Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Appl Physiol ; 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38683403

RESUMO

PURPOSE: Heart rate (HR) response is likely to vary in people with Parkinson's disease (PD), particularly for those with chronotropic incompetence (CI). This study explores the impact of CI on HR and metabolic responses during cardiopulmonary exercise test (CPET) in people with PD, and its implications for exercise intensity prescription. METHODS: Twenty-eight participants with mild PD and seventeen healthy controls underwent CPET to identify the presence or absence of CI. HR and metabolic responses were measured at submaximal (first (VT1) and second (VT2) ventilatory thresholds), and at peak exercise. Main outcome measures were HR, oxygen consumption (VO2), and changes in HR responses (HR/WR slope) to an increase in exercise demand. RESULTS: CI was present in 13 (46%) PD participants (PDCI), who during CPET, exhibited blunted HR responses compared to controls and PD non-CI beyond 60% of maximal workload (p ≤ 0.05). PDCI presented a significantly lower HR at VT2, and peak exercise compared to PD non-CI and controls (p ≤ 0.001). VO2 was significantly lower in PDCI than PD non-CI and controls at VT2 (p = 0.003 and p = 0.036, respectively) and at peak exercise (p = 0.001 and p = 0.023, respectively). CONCLUSION: Although poorly understood, the presence of CI in PD and its effect on HR and metabolic responses during incremental exercise is significant and important to consider when programming aerobic exercises.

2.
J Arthroplasty ; 38(8): 1516-1521, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36805116

RESUMO

BACKGROUND: There appears to be substantial variability in outcomes > 2 years following total knee arthroplasty (TKA) that is masked by whole group analyses. The goal of the study was to identify trajectories of pain and function outcomes up to 5 to 8 years post-TKA and to identify baseline factors that are associated with different trajectories of recovery. METHODS: Baseline, 6-month, and 12-month pain and function data were collected in a previous study investigating predictors of outcome following primary TKA (n = 286), along with a variety of baseline predictor variables. The present study obtained pain and function data at 5 to 8 years following TKA in the same cohort (n = 201). Latent class linear mixed models were used to identify different classes of pain and functional trajectories over time. The extent to which differences across latent classes were explained by baseline predictor variables was determined. RESULTS: Three classes of pain and two classes of function trajectory were identified. While most patients (84% to 93%) followed a trajectory that showed an initial rapid gain following surgery that was sustained through 5 to 8 years, both pain and function included at least one trajectory class that showed a meaningful change after 12 months. No predictor variables were significantly associated with either the pain or function classes. CONCLUSIONS: Most patients follow a traditional trajectory of recovery in knee pain and function over 5 to 8 years. However, alternative trajectories are observed in an important minority of patients such that knee pain and function at 12 months after surgery does not always reflect outcomes at 5 to 8 years.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Dor/cirurgia , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/complicações , Resultado do Tratamento
3.
Sensors (Basel) ; 23(24)2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38139564

RESUMO

Smartphone applications (apps) that utilize embedded inertial sensors have the potential to provide valid and reliable estimations of different balance and gait parameters in older adults with mild balance impairment. This study aimed to assess the reliability, validity, and sensitivity of the Gait&Balance smartphone application (G&B App) for measuring gait and balance in a sample of middle- to older-aged adults with mild balance impairment in Pakistan. Community-dwelling adults over 50 years of age (N = 83, 50 female, range 50-75 years) with a Berg Balance Scale (BBS) score between 46/56 and 54/56 were included in the study. Data collection involved securing a smartphone to the participant's lumbosacral spine. Participants performed six standardized balance tasks, including four quiet stance tasks and two gait tasks (walking looking straight ahead and walking with head turns). The G&B App collected accelerometry data during these tasks, and the tasks were repeated twice to assess test-retest reliability. The tasks in quiet stance were also recorded with a force plate, a gold-standard technology for measuring postural sway. Additionally, participants completed three clinical measures, the BBS, the Functional Reach Test (FRT), and the Timed Up and Go Test (TUG). Test-retest reliability within the same session was determined using intraclass correlation coefficients (ICCs) and the standard error of measurement (SEM). Validity was evaluated by correlating the G&B App outcomes against both the force plate data and the clinical measures using Pearson's product-moment correlation coefficients. To assess the G&B App's sensitivity to differences in balance across tasks and repetitions, one-way repeated measures analyses of variance (ANOVAs) were conducted. During quiet stance, the app demonstrated moderate reliability for steadiness on firm (ICC = 0.72) and compliant surfaces (ICC = 0.75) with eyes closed. For gait tasks, the G&B App indicated moderate to excellent reliability when walking looking straight ahead for gait symmetry (ICC = 0.65), walking speed (ICC = 0.93), step length (ICC = 0.94), and step time (ICC = 0.84). The TUG correlated with app measures under both gait conditions for walking speed (r -0.70 and 0.67), step length (r -0.56 and -0.58), and step time (r 0.58 and 0.50). The BBS correlated with app measures of walking speed under both gait conditions (r 0.55 and 0.51) and step length when walking with head turns (r = 0.53). Force plate measures of total distance wandered showed adequate to excellent correlations with G&B App measures of steadiness. Notably, G&B App measures of walking speed, gait symmetry, step length, and step time, were sensitive to detecting differences in performance between standard walking and the more difficult task of walking with head turns. This study demonstrates the G&B App's potential as a reliable and valid tool for assessing some gait and balance parameters in middle-to-older age adults, with promise for application in low-income countries like Pakistan. The app's accessibility and accuracy could enhance healthcare services and support preventive measures related to fall risk.


Assuntos
Aplicativos Móveis , Humanos , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Equilíbrio Postural , Reprodutibilidade dos Testes , Estudos de Tempo e Movimento , Marcha
4.
Int J Mol Sci ; 24(10)2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37240030

RESUMO

Efficient coordination between Mg2+ and vitamin D maintains adequate Ca2+ levels during lactation. This study explored the possible interaction between Mg2+ (0.3, 0.8, and 3 mM) and 1,25-dihydroxyvitamin D3 (1,25D; 0.05 and 5 nM) during osteogenesis using bovine mesenchymal stem cells. After 21 days, differentiated osteocytes were subjected to OsteoImage analysis, alkaline phosphatase (ALP) activity measurements, and immunocytochemistry of NT5E, ENG (endoglin), SP7 (osterix), SPP1 (osteopontin), and the BGLAP gene product osteocalcin. The mRNA expression of NT5E, THY1, ENG, SP7, BGLAP, CYP24A1, VDR, SLC41A1, SLC41A2, SLC41A3, TRPM6, TRPM7, and NIPA1 was also assessed. Reducing the Mg2+ concentration in the medium increased the accumulation of mineral hydroxyapatite and ALP activity. There was no change in the immunocytochemical localization of stem cell markers. Expression of CYP24A1 was higher in all groups receiving 5 nM 1,25D. There were tendencies for higher mRNA abundance of THY1, BGLAP, and NIPA1 in cells receiving 0.3 mM Mg2+ and 5 nM 1,25D. In conclusion, low levels of Mg2+ greatly enhanced the deposition of bone hydroxyapatite matrix. The effect of Mg2+ was not modulated by 1,25D, although the expression of certain genes (including BGLAP) tended to be increased by the combination of low Mg2+ and high 1,25D concentrations.


Assuntos
Cálcio , Magnésio , Feminino , Animais , Bovinos , Cálcio/metabolismo , Magnésio/farmacologia , Magnésio/metabolismo , Regulação da Expressão Gênica , Vitamina D3 24-Hidroxilase/genética , Vitamina D3 24-Hidroxilase/metabolismo , Vitamina D/metabolismo , RNA Mensageiro , Hidroxiapatitas/metabolismo
5.
J Hand Ther ; 36(3): 593-605, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35953335

RESUMO

PURPOSE: Following surgical repair of distal radius fractures, range of movement (ROM) exercises are the primary approach for restoring movement during early rehabilitation. Specified purposeful activities can also be used, but the movement produced by activities is not well-understood. The study aimed to evaluate and compare movement during purposeful activity and ROM exercises METHODS: Thirty-five adults with a surgically repaired distal radius facture undertook two 10-minutes interventions: purposeful activity (PA) and active ROM exercises (AE), separated by a 60 minute washout, in random order. Data collection occurred during a single session on the same day. Electrogoniometry was used to measure time-accumulated position (TAP), a global metric of movement range and amount, maximum active end range, movement repetitions, excursions >75% of available ROM, and active time. Data were analyzed using linear mixed and generalized linear mixed regression models. RESULTS: Purposeful activities selected were predominantly household or food preparation. TAP was significantly higher during AE than PA: -1878 [-2388, -1367], p ≤.001, for wrist extension/flexion. PA produced significantly greater movement repetitions for wrist extension/flexion and deviation, excursions beyond 75% of available ROM, and active time, than AE. During PA the wrist was extending/flexing a mean of 97% [92, 101], of the time, compared with 43% [40, 47], during AE. There were no significant differences in maximum end range for wrist extension between PA, 33.7° [29.8, 37.5] and AE, 34.5° [30.7, 38.4], or for ulnar deviation. CONCLUSIONS: ROM exercises produced higher volumes of sustained joint position than purposeful activity but activities, selected for importance and challenge, produced significantly higher volumes of continuous, repetitious motion in equivalent ranges of movement as exercise repetitions. The study challenges therapists to consider the rehabilitative potential of movement produced by activity for restoring movement and function in the early postoperative weeks.

6.
Pain Med ; 22(4): 948-960, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33001213

RESUMO

OBJECTIVE: Chronic pain is a leading cause of disability in low- and middle-income countries; however, pain assessment tools have generally been developed and validated in high-income countries. This study examines the psychometric properties of a set of translated pain (and distress) questionnaires in Mongolia and documents the characteristics of people seeking treatment for chronic pain in Mongolia, compared with those in New Zealand, which is representative of high-income countries. DESIGN: Cross-sectional, observational. SETTING: Hospital-based pain treatment centers in New Zealand and Mongolia. SUBJECTS: People seeking treatment for chronic pain in Mongolia (N = 142) and New Zealand (N = 159). METHODS: The Brief Pain Inventory, the Depression Anxiety Stress Scale-21, the Pain Catastrophizing Scale, and the Pain Self-Efficacy Questionnaire were translated into Mongolian and administered to patients attending a hospital-based pain service. Questionnaires that were completed by patients in New Zealand were used for comparisons. Internal reliability, convergent validity, and factor structure were assessed in both groups. RESULTS: Patients in Mongolia were older and reported lower pain intensity, interference, and distress and higher pain self-efficacy than those in New Zealand. The translated questionnaires had good internal consistencies, and the relationships between pain variables were similar across both groups. The factor structure for the Pain Catastrophizing Scale was consistent across both groups, but this was not the case for the Brief Pain Inventory or the Depression Anxiety Stress Scale-21. CONCLUSIONS: Findings indicate that some pain outcome measures may be appropriate for use in Mongolia and should be investigated in other low- and middle-income countries.


Assuntos
Dor Crônica , Dor Crônica/diagnóstico , Estudos Transversais , Países em Desenvolvimento , Humanos , Nova Zelândia , Medição da Dor , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários
7.
BMC Vet Res ; 17(1): 388, 2021 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-34922529

RESUMO

BACKGROUND: Mesenchymal stem cells (MSCs) are undifferentiated cells that can give rise to a mesoderm lineage. Adipose-derived MSCs are an easy and accessible source for MSCs isolation, although each source of MSC has its own advantages and disadvantages. Our study identifies a promising source for the isolation and differentiation of canines MSCs. For this purpose, adipose tissue from inguinal subcutaneous (SC), perirenal (PR), omental (OM), and infrapatellar fat pad (IPFP) was isolated and processed for MSCs isolation. In the third passage, MSCs proliferation/metabolism, surface markers expression, in vitro differentiation potential and quantitative reverse transcription PCR (CD73, CD90, CD105, PPARγ, FabP4, FAS, SP7, Osteopontin, and Osteocalcin) were evaluated. RESULTS: Our results showed that MSCs derived from IPFP have a higher proliferation rate, while OM-derived MSCs have higher cell metabolism. In addition, MSCs from all adipose tissue sources showed positive expression of CD73 (NT5E), CD90 (THY1), CD105 (ENDOGLIN), and very low expression of CD45. The isolated canine MSCs were successfully differentiated into adipogenic and osteogenic lineages. The oil-red-O quantification and adipogenic gene expression (FAS, FabP4, and PPARγ) were higher in OM-derived cells, followed by IPFP-MSCs. Similarly, in osteogenic differentiation, alkaline phosphatase activity and osteogenic gene (SP7 and Osteocalcin) expression were higher in OM-derived MSCs, while osteopontin expression was higher in PR-derived MSCs. CONCLUSION: In summary, among all four adipose tissue sources, OM-derived MSCs have better differentiation potential toward adipo- and osteogenic lineages, followed by IPFP-MSCs. Interestingly, among all adipose tissue sources, MSCs derived from IPFP have the maximum proliferation potential. The characterization and differentiation potential of canine MSCs isolated from four different adipose tissue sources are useful to assess their potential for application in regenerative medicine.


Assuntos
Tecido Adiposo/citologia , Diferenciação Celular , Células-Tronco Mesenquimais , Osteogênese , Animais , Proliferação de Células , Células Cultivadas , Cães , Células-Tronco Mesenquimais/citologia , Osteocalcina , Osteopontina , PPAR gama
8.
Sensors (Basel) ; 22(1)2021 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-35009667

RESUMO

Advances in technology provide an opportunity to enhance the accuracy of gait and balance assessment, improving the diagnosis and rehabilitation processes for people with acute or chronic health conditions. This study investigated the validity and reliability of a smartphone-based application to measure postural stability and spatiotemporal aspects of gait during four static balance and two gait tasks. Thirty healthy participants (aged 20-69 years) performed the following tasks: (1) standing on a firm surface with eyes opened, (2) standing on a firm surface with eyes closed, (3) standing on a compliant surface with eyes open, (4) standing on a compliant surface with eyes closed, (5) walking in a straight line, and (6) walking in a straight line while turning their head from side to side. During these tasks, the app quantified the participants' postural stability and spatiotemporal gait parameters. The concurrent validity of the smartphone app with respect to a 3D motion capture system was evaluated using partial Pearson's correlations (rp) and limits of the agreement (LoA%). The within-session test-retest reliability over three repeated measures was assessed with the intraclass correlation coefficient (ICC) and the standard error of measurement (SEM). One-way repeated measures analyses of variance (ANOVAs) were used to evaluate responsiveness to differences across tasks and repetitions. Periodicity index, step length, step time, and walking speed during the gait tasks and postural stability outcomes during the static tasks showed moderate-to-excellent validity (0.55 ≤ rp ≤ 0.98; 3% ≤ LoA% ≤ 12%) and reliability scores (0.52 ≤ ICC ≤ 0.92; 1% ≤ SEM% ≤ 6%) when the repetition effect was removed. Conversely, step variability and asymmetry parameters during both gait tasks generally showed poor validity and reliability except step length asymmetry, which showed moderate reliability (0.53 ≤ ICC ≤ 0.62) in both tasks when the repetition effect was removed. Postural stability and spatiotemporal gait parameters were found responsive (p < 0.05) to differences across tasks and test repetitions. Along with sound clinical judgement, the app can potentially be used in clinical practice to detect gait and balance impairments and track the effectiveness of rehabilitation programs. Further evaluation and refinement of the app in people with significant gait and balance deficits is needed.


Assuntos
Aplicativos Móveis , Marcha , Humanos , Equilíbrio Postural , Reprodutibilidade dos Testes , Smartphone , Caminhada , Velocidade de Caminhada
9.
Biogerontology ; 21(2): 203-216, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31792648

RESUMO

One of the most significant hallmarks of aging is cognitive decline. D-galactose administration may impair memory and mimic the effects of natural aging. In this study, the efficiency of goat milk to protect against memory decline was tested. Fifty-two male Sprague-Dawley rats were randomly divided into four groups: (i) control group, (ii) goat milk treated group, (iii) D-galactose treated group, and (iv) goat milk plus D-galactose treated group. Subcutaneous injections of D-galactose at 120 mg/kg and oral administrations of goat milk at 1 g/kg were chosen for the study. Goat milk and D-galactose were administered concomitantly for 6 weeks, while the control group received saline. After 6 weeks, novel object recognition and T-maze tests were performed to evaluate memory of rats. Following behavioral tests, the animals were sacrificed, and right brain homogenates were analyzed for levels of lipid peroxidation, antioxidant enzymes and neurotrophic factors. The left brain hemisphere was used for histological study of prefrontal cortex and hippocampus. There was a significant memory impairment, an increase in oxidative stress and neurodegeneration and a reduction in antioxidant enzymes and neurotrophic factors levels in the brain of D-galactose treated rats compared to controls. Goat milk treatment attenuated memory impairment induced by D-galactose via suppressing oxidative stress and neuronal damage and increasing neurotrophic factors levels, thereby suggesting its potential role as a geroprotective food.


Assuntos
Comportamento Animal , Encéfalo/metabolismo , Envelhecimento Cognitivo , Transtornos da Memória/prevenção & controle , Memória , Leite , Degeneração Neural , Fatores de Crescimento Neural/metabolismo , Estresse Oxidativo , Fatores Etários , Animais , Antioxidantes/metabolismo , Encéfalo/patologia , Modelos Animais de Doenças , Galactose , Cabras , Masculino , Transtornos da Memória/induzido quimicamente , Transtornos da Memória/metabolismo , Transtornos da Memória/patologia , Ratos Sprague-Dawley
10.
BMC Infect Dis ; 20(1): 874, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33228562

RESUMO

BACKGROUND: Pakistan is facing a growing population of people living with human immunodeficiency (HIV). In this randomized controlled trial, we investigate if a pharmacist-led intervention can increase adherence to antiretroviral therapy (ART) for people living with HIV (PLWH). METHODS: Adults with HIV, who have been taking ART for more than 3 months were randomly assigned to receive either a pharmacist-led intervention or their usual care. Measures of adherence were collected at 1) baseline 2) just prior to delivery of intervention and 3) 8 weeks later. The primary outcomes were CD4 cell count and self-reported adherence measured with the AIDS Clinical Trial Group (ACTG) questionnaire. RESULTS: Post-intervention, the intervention group showed a statistically significant increase in CD4 cell counts as compared to the usual care group (p = 0.0054). In addition, adherence improved in the intervention group, with participants being 5.96 times more likely to report having not missed their medication for longer periods of time (p = 0.0086) while participants in the intervention group were 7.74 times more likely to report missing their ART less frequently (p < 0.0001). CONCLUSIONS: The findings support the improvement in ART adherence and HIV management. TRIAL REGISTRATION: The trial is registered with Australian New Zealand Clinical Trials Registry ( ACTRN12618001882213 ). Registered 20 November 2018.


Assuntos
Antirretrovirais/uso terapêutico , Aconselhamento/métodos , Infecções por HIV/tratamento farmacológico , HIV/imunologia , Adesão à Medicação/psicologia , Farmacêuticos/psicologia , Adulto , Contagem de Linfócito CD4 , Feminino , Infecções por HIV/epidemiologia , Infecções por HIV/virologia , Humanos , Masculino , Pessoa de Meia-Idade , Paquistão/epidemiologia , Fatores de Risco , Autorrelato , Método Simples-Cego , Resultado do Tratamento , Adulto Jovem
11.
Sensors (Basel) ; 20(8)2020 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-32344692

RESUMO

Event related potentials (ERPs) provide insight into the neural activity generated in response to motor, sensory and cognitive processes. Despite the increasing use of ERP data in clinical research little is known about the reliability of human manual ERP labelling methods. Intra-rater and inter-rater reliability were evaluated in five electroencephalography (EEG) experts who labelled the peak negativity of averaged movement related cortical potentials (MRCPs) derived from thirty datasets. Each dataset contained 50 MRCP epochs from healthy people performing cued voluntary or imagined movement, or people with stroke performing cued voluntary movement. Reliability was assessed using the intraclass correlation coefficient and standard error of measurement. Excellent intra- and inter-rater reliability was demonstrated in the voluntary movement conditions in healthy people and people with stroke. In comparison reliability in the imagined condition was low to moderate. Post-hoc secondary epoch analysis revealed that the morphology of the signal contributed to the consistency of epoch inclusion; potentially explaining the differences in reliability seen across conditions. Findings from this study may inform future research focused on developing automated labelling methods for ERP feature extraction and call to the wider community of researchers interested in utilizing ERPs as a measure of neurophysiological change or in the delivery of EEG-driven interventions.


Assuntos
Potenciais Evocados/fisiologia , Acidente Vascular Cerebral/fisiopatologia , Adulto , Idoso , Intervalos de Confiança , Eletroencefalografia , Processamento Eletrônico de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
12.
Sensors (Basel) ; 18(11)2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30388836

RESUMO

Texas Instruments ADS1299 is an attractive choice for low cost electroencephalography (EEG) devices owing to its low power consumption and low input referred noise. To date, there have been no rigorous evaluations of its performance. In this EEG experimental study we evaluated the performance of the ADS1299 against a high quality laboratory-based system. Two self-paced lower limb motor tasks were performed by 22 healthy participants. Recorded power across delta, theta, alpha, and beta EEG bands, the power ratio across the motor tasks, pre-movement noise, and signal-to-noise ratio were obtained for evaluation. The amplitude and time of the negative peak in the movement-related cortical potentials (MRCPs) extracted from the EEG data were also obtained. Using linear mixed models, no statistically significant differences (p > 0.05) were found in any of these measures across the two systems. These findings were further supported by evaluation of cosine similarity, waveform differences, and topographic maps. There were statistically significant differences in MRCPs across the motor tasks in both systems. We conclude that the performance of the ADS1299 in combination with wet Ag/AgCl electrodes is analogous to that of a laboratory-based system in a low frequency (<40 Hz) EEG recording.

13.
Sensors (Basel) ; 18(11)2018 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-30400325

RESUMO

Brain-computer interfaces (BCIs) can be used to induce neural plasticity in the human nervous system by pairing motor cortical activity with relevant afferent feedback, which can be used in neurorehabilitation. The aim of this study was to identify the optimal type or combination of afferent feedback modalities to increase cortical excitability in a BCI training intervention. In three experimental sessions, 12 healthy participants imagined a dorsiflexion that was decoded by a BCI which activated relevant afferent feedback: (1) electrical nerve stimulation (ES) (peroneal nerve-innervating tibialis anterior), (2) passive movement (PM) of the ankle joint, or (3) combined electrical stimulation and passive movement (Comb). The cortical excitability was assessed with transcranial magnetic stimulation determining motor evoked potentials (MEPs) in tibialis anterior before, immediately after and 30 min after the BCI training. Linear mixed regression models were used to assess the changes in MEPs. The three interventions led to a significant (p < 0.05) increase in MEP amplitudes immediately and 30 min after the training. The effect sizes of Comb paradigm were larger than ES and PM, although, these differences were not statistically significant (p > 0.05). These results indicate that the timing of movement imagery and afferent feedback is the main determinant of induced cortical plasticity whereas the specific type of feedback has a moderate impact. These findings can be important for the translation of such a BCI protocol to the clinical practice where by combining the BCI with the already available equipment cortical plasticity can be effectively induced. The findings in the current study need to be validated in stroke populations.


Assuntos
Interfaces Cérebro-Computador , Retroalimentação , Plasticidade Neuronal , Adulto , Potencial Evocado Motor , Feminino , Humanos , Masculino , Modelos Estatísticos , Curva ROC , Fatores de Tempo
14.
J Biomech ; 162: 111899, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38128468

RESUMO

Smartphone accelerometry has potential to provide clinicians with specialized gait analysis not available in most clinical settings. The Gait&Balance Application (G&B App) uses smartphone accelerometry to assess spatiotemporal gait parameters under two conditions: walking looking straight ahead and walking with horizontal head turns. This study investigated the validity of G&B App gait parameters compared with the GAITRite® pressure-sensitive walkway. Healthy young and older adults (age range 21-85 years) attended a single session where a smartphone was secured over the lumbosacral junction. Data were collected concurrently with the app and GAITRite® systems as participants completed the two walking conditions. Spatiotemporal gait parameters for 54 participants were determined from both systems and agreement evaluated with partial Pearson's correlation coefficients and limits of agreement. The results demonstrated moderate to excellent validity for G&B App measures of step time (rp 0.97, 95 % CI [0.96, 0.98]), walking speed (rp 0.83 [0.78, 0.87]), and step length (rp 0.74, [0.66, 0.80]) when walking looking straight ahead, and results were comparable with head turns. The validity of walking speed and step length measures was influenced by sex and height. G&B App measures of step length variability, step time variability, step length asymmetry, and step time asymmetry had poor validity. The G&B App has potential to provide valid measures of unilateral and bilateral step time, unilateral and bilateral step length, and walking speed, under two walking conditions in healthy young and older adults. Further research should validate this tool in clinical conditions and optimise the algorithm for demographic characteristics.


Assuntos
Marcha , Smartphone , Humanos , Idoso , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Caminhada , Velocidade de Caminhada , Análise da Marcha , Reprodutibilidade dos Testes
15.
Front Psychol ; 15: 1323397, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38770250

RESUMO

Background: Attention deficit hyperactivity disorder (ADHD) is a neurobiological disorder characterized by inattention, hyperactivity, and impulsivity. We hypothesized that chiropractic adjustments could improve these symptoms by enhancing prefrontal cortex function. This pilot study aimed to explore the feasibility and efficacy of 4 weeks of chiropractic adjustment on inattention, hyperactivity, and impulsivity in children with ADHD. Methods: 67 children with ADHD were randomly allocated to receive either chiropractic adjustments plus usual care (Chiro+UC) or sham chiropractic plus usual care (Sham+UC). The Vanderbilt ADHD Diagnostic Teacher Rating Scale (VADTRS), Swanson, Nolan and Pelham Teacher and Parents Rating Scale (SNAP-IV), and ADHD Rating Scale-IV were used to assess outcomes at baseline, 4 weeks, and 8 weeks. Feasibility measures such as recruitment, retention, blinding, safety, and adherence were recorded. Linear mixed regression models were used for data analysis. Results: 56 participants (mean age ± SD: 10.70 ± 3.93 years) were included in the analysis. Both the Chiro+UC and Sham+UC groups showed significant improvements in total and subscale ADHD scores at 4 weeks and 8 weeks. However, there were no significant differences between the two groups. Conclusion: This pilot study demonstrated that it was feasible to examine the effects of chiropractic adjustment when added to usual care on ADHD outcomes in children. While both groups showed improvements, the lack of significant between-group differences requires caution in interpretation due to the small sample size. Further research with larger samples and longer follow-up periods is needed to conclusively evaluate the effects of chiropractic adjustments on ADHD in children.

16.
Am J Stem Cells ; 13(1): 27-36, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38505823

RESUMO

OBJECTIVE: In regenerative biology, the most commonly used cells are adipose tissue-derived mesenchymal stem cells (AD-MSCs). This is due to the abundance and easy accessibility of AD-MSCs. METHODS: In this study, canine AD-MSCs were harvested from different anatomical locations, i.e., subcutaneous (SC), omental (OM), and perirenal (PR). Various isolation techniques namely explants (TRT-I), collagenase-digestion (TRT-II), collagenase-digested explants (TRT-III), and trypsin-digested explants (TRT-IV) were used to segregate the MSCs to evaluate cell doubling time, viability, and adipogenic/osteogenic lineage differentiation potential. RESULTS: The study showed that the SC stem cells had superior growth kinetics compared to other tissues, while the cells isolated through TRT-II performed better than the other cell isolation procedures. The metabolic status of cells isolated from dog adipose tissue indicated that all cells had adequate metabolic rates. However, SC-MSCs derived from TRT-III and TRT-IV outperformed those derived from TRT-I and TRT-II. The differentiation analysis revealed that cells differentiate into adipogenic and osteogenic lineage regardless of treatment, as demonstrated by positive oil red O (ORO) and Alizarin Red S (ALZ) stain. It is worth mentioning that cells derived from TRT-III had larger and more intracellular droplets compared to the other treatments. The TRT-I, -II, and -III showed greater osteogenic differentiation in cells isolated from PR and OM regions compared to SC-derived cells. However, the TRT-IV resulted in better osteogenic differentiation in cells from SC, followed by the OM and PR-derived cells. CONCLUSION: It is concluded that all methods of MSCs isolation from adipose tissues are successful; however, the TRT-II had the highest rate of cell re-assortment from the SC, while, TRT-II and -IV are most suitable for isolating cells from PR and OM adipose tissue.

17.
Sports Med ; 53(11): 2257-2266, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37209367

RESUMO

BACKGROUND: Players in contact sports frequently experience mild traumatic brain (concussion) injuries (TBI). While there are known disruptions to balance following acute head trauma, it is uncertain if sport-related concussion injuries have a lasting impact on postural control. AIM: To assess postural control in retired rugby players in comparison to retired non-contact sport players, and to evaluate any association with self-reported sport-related concussion history. METHODS: Using a cross-sectional design, 75 players in the NZ-RugbyHealth study from three sports groups (44 ± 8 years; 24 elite rugby, 30 community rugby, 21 non-contact sport) took part in this study. The SMART EquiTest® Balance Master was used to assess participant's ability to make effective use of visual, vestibular and proprioceptive information using standardised tests. Postural sway was also quantified using centre of pressure (COP) path length. The relationship among sports group, sport-related concussion history and postural control was evaluated using mixed regression models while controlling for age and body mass index. RESULTS: Limited significant differences in balance metrics were found between the sports groups. A statistically significant (p < 0.001) interaction indicated a relationship between COP path length and sport-related concussion history in the most challenging balance condition, such that path length increased as the number of previous sport-related concussions increased. CONCLUSION: There was some evidence for a relationship between sport-related concussion recurrence in sports players and postural stability in challenging balance conditions. There was no evidence of impaired balance ability in retired rugby players compared with non-contact sport athletes.

18.
Behav Sci (Basel) ; 13(12)2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38131851

RESUMO

Haptic nudging via wearable devices promotes physical activity and may increase upper limb movement in stroke rehabilitation. This study investigated the optimal approach to haptic nudging by examining diurnal variation, duration of effect, and repeated nudging. The study analysed data from a multiple-period randomised crossover study. A 12 h inpatient rehabilitation day was divided into 72 intervals in which participants with stroke (n = 20) randomly received either a 'nudge' or 'no nudge'. Upper limb movement was observed, classified, and analysed using longitudinal mixed models. The odds of affected upper limb movement following a nudge compared with no nudge were significantly higher during active periods such as breakfast, lunch, and morning and afternoon activities (odds ratios (ORs) 2.01-4.63, 95% CIs [1.27-2.67, 3.17-8.01]), but not dinner (OR 1.36, 95% CI [0.86, 2.16]). The effect of nudging was no longer statistically significant at 50-60 s post-nudge. Consecutive delays in nudging significantly decreased the odds of moving when a nudge was eventually delivered. Contrary to expectations, people with stroke appear more responsive to haptic nudging during active periods rather than periods of inactivity. By understanding the optimal timing and frequency of haptic nudging, the design of wearable devices can be optimised to maximise their therapeutic benefits.

19.
Animals (Basel) ; 13(16)2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37627446

RESUMO

The use of fetal bovine serum (FBS) in regenerative medicine raises serious ethical and scientific concerns. We have cultured and differentiated the canine mesenchymal stem cells (cMSCs) in five different media combinations of autologous platelet lysate (A-PL) and FBS; consisting of 0% A-PL and 10% FBS (M-1), 2.5% A-PL and 7.5% FBS (M-2), 5% A-PL and 5% FBS (M-3), 7.5% A-PL and 2.5% FBS (M-4), and 10% A-PL and 0% FBS (M-5). The cMSCs were evaluated for their doubling time, differentiation efficiency, and expression of CD73, CD90, CD105, and PDGFRα. The mRNA expression of NT5E, THY1, ENG, PPARγ, FABP4, FAS, SP7, BGLAP, and SPP1 was also assessed. The results indicated non-significant differences in cellular proliferation/viability; positive expression of surface markers, and PDGFRα with substantial adipo/osteogenic differentiation. The expression of adipogenic (PPARγ, FABP4, FAS), and osteogenic (SP7, BGLAP, SPP1) genes were higher (p < 0.05) in the M5 group. In conclusion, A-PL in cMSCs culture did not negatively affect cellular proliferation and viability but also enhanced their genetic potential for multilineage differentiation. Our results indicate that A-PL can be used as an alternative for FBS to develop potent cMSCs under good manufacturing practice protocol for regenerative medicine.

20.
JMIR Rehabil Assist Technol ; 10: e49702, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38079202

RESUMO

BACKGROUND: Rehabilitation technologies for people with stroke are rapidly evolving. These technologies have the potential to support higher volumes of rehabilitation to improve outcomes for people with stroke. Despite growing evidence of their efficacy, there is a lack of uptake and sustained use in stroke rehabilitation and a call for user-centered design approaches during technology design and development. This study focuses on a novel rehabilitation technology called exciteBCI, a complex neuromodulatory wearable technology in the prototype stage that augments locomotor rehabilitation for people with stroke. The exciteBCI consists of a brain computer interface, a muscle electrical stimulator, and a mobile app. OBJECTIVE: This study presents the evaluation phase of an iterative user-centered design approach supported by a qualitative descriptive methodology that sought to (1) explore users' perspectives and experiences of exciteBCI and how well it fits with rehabilitation, and (2) facilitate modifications to exciteBCI design features. METHODS: The iterative usability evaluation of exciteBCI was conducted in 2 phases. Phase 1 consisted of 3 sprint cycles consisting of single usability sessions with people with stroke (n=4) and physiotherapists (n=4). During their interactions with exciteBCI, participants used a "think-aloud" approach, followed by a semistructured interview. At the end of each sprint cycle, device requirements were gathered and the device was modified in preparation for the next cycle. Phase 2 focused on a "near-live" approach in which 2 people with stroke and 1 physiotherapist participated in a 3-week program of rehabilitation augmented by exciteBCI (n=3). Participants completed a semistructured interview at the end of the program. Data were analyzed from both phases using conventional content analysis. RESULTS: Overall, participants perceived and experienced exciteBCI positively, while providing guidance for iterative changes. Five interrelated themes were identified from the data: (1) "This is rehab" illustrated that participants viewed exciteBCI as having a good fit with rehabilitation practice; (2) "Getting the most out of rehab" highlighted that exciteBCI was perceived as a means to enhance rehabilitation through increased engagement and challenge; (3) "It is a tool not a therapist," revealed views that the technology could either enhance or disrupt the therapeutic relationship; and (4) "Weighing up the benefits versus the burden" and (5) "Don't make me look different" emphasized important design considerations related to device set-up, use, and social acceptability. CONCLUSIONS: This study offers several important findings that can inform the design and implementation of rehabilitation technologies. These include (1) the design of rehabilitation technology should support the therapeutic relationship between the patient and therapist, (2) social acceptability is a design priority in rehabilitation technology but its importance varies depending on the use context, and (3) there is value in using design research methods that support understanding usability in the context of sustained use.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA