Clin Transplant ; 30(3): 195-201, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26589376

RESUMO

BACKGROUND: Ventricular assist devices (VADs) have a proven survival benefit in select patients with advanced heart failure, yet many patients considered for implantation are declined for various reasons. The outcome of these patients is obscure owing to their exclusion from recent VAD studies. We aim to compare the outcomes of patients who received a VAD to those who did not. METHODS: For this study, the Artificial Heart Program's database at Intermountain Medical Center was queried from 2006 to 2012 for patients referred for a VAD. Kaplan-Meier survival analysis was performed with log-rank test determining significance. RESULTS: Of 232 patients included, 118 patients received a VAD and 114 patients did not. The prevailing reason for VAD decline in eligible and willing patients was due to pre-existing illness (39%). Mortality was higher in non-VAD vs. VAD patients (58.8% vs. 35.6%, p < 0.001) with a median time-to-death of 67 (IQR:12-314) and 301 (IQR:136-694) d, respectively (p = 0.007). CONCLUSIONS: In the current era of non-pulsatile VADs, mortality of patients who are considered but not implanted remains high. Additionally, mortality of these patients occurred much sooner. Educational efforts ensuring timely referral for VAD therapy are important to maximize the number of patients who may benefit.


Assuntos
Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Marca-Passo Artificial/efeitos adversos , Qualidade de Vida , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida , Resultado do Tratamento
2.
Cardiovasc Pathol ; 24(2): 71-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25483742

RESUMO

BACKGROUND: Driveline exit site (DLES) infection is a major complication of ventricular assist devices (VADs). Differences in the sheath material interfacing with exit site tissue appear to affect healing time and infection risk more than site hygiene, but the mechanistic basis for this is not clear. METHODS: Health record data from Utah Artificial Heart Program patients with HeartMate II (HMII) devices implanted from 2008 to 2012 were retrospectively reviewed, with particular attention to interface type, incorporation (healing) time, and infections. Tissue samples from the DLES were collected at the time of VAD removal in a small subset. These samples were examined by routine histology and environmental scanning electron microscopy (ESEM). RESULTS: Among 57 patients with sufficient data, 15 had velour interfaces and 42 had silicone. Indications for and duration of support were similar between the groups. The silicone group had shorter incorporation time (45 ±22 vs. 56 ±34 days, P=.17) and fewer DLES infections (20% vs. 1.7%, P=.026, for patient infections and 0.0340 vs. 0.166, P=.16, for infections per patient-year). Tissues from five patients, three with velour, were examined. Velour interfaces demonstrated more hyperkeratosis, hypergranulosis, and dermal inflammation. By ESEM, the silicone driveline tracts appeared relatively smooth and flat, whereas the velour interface samples were irregular with deep fissures and globular material adhering to the surface. CONCLUSIONS: Using the silicone portion of the HMII driveline at the DLES was associated with fewer infections and a trend toward faster healing in this small retrospective series. Whether the intriguing microscopic differences directly account for this needs further study on a larger scale.


Assuntos
Coração Auxiliar/efeitos adversos , Poliésteres/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Silicones/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/epidemiologia
3.
ASAIO J ; 56(1): 1-5, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20019597

RESUMO

Patients increasingly require longer durations of left ventricular assist device (LVAD) therapy. Despite a recent trend toward continuous flow VADs, the HeartMate XVE is still commonly used, but its longevity remains a significant limitation. Existing surveillance methods of pump failure often give inconclusive results. XVE electrical current waveforms were collected regularly (2001-2008) and sorted into quartiles according to number of days until pump failure (Q1, 0-34; Q2, 34-160; Q3, 160-300; and Q4, 300-390 days). Thoratec waveform files were converted into text files. The 10-second electrical current, voltage waveform was identified and isolated for analysis. Waveforms were analyzed by principal component analysis (PCA) and with a fast Fourier transform. Quartiles were compared with analysis of variance (ANOVA). Waveforms (n = 454) were collected for 21 patients with failed pumps. An artificial neural network was used to predict pump failure within 30 days from the waveform characteristics identified though signal processing.


Assuntos
Análise de Falha de Equipamento/métodos , Coração Auxiliar , Redes Neurais de Computação , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Componente Principal
4.
J Am Coll Cardiol ; 56(5): 382-91, 2010 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-20650360

RESUMO

OBJECTIVES: This study investigates alterations in myocardial microvasculature, fibrosis, and hypertrophy before and after mechanical unloading of the failing human heart. BACKGROUND: Recent studies demonstrated the pathophysiologic importance and significant mechanistic links among microvasculature, fibrosis, and hypertrophy during the cardiac remodeling process. The effect of left ventricular assist device (LVAD) unloading on cardiac endothelium and microvasculature is unknown, and its influence on fibrosis and hypertrophy regression to the point of atrophy is controversial. METHODS: Hemodynamic data and left ventricular tissue were collected from patients with chronic heart failure at LVAD implant and explant (n = 15) and from normal donors (n = 8). New advances in digital microscopy provided a unique opportunity for comprehensive whole-field, endocardium-to-epicardium evaluation for microvascular density, fibrosis, cardiomyocyte size, and glycogen content. Ultrastructural assessment was done with electron microscopy. RESULTS: Hemodynamic data revealed significant pressure unloading with LVAD. This was accompanied by a 33% increase in microvascular density (p = 0.001) and a 36% decrease in microvascular lumen area (p = 0.028). We also identified, in agreement with these findings, ultrastructural and immunohistochemical evidence of endothelial cell activation. In addition, LVAD unloading significantly increased interstitial and total collagen content without any associated structural, ultrastructural, or metabolic cardiomyocyte changes suggestive of hypertrophy regression to the point of atrophy and degeneration. CONCLUSIONS: The LVAD unloading resulted in increased microvascular density accompanied by increased fibrosis and no evidence of cardiomyocyte atrophy. These new insights into the effects of LVAD unloading on microvasculature and associated key remodeling features might guide future studies of unloading-induced reverse remodeling of the failing human heart.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Microcirculação , Adolescente , Adulto , Cardiologia/métodos , Cardiomegalia/patologia , Endotélio/patologia , Feminino , Ventrículos do Coração/patologia , Humanos , Hipertrofia , Masculino , Microscopia Eletrônica/métodos , Pessoa de Meia-Idade , Miocárdio/patologia , Estresse Mecânico , Remodelação Ventricular
5.
Am J Cardiol ; 103(5): 709-12, 2009 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-19231338

RESUMO

An increasing number of patients are living with ventricular assist devices (VADs). Many of these patients will require noncardiac surgery for conditions not directly related to their VADs. The aim of this study was to assess the risks and outcomes of noncardiac surgery in these patients. Perioperative and follow-up data from patients with VADs who underwent noncardiac surgery from 1993 to 2006 were analyzed. In that period, 184 VADs were implanted in 155 patients. Thirty-seven patients (24%) subsequently underwent 59 noncardiac surgeries. The mean duration of VAD support before surgery was 229 days. Bleeding was the most common postsurgical complication (10%), necessitating reexploration in 20% of abdominal surgeries. Thirty-day mortality was 12%. No deaths were caused by direct complications of surgery. Successful transplantation occurred in 72% of bridge to transplantation patients who required noncardiac surgery, compared with 71% of these patients who did not require noncardiac surgery (relative risk 1.0, p = 0.9). The average duration of VAD support after noncardiac surgery for destination therapy patients was 324 days, most of which time was spent at home. In conclusion, outcomes after noncardiac surgery in patients with VADs are favorable, and most patients continue to benefit from the intended purpose of mechanical circulatory support after recovering from noncardiac surgery.


Assuntos
Coração Auxiliar , Procedimentos Cirúrgicos Operatórios , Feminino , Transplante de Coração , Coração Auxiliar/efeitos adversos , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Cuidados Pré-Operatórios , Procedimentos Cirúrgicos Operatórios/mortalidade , Resultado do Tratamento
6.
J Thorac Cardiovasc Surg ; 135(6): 1353-60; discussion 1360-1, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18544385

RESUMO

OBJECTIVE: Destination therapy experience using long-term left ventricular assist devices was analyzed relative to the benchmark Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure trial to evaluate the potential for improving outcomes with this groundbreaking therapy for advanced heart failure. METHODS: The largest single-center experience with destination therapy in the United States (Utah Artificial Heart Program, LDS Hospital, Salt Lake City, UT) was retrospectively analyzed. All destination therapy recipients (n = 23) presented with chronic, advanced heart failure, meeting indications for destination therapy adopted from the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure trial. All received HeartMate left ventricular assist devices (Thoratec Corp, Pleasanton, Calif), with 87% receiving an improved XVE model. Advanced practice guidelines were implemented using a multidisciplinary approach. Survivals (Kaplan-Meier, log-rank analyses) and adverse events (Poisson regression) were compared with those of the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure left ventricular assist device group (n = 68). RESULTS: Survival in the destination therapy group was significantly increased (P = .007), with an overall reduction in mortality of 66%. The 2-year survival was 77% for destination therapy compared with 29% for the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure left ventricular assist device group (P < .0001). The 1-year survival was 77% for destination therapy compared with the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure left ventricular assist device rate of 52% (P = .036). Adverse events decreased by 38% (3.90 per patient-year in the destination therapy group compared with the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure left ventricular assist device rate of 6.32). Factors related to severity of illness met Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure-like criteria for both groups. CONCLUSIONS: This analysis provides evidence that long-term destination therapy can be improved well beyond the pioneering experience of the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure trial. With continued evolution of devices, management, and patient selection, outcomes approaching those of heart transplantation may be possible.


Assuntos
Fármacos Cardiovasculares/uso terapêutico , Causas de Morte , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Benchmarking , Estudos de Avaliação como Assunto , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Distribuição de Poisson , Probabilidade , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA