1.
Clin Transplant ; 31(10)2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28766759

RESUMO

Complement-dependent cytotoxicity cross-match (CDCXM) is used for evaluation of preformed HLA-specific antibodies in patients undergoing heart transplantation. Flow cytometry cross-match (FCXM) is a more sensitive assay and used with increasing frequency. To determine the clinical relevance of a positive FCXM in the context of negative CDCXM in heart transplantation, the United Network for Organ Sharing (UNOS) database was analyzed. Kaplan-Meier analysis and Cox proportional hazard modeling were used to assess graft survival for three different patient cohorts defined by cross-match results: T-cell and B-cell CDCXM+ ("CDCXM+" cohort), CDCXM- but T-cell and/or B-cell FCXM+ ("FCXM+" cohort), and T-cell/B-cell CDCXM- and FCXM- ("XM-" cohort). During the study period, 2558 patients met inclusion criteria (10.7% CDCXM+, 18.8% FCXM+, 65.5% XM-). CDCXM+ patients had significantly decreased graft survival compared to FCXM+ and XM- cohorts (P = .003 and <.001, respectively). CDCXM- and FCXM+ patients did not have decreased graft survival compared to XM- patients (P = .09). In multivariate analysis, only CDCXM+ was associated with decreased graft survival (HR 1.22, 95% CI 1.01-1.49). In conclusion, positive FCXM in the context of negative CDCXM does not confer increased risk of graft failure. Further study is needed to understand implications of CDCXM and FCXM testing in heart transplant recipients.


Assuntos
Proteínas do Sistema Complemento/imunologia , Testes Imunológicos de Citotoxicidade/métodos , Citometria de Fluxo/métodos , Rejeição de Enxerto/diagnóstico , Sobrevivência de Enxerto/imunologia , Transplante de Coração/efeitos adversos , Teste de Histocompatibilidade/métodos , Adulto , Feminino , Seguimentos , Rejeição de Enxerto/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco
2.
J Card Surg ; 32(11): 741-745, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29178215

RESUMO

Aortic insufficiency following left ventricular assist device implantation (LVAD) has been reported in up to 40% of patients and is associated with a worse prognosis. We describe the case of a successful transfemoral transcatheter aortic valve replacement with a self-expanding bioprosthesis for aortic insufficiency following destination LVAD implantation.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Ventrículos do Coração , Coração Auxiliar , Substituição da Valva Aórtica Transcateter/métodos , Adulto , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/terapia , Ecocardiografia Transesofagiana , Artéria Femoral , Humanos , Masculino , Índice de Gravidade de Doença , Resultado do Tratamento , Adulto Jovem
3.
Bioelectricity ; 3(3): 171-175, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34729463

RESUMO

Undisturbed bioelectricity is a prerequisite for normal organ function. This is especially true for organs with high electrical activity such as the heart and the nervous system. Under clinical conditions, however, this can hardly be determined in patients with disturbed organ function and is therefore largely ignored. Here, based on clinical data, we will discuss whether the direct application of an external electric current (in the physiological µA range) together with an electrical field to hearts with impaired pump function can explain the functional improvement of the hearts by edema reduction triggered by electro-osmosis.

4.
ESC Heart Fail ; 8(2): 962-970, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33559358

RESUMO

AIMS: Most devices for treating ambulatory Class II and III heart failure are linked to electrical pulses. However, a steady electric potential gradient is also necessary for appropriate myocardial performance and may be disturbed by structural heart diseases. We investigated whether chronic application of electrical microcurrent to the heart is feasible and safe and improves cardiac performance. The results of this study should provide guidance for the design of a two-arm, randomized, controlled Phase II trial. METHODS AND RESULTS: This single-arm, non-randomized pilot study involved 10 patients (9 men; mean age, 62 ± 12 years) at two sites with 6 month follow-up. All patients had New York Heart Association (NYHA) Class III heart failure and non-ischaemic dilated cardiomyopathy, with left ventricular ejection fraction (LVEF) <35%. A device was surgically placed to deliver a constant microcurrent to the heart. The following tests were performed at baseline, at hospital discharge, and at six time points during follow-up: determination of LVEF and left ventricular end-diastolic/end-systolic diameter by echocardiography; the 6 min walk test; and assessment of NYHA classification and quality of life (36-Item Short-Form Health Survey questionnaire). Microcurrent application was feasible and safe; no device-related or treatment-related adverse events occurred. During follow-up, rapid and significant signal of efficacy (P < 0.005) was present with improvements in LVEF, left ventricular end-diastolic diameter, left ventricular end-systolic diameter, and distance walked. For eight patients, NYHA classification improved from Class III to Class I (for seven, as early as 14 days post-operatively); for one, to Class II; and for one, to Class II/III. 36-Item Short-Form Health Survey questionnaire scores also improved highly significantly. CONCLUSIONS: Chronic application of microcurrent to the heart is feasible and safe and leads to a rapid and lasting improvement in heart function and a near normalization of heart size within days. The NYHA classification and quality of life improve just as rapidly.


Assuntos
Insuficiência Cardíaca , Qualidade de Vida , Idoso , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
5.
Semin Thorac Cardiovasc Surg ; 32(4): 738-746, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-30308249

RESUMO

This study aims to identify the major components of left ventricular assist device (LVAD)-related costs in a population on long-term mechanical circulatory support to gain insight into opportunities for improvements in quality, safety, and efficiency of care for end-stage heart failure patients. This was a single institution, retrospective cost analysis of patients who received a Heartmate II or HeartWare LVAD between November 2005 and October 2015. Payments for hospitalization for device implantation and subsequent readmissions were represented as the institution's 2015 Medicare reimbursement rate. The incidence, average Medicare reimbursement, and length of stay of readmissions were analyzed for the first year postimplant. A full year of LVAD-related hospitalizations in patients surviving ≥12 months, has a median Medicare reimbursement of $247,208. The most common complications related to ventricular assist devices were gastrointestinal bleeding, driveline infection, stroke, and pump thrombosis. Over 90% of total costs were incurred during the initial hospitalization. Seventy-five percent of first-time readmissions occurred within the first 4 months post discharge. Intensive care unit costs accounted for the single largest cost category during readmissions for all of the 4 most common complications. The trends demonstrated suggest that longer lengths of LVAD support in appropriately selected patients results in progressively decreasing cost-per-month up to 12 months, given the large upfront cost of device implantation and relatively modest additional costs of readmissions. This analysis emphasizes the importance of devices with improved complication profiles and clinical protocols to reduce unnecessary intensive care unit stays to increase the cost effectiveness of long-term ventricular assist device therapy.


Assuntos
Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Coração Auxiliar/economia , Custos Hospitalares , Hospitalização/economia , Implantação de Prótese/economia , Função Ventricular Esquerda , Adulto , Idoso , Análise Custo-Benefício , Cuidados Críticos/economia , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Tempo de Internação/economia , Masculino , Medicare/economia , Pessoa de Meia-Idade , Readmissão do Paciente/economia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/mortalidade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos