at high risk for 30-day HF events. Detection of elevated filling pressures before hospital discharge may be useful in guiding HF management to reduce HF events.


Assuntos
Pressão Sanguínea/fisiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Determinação da Frequência Cardíaca/instrumentação , Hospitalização/estatística & dados numéricos , Fotopletismografia/instrumentação , Manobra de Valsalva/fisiologia , Desenho de Equipamento , Insuficiência Cardíaca/mortalidade , Humanos , Intervalo Livre de Progressão , Modelos de Riscos Proporcionais , Medição de Risco , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
10.
JACC Case Rep ; 1(5): 774-780, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-34316930

RESUMO

Patients with chronic kidney disease are at elevated risk for adverse events after traditional coronary angiography and percutaneous intervention with contrast media. The case presented in this report highlights the potential benefits of zero-contrast multivessel percutaneous coronary intervention in a patient presenting with a non-ST-segment elevation acute coronary syndrome. (Level of Difficulty: Beginner.).

11.
Coron Artery Dis ; 30(5): 346-351, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31094895

RESUMO

OBJECTIVE: We sought to describe a technique for ultra-low-contrast angiography (ULCA) in patients with advanced chronic kidney disease (CKD) and previous coronary artery bypass surgery (CABG). BACKGROUND: Patients with advanced CKD and previous CABG are at high risk of developing contrast-induced nephropathy (CIN) because of the additional contrast often required to identify bypass grafts. Apart from hydration, reduced contrast administration is the only established method to minimize the risk of CIN. PATIENTS AND METHODS: Ten patients underwent ULCA, whereby an intracoronary injection of saline and coronary guidewires were used instead of test injections of contrast for engagement of bypass grafts with catheters. Estimated glomerular filtration rate (eGFR) before and 30 days following angiography were recorded as was the need for renal replacement therapy 1 year after the procedure. RESULTS: All patients completed a diagnostic angiogram without complications. The median volume of contrast delivered was 13.5 ml (interquartile range: 10.5-17.8). The median eGFR was 18.3 ml/min/1.73 m (interquartile range: 16.5-28.2). There was no statistically significant difference in eGFR before the procedure and 30 days after the procedure (P=0.79). No patient required dialysis 30 days after the procedure. Two patients required initiation of dialysis at 1 year after the procedure. CONCLUSION: In patients with advanced CKD and previous CABG, ULCA may be performed with high procedural success and without complications, minimizing the risk of CIN in these high-risk patients.


Assuntos
Injúria Renal Aguda/prevenção & controle , Meios de Contraste/administração & dosagem , Angiografia Coronária , Ponte de Artéria Coronária , Taxa de Filtração Glomerular/efeitos dos fármacos , Rim/efeitos dos fármacos , Insuficiência Renal Crônica/complicações , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/fisiopatologia , Idoso , Meios de Contraste/efeitos adversos , Angiografia Coronária/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Feminino , Humanos , Rim/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
12.
Interv Cardiol Clin ; 7(3): 329-344, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29983145

RESUMO

Intravascular imaging plays a key role in optimizing outcomes for percutaneous coronary intervention (PCI). Optical coherence tomography (OCT) utilizes a user-friendly interface and provides high-resolution images. OCT can be used as part of daily practice in all stages of a coronary intervention: baseline lesion assessment, stent selection, and stent optimization. Incorporating a standardized, algorithmic approach when using OCT allows for precision PCI.


Assuntos
Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Algoritmos , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Métodos Epidemiológicos , Falha de Equipamento , Humanos , Guias de Prática Clínica como Assunto , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos
15.
J Cardiol Cases ; 12(6): 202-204, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26664501

RESUMO

We report the case of a 67-year-old patient who presented with anginal symptoms to the hospital. Computed tomographic angiography, to rule out a pulmonary embolism, showed a left ventricular apical outpouching. The patient underwent further imaging modalities, including contrast echocardiography (TTE) and cardiovascular magnetic resonance imaging (CMR), which were suggestive of a true left ventricular aneurysm (LVA). The absence of obstructive coronary artery disease on coronary angiography, absence of late enhancement on the CMR, and ultimately the intraoperative findings during surgical resection of the aneurysm, were strong indicators of a non-ischemic etiology of the patient's LVA. Additionally, the patient denied any previous history of cardiac instrumentation to rule out iatrogenic causes of LVA and congenital causes were excluded by a previous echocardiogram. Finally, history and presenting electrocardiogram did not reveal any other underlying obvious causes for the LVA. Excluding all common causes for the LVA an idiopathic cause seemed most likely.

16.
Biosens Bioelectron ; 67: 511-5, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25241123

RESUMO

A simple, highly sensitive and specific immunosensing assay for rapid detection and quantification of Escherichia coli O157:H7 in meat and water samples based on the electrocatalytic properties of gold nanoparticles (AuNPs) towards hydrogen evolution reaction and superparamagnetic microbeads (MBs) as pre-concentration/purification platforms without the need of broth enrichment is developed for the first time. Minced beef and water samples inoculated with different concentrations of E. coli O157:H7 have been tested using anti-E. coli O157-magnetic beads conjugate (MBs-pECAb) as a capture platform and sandwiching afterwards with AuNPs modified with secondary antibodies (AuNPs-sECAb) and detected using chronoamperometric measurement with screen-printed carbon electrodes (SPCEs). Detection limits (LOD) of 148, 457 and 309 CFU/mL were obtained in buffer solution, minced beef and tap water samples respectively, with a broad detection range of 10(2)-10(5) CFU/mL in all cases. Recoveries percentages after spiking of 5 different samples of both minced beef and tap water with 10(3) and 10(4) CFU/mL were 94.7 and 90.4 (in beef) and 91.3 and 94.8% (in water), respectively. Specificity, reproducibility and comparison with a commercial lateral flow kit in terms of LOD and detection range were also studied showing clear advantages of the electrochemical method performance. The successful application of this AuNPs based technology in minced beef and tap water indicates the possibility of its using in various food items and other water resources.


Assuntos
Técnicas Biossensoriais , Escherichia coli O157/isolamento & purificação , Produtos da Carne/microbiologia , Microbiologia da Água , Animais , Bovinos , Escherichia coli O157/patogenicidade , Microbiologia de Alimentos , Ouro/química , Nanopartículas/química
19.
World J Gastroenterol ; 19(7): 1135-9, 2013 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-23467442

RESUMO

A 39-year-old male reported fevers, weight loss, watery loose stools, and decreased visual acuity in his right eye over the prior five years. He was pancytopenic, had an elevated American council on exercise level, total bilirubin, and alkaline phosphatase. Computed tomography revealed massive hepatosplenomegaly and emphysematous lung changes. Liver biopsy showed non caseating granulomas. The patient was diagnosed with extrapulmonary sarcoidosis and was treated with prednisone. The patient symptomatically improved but 5 mo later presented with abdominal pain caused by perforation of the cecum. He underwent a cecectomy and pathology revealed pneumatosis cystoides intestinalis. This represents the first reported association between pneumatosis cystoides intestinalis and sarcoidosis. The etiology of pneumatosis cystoides intestinalis in this case was likely multifactorial and involved both effects of the corticosteroids as well as the advanced nature of the gastrointestinal sarcoidosis. Furthermore this case has the unique features of emphysematous lung changes and pancytopenia which are uncommon with sarcoidosis.


Assuntos
Enteropatias/complicações , Pneumatose Cistoide Intestinal/etiologia , Sarcoidose/complicações , Adulto , Biópsia , Glucocorticoides/efeitos adversos , Humanos , Enteropatias/diagnóstico , Enteropatias/tratamento farmacológico , Masculino , Pneumatose Cistoide Intestinal/diagnóstico , Pneumatose Cistoide Intestinal/terapia , Prednisona/efeitos adversos , Fatores de Risco , Sarcoidose/diagnóstico , Sarcoidose/tratamento farmacológico , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
PLoS One ; 8(7): e69851, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23922822

RESUMO

Several epidemiological studies have suggested a link between melanoma and breast cancer. Metabotropic glutamate receptor 1 (GRM1), which is involved in many cellular processes including proliferation and differentiation, has been implicated in melanomagenesis, with ectopic expression of GRM1 causing malignant transformation of melanocytes. This study was undertaken to evaluate GRM1 expression and polymorphic variants in GRM1 for associations with breast cancer phenotypes. Three single nucleotide polymorphisms (SNPs) in GRM1 were evaluated for associations with breast cancer clinicopathologic variables. GRM1 expression was evaluated in human normal and cancerous breast tissue and for in vitro response to hormonal manipulation. Genotyping was performed on genomic DNA from over 1,000 breast cancer patients. Rs6923492 and rs362962 genotypes associated with age at diagnosis that was highly dependent upon the breast cancer molecular phenotype. The rs362962 TT genotype also associated with risk of estrogen receptor or progesterone receptor positive breast cancer. In vitro analysis showed increased GRM1 expression in breast cancer cells treated with estrogen or the combination of estrogen and progesterone, but reduced GRM1 expression with tamoxifen treatment. Evaluation of GRM1 expression in human breast tumor specimens demonstrated significant correlations between GRM1 staining with tissue type and molecular features. Furthermore, analysis of gene expression data from primary breast tumors showed that high GRM1 expression correlated with a shorter distant metastasis-free survival as compared to low GRM1 expression in tamoxifen-treated patients. Additionally, induced knockdown of GRM1 in an estrogen receptor positive breast cancer cell line correlated with reduced cell proliferation. Taken together, these findings suggest a functional role for GRM1 in breast cancer.


Assuntos
Neoplasias da Mama/genética , Neoplasias da Mama/patologia , Estudos de Associação Genética , Predisposição Genética para Doença , Polimorfismo de Nucleotídeo Único/genética , Receptores de Glutamato Metabotrópico/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/classificação , Neoplasias da Mama/epidemiologia , Proliferação de Células/efeitos dos fármacos , Estudos de Coortes , Demografia , Intervalo Livre de Doença , Estradiol/farmacologia , Receptor alfa de Estrogênio/metabolismo , Feminino , Regulação Neoplásica da Expressão Gênica/efeitos dos fármacos , Humanos , Incidência , Pessoa de Meia-Idade , Metástase Neoplásica , Recidiva Local de Neoplasia/genética , Recidiva Local de Neoplasia/patologia , Fenótipo , Fosforilação/efeitos dos fármacos , Receptores de Glutamato Metabotrópico/metabolismo , Tamoxifeno/análogos & derivados , Tamoxifeno/farmacologia , Análise Serial de Tecidos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA