Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
IUBMB Life ; 72(8): 1686-1697, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32311821

RESUMO

microRNA-3607 (miR-3607) has been identified as an important biomarker, and its aberrant expression exerts a significant role in tumorigenesis. However, the biological function of miR-3607 in hepatocellular carcinoma (HCC) needs to be deciphered comprehensively. Clinical samples of HCC patients, as well as normal cases, were derived from The Cancer Genome Atlas database. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) and Western blotting analyses were utilized to detect the expression levels of indicated genes. Cell counting kit-8 (CCK-8), colony formation, and transwell assays were performed to assess the effect of miR-3607 in HCC cell viability, migration, and invasion. Bioinformatics analysis and luciferase reporter gene assay was applied to screen the target genes of miR-3607 and verified the association between miR-3607 and its potential target gene. Our study showed that miR-3607 expression was decreased in HCC tissues and cell lines, and its downregulation was linked with poor outcomes of HCC patients. miR-3607 was noted to inhibit HCC cell growth, colony formation, migration, and invasion. Besides, minichromosome maintenance (MCM5) was a possible target gene of miR-3607 in HCC. Overexpression of MCM5 was observed in HCC and induced unfavorable prognosis. MCM5 expression had a negative correlation with miR-3607. MCM5 can abolish the suppressive impacts of miR-3607 on HCC cell malignant behaviors and the epithelial-mesenchymal transition (EMT) process. To sum up, our results unveiled that miR-3607 could inhibit HCC cell growth, migration, and invasion by regulating MCM5 and mediating EMT process, suggesting a new probable biomarker for further treatment of HCC.


Assuntos
Carcinoma Hepatocelular/genética , Proteínas de Ciclo Celular/genética , Neoplasias Hepáticas/genética , MicroRNAs/genética , Idoso , Biomarcadores Tumorais/genética , Carcinoma Hepatocelular/patologia , Movimento Celular/genética , Transição Epitelial-Mesenquimal/genética , Feminino , Regulação Neoplásica da Expressão Gênica/genética , Células Hep G2 , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica/genética , Invasividade Neoplásica/patologia , Prognóstico
2.
Echocardiography ; 34(2): 199-209, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28240430

RESUMO

AIMS: The feasibility and accuracy of an automated adaptive algorithm (Heart Model) for the quantification of left heart chamber volumes and left ventricular ejection fraction has been reported earlier. An improved version of the algorithm is available, and we aimed to test its accuracy compared with manual 3D echocardiography. METHODS AND RESULTS: Apical 3D transthoracic datasets were obtained in 67 patients. Acquisitions covering ventricles and atria were performed for analysis using the automated software (Heart Model, Philips Healthcare). In addition, acquisitions focused on the left ventricle were acquired for left ventricle manual 3D measurements (QLAB 10 3DQA, Philips Healthcare). Automated results using endocardial contouring settings at 50% showed a strong correlation with manual 3D measurements (r=.84-.97). Left ventricular end-diastolic volumes were underestimated (bias -5.9 mL, LOA ±38.5 mL), with no significant differences in other parameters. Intra-observer variability using the automated algorithm was zero for all parameters given the lack of human interaction. Manual corrections of the automatic algorithm introduced small but significant differences in volumes but not in ejection fraction when compared with automatic results. Manually corrected results of the automatic algorithm were not significantly different from those obtained with manual 3D echocardiography, except for a small underestimation of left atrial volumes (bias -2.1 mL, LOA ±15.2 mL). CONCLUSIONS: The current improved version of the automated adaptive algorithm is accurate for the assessment of left heart chamber volumes, albeit a small underestimation of left ventricular end-diastolic volume is seen, when compared with manual 3D echocardiography.


Assuntos
Ecocardiografia Tridimensional/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Algoritmos , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia
3.
J Heart Valve Dis ; 25(3): 289-295, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27989038

RESUMO

BACKGROUND: The echocardiographic grading of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) severity is challenging. The study aim was to assess the value of quantitative Doppler echocardiography to monitor PVL severity. METHODS: A total of 100 subjects was enrolled in the study, including 65 consecutive patients who had undergone TAVI with a CoreValve prosthesis and without valvular aortic regurgitation, and 35 normal controls. The PVL volume was calculated using the quantitative Doppler method as the difference of left and right ventricular stroke volume (SV). PVL severity was assessed both visually and quantitatively as the circumferential extent on a short-axis view (SAX). RESULTS: The inter-observer variabilities for SVs in TAVI patients were disappointing: 14 ± 11% for the left ventricular SV and 18 ± 14% for right ventricular SV. The correlation (r2) between the averaged regurgitant PVL volume and circumferential SAX extent of PVL was 0.02 (p = NS). The relationship between PVL volumes and categories, defined quantitatively by the circumferential SAX extent of PVL and qualitatively by visual assessment of severity of PVL were poor. The results improved when only patients with optimal quality images were included but were still statistically non-significant. CONCLUSIONS: The relationship between calculated PVL volume in TAVI patients and other estimates of PVL severity was poor, most likely due to intrinsic errors made in the quantitative Doppler method. Therefore, one should be prudent to include the quantitative Doppler method in TAVI patients in clinical trials and clinical decision-making, in particular in patients with reduced image quality.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia Doppler , Substituição da Valva Aórtica Transcateter/efeitos adversos , Adulto , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estudos de Casos e Controles , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular Direita
4.
Cardiovasc Ultrasound ; 14(1): 37, 2016 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-27600600

RESUMO

To make assessment of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) more uniform the second Valve Academic Research Consortium (VARC) recently updated the echocardiographic criteria for mild, moderate and severe PVL. In the VARC recommendation the assessment of the circumferential extent of PVL in the short-axis view is considered critical. In this paper we will discuss our observational data on the limitations and difficulties of this particular view, that may potentially result in overestimation or underestimation of PVL severity.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Humanos , Desenho de Prótese , Falha de Prótese , Fatores de Risco
5.
Am J Physiol Heart Circ Physiol ; 307(10): H1430-7, 2014 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-25217651

RESUMO

The purpose of this study was to assess left atrial (LA) function and myocardial mechanics in patients with degenerative mitral regurgitation (MR). Eighty patients with degenerative MR and twenty control subjects were included prospectively. LA volume (LAV) and right atrial (RA) volume (RAV) were measured with three-dimensional transthoracic echocardiography at three phases of the cardiac cycle as maximal volume (LAVmax and RAVmax), minimal volume (LAVmin and RAVmin), and volume before atrial contraction (LAVpre-A and RAVpre-A). From these volumes, active stroke volume (SV), distensibility, and emptying fraction were calculated. LA strain and strain rate were measured with vector velocity imaging on four- and two-chamber views. Left ventricular (LV) filling pressures were increased in patients with severe MR (E/E': 16 ± 4 vs. 10 ± 3 in control subjects). LAVmax, LAVmin, and LAVpre-A all increased with increasing MR volume. As LAVpre-A increased, both LA total SV (r = 0.68, P < 0.001) and passive filling volume (r = 0.76, P < 0.001) increased. LA active SV increased with LAVpre-A up to a certain point, upon which it decreased despite further increased LAVpre-A (r = 0.53, P < 0.001). LA late negative strain decreased with increasing MR volume. A positive correlation existed between LA late negative strain and LA active emptying fraction (r = 0.55, P < 0.001). In contrast, RA function was comparable between groups. In conclusion, LA contractility (active SV) increased in response to an increase in LA preload (LAVpre-A) up to a point beyond which LA contractility (active SV) decreased. Whether this is due to working of the LA at the descending limb of the Frank-Starling curve or mainly due to changes in afterload still remains unclear.


Assuntos
Função do Átrio Esquerdo , Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Contração Miocárdica , Adaptação Fisiológica , Idoso , Estudos de Casos e Controles , Ecocardiografia Tridimensional , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Modelos Cardiovasculares , Estudos Prospectivos , Fatores de Tempo , Função Ventricular Esquerda , Pressão Ventricular
6.
J Heart Valve Dis ; 23(6): 721-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25790619

RESUMO

BACKGROUND AND AIM OF THE STUDY: Mitral regurgitation (MR) is a common disorder for which mitral valve surgery is an established therapy. Although surgical indications are clearly defined for the management of valvular heart disease, a gap exists between current guidelines and their effective application. The study aim was to provide an insight into the diagnostic information provided for cardiac surgeons before performing mitral valve surgery. METHODS: The source documents and echocardiographic studies of 100 patients, referred by nine hospitals, were screened for arguments for MR severity justifying referral for surgery. Details of the documented MR mechanism, mitral annulus (MA) size, tricuspid regurgitation (TR) severity and annulus size were also noted. RESULTS: According to the referring physician, MR was severe in 83% and moderate-to-severe in 17%. In the great majority of patients (98%) the MR mechanism was mentioned, although specific information on the prolapsing scallops was available in only 17% of cases. The recommended primary determinants of MR severity, vena contracta and proximal isovelocity surface area (PISA) were measured in only 22% and 31% of patients, respectively. In 94% of patients with available PISA information this was described only qualitatively. Correct image expansion using the zoom mode was performed in only 25% of these patients, and a correct adaptation of the Nyquist limit in only 6%. Tricuspid annulus measurements guiding the need for concomitant tricuspid valvuloplasty in patients with less than severe TR were reported in only 6% of patients. CONCLUSION: These data demonstrate a clear and important gap between current guidelines and real-world practice with regards to the echocardiographic diagnostic information provided to the surgeon before performing mitral valve surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Fidelidade a Diretrizes , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Idoso , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Avaliação das Necessidades , Países Baixos , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Encaminhamento e Consulta , Índice de Gravidade de Doença , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia
8.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 44(1): 84-8, 2013 Jan.
Artigo em Zh | MEDLINE | ID: mdl-23600217

RESUMO

OBJECTIVE: To compare the results of 2D and 3D echocardiography in measuring aortic annulus diameter (AAD). METHODS: Preoperitve transesophageal echocardiography (TEE), transthoracic echocardiography (TTE) and 3D transesophageal echocardiography (RT 3D TEE) were performed on 52 patients who underwent aortic valve replacements to measure AAD. The parameters were compared between systole and diastole. RESULTS: The parameters in systole were significant greater than those in diastole (P < 0.05). No significant differences in the AAD value were found between TTE and TEE. However, the AAD values determined with TTE and TEE were different from those determined with RT 3D TEE (P < 0.05). The two-dimensional measurements produced smaller AAD values in both systole and diastole than the 3D measurements (P < 0.001). TEE correlated well with RT 3D TEE, with the r value of 0.775 and 0.765 for systole and diastole, respectively. The regression was 3D-AADs = 0.531 x TEE-AADs + 19.879 (mm). CONCLUSION: RT 3D TEE can accurately reconstruct the 3D structure of aortic annulus and calculate the aortic annulus dimension. TEE-AAD correlates well with 3D-AAD.


Assuntos
Valva Aórtica , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Diástole , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Humanos , Sístole
9.
J Cardiovasc Imaging ; 30(4): 292-304, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36280271

RESUMO

BACKGROUND: Calcium is a determinant of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI). This is based on a fixed contrast attenuation value while X-ray attenuation is patient-dependent and without considering frame expansion and PVL location. We examined the role of calcium in (site-specific) PVL after TAVI using a patient-specific contrast attenuation coefficient combined with frame expansion. METHODS: 57 patients were included with baseline CT, post-TAVI transthoracic echocardiography and rotational angiography (R-angio). Calcium load was assessed using a patient-specific contrast attenuation coefficient. Baseline CT and post-TAVI R-angio were fused to assess frame expansion. PVL was assessed by a core lab. RESULTS: Overall, the highest calcium load was at the non-coronary-cusp-region (NCR, 436 mm3) vs. the right-coronary-cusp-region (RCR, 233 mm3) and the left-coronary-cusp-region (LCR, 244 mm3), p < 0.001. Calcium load was higher in patients with vs. without PVL (1,137 vs. 742 mm3, p = 0.012) and was an independent predictor of PVL (odds ratio, 4.83, p = 0.004). PVL was seen most often in the LCR (39% vs. 21% [RCR] and 19% [NCR]). The degree of frame expansion was 71% at the NCR, 70% at the RCR and 74% at the LCR without difference between patients with or without PVL. CONCLUSIONS: Calcium load was higher in patients with PVL and was an independent predictor of PVL. While calcium was predominantly seen at the NCR, PVL was most often at the LCR. These findings indicate that in addition to calcium, specific anatomic features play a role in PVL after TAVI.

10.
Bioprocess Biosyst Eng ; 34(5): 629-37, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21229265

RESUMO

A highly selective sucrose isomerase (SIase) was purified to homogeneity from the cell-free extract of Erwinia rhapontici NX-5 with a recovery of 27.7% and a fold purification of 213.6. The purified SIase showed a high specific activity of 427.1 U mg(-1) with molecular weight of 65.6 kDa. The K (m) for sucrose was 222 mM while V (max) was 546 U mg(-1). The optimum pH and temperature for SIase activity were 6.0 and 30 °C, respectively. The purified SIase was stable in the temperature range of 10-40 °C and retained 65% of the enzyme activity after 2 weeks' storage at 30 °C. The SIase activity was enhanced by Mg(2+) and Mn(2+), inhibited by Ca(2+), Cu(2+), Zn(2+), and Co(2+), completely inhibited by Hg(2+) and Ag(2+). The purified SIase was strongly inhibited by SDS, while partially inhibited by dimethylformamide, tetrahydrofuran, and PMSF. Additionally, glucose and fructose acted as competitive inhibitors for purified SIase.


Assuntos
Proteínas de Bactérias , Erwinia/enzimologia , Glucosiltransferases , Proteínas de Bactérias/química , Proteínas de Bactérias/isolamento & purificação , Proteínas de Bactérias/metabolismo , Cálcio/química , Dimetilformamida/química , Frutose/metabolismo , Furanos/química , Glucose/metabolismo , Glucosiltransferases/química , Glucosiltransferases/isolamento & purificação , Glucosiltransferases/metabolismo , Concentração de Íons de Hidrogênio , Cinética , Magnésio/química , Metais Pesados/química , Peso Molecular , Octoxinol/química , Dodecilsulfato de Sódio/química , Sacarose/metabolismo , Temperatura
11.
Eur Heart J Case Rep ; 5(1): ytaa573, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33521516

RESUMO

BACKGROUND: Infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) occurs in up to 1.5% of patients within the first year. The development of an aorto-atrial fistula (AAF) is a rare but problematic complication of IE, which can be confirmed with transoesophageal echocardiography (TOE). We present an exceptional case of occluding an aorto-left atrial fistula only diagnosed with intraprocedural TOE during a subsequent procedure of MitraClip implantation. CASE SUMMARY: A 79-year-old symptomatic male patient with multiple comorbidities was referred due to severe mitral regurgitation (MR). He has had prior TAVI which was complicated with streptococcal IE for which he had received prolonged antibacterial therapy. Transthoracic echocardiography (TTE) revealed severe MR. The patient was accepted for a MitraClip procedure by the heart team. Intra-procedural TOE revealed also a significant continuous shunt through an AAF which was likely caused by the endocarditis. The strategy was therefore defined as to occlude the fistula with an Amplatzer Vascular Plug II 12 mm. The plug was released in the fistula leaving an insignificant residual shunt. After the transseptal puncture one MitraClip XTR was implanted, reducing the MR to mild. After the procedure, the patient's general clinical condition improved without signs of haemolysis. The pre-discharge TTE confirmed trace residual shunt, mild residual MR and mild paravalvular leakage. DISCUSSION: Our case illustrates a complex transcatheter structural heart intervention with improvised procedural strategies based on the intra-procedural TOE findings. We conclude that the pre-procedural TOE needs to be comprehensive rather than exclusive, particularly in the context of bioprosthesis-related endocarditis.

12.
JACC Case Rep ; 3(16): 1782-1786, 2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34825210

RESUMO

We present the case of a 71-year-old man admitted because of chest tightness, palpitations, and progressive shortness of breath. The diagnosis of severe aortic stenosis, coarctation, and aneurysm was established, as well as severely depressed left ventricular ejection fraction. Three consecutive transcatheter procedures were successfully performed in a single session. (Level of Difficulty: Advanced.).

13.
Acta Cardiol ; 76(2): 185-193, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31920151

RESUMO

BACKGROUND: Elevated pulmonary artery pressure (PAP) in patients with severe aortic stenosis (AS) is a strong predictor of adverse prognosis. This study sought to assess the relation between PAP and clinical and echocardiographic parameters in elderly patients with severe AS, as well as to identify the determinants of the change in PAP after transcatheter aortic valve implantation (TAVI). METHODS: The study included 170 subjects (age 81 ± 7 years, 45% men) with symptomatic severe AS who were treated by TAVI. They underwent a clinical evaluation and a transthoracic echocardiography before the TAVI procedure and 6 months after. RESULTS: In a multivariable analysis, the independent predictors for baseline PAP were the body mass index (BMI) (ß = 0.21, p = .006), COPD GOLD class (ß = 0.20; p = .009), the E/e' ratio (ß = 0.20; p = .02) and the degree of aortic regurgitation (ß = 0.20; p = .01). After TAVI, there was significantly less (51% vs. 29%, p<.0001) pulmonary hypertension, defined as a tricuspid regurgitation velocity ≥2.8 m/s. The baseline variables related to an improvement in PAP were the tricuspid regurgitation velocity (p = .0001) and the E/e' (p = .005). From the parameters potentially modified with TAVI, the only independent predictor of PAP variation was the change in the E/e' ratio (ß = 0.23; p = .01). CONCLUSIONS: Independent predictors for baseline PAP in elderly patients with symptomatic AS were the BMI, GOLD class, the aortic regurgitation and the E/e' ratio. The baseline predictors for a change in PAP 6 months after TAVI were the baseline PAP and E/e', with only the change in the E/e' ratio being correlated to the change in PAP.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Pressão Arterial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem
14.
Sci Rep ; 11(1): 13022, 2021 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-34158575

RESUMO

Childhood obesity continues to escalate worldwide and may affect left ventricular (LV) geometry and function. The aim of this study was to investigate the impact of obesity on prevalence of left ventricular hypertrophy (LVH) and diastolic dysfunction in children. In this analysis of prospectively collected cross-sectional data of children between 5 and 16 years of age from randomly selected schools in Peru, parameters of LV geometry and function were compared according to presence or absence of obesity (body mass index z-score > 2). LVH was based on left ventricular mass index (LVMI) adjusted for age and sex and defined by a z-score of > 2. LV diastolic function was assessed using mitral inflow early-to-late diastolic flow (E/A) ratio, peak early diastolic tissue velocities of the lateral mitral annulus (E'), early diastolic transmitral flow velocity to tissue Doppler mitral annular early diastolic velocity (E/E') ratio, and left atrial volume index (LAVI). Among 1023 children, 681 children (mean age 12.2 ± 3.1 years, 341 male (50.1%)) were available for the present analysis, of which 150 (22.0%) were obese. LVH was found in 21 (14.0%) obese and in 19 (3.6%) non-obese children (padjusted < 0.001). LVMI was greater in obese than that in non-obese children (36.1 ± 8.6 versus 28.7 ± 6.9 g/m2.7, p < 0.001). The mean mitral E/E' ratio and LAVI were significantly higher in obese than those in non-obese individuals (E/E': 5.2 ± 1.1 versus 4.9 ± 0.8, padjusted = 0.043; LAVI 11.0 ± 3.2 versus 9.6 ± 2.9, padjusted = 0.001), whereas E' and E/A ratio were comparable. Childhood obesity was associated with left ventricular hypertrophy and determinants of diastolic dysfunction.ClinicalTrials.gov Identifier: NCT02353663.


Assuntos
Diástole/fisiologia , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/fisiopatologia , Obesidade/complicações , Obesidade/fisiopatologia , Adolescente , Índice de Massa Corporal , Criança , Feminino , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/patologia , Masculino , Miocárdio/patologia , Obesidade/patologia , Tamanho do Órgão
15.
Card Fail Rev ; 6: e09, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32411396

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic started in Wuhan, Hubei Province, China, in December 2019, and by 24 April 2020, it had affected >2.73 million people in 185 countries and caused >192,000 deaths. Despite diverse societal measures to reduce transmission of the severe acute respiratory syndrome coronavirus 2, such as implementing social distancing, quarantine, curfews and total lockdowns, its control remains challenging. Healthcare practitioners are at the frontline of defence against the virus, with increasing institutional and governmental supports. Nevertheless, new or ongoing clinical trials, not related to the disease itself, remain important for the development of new therapies, and require interactions among patients, clinicians and research personnel, which is challenging, given isolation measures. In this article, the authors summarise the acute effects and consequences of the COVID-19 pandemic on current cardiovascular trials.

16.
Biomed Pharmacother ; 121: 109642, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31731191

RESUMO

BACKGROUND: Recently, a growing number of reports indicated that long non-coding RNAs (lncRNAs) were involved in the development of various cancers. However, the performance of LINC00511 is still limited in hepatocellular carcinoma (HCC). Thus, we attempted to assess the effect of LINC00511 and underlying mechanism in HCC progression. METHODS: TCGA and GEO database acted as supporters to provide us clinical samples data. Overall survival (OS) analyses were plotted using Kaplan-Meier method. Five cell lines were utilized to detect LINC00511 expression level and Cell Counting Kit-8 (CCK-8), colony formation and transwell assays were conducted to examine the effects on cell behaviors. The correlations between LINC00511 and miR-195 or eyes absent homolog 1 (EYA1) were confirmed by luciferase reporter assay. Quantitative real-time PCR and western blotting were fulfilled to ascertain the mRNA and protein expression levels. RESULTS: In this study, we found that LINC00511 was high-regulated in HCC tissue samples and cell lines, which might be linked with unfavorable prognosis of HCC patients and clinical parameters. Loss-of-function experiments determined that LINC00511 deficiency inhibited cell proliferation, colony formation and invasive activity in HepG2 cells, while gain-of-function experiments showed the counter impacts in Huh7 cells. Bioinformatics tools and luciferase reporter assays revealed that LINC00511 may act as a competing endogenous RNA (ceRNA) for miR-195 and positively correlate with EYA1, which was reinforced by rescue experiments. CONCLUSION: Taken together, these findings indicated that LINC00511 interacted with EYA1 promoted HCC development via mediating miR-195, proposing a promising therapeutic biomarker for HCC diagnosis and prognosis.


Assuntos
Carcinoma Hepatocelular/genética , Movimento Celular/genética , Peptídeos e Proteínas de Sinalização Intracelular/genética , Neoplasias Hepáticas/genética , MicroRNAs/genética , Proteínas Nucleares/genética , Proteínas Tirosina Fosfatases/genética , Carcinoma Hepatocelular/patologia , Linhagem Celular Tumoral , Proliferação de Células/genética , Progressão da Doença , Transição Epitelial-Mesenquimal/genética , Feminino , Regulação Neoplásica da Expressão Gênica/genética , Células Hep G2 , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Prognóstico , RNA Longo não Codificante/genética
17.
JACC Cardiovasc Interv ; 13(15): 1803-1812, 2020 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-32682679

RESUMO

OBJECTIVES: The aim of this study was to assess the added value and predictive power of the TAVIguide (Added Value of Patient-Specific Computer Simulation in Transcatheter Aortic Valve Implantation) software in clinical practice. BACKGROUND: Optimal outcome after transcatheter aortic valve replacement (TAVR) may become more important as TAVR shifts toward low-risk patients. Patient-specific computer simulation is able to provide prediction of outcome after TAVR. Its clinical role and validation of accuracy, however, have not yet been studied prospectively. METHODS: A prospective, observational, multicenter study was conducted among 80 patients with severe aortic stenosis treated with the Evolut R valve. Simulation was performed in 42 patients and no simulation in 38. A comparison between the valve size (decision 1) and target depth of implantation selected by the operator on the basis of multislice computed tomography and the valve size (decision 2) and target depth of implantation selected after simulation were the primary endpoints. Predictive power was examined by comparing the simulated and observed degree of aortic regurgitation. RESULTS: Decision 2 differed from decision 1 in 1 of 42 patients because of predicted paravalvular leakage, and changes in valve type occurred in 2 of 42. In 39 of 42 patients, decisions 1 and 2 were similar. Target depth of implantation differed in 7 of 42 patients after simulation (lower in 4 and higher in 3). In 16 of 42 patients, simulation affected the TAVR procedure; in 9, the operator avoided additional measures to achieve the target depth of implantation, and in 7 patients, additional measures were performed. There was a trend toward a higher degree of predicted than observed aortic regurgitation (17.5 vs. 12 ml/s; p = 0.13). CONCLUSIONS: Patient-specific computer simulation did not affect valve size selection but did affect the selection of the target depth of implantation and the execution of TAVR to achieve the desired target depth of implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Tomada de Decisão Clínica , Europa (Continente) , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 27(6): 1998-2002, 2019 Dec.
Artigo em Zh | MEDLINE | ID: mdl-31839073

RESUMO

OBJECTIVE: To understand the infection of hepatitis B virus(HBV) in blood donors, and to evaluate the effectiveness and necessity of TMA technology for HBV-DNA screening in blood donors. METHODS: Using the ELISA/NAT model, routine serology test and NAT were performed in the 169 160 donors,including voluntary blood donors and some of donors returned to donor team. For some donors with test positive NAT, nucleic acid identification test was performed. And the HBsAg neutralized and confirmed assay would conduct in blood donors with unilateral HBsAg positive and HBV-DNA negative result. RESULTS: Among 169 160 donation cases-times, the donors of bilateral positive of HBsAg detection was 803, accounted for 0.476%; donors of unilateral positive was 243, accounted for 0.144%. For 40 specimens with HBV-DNA negative, unilateral HBsAg positive, the neutralization and confirmed assay was performed.In result, only 4 specimens were confirmed to be HBsAg positive, the confirmed positive rate was 10%. Among detected 1003 specimens with HBV-DNA positive specimens, both HBsAg and HBV-DNA positive were 739, the consistency rate between 2 kinds of detection was 73.7%. The comparision of positive rate detected by using 3 kinds of reagents showed that there were statistical differences (P<0.05); moreover, there were statistical difference in positive rate detected by using Murex reagent and In Tec reagent (P<0.0125). The comparison of detected rate of HBsAg+ and HBV-DNA+ during March 2016-February 2017 showed no statistical difference (P>0.05). Among 60 blood donors with HBsAg- and HBV-DNA+ who has retured to the donor team, 1 donor presented the transformation of HBsAg from negative to positive, suggesting the HBV infection of window period, HBsAg of the other 59 was negative. The detection of HBV-DNA showed that the HBV-DNA in 28 donors was negative, and the HBV-DNA in 31 donors was positive, 1 donor showed HBV-DNA was uncertain. CONCLUSION: The routine TMA technology combined with ELISA HBsAg can effectively shorten the window period for detection of HBV infection, effectively detect the occult HBV infection, and reduce the potential risk of hepatitis B spread due to blood transfusion.


Assuntos
Vírus da Hepatite B/genética , Hepatite B , Doadores de Sangue , DNA Viral , Antígenos de Superfície da Hepatite B , Humanos
20.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 27(3): 925-929, 2019 Jun.
Artigo em Zh | MEDLINE | ID: mdl-31204956

RESUMO

OBJECTIVE: To understand the iron stores of the plateletpheresis donors, so as to provide some new experimental data for further exploration and more perfect health examination criteria of the plateletpheresis donors. METHODS: A total of 297 plateletheresis donors conformed to standard in October 2018 were selected by the cross sectional study. The related factors affecting iron stores were analyzed; the effect of plateletpheresis times of donation on the levels of the hemoglobin(Hb) and serum ferritin(SF) as well as the iron deficency rate in the blood donors was also analyzed; the iron stores in the blood donors was evaluated. RESULTS: The SF level in plateletpheresis donors negatively correlated with annual plateletphersis times of donation(r=-0.416, P<0.001); The SF level decreased with the increase of annual times of donation(P<0.05); The iron deficiency rate in plateletpheresis donors showed the increase trend with the increase of annual times of donation. The iron deficiency rate in male and femal with 18-23 times of donation was 12.5%(8/64) and 40%(6/15) respectively. CONCLUSION: The blood center should reduce recruitment frequency and increase the testing of SF for regularly plateletpheresis donors.


Assuntos
Plaquetoferese , Doadores de Sangue , Estudos Transversais , Ferritinas , Hemoglobinas , Humanos , Ferro , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA