Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Dig Dis Sci ; 63(9): 2445-2450, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29779082

RESUMO

BACKGROUND: Patients with ulcerative colitis (UC) are at an increased risk of Clostridium difficile infection (CDI) compared with the general population. Recent data suggest that obesity also increases the risk of CDI. AIMS: To examine whether obesity influences the risk of CDI among patients with UC. STUDY: We conducted a retrospective cross-sectional study of UC patients seen in gastroenterology clinic between January 1, 2014, and December 31, 2015. Records were reviewed for patients with the diagnosis of UC prior to 2014, and the first diagnosis of CDI between January 1, 2014, and December 31, 2015. Using body mass index (BMI), patients were classified into underweight (BMI < 18.5), normal weight (18.5 ≤ BMI < 25), overweight (25 ≤ BMI < 30), and obese (BMI ≥ 30). Age-adjusted and multivariate logistic regression was performed including gender, tobacco use, UC disease duration, medication exposure, and vitamin D deficiency. RESULTS: Of the 636 patients with UC, 114 (18%) were obese, 232 (36%) overweight, 274 (43%) normal weight, and 16 (2.5%) underweight. Nineteen patients (3.0%) developed CDI during the study period. CDI risk was not associated with BMI (OR 0.90, 95% CI 0.79-1.02). Compared to normal weight patients, risk of CDI was not influenced by being obese (multivariate OR 0.63, 95% CI 0.15-2.58), overweight (multivariate OR 0.33, 95% CI 0.08-1.30), or underweight (multivariate OR 2.98, 95% CI 0.45-19.83). CDI was associated with ever use of TNF therapy (multivariate OR 6.09, 95% CI 2.07-17.93) but not vedolizumab (multivariate OR 0.76, 95% CI 0.08-7.36). CONCLUSIONS: Obesity does not appear to be associated with the risk of C. difficile infection among patients with UC.


Assuntos
Infecções por Clostridium/epidemiologia , Colite Ulcerativa/epidemiologia , Obesidade/epidemiologia , Adulto , Idoso , Índice de Massa Corporal , Distribuição de Qui-Quadrado , Infecções por Clostridium/diagnóstico , Infecções por Clostridium/microbiologia , Colite Ulcerativa/diagnóstico , Colite Ulcerativa/tratamento farmacológico , Colite Ulcerativa/microbiologia , Estudos Transversais , Disbiose , Feminino , Fármacos Gastrointestinais/efeitos adversos , Microbioma Gastrointestinal , Trato Gastrointestinal/microbiologia , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Obesidade/diagnóstico , Obesidade/microbiologia , Razão de Chances , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
2.
Gastrointest Endosc ; 78(2): 325-32, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23664161

RESUMO

BACKGROUND: MiroCam, a capsule endoscope, uses a novel transmission technology, electric-field propagation, which uses the human body as a conduction medium for data transmission. OBJECTIVE: To compare the ability of the MiroCam (MC) and PillCam (PC) to identify sources of obscure GI bleeding (OGIB). DESIGN: Prospective, multicenter, comparative study. SETTING: Six academic hospitals. PATIENTS: A total of 105 patients with OGIB. INTERVENTION: Patients ingested both the MC and PC capsules sequentially in a randomized fashion. MAIN OUTCOME MEASUREMENTS: Concordance of rates in identifying a source of OGIB, operational times, and rates of complete small-bowel examination. RESULTS: Data analysis resulted in 43 (48%) "abnormal" cases identifying a source of OGIB by either capsule. Twenty-four cases (55.8%) were positive by both capsules. There was negative agreement in 46 of 58 cases (79.3%). The κ index was 0.547 (χ(2) = 1.32; P = .36). In 12 cases, MC positively identified a source that was not seen on PC, whereas in 7 cases, PC positively identified a source that was not seen on MC. MC had a 5.6% higher rate of detecting small-bowel lesions (P = .54). MC captured images at 3 frames per second for 11.1 hours, and PC captured images at 2 frames per second for 7.8 hours (P < .0001). Complete small-bowel examination was achieved in 93.3% for MC and 84.3% for PC (P = .10). LIMITATIONS: Readers were not blinded to the particular capsule they were reading. CONCLUSION: A positive diagnostic finding for OGIB was identified by either capsule in 48% of cases. The concordance rate between the 2 capsules was comparable to that of prior studies in identifying sources of small-bowel bleeding. The longer operational time of the MC may result in higher rates of complete small-bowel examination, which may, in turn, translate into a higher rate of detecting small-bowel lesions. ( CLINICAL TRIAL REGISTRATION NUMBER: NCT00878982.).


Assuntos
Cápsulas Endoscópicas , Endoscopia por Cápsula/métodos , Hemorragia Gastrointestinal/diagnóstico , Intestino Delgado/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA