Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Clin Transplant ; 38(1): e15212, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38041451

RESUMO

Pancreas transplantation alone (PTA) is a ß cell replacement option for selected patients with type 1 diabetes mellitus; concerns have been raised regarding deterioration in kidney function (KF) after PTA. This retrospective multicenter study assessed actual impact of transplantation and immunosuppression on KF in PTA recipients at three Transplant Centers. The primary composite endpoint 10 years after PTA was >50% eGFR decline, eGFR < 30 mL/min/1.73 m2 , and/or receiving a kidney transplant (KT). Overall, 822 PTA recipients met eligibility. Median baseline and 10-year eGFR (mL/min/1.73 m2 ) were 76.3 (58.1-100.8) and 51.3 (35.3-65.9), respectively. Primary composite endpoint occurred in 98 patients (53.5%) with 45 experiencing a >50% decrease in eGFR by 10 years post-transplant, 38 eGFR < 30 mL/min/1.73 m2 and 49 requiring KT. KF declined most significantly within 6 months post-PTA, more often in females and patients with better preserved GFR up to 5 years with 11.6% kidney failure at 10 years. Patient survival and death-censored graft survival were both 68% at 10 years with overall graft thrombosis rate 8%. KF declined initially after PTA but stabilized with further slow progression. In conclusion, prospective intervention studies are needed to test renal sparing interventions while gathering more granular data.


Assuntos
Diabetes Mellitus Tipo 1 , Transplante de Pâncreas , Feminino , Humanos , Estudos de Coortes , Diabetes Mellitus Tipo 1/cirurgia , Sobrevivência de Enxerto , Rim , Transplante de Pâncreas/efeitos adversos , Estudos Retrospectivos
2.
J Endocr Soc ; 8(6): bvae071, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38721109

RESUMO

Background: Customized and standard automated insulin delivery (AID) systems for use in pregnancies of women with preexisting type 1 diabetes (T1D) are being developed and tested to achieve pregnancy appropriate continuous glucose monitoring (CGM) targets. Guidance on the use of CGM for treatment decisions during pregnancy in the United States is limited. Methods: Ten pregnant women with preexisting T1D participated in a trial evaluating at-home use of a pregnancy-specific AID system. Seven-point self-monitoring of blood glucose (SMBG) was compared to the closest sensor glucose (Dexcom G6 CGM) value biweekly to assess safety and reliability based on the 20%/20 mg/dL criteria. Results: All participants completed the study with 7 participants satisfying the safety and reliability criteria with a mean absolute relative difference of 10.3%. Three participants did not fulfill the criteria, mainly because the frequency of SMBG did not meet the requirements. Conclusion: Dexcom G6 CGM is safe and accurate in the real-world setting for use in pregnant women with preexisting T1D with reduced SMBG testing as part of a pregnancy-specific AID system.

3.
Mayo Clin Proc ; 98(5): 748-749, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37137645
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA