Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 51(6): 1669-1676, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31729119

RESUMO

BACKGROUND: Development of antiinflammatory drugs for lung diseases demands novel methods for noninvasive assessment of inflammatory processes in the lung. PURPOSE: To investigate the feasibility of hyperpolarized 129 Xe MRI, 1 H T1 time mapping, and dynamic contrast-enhanced (DCE) perfusion MRI for monitoring the response of human lungs to low-dose inhaled lipopolysaccharide (LPS) challenge compared to inflammatory cell counts from induced-sputum analysis. STUDY TYPE: Prospective feasibility study. POPULATION: Ten healthy volunteers underwent MRI before and 6 hours after inhaled LPS challenge with subsequent induced-sputum collection. FIELD STRENGTH/SEQUENCES: 1.5T/hyperpolarized 129 Xe MRI: Interleaved multiecho imaging of dissolved and gas phase, ventilation imaging, dissolved-phase spectroscopy, and chemical shift saturation recovery spectroscopy. 1 H MRI: Inversion recovery fast low-angle shot imaging for T1 mapping, time-resolved angiography with stochastic trajectories for DCE MRI. ASSESSMENT: Dissolved-phase ratios of 129 Xe in red blood cells (RBC), tissue/plasma (TP) and gas phase (GP), ventilation defect percentage, septal wall thickness, surface-to-volume ratio, capillary transit time, lineshape parameters in dissolved-phase spectroscopy, 1 H T1 time, blood volume, flow, and mean transit time were determined and compared to cell counts. STATISTICAL TESTS: Wilcoxon signed-rank test, Pearson correlation. RESULTS: The percentage of neutrophils in sputum was markedly increased after LPS inhalation compared to baseline, P = 0.002. The group median RBC-TP ratio was significantly reduced from 0.40 to 0.31, P = 0.004, and 1 H T1 was significantly elevated from 1157.6 msec to 1187.8 msec after LPS challenge, P = 0.027. DCE MRI exhibited no significant changes in blood volume, P = 0.64, flow, P = 0.17, and mean transit time, P = 0.11. DATA CONCLUSION: Hyperpolarized 129 Xe dissolved-phase MRI and 1 H T1 mapping may provide biomarkers for noninvasive assessment of the response of human lungs to LPS inhalation. By its specificity to the alveolar region, hyperpolarized 129 Xe MRI together with 1 H T1 mapping adds value to sputum analysis. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:1669-1676.


Assuntos
Lipopolissacarídeos , Isótopos de Xenônio , Administração por Inalação , Estudos de Viabilidade , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos
2.
Am J Respir Crit Care Med ; 199(9): 1086-1096, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30641027

RESUMO

Rationale: In the CLAIM study, dual bronchodilation with indacaterol/glycopyrronium (IND/GLY) significantly reduced hyperinflation, which translated into improved cardiac function, measured by left ventricular end-diastolic volume and cardiac output. Pulmonary microvascular blood flow (PMBF) is reduced in chronic obstructive pulmonary disease (COPD); however, the effect of reduced lung hyperinflation on PMBF remains unknown. Objectives: To determine the effect of lung deflation with IND/GLY on PMBF and regional pulmonary ventilation using magnetic resonance imaging (MRI) in hyperinflated patients with COPD. Methods: In this double-blind, randomized, two-period crossover study, gadolinium-enhanced MRI and phase-resolved functional lung MRI were used to measure PMBF and regional ventilation, respectively, in patients with COPD receiving IND/GLY versus placebo. Measurements and Main Results: Sixty-two patients were randomized to receive once-daily IND/GLY (110/50 µg) for 14 days, followed by 14 days of placebo, or vice versa. Treatment periods were separated by a 14-day washout. Sixty patients were included in the per-protocol analysis. MRI measurements showed significant improvements in total PMBF (P = 0.006) and regional PMBF (P values for individual lobes were between 0.004 and 0.022) in response to IND/GLY versus placebo. Regional ventilation was also significantly improved with IND/GLY, as evidenced by a 12.4% increase versus placebo (P = 0.011), a 14.3% relative decrease in ventilation defect percentage of nonventilated/hypoventilated lung tissue (cutoff was defined as 0.075 regional ventilation; P = 0.0002), and a 15.7% reduction in the coefficient of variation of regional ventilation compared with placebo (P < 0.0001). Conclusions: Pharmacologic intervention with IND/GLY improves pulmonary microvascular blood flow and regional ventilation in patients with COPD with hyperinflation. Clinical trial registered with www.clinicaltrials.gov (NCT02442206).


Assuntos
Antiasmáticos/uso terapêutico , Glicopirrolato/uso terapêutico , Indanos/uso terapêutico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Quinolonas/uso terapêutico , Idoso , Débito Cardíaco/efeitos dos fármacos , Estudos Cross-Over , Método Duplo-Cego , Combinação de Medicamentos , Feminino , Humanos , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Pulmão/efeitos dos fármacos , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Circulação Pulmonar/efeitos dos fármacos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Função Ventricular Esquerda/efeitos dos fármacos
3.
Eur Radiol ; 29(3): 1276-1284, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30209593

RESUMO

AIM: To assess the frequency and severity of complications of balloon pulmonary angioplasty (BPA) using C-arm computed tomography (CACT) guidance. MATERIAL AND METHODS: 266 consecutive interventions in 67 patients (42 females, mean age 66 ± 13 years) were included. Selective CACT was acquired prior to the intervention for three-dimensional (3D) guidance and to select appropriate balloon size based on the measured vessel diameter. Complications during and after the procedure, the need for further interventions and the impact on patient safety and outcome were assessed and categorised according to the SIR Classification System to Complications by Outcome (Grade A-F). RESULTS: Overall, 237 interventions were conducted without any complications (89.1%). Minor complications not requiring additional treatment occurred during or after 25 procedures (9.4%), including recurring dry cough in four patients during a total of 11 interventions (4.1%) (Grade A), three focal dissections of the targeted pulmonary artery (1.1%), four cases of pulmonary haemorrhage (1.5%), one case of reperfusion oedema (0.4%) and six cases of post-interventional short-term hemoptysis (2.3%) (Grade B). Four cases of major complications requiring additional treatment were observed (1.5%): one case of pulmonary haemorrhage (0.4%) and two cases of post-interventional haemoptysis (0.8%), all resolved after medical therapy without requiring further intervention, and one case of atrial tachycardia induced during catheterisation, subsequently requiring pharmacological cardioversion (0.4%) (Grade C). No fatal or life-threatening peri- or post-interventional complications or mortality were observed (Grade D-F). CONCLUSION: BPA performed under CACT guidance appears to be a safe procedure with a low risk of severe complications. KEY POINTS: • CACT guidance of BPA is safe and successful. • CACT-guided BPA procedures have a low complication profile. • CACT guidance is a valuable tool to navigate BPA.


Assuntos
Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Segurança do Paciente/estatística & dados numéricos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Imageamento Tridimensional/métodos , Pneumopatias/terapia , Masculino , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
4.
Eur Radiol ; 29(4): 1693-1702, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30311032

RESUMO

OBJECTIVES: Chronic thromboembolic pulmonary hypertension (CTEPH) can be treated with balloon pulmonary angioplasty (BPA) in inoperable patients. Sensitive non-invasive imaging methods are missing to detect treatment response after a single BPA treatment session. Therefore, the aim of this study was to measure treatment response after a single BPA session using cardio-pulmonary MRI. MATERIALS AND METHODS: Overall, 29 patients with CTEPH were examined with cardio-pulmonary MRI before and 62 days after their initial BPA session. Pulmonary blood flow (PBF), first-pass bolus kinetic parameters, and biventricular mass and function were determined. Multiple linear regression analysis was implemented to estimate the relationship of PBF change in the treated lobe with treatment change of full width at half maximum (FWHM), cardiac output (CO), ventricular mass index (VMI), pulmonary transit time (PTT) and PBF change in the non-treated lobes. Paired Wilcoxon rank sum test and Spearman rho correlation were used. RESULTS: After BPA regional PBF increased in the treated lobe (p < 0.0001) as well as in non-treated lobes (p = 0.015). PBF treatment changes in the treated lobe were significantly larger compared with the non-treated lobes (p = 0.0049). Change in NT proBNP, MRI-derived mean pulmonary artery pressure (mPAP), PTT, FWHM, right ventricular (RV) ejection fraction, RV stroke volume, CO, VMI and PBF in the non-treated lobes correlated with PBF change in the treated lobe (p < 0.05). PBF changes in the treated lobe were independently predicted by PTT as well as PBF change in the non-treated lobes. CONCLUSION: Cardio-pulmonary MRI detects and quantifies treatment response after a single BPA treatment session. KEY POINTS: • Two months after BPA regional parenchymal pulmonary perfusion (PBF) increased in the total lung parenchyma (p = 0.005), the treated lobes (p < 0.0001) and non-treated lobes (p = 0.015). • The PBF treatment changes in the treated lobe were significantly larger than in the non-treated lobes (p = 0.0049). • Change in NT proBNP, MRI-derived mean pulmonary artery pressure, pulmonary transit time, full width at half maximum, right ventricular (RV) ejection fraction, RV stroke volume, cardiac output, ventricular mass index and PBF in the non-treated lobes correlated with PBF change in the treated lobe (p < 0.05).


Assuntos
Angioplastia com Balão/métodos , Hipertensão Pulmonar/terapia , Embolia Pulmonar/terapia , Idoso , Débito Cardíaco/fisiologia , Feminino , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar/fisiologia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Direita/fisiologia
5.
Eur Radiol ; 27(10): 4264-4270, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28361177

RESUMO

OBJECTIVE: To evaluate the feasibility of 2D-perfusion angiography (2D-PA) in order to quantify perfusion changes of the lung parenchyma pre- and post-balloon pulmonary angioplasty (BPA). METHODS: Thirty consecutive interventions in 16 patients with 99 treated pulmonary artery segments were included. To quantify changes in pulmonary blood flow using 2D-PA, the acquired digital subtraction angiographies (DSA) pre- and post-BPA were post-processed. A reference ROI in the treated pulmonary artery and a distal target ROI in the lung parenchyma were placed in corresponding areas on DSA pre- and post-BPA. Time to peak (TTP), peak density (PD) and area under the curve (AUC) were assessed. The ratios reference ROI to target ROI (TTPparenchyma/TTPinflow; PDparenchyma/PDinflow; AUCparenchyma/AUCinflow) were calculated. Relative differences of the 2D-PA parameters were correlated to changes in the pulmonary-flow-grade-score. RESULTS: The pulmonary-flow-grade-score improved after BPA (p<0.0001). Likewise, the ratio TTPparenchyma/TTPinflow shortened by 10% (p=0.0002), the PDparenchyma/PDinflow increased by 46% (p<0.0001) and the AUCparenchyma/AUCinflow increased by 36% (p<0.0001). A significant correlation between changes in the pulmonary-flow-grade-score and changes in PDparenchyma/PDinflow (ρ=0.48, p<0.0001) and AUCparenchyma/AUCinflow (ρ=0.31, p=0.0018) was observed. CONCLUSION: Quantification of pulmonary perfusion pre- and post-BPA using 2D-PA is feasible and has the potential to improve monitoring of BPA. KEY POINTS: • Quantification of BPA results by use of 2D-PA is feasible. • 2D-PA allows objective assessment of changes in lung parenchymal perfusion. • 2D-PA has the potential to optimize BPA.


Assuntos
Angiografia Digital/métodos , Angioplastia com Balão/métodos , Hipertensão Pulmonar , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Radiografia Intervencionista , Adulto , Idoso , Área Sob a Curva , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Masculino , Pessoa de Meia-Idade , Perfusão , Estudos Retrospectivos
6.
Radiology ; 279(3): 925-34, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26727392

RESUMO

Purpose To evaluate surgical success after pulmonary endarterectomy (PEA) by means of cardiopulmonary magnetic resonance (MR) imaging. Materials and Methods In this institutional review board-approved study, 20 patients with chronic thromboembolic pulmonary hypertension were examined at 1.5 T with a dynamic contrast material-enhanced three-dimensional fast low-angle shot sequence before and 12 days after PEA (25th-75th percentile range, 11-16 days). Lung segments were evaluated visually before PEA for parenchymal hypoperfused segments. Pulmonary blood flow (PBF), first-pass bolus kinetic parameters, and biventricular mass and function were determined. Mean pulmonary artery pressure (mPAP) and 6-minute walking distance were measured before and after PEA. The Shapiro-Wilk test, paired two-sided Wilcoxon rank sum test, Spearman ρ correlation, and multiple linear regression analysis were performed. Results Two weeks after PEA, regional PBF increased 66% in the total lung from 32.7 to 54.2 mL/min/100 mL (P = .0002). However, after adjustment for cardiac output, this change was not evident anymore (increase of 7% from 7.03 to 7.54 mL/min/100 mL/L/min, P = .1). Only in the lower lobes, a significant increase in PBF after cardiac output adjustment remained: a 16% increase in the right lower lobe from 7.53 to 8.71 mL/min/100 mL (P = .01) and a 14% increase in the left lower lobe from 7.42 to 8.47 mL/min/100 mL/L/min (P < .05). Right ventricular mass and function also improved. mPAP decreased from 46 to 24 mm Hg (P < .0001). Six-minute walking distance increased from 390 to 467 m (P = .02) 5 months after PEA. Percentage change of mPAP and PBF in the lower lobe tended to be significant predictors of percentage change in 6-minute walking distance (ß = -1.79 [P = .054] and ß = 0.45 [P = .076], respectively) in multiple linear regression analysis. Conclusion Improvement of PBF after PEA was observed predominantly in the lower lungs, and the magnitude of improvement of PBF in the lower lobes correlated with the improvement in exercise capacity, reflecting surgical success. (©) RSNA, 2016.


Assuntos
Endarterectomia/métodos , Hipertensão Pulmonar/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Tecido Parenquimatoso/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
Eur Radiol ; 26(11): 4064-4071, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26905868

RESUMO

PURPOSE: To investigate the feasibility of and compare two C-Arm CT (CACT) guidance methods during balloon pulmonary angioplasty (BPA). MATERIAL AND METHODS: Forty-two BPAs [27 CTEPH patients (nine males, 70 ± 14y)] targeting 143 pulmonary arteries were included. Twenty-two BPAs were guided by contrast-enhanced CACT acquired immediately before BPA (G3D). In another 20 BPAs (G2D), two orthogonal fluoroscopy images of the chest where acquired to compute a registration of a previously acquired CACT. Volume rendering-based graphic representations (VRT guidance) were generated indicating the origin and course of the vessels. Based on VRT guidance, the intervention was planned. Procedure durations and radiation exposure data were compared between the two groups (Wilcoxon test). RESULTS: The overall intervention time was approximately 2 h in both groups (p = 0.31). BPA was successfully performed in G3D 91 % and G2D 94 %. No significant difference was found concerning the mean dose area product (DAP) related to fluoroscopy (p = 0.38), while DAP related to DSA was slightly higher in G3D (p = 0.048). Overall, DAP was significantly higher in G3D (p = 0.002). CONCLUSIONS: The use of CACT for procedure guidance in patients undergoing BPA is feasible and accurate. Image fusion of a pre-acquired CACT can be used to decrease radiation exposure due to multiple BPA sessions. KEY POINTS: • BPA guidance by CACT overlay is feasible and safe. • 2D3D image fusion for BPA guidance is accurate. • Image fusion can reduce patient radiation dose due to repeated BPA sessions.


Assuntos
Angioplastia com Balão/métodos , Artéria Pulmonar/diagnóstico por imagem , Radiografia Intervencionista/instrumentação , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Idoso , Braço , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
J Vasc Interv Radiol ; 27(3): 361-8.e2, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26803575

RESUMO

PURPOSE: To compare the depiction of pulmonary arteries in pulmonary arterial catheter-based contrast-enhanced cone-beam CT with peripheral intravenous contrast-enhanced multidetector CT in patients with suspected chronic thromboembolic pulmonary hypertension. MATERIAL AND METHODS: In 20 patients (15 men and 5 women, 63.4 y ± 16.3), cone-beam CT using a catheter placed in the main pulmonary artery and 64-row multidetector CT using an appropriate venous access were performed. Contrast enhancement was measured in the main pulmonary artery, the right and left pulmonary arteries, and the left atrium. The amount of peripheral vessel conspicuity adjacent to the pleural surface (distance from vessel-to pleura) was measured. Two readers (R1, R2) independently evaluated the pulmonary arteries for image quality and pathologic findings in both modalities. RESULTS: Contrast density was higher in the main pulmonary artery and right and left pulmonary arteries (P < .002) and lower in the left atrium (P = .001) on cone-beam CT. The smallest distance between clearly delineated vessels and the pleura was significantly lower on cone-beam CT images (P < .0001). Interobserver agreement was good for cone-beam CT (κ = 0.79) and multidetector CT (κ = 0.78), whereas intermodality agreement was moderate (R1, κ = 0.60; R2, κ = 0.59). Both readers detected more weblike stenoses with cone-beam CT (76; 22%) compared with multidetector CT (25; 7%). CONCLUSIONS: Cone-beam CT shows improved contrast between pulmonary arteries and the left atrium and allows a more detailed depiction of the pulmonary arteries.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada de Feixe Cônico , Hipertensão Pulmonar/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Meios de Contraste/administração & dosagem , Feminino , Humanos , Hipertensão Pulmonar/etiologia , Infusões Intravenosas , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Iopamidol/administração & dosagem , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Embolia Pulmonar/complicações
9.
Radiology ; 274(1): 267-75, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25203130

RESUMO

PURPOSE: To evaluate oxygen-enhanced T1-mapping magnetic resonance (MR) imaging as a noninvasive method for visualization and quantification of regional inflammation after segmental allergen challenge in asthmatic patients compared with control subjects. MATERIALS AND METHODS: After institutional review board approval, nine asthmatic and four healthy individuals gave written informed consent. MR imaging (1.5 T) was performed by using an inversion-recovery snapshot fast low-angle shot sequence before (0 hours) and 6 hours and 24 hours after segmental allergen challenge by using either normal- or low-dose allergen or saline. The volume of lung tissue with increased relaxation times was determined by using a threshold-based method. As a biomarker for oxygen transfer from the lungs into the blood, the oxygen transfer function ( OTF oxygen transfer function ) was calculated. After the third MR imaging examination, eosinophils in bronchoalveolar lavage fluid were counted. Differences between times and segments were analyzed with nonparametric Wilcoxon matched-pairs test and Spearman correlation. RESULTS: In lung segments treated with the standard dose of allergen, the OTF oxygen transfer function was decreased at 6 hours in asthmatic patients, compared with saline-treated segments (P = .0078). In asthmatic patients at 24 hours, the volume over threshold was significantly increased in normal allergen dose-treated segments compared with saline-treated segments (P = .004). In corresponding lung segments, the volume over threshold at 24 hours in the asthmatic group showed a positive correlation (r = 0.65, P = .0001) and the OTF oxygen transfer function at 6 hours showed an inverse correlation (r = -0.67, P = .0001) with the percentage of eosinophils in the bronchoalveolar lavage fluid. CONCLUSION: OTF oxygen transfer function and volume over threshold are noninvasive MR imaging-derived parameters to visualize and quantify the regional allergic reaction after segmental endobronchial allergen challenge.


Assuntos
Asma/imunologia , Testes de Provocação Brônquica , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Asma/fisiopatologia , Líquido da Lavagem Broncoalveolar/citologia , Broncoscopia , Estudos de Casos e Controles , Feminino , Humanos , Inflamação/imunologia , Inflamação/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Espirometria
10.
Radiology ; 276(1): 266-73, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25816104

RESUMO

PURPOSE: To evaluate oxygen-enhanced T1-mapping magnetic resonance (MR) imaging of the lungs for detection of chronic lung allograft dysfunction (CLAD) in patients who have undergone double lung transplantation. MATERIALS AND METHODS: The local ethics committee approved this study. Seventy-six recipients of double lung allografts who underwent MR imaging of the lungs during an outpatient visit between 2011 and 2013 were included in this study after they provided written informed consent. Patients were classified as having CLAD on the basis of spirometric results and were divided into three groups: no CLAD (bronchiolitis obliterans syndrome level 0 [BOS 0]), early CLAD (BOS 0p), and late-stage CLAD (BOS 1-3). Coronal T1 maps of the lungs were acquired with the patient breathing room air and 100% oxygen by using an inversion-recovery snapshot fast low-angle shot sequence at 1.5 T. The median and interquartile range of T1 values at room air and at 100% oxygen and the oxygen transfer function were calculated. Statistical analysis was performed with analysis of variance and the Tukey honestly significant difference test or the Kruskal-Wallis test and the Mann-Whitney U test (α = 0.05). Bonferroni correction was applied for multiple comparisons. RESULTS: The oxygen transfer function was significantly lower in patients in the BOS 0p (P = .025) and BOS 1-3 groups (P = .003) than it was in the patients with BOS 0. Absolute T1 values (room air, P = .66; 100% oxygen, P = .67) did not differ significantly among the groups. The heterogeneity of T1 values, measured by using the interquartile range, showed a strong trend toward higher values in patients with BOS (room air, P = .06; 100% oxygen, P = .08). CONCLUSION: Oxygen transfer function may serve as an early marker for detection of CLAD.


Assuntos
Pneumopatias/diagnóstico , Transplante de Pulmão , Pulmão/patologia , Imageamento por Ressonância Magnética/métodos , Oxigênio , Adulto , Doença Crônica , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
J Magn Reson Imaging ; 41(1): 60-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24339056

RESUMO

PURPOSE: To evaluate the reproducibility of oxygen-enhanced magnetic resonance imaging (MRI), and the influence of different gas delivery methods, in a clinical environment. MATERIALS AND METHODS: Twelve healthy volunteers were examined on two visits with an inversion recovery snapshot fast low angle shot sequence on a 1.5 T system. Coronal slices were obtained breathing room air as well as 100% oxygen with a flow rate of 15 L/min. For oxygen delivery a standard nontight face mask and a full closed air-cushion face mask were used. T1 relaxation times and the oxygen transfer function (OTF) were calculated. RESULTS: The mean T1 values did not change significantly between the two visits (P > 0.05). The T1 values breathing 100% oxygen obtained using the full closed mask were significantly lower (1093 ± 38 msec; P < 0.05) compared to the standard mask (1157 ± 52 msec). Accordingly, the OTF was significantly higher for the full closed mask (P < 0.05). The OTF changed significantly on the second visit using the standard mask (P < 0.05). The full closed mask showed lower interindividual variation for both the T1 values (3.5% vs. 4.5%) as well as the OTF (12.4% vs. 22.0%) and no difference of the OTF on the second visit (P > 0.05). CONCLUSION: Oxygen-enhanced T1 mapping MRI produces reproducible data when using a full closed face mask.


Assuntos
Aumento da Imagem/métodos , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Máscaras , Oxigênio/administração & dosagem , Adulto , Análise de Variância , Meios de Contraste/administração & dosagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Reprodutibilidade dos Testes , Respiração
12.
J Magn Reson Imaging ; 42(1): 72-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25227559

RESUMO

PURPOSE: To evaluate the test performance of perfusion-weighted Fourier-decomposition (pw-FD) magnetic resonance imaging (MRI) in comparison to dynamic contrast-enhanced (DCE)-MRI as a reference standard in patients with known or suspected chronic pulmonary embolism (PE). MATERIALS AND METHODS: In 64 patients, chronic PE was ruled out or confirmed by DCE-MRI using a time-resolved angiography with stochastic trajectories (TWIST) sequence in one breath-hold. Pw-FD-MRI was performed using a 2D fast low-angle shot (FLASH) sequence in free-breathing. After a nonrigid image registration, FD was applied to generate pw-images. Lungs were scored by two radiologists (2 and 12 years of lung MRI experience) visually for each lobe and segment for hypoperfused areas. For intra- and interobserver variability, the MR images were analyzed 2 months after the first analysis, blinded to the results of the first reader. RESULTS: PE was diagnosed by DCE-MRI in 39 patients. For the pw-FD MRI sensitivity, specificity, accuracy, and positive and negative predictive value for diagnosis of PE were 100%, 95%, 98%, 98%, and 100% on a per-patient basis, 94%, 94%, 94%, 95%, 94% on a per-lobe basis, and 82%, 92%, 88%, 88%, 88% on a segmental basis, respectively. Detection of subsegmental and segmental hypoperfusion using pw-FD MRI showed a moderate agreement with DCE-MRI (kappa of 0.68; 95% confidence interval: 0.64; 0.72). CONCLUSION: Pw-FD of the lung is a feasible test to diagnose chronic PE on a per-patient level during free-breathing without the use of ionizing radiation or contrast agents.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Embolia Pulmonar/diagnóstico , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Doença Crônica , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego
13.
Eur Radiol ; 25(9): 2651-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25735514

RESUMO

OBJECTIVES: To assess the prevalence and morphologic characterization of pulmonary nodules in children on a chest computed tomography (CT). METHODS: Two hundred and fifty-nine trauma chest CTs in children aged 0-18 years were retrospectively reviewed by two radiologists, each with more than 10 years of experience. Images were acquired on a 64-row CT. Pulmonary lobes with trauma affections such as contusion or haemorrhage were excluded. All pulmonary nodules were evaluated for distance from the pleural surface, location, calcification and size on axial slices. RESULTS: A total of 1,190/1,295 (92%) pulmonary lobes without traumatic injury were included in this study. In 86 of 259 (33%) patients, 131 pulmonary nodules were detected. Number of nodules per patient ranged from 1 to 4. Calcifications were seen in 19% (25) of all nodules. Diameters ranged from 1 to 5 mm. 59% (77) were located in the lower lobes, 9% (12) in the middle lobe and 32% (42) in the upper lobes. 84% of the non-calcified nodules >2 mm showed a slightly angular or triangular (mostly pleural nodes) shape. CONCLUSIONS: Pulmonary nodules smaller than 5 mm can be detected frequently in children without malignant disease and are predominantly located in the lower lobes. KEY POINTS: • Pulmonary nodules in children with trauma CTs were retrospectively analysed • Pulmonary nodules seen on CT are frequent in children without malignant disease • Nodules in this group are more frequent in the lower lobes • No age dependency for the number of pulmonary nodules in children was observed.


Assuntos
Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Pulmão/diagnóstico por imagem , Masculino , Prevalência , Estudos Retrospectivos
14.
Am J Respir Crit Care Med ; 189(6): 650-7, 2014 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-24401150

RESUMO

RATIONALE: There is a need to develop novel noninvasive imaging biomarkers that help to evaluate antiinflammatory asthma treatments. OBJECTIVES: To investigate whether the extent of the segmental lung edema measured noninvasively using turbo-inversion recovery-magnitude magnetic resonance imaging (TIRM MRI) corresponds to the severity of the regional allergic reaction determined by the percentage of eosinophils in bronchoalveolar lavage fluid (BAL) 24 hours after segmental allergen challenge in patients with asthma compared with normal control subjects. METHODS: Eleven volunteers with allergic asthma and five healthy volunteers underwent segmental challenges with different allergen doses by two bronchoscopies 24 hours apart. They had lung MRI at baseline and 6 and 24 hours after segmental challenge. MRI TIRM scores were correlated with the eosinophilic response at 24 hours. MEASUREMENTS AND MAIN RESULTS: In patients with asthma, there were significant differences of eosinophil percentages in BAL at 24 hours from segments given standard-dose, low-dose, or no allergen (saline) (P < 0.001). Correspondingly significant differences between the TIRM score in allergen standard-dose, low-dose, and saline-treated segments were observed at 24 hours post-challenge (P < 0.001). With increasing TIRM score at 24 hours the percent eosinophils per segment 24 hours post-challenge also increased accordingly (P < 0.001). There was interobserver agreement for TIRM score grading (kappa = 0.72 for 24-h time point). CONCLUSIONS: The MRI-based noninvasive TIRM score is a promising biomarker for the noninvasive detection of the inflammatory response after segmental allergen challenge in patients with asthma and may serve to monitor the therapeutic effectiveness of novel antiinflammatory drugs in future human trials.


Assuntos
Asma/diagnóstico , Testes de Provocação Brônquica/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Asma/imunologia , Asma/patologia , Líquido da Lavagem Broncoalveolar/imunologia , Broncoscopia , Estudos de Casos e Controles , Eosinófilos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Índice de Gravidade de Doença
15.
Acta Radiol ; 55(8): 932-7, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24103917

RESUMO

BACKGROUND: Computed tomography pulmonary angiography (CTPA) is used most often in routine clinical practice for the assessment of a suspected pulmonary embolism. The diagnostic accuracy relies on sufficient contrast enhancement. PURPOSE: To evaluate whether image acquisition during shallow breathing can improve the image quality in patients with insufficient contrast enhancement during breath-hold examinations. MATERIAL AND METHODS: A total of 2786 CT pulmonary angiographies, acquired on a 64-row CT during deep-inspiration breath-hold, were reviewed. Twenty-four examinations were considered non-diagnostic due to poor contrast enhancement in the pulmonary arteries (PA), although they showed preserved vascular enhancement of the superior vena cava (SVC) and the ascending aorta (AO). Eleven flawed CTPA examinations, including severe breathing artifacts and incorrect triggering were excluded. In 13 of the remaining patients, the examination was repeated during shallow breathing. Vascular contrast enhancement was compared between both scans by measuring the relative enhancement within the SVC, the main PA, and the AO. Image quality was scored by two, clinically experienced radiologists. The values are given as median and [25th;75th] quartile. RESULTS: There was a significant difference in the CT values for the PA between the repeated scans (P = 0.0002, Wilcoxon test), and with the CTPA in deep-inspiration showing a median enhancement of 97 HU (59-173), compared with 303 HU (239-385) in the CTPA acquired during free breathing. The differences for both the AO (P = 0.54) and the SVC (P = 0.78) were not significant. Scoring for the attenuation quality rose significantly (P = 0.0002) and no severe motion artifacts were detected on either scans. CONCLUSION: If there is insufficient pulmonary artery enhancement during CTPA, attenuation of the pulmonary arteries can be improved by acquisition during shallow breathing and is without significant loss of the overall diagnostic image quality.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Respiração , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Criança , Pré-Escolar , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Lactente , Recém-Nascido , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
16.
Rofo ; 193(4): 417-426, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32882728

RESUMO

PURPOSE: To evaluate the influence of patient alignment and thereby heel effect on the image quality (IQ) of C-arm flat-panel detector computed tomography (CACT). MATERIALS AND METHODS: An ACR phantom placed in opposite directions along the z-axis (setup A and B) on the patient support was imaged using CACT. Image acquisition was performed with three different image acquisition protocols. The images were reconstructed with four convolution kernels. IQ was assessed in terms of high contrast using the modulation transfer function (MTF) and low contrast by assessing the image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) as well as the reliability of density measurements. Furthermore, the dose intensity profiles were measured free-in-air. RESULTS: The MTF in setup B is higher than the MTF measured in setup A (p < 0.01). The image noises measured in setup A for the air and bone inserts were higher compared to those measured in setup B (p > 0.05). Opposite behavior has been observed for the polyethylene, water-equivalent and acrylic inserts. The SNR for all inserts is inversely related to the image noise. A systematically increasing or decreasing trend of CNR could not be observed (p > 0.05). The intensity profile measured by the detector system free-in-air showed that the anode heel effect is perpendicular to the z-axis. CONCLUSION: The patient alignment has a minor influence on the IQ of CACT. This effect is not based on the X-ray anode heel effect but is caused mainly by the non-symmetrical rotation of CACT. KEY POINTS: · The impact of patient alignment and thereby the heel effect on the image quality of CACT was analyzed.. · The patient alignment has a minor influence on the physical parameters related to image quality, such as noise, SNR, and MTF.. · This effect is based mainly on the non-symmetrical rotation of CACT.. CITATION FORMAT: · Alikhani B, Renne J, Maschke S et al. Impact of Patient Alignment on Image Quality in C-Arm Computed Tomography - Evaluation Using an ACR Phantom. Fortschr Röntgenstr 2021; 193: 417 - 426.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Humanos , Posicionamento do Paciente , Imagens de Fantasmas , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/normas
17.
Rofo ; 193(9): 1074-1080, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33634459

RESUMO

PURPOSE: To evaluate the feasibility and image quality of a motion correction algorithm for supra-selective C-arm computed tomography (CACT) of the pulmonary arteries in patients with chronic thromboembolic pulmonary hypertension (CTEPH) undergoing balloon pulmonary angioplasty (BPA). MATERIALS & METHODS: CACT raw data acquired during 30 consecutive BPAs were used for image reconstruction using either standard (CACTorg) or a motion correction algorithm (CACTmc), using 400 iterations. Two readers independently evaluated 188 segmental and 564 sub-segmental contrast-enhanced pulmonary arteries in each reconstruction. The following categories were assessed: Sharpness of the vessel, motion artifacts, delineation of bronchial structures, vessel geometry, and visibility of treatable lesions. The mentioned criteria were rated from grade 1 to grade 3: grade 1: excellent quality; grade 2: good quality; grade 3: poor/seriously impaired quality. Inter-observer agreement was calculated using Cohen's Kappa. Due to an excellent agreement, the ratings of both readers were merged. Differences in the assessed image quality criteria were evaluated using pairwise Wilcoxon signed-rank test. RESULTS: Inter-observer agreement was excellent for all evaluated image quality criteria (κ > 0.81). For all assessed image quality criteria, the ratings on CACTorg were good but improved significantly for CACTmc to excellent for the whole vascular tree (p < 0.01). When considering segmental and sub-segmental levels individually, all image quality criteria improved significantly for CACTmc on both levels (p < 0.01). While ratings of CACTmc were constant for both levels (segmental and sub-segmental) for all criteria, the ratings of CACTorg were slightly impaired for the sub-segmental arteries. CONCLUSION: Motion correction for supra-selective contrast-enhanced CACT of the pulmonary arteries is feasible and improves the overall image quality. KEY POINTS: · Motion artifacts can severely impair the diagnostic accuracy of CACT.. · A motion correction algorithm can significantly improve image quality in CACT of the pulmonary arteries.. · Especially the overall image quality of sub-segmental branches is significantly improved.. CITATION FORMAT: · Maschke S, Werncke T, Becker LS et al. Motion Reduction for C-Arm Computed Tomography of the Pulmonary Arteries: Image Quality of a Motion Correction Algorithm in Patients with Chronic Thromboembolic Hypertension During Balloon Pulmonary Angioplasty. Fortschr Röntgenstr 2021; 193: 1074 - 1080.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Algoritmos , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/terapia , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Tomografia Computadorizada por Raios X
18.
Exp Dermatol ; 19(12): 1105-7, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20812962

RESUMO

Keratinocytes and activated T cells interact in skin inflammation by virtue of chemokines and cytokines. T cell-derived IL-17 has been described to play an important role in the course of psoriatic inflammation. In this study, we addressed how keratinocytes influence the secretion of IL-17 in autologous T cell subsets. We found that a co-culture of autologous keratinocytes and T cell-receptor-stimulated T cells markedly enhanced the production of IL-17. Besides the importance of direct cell contact, this effect was mainly mediated by IL-1 and could be blocked by the IL-1 antagonist anakinra. An additional increase in IL-17 production by IL-23 was only seen in the presence of IL-1, which thus plays a permissive role for the action of IL-23. Importantly, co-culture of keratinocytes with CCR6+ CD4+ T cells that are enriched for Th17 cells resulted in significantly higher IL-17 production compared to co-culture with CD4+ T cells.


Assuntos
Linfócitos T CD4-Positivos/metabolismo , Interleucina-17/metabolismo , Interleucina-1beta/metabolismo , Queratinócitos/metabolismo , Receptores CCR6/metabolismo , Anticorpos/imunologia , Anticorpos/farmacologia , Complexo CD3/imunologia , Linfócitos T CD4-Positivos/citologia , Linfócitos T CD4-Positivos/efeitos dos fármacos , Linfócitos T CD4-Positivos/imunologia , Células Cultivadas , Técnicas de Cocultura , Meios de Cultivo Condicionados/farmacologia , Humanos , Proteína Antagonista do Receptor de Interleucina 1/farmacologia , Interleucina-1beta/farmacologia , Interleucina-23/farmacologia , Queratinócitos/citologia , Ativação Linfocitária/efeitos dos fármacos , Ativação Linfocitária/imunologia , Proteínas Recombinantes/farmacologia
19.
PLoS One ; 15(9): e0238171, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32925924

RESUMO

Magnetic resonance imaging (MRI) is an emerging tool for diagnosis and treatment monitoring of chronic thromboembolic pulmonary hypertension (CTEPH). The current study aims to identify central pulmonary arterial hemodynamic parameters that reflect clinical, cardiac and pulmonary changes after PEA. 31 CTEPH patients, who underwent PEA and received pre- and postoperative MRI, were analyzed retrospectively. Central pulmonary arterial blood flow, lung perfusion and right heart function data were derived from MRI. Mean pulmonary arterial pressure (mPAP) and 5-month follow-up six-minute walk-distance (6MWD) were assessed. After PEA, mPAP decreased significantly and patients achieved a higher 6MWD. Central pulmonary arterial blood flow velocities, pulmonary blood flow (PBF) and right ventricular function increased significantly. Two-dimensional (2D) phase-contrast (PC) MRI-derived average mean velocity, maximum mean velocity and deceleration volume changes after PEA correlated with changes of 6MWD and right heart ejection fraction (RVEF). Deceleration volume is a novel 2D PC MRI parameter showing further correlation with PBF changes. In conclusion, 2D PC MRI-derived main pulmonary hemodynamic changes reflect changes of RVEF, PBF and 5-month follow-up 6MWD and may be used for future CTEPH patient monitoring after PEA.


Assuntos
Circulação Coronária , Endarterectomia , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/cirurgia , Imageamento por Ressonância Magnética , Circulação Pulmonar , Trombose/complicações , Idoso , Doença Crônica , Feminino , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Período Perioperatório , Estudos Retrospectivos
20.
Acad Radiol ; 26(2): 170-178, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29929935

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the feasibility of multiparametric magnetic resonance imaging (MRI) of the lungs to detect impaired organ function in a porcine model of ischemic injury within an ex-vivo lung perfusion system (EVLP) prior to transplantation. MATERIALS AND METHODS: Twelve pigs were anesthetized, and left lungs were clamped to induce warm ischemia for 3 hours. Right lungs remained perfused as controls. Lungs were removed and installed in an EVLP for 12 hours. Lungs in the EVLP were imaged repeatedly using computed tomography, proton MRI (1H-MRI) and fluorine MRI (19F-MRI). Dynamic contrast-enhanced derived parenchymal blood volume, oxygen washout times, and 19F washout times were calculated. PaO2 was measured for ischemic and normal lungs, wet/dry ratio was determined, histologic samples were assessed, and cytokines in the lung tissue were analyzed. Statistical analysis was performed using nonparametric testing. RESULTS: Eleven pigs were included in the final analysis. Ischemic lungs showed significantly higher wet/dry ratios (p = 0.024), as well as IL-8 tissue levels (p = 0.0098). Histologic assessment as well as morphologic scoring of computed tomography and 1H-MRI did not reveal significant differences between ischemic and control lungs. 19F washout (p = 0.966) and parenchymal blood flow (p = 0.32) were not significantly different. Oxygen washout was significantly prolonged in ischemic lungs compared to normal control lungs at the beginning (p = 0.018) and further prolonged at the end of the EVLP run (p = 0.005). CONCLUSION: Multiparametric pulmonary MRI is feasible in lung allografts within an EVLP system. Oxygen-enhanced imaging seems to be a promising marker for ischemic injury, enabling detection of affected lung segments prior to transplantation.


Assuntos
Flúor/farmacologia , Lesão Pulmonar/diagnóstico por imagem , Transplante de Pulmão/métodos , Pulmão/irrigação sanguínea , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Perfusão , Animais , Lesão Pulmonar/etiologia , Masculino , Radioisótopos de Oxigênio/farmacologia , Perfusão/efeitos adversos , Perfusão/instrumentação , Perfusão/métodos , Imagem de Perfusão/métodos , Reprodutibilidade dos Testes , Suínos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA