Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Biochem ; 114: 63-66, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36773631

RESUMO

OBJECTIVES: Non-linearity in lipase assays and the ensuing gaps in results distribution have been described on Roche analysers, but have yet to be studied on other analysers. DESIGN AND METHODS: Eighteen lithium-heparinized plasma pools of lipase activities decreasing from 1700 to <4 U/L were prepared for multicentric evaluation on several analysers. Non-linearity was modelled as the difference between the polynomial regression of lipase activities depending on relative dilutions over the primary measuring range, and the linear regression of the same variables above the manufacturer's limit of linearity (MLL). Gaps in lipase distribution resulting from non-linearity were graphically evidenced through histograms. Upper limits of gaps were calculated, which are lipase activities where non-linearity biases no longer impact the diluted lipase results. RESULTS: MLLs and lipase (U/L) calculated at MLL (%biases versus MLL) were respectively: 1200 and 1124 (-6.3%) on the Architect C16000 (Abbott); 300 and 248 (-17.3%) on the Cobas c503 (Roche); 1500 and 1458 (-2.8%) on the Dimension Vista (Siemens); and 700 and 659 (-5.9%) on the Atellica CH930 (Siemens). Using Sentinel Lipase reagents on Abbott analysers, these measurements were respectively: 300 and 294 (-2.0%) on the Architect C16000, and 300 and 298 (-0.7%) on the Alinity. Setting Randox Lipase reagents on the Alinity, MLL and lipase at MLL were 953 and 776 (-18.6%), respectively. CONCLUSIONS: Considering the desirable (±14.2 %) and optimal (±7.1 %) allowable total error for lipase (EFLM/EuBIVAS), biases at manufacturer's limit of linearity were acceptable, except for Roche Cobas c503 method and Randox method on Abbott Alinity.


Assuntos
Acetamidas , Lipase , Humanos , Modelos Lineares , Algoritmos
2.
J Clin Med ; 9(6)2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32516898

RESUMO

BACKGROUND: Early brain injuries (EBI) are one of the most important causes of morbidity and mortality after subarachnoid hemorrhage. At admission, a third of patients are unconscious (spontaneously or sedated) and EBI consequences are not evaluable. To date, it is unclear who will still be comatose (with severe EBI) and who will recover (with less severe EBI) once the aneurysm is treated and sedation withdrawn. The objective of the present study was to determine the diagnostic accuracy of S100B levels at hospital admission to identify patients with severe neurological consequences of EBI. METHODS: Patients were consecutively included in this prospective blinded observational study. A motor component of the Glasgow coma score under 6 on day 3 was used to define patients with severe neurological consequences of EBI. RESULTS: A total of 81 patients were included: 25 patients were unconscious at admission, 68 were treated by coiling. On day 3, 12 patients had severe consequences of EBI. A maximal S100B value between admission and day 1 had an area under the receiver operating characteristic curve (AUC) of 86.7% to predict severe EBI consequences. In patients with impaired consciousness at admission, the AUC was 88.2%. CONCLUSION: Early S100B seems to have a good diagnostic value to predict severe EBI. Before claiming the usefulness of S100B as a surrogate marker of EBI severity to start earlier multimodal monitoring, these results must be confirmed in an independent validation cohort.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA