1.
Support Care Cancer ; 30(10): 8377-8389, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35513755

RESUMO

INTRODUCTION: Despite reduction of xerostomia with intensity-modulated compared to conformal X-ray radiotherapy, radiation-induced dental complications continue to occur. Proton therapy is promising in head and neck cancers to further reduce radiation-induced side-effects, but the optimal dental management has not been defined. MATERIAL AND METHODS: Dental management before proton therapy was assessed compared to intensity-modulated radiotherapy based on a bicentric experience, a literature review and illustrative cases. RESULTS: Preserved teeth frequently contain metallic dental restorations (amalgams, crowns, implants). Metals blur CT images, introducing errors in tumour and organ contour during radiotherapy planning. Due to their physical interactions with matter, protons are more sensitive than photons to tissue composition. The composition of restorative materials is rarely documented during radiotherapy planning, introducing dose errors. Manual artefact recontouring, metal artefact-reduction CT algorithms, dual or multi-energy CT and appropriate dose calculation algorithms insufficiently compensate for contour and dose errors during proton therapy. Physical uncertainties may be associated with lower tumour control probability and more side-effects after proton therapy. Metal-induced errors should be quantified and removal of metal restorations discussed on a case by case basis between dental care specialists, radiation oncologists and physicists. Metallic amalgams can be replaced with water-equivalent materials and crowns temporarily removed depending on rehabilitation potential, dental condition and cost. Implants might contraindicate proton therapy if they are in the proton beam path. CONCLUSION: Metallic restorations may more severely affect proton than photon radiotherapy quality. Personalized dental care prior to proton therapy requires multidisciplinary assessment of metal-induced errors before choice of conservation/removal of dental metals and optimal radiotherapy.


Assuntos
Assistência Odontológica , Neoplasias de Cabeça e Pescoço , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Metais , Terapia com Prótons/efeitos adversos , Lesões por Radiação , Radioterapia de Intensidade Modulada/efeitos adversos , Água
2.
J Appl Clin Med Phys ; 17(2): 473-486, 2016 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-27074467

RESUMO

The purpose of this study was to evaluate the accuracy and clinical feasibility of a motion monitoring method employing simultaneously acquired MV and kV images during volumetric-modulated arc therapy (VMAT). Short-arc digital tomosynthesis (SA-DTS) is used to improve the quality of the MV images that are then combined with orthogonally acquired kV images to assess 3D motion. An anthropomorphic phantom with implanted gold seeds was used to assess accuracy of the method under static, typical prostatic, and respiratory motion scenarios. Automatic registra-tion of kV images and single MV frames or MV SA-DTS reconstructed with arc lengths from 2° to 7° with the appropriate reference fiducial template images was performed using special purpose-built software. Clinical feasibility was evaluated by retrospectively analyzing images acquired over four or five sessions for each of three patients undergoing hypofractionated prostate radiotherapy. The standard deviation of the registration error in phantom using MV SA-DTS was similar to single MV images for the static and prostate motion scenarios (σ = 0.25 mm). Under respiratory motion conditions, the standard deviation of the registration error increased to 0.7mm and 1.7 mm for single MV and MV SA-DTS, respectively. Registration failures were observed with the respiratory scenario only and were due to motion-induced fiducial blurring. For the three patients studied, the mean and standard deviation of the difference between automatic registration using 4° MV SA-DTS and manual registration using single MV images results was 0.07±0.52mm. The MV SA-DTS results in patients were, on average, superior to single-frame MV by nearly 1 mm - significantly more than what was observed in phantom. The best MV SA-DTS results were observed with arc lengths of 3° to 4°. Registration failures in patients using MV SA-DTS were primarily due to blockage of the gold seeds by the MLC. The failure rate varied from 2% to 16%. Combined MV SA-DTS and kV imaging is feasible for intratreatment motion monitoring during VMAT of anatomic sites where limited motion is expected, and improves registration accuracy compared to single MV/kV frames. To create a clinically robust technique, further improvements to ensure visualization of fiducials at the desired control points without degradation of the treatment plan are needed.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Movimento (Física) , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos de Viabilidade , Marcadores Fiduciais , Humanos , Masculino , Imagem Molecular/métodos , Dosagem Radioterapêutica , Estudos Retrospectivos , Software
3.
Phys Med ; 107: 102551, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36867911

RESUMO

PURPOSE: An ocular applicator that fits a commercial proton snout with an upstream range shifter to allow for treatments with sharp lateral penumbra is described. MATERIALS AND METHODS: The validation of the ocular applicator consisted of a comparison of range, depth doses (Bragg peaks and spread out Bragg peaks), point doses, and 2-D lateral profiles. Measurements were made for three field sizes, 1.5, 2, and 3 cm, resulting in 15 beams. Distal and lateral penumbras were simulated in the treatment planning system for seven range-modulation combinations for beams typical of ocular treatments and a field size of 1.5 cm, and penumbra values were compared to published literature. RESULTS: All the range errors were within 0.5 mm. The maximum averaged local dose differences for Bragg peaks and SOBPs were 2.6% and 1.1%, respectively. All the 30 measured point doses were within +/-3% of the calculated. The measured lateral profiles, analyzed through gamma index analysis and compared to the simulated, had pass rates greater than 96% for all the planes. The lateral penumbra increased linearly with depth, from 1.4 mm at 1 cm depth to 2.5 mm at 4 cm depth. The distal penumbra ranged from 3.6 to 4.4 mm and increased linearly with the range. The treatment time for a single 10 Gy (RBE) fractional dose ranged from 30 to 120 s, depending on the shape and size of the target. CONCLUSIONS: The ocular applicator's modified design allows lateral penumbra similar to dedicated ocular beamlines while enabling planners to use modern treatment tools such as Monte Carlo and full CT-based planning with increased flexibility in beam placement.


Assuntos
Terapia com Prótons , Prótons , Terapia com Prótons/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica , Síncrotrons , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos
4.
Sci Rep ; 12(1): 4648, 2022 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-35301371

RESUMO

Treatment of ocular tumors on dedicated scattering-based proton therapy systems is standard afforded due to sharp lateral and distal penumbras. However, most newer proton therapy centers provide pencil beam scanning treatments. In this paper, we present a pencil beam scanning (PBS)-based ocular treatment solution. The design, commissioning, and validation of an applicator mount for a conventional PBS snout to allow for ocular treatments are given. In contrast to scattering techniques, PBS-based ocular therapy allows for inverse planning, providing planners with additional flexibility to shape the radiation field, potentially sparing healthy tissues. PBS enables the use of commercial Monte Carlo algorithms resulting in accurate dose calculations in the presence of heterogeneities and fiducials. The validation consisted of small field dosimetry measurements of point doses, depth doses, and lateral profiles relevant to ocular therapy. A comparison of beam properties achieved through the applicator against published literature is presented. We successfully showed the feasibility of PBS-based ocular treatments.


Assuntos
Neoplasias Oculares , Terapia com Prótons , Algoritmos , Neoplasias Oculares/radioterapia , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Terapia com Prótons/métodos , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
5.
Phys Med ; 78: 179-186, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33038643

RESUMO

PURPOSE: This study aims to investigate the use of machine learning models for delivery error prediction in proton pencil beam scanning (PBS) delivery. METHODS: A dataset of planned and delivered PBS spot parameters was generated from a set of 20 prostate patient treatments. Planned spot parameters (spot position, MU and energy) were extracted from the treatment planning system (TPS) for each beam. Delivered spot parameters were extracted from irradiation log-files for each beam delivery following treatment. The dataset was used as a training dataset for three machine learning models which were trained to predict delivered spot parameters based on planned parameters. K-fold cross validation was employed for hyper-parameter tuning and model selection where the mean absolute error (MAE) was used as the model evaluation metric. The model with lowest MAE was then selected to generate a predicted dose distribution for a test prostate patient within a commercial TPS. RESULTS: Analysis of the spot position delivery error between planned and delivered values resulted in standard deviations of 0.39 mm and 0.44 mm for x and y spot positions respectively. Prediction error standard deviation values of spot positions using the selected model were 0.22 mm and 0.11 mm for x and y spot positions respectively. Finally, a three-way comparison of dose distributions and DVH values for select OARs indicates that the random-forest-predicted dose distribution within the test prostate patient was in closer agreement to the delivered dose distribution than the planned distribution. CONCLUSIONS: PBS delivery error can be accurately predicted using machine learning techniques.


Assuntos
Terapia com Prótons , Prótons , Humanos , Aprendizado de Máquina , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
6.
Phys Med ; 80: 175-185, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33189048

RESUMO

PURPOSE: This work aims to validate new 6D couch features and their implementation for seated radiotherapy in RayStation (RS) treatment planning system (TPS). MATERIALS AND METHODS: In RS TPS, new 6D couch features are (i) chair support device, (ii) patient treatment option of "Sitting: face towards the front of the chair", and (iii) patient support pitch and roll capabilities. The validation of pitch and roll was performed by comparing TPS generated DRRs with planar x-rays. Dosimetric tests through measurement by 2D ion chamber array were performed for beams created with varied scanning and treatment orientation and 6D couch rotations. For the implementation of 6D couch features for treatments in a seated position, the TPS and oncology information system (Mosaiq) settings are described for a commercial chair. An end-to-end test using an anthropomorphic phantom was performed to test the complete workflow from simulation to treatment delivery. RESULTS: The 6D couch features were found to have a consistent implementation that met IEC 61712 standard. The DRRs were found to have an acceptable agreement with planar x-rays based on visual inspection. For dose map comparison between measured and calculated, the gamma index analysis for all the beams was >95% at a 3% dose-difference and 3 mm distance-to-agreement tolerances. For an end-to end-testing, the phantom was successfully set up at isocenter in the seated position and treatment was delivered. CONCLUSIONS: Chair-based treatments in a seated position can be implemented in RayStation through the use of newly released 6D couch features.


Assuntos
Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Postura Sentada
7.
Transl Lung Cancer Res ; 7(2): 171-179, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29876316

RESUMO

The accuracy of dose calculation is vital to the quality of care for patients undergoing proton beam therapy (PBT). Currently, the dose calculation algorithms available in commercial treatment planning systems (TPS) in PBT are classified into two classes: pencil beam (PB) and Monte-Carlo (MC) algorithms. PB algorithms are still regarded as the standard of practice in PBT, but they are analytical approximations whereas MC algorithms use random sampling of interaction cross-sections that represent the underlying physics to simulate individual particles trajectories. This article provides a brief review of PB and MC dose calculation algorithms employed in commercial treatment planning systems and their performance comparison in phantoms through simulations and measurements. Deficiencies of PB algorithms are first highlighted by a simplified simulation demonstrating the transport of a single sub-spot of proton beam that is incident at an oblique angle in a water phantom. Next, more typical cases of clinical beams in water phantom are presented and compared to measurements. The inability of PB to correctly predict the range and subsequently distal fall-off is emphasized. Through the presented examples, it is shown how dose errors as high as 30% can result with use of a PB algorithm. These dose errors can be minimized to clinically acceptable levels of less than 5%, if MC algorithm is employed in TPS. As a final illustration, comparison between PB and MC algorithm is made for a clinical beam that is use to deliver uniform dose to a target in a lung section of an anthropomorphic phantom. It is shown that MC algorithm is able to correctly predict the dose at all depths and matched with measurements. For PB algorithm, there is an increasing mismatch with the measured doses with increasing tissue heterogeneity. The findings of this article provide a foundation for the second article of this series to compare MC vs. PB based lung cancer treatment planning.

8.
Magn Reson Imaging ; 33(6): 829-39, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25490517

RESUMO

PURPOSE: The purpose of this work is to develop a method for accurately quantifying effective magnetic moments of spherical-like small objects from magnetic resonance imaging (MRI). A standard 3D gradient echo sequence with only one echo time is intended for our approach to measure the effective magnetic moment of a given object of interest. METHODS: Our method sums over complex MR signals around the object and equates those sums to equations derived from the magnetostatic theory. With those equations, our method is able to determine the center of the object with subpixel precision. By rewriting those equations, the effective magnetic moment of the object becomes the only unknown to be solved. Each quantified effective magnetic moment has an uncertainty that is derived from the error propagation method. If the volume of the object can be measured from spin echo images, the susceptibility difference between the object and its surrounding can be further quantified from the effective magnetic moment. Numerical simulations, a variety of glass beads in phantom studies with different MR imaging parameters from a 1.5T machine, and measurements from a SQUID (superconducting quantum interference device) based magnetometer have been conducted to test the robustness of our method. RESULTS: Quantified effective magnetic moments and susceptibility differences from different imaging parameters and methods all agree with each other within two standard deviations of estimated uncertainties. CONCLUSION: An MRI method is developed to accurately quantify the effective magnetic moment of a given small object of interest. Most results are accurate within 10% of true values, and roughly half of the total results are accurate within 5% of true values using very reasonable imaging parameters. Our method is minimally affected by the partial volume, dephasing, and phase aliasing effects. Our next goal is to apply this method to in vivo studies.


Assuntos
Imageamento por Ressonância Magnética/estatística & dados numéricos , Algoritmos , Simulação por Computador , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Magnetismo , Imagens de Fantasmas , Reprodutibilidade dos Testes , Incerteza
9.
Med Phys ; 42(6): 2813-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26127033

RESUMO

PURPOSE: To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate. METHODS: Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min. Each patient had at least one implanted fiducial marker near the tumor. In all scans, abdominal displacement (Varian RPM) was recorded as the external motion signal. Purpose-built software tracked fiducials, representing internal signal, in CBCT projection images. Time lag between superior-inferior (SI) internal and anterior-posterior external signals was found by maximizing the correlation coefficient in each breathing cycle and averaging over all cycles. Time-lag-induced discrepancy between internal SI position and that predicted from the external signal (external prediction error) was also calculated. RESULTS: Mean ± standard deviation time lag, over all scans and patients, was 0.10 ± 0.07 s (range 0.01-0.36 s). External signal lagged the internal in 17/18 scans. Change in time lag between pre- and post-treatment CBCT was 0.06 ± 0.07 s (range 0.01-0.22 s), corresponding to 3.1% ± 3.7% (range 0.6%-10.8%) of gate width (range 1.6-3.1 s). In only one patient, change in time lag exceeded 10% of the gate width. External prediction error over all scans of all patients varied from 0.1 ± 0.1 to 1.6 ± 0.4 mm. CONCLUSIONS: Time lag between internal motion along SI and external signals is small compared to the treatment gate width of abdominal patients examined in this study. Change in time lag within a treatment session, inferred from pre- to post-treatment measurements is also small, suggesting that a single measurement of time lag at the session start is adequate. These findings require confirmation in a larger number of patients.


Assuntos
Fracionamento da Dose de Radiação , Neoplasias Gastrointestinais/fisiopatologia , Neoplasias Gastrointestinais/radioterapia , Movimento , Neoplasias Pancreáticas/fisiopatologia , Neoplasias Pancreáticas/radioterapia , Tomografia Computadorizada de Feixe Cônico , Marcadores Fiduciais , Neoplasias Gastrointestinais/diagnóstico por imagem , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador , Fatores de Tempo
10.
ACS Nano ; 8(7): 6814-21, 2014 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-24893115

RESUMO

Small changes in the synthesis of MnAs nanoparticles lead to materials with distinct behavior. Samples prepared by slow heating to 523 K (type-A) exhibit the characteristic magnetostructural transition from the ferromagnetic hexagonal (α) to the paramagnetic orthorhombic (ß) phase of bulk MnAs at Tp = 312 K, whereas those prepared by rapid nucleation at 603 K (type-B) adopt the ß structure at room temperature and exhibit anomalous magnetic properties. The behavior of type-B nanoparticles is due to P-incorporation (up to 3%), attributed to reaction of the solvent (trioctylphosphine oxide). P-incorporation results in a decrease in the unit cell volume (∼1%) and shifts Tp below room temperature. Temperature-dependent X-ray diffraction reveals a large region of phase-coexistence, up to 90 K, which may reflect small differences in Tp from particle-to-particle within the nearly monodisperse sample. The large coexistence range coupled to the thermal hysteresis results in process-dependent phase mixtures. As-prepared type-B samples exhibiting the ß structure at room temperature convert to a mixture of α and ß after the sample has been cooled to 77 K and rewarmed to room temperature. This change is reflected in the magnetic response, which shows an increased moment and a shift in the temperature hysteresis loop after cooling. The proportion of α present at room temperature can also be augmented by application of an external magnetic field. Both doped (type-B) and undoped (type-A) MnAs nanoparticles show significant thermal hysteresis narrowing relative to their bulk phases, suggesting that formation of nanoparticles may be an effective method to reduce thermal losses in magnetic refrigeration applications.

11.
Med Phys ; 41(7): 071906, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24989384

RESUMO

PURPOSE: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. METHODS: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. The kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. RESULTS: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%-100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%-100%), and 94.3% (range 93%-97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. CONCLUSIONS: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Marcadores Fiduciais , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Suspensão da Respiração , Simulação por Computador , Neoplasias Esofágicas/diagnóstico por imagem , Junção Esofagogástrica/diagnóstico por imagem , Estudos de Viabilidade , Ouro , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Modelos Biológicos , Movimento (Física) , Neoplasias Pancreáticas/diagnóstico por imagem , Imagens de Fantasmas , Rotação , Software , Neoplasias Gástricas/diagnóstico por imagem
12.
Med Phys ; 40(5): 051719, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23635267

RESUMO

PURPOSE: Real-time tracking of respiratory target motion during radiation therapy is technically challenging, owing to rapid and possibly irregular breathing variations. The authors report on a method to predict and correct respiration-averaged drift in target position by means of couch adjustments on an accelerator equipped with such capability. METHODS: Dose delivery is broken up into a sequence of 10 s field segments, each followed by a couch adjustment based on analysis of breathing motion from an external monitor as a surrogate of internal target motion. Signal averaging over three respiratory cycles yields a baseline representing target drift. A Kalman filter predicts the baseline position 5 s in advance, for determination of the couch correction. The method's feasibility is tested with a motion phantom programmed according to previously recorded patient signals. Computed couch corrections are preprogrammed into a research mode of an accelerator capable of computer-controlled couch translations synchronized with the motion phantom. The method's performance is evaluated with five cases recorded during hypofractionated treatment and five from respiration-correlated CT simulation, using a root-mean-squared deviation (RMSD) of the baseline from the treatment planned position. RESULTS: RMSD is reduced in all 10 cases, from a mean of 4.9 mm (range 2.7-9.4 mm) before correction to 1.7 mm (range 0.7-2.3 mm) after correction. Treatment time is increased ∼5% relative to that for no corrections. CONCLUSIONS: This work illustrates the potential for reduction in baseline respiratory drift with periodic adjustments in couch position during treatment. Future treatment machine capabilities will enable the use of "on-the-fly" couch adjustments during treatment.


Assuntos
Movimento , Radioterapia Assistida por Computador/métodos , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica