Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmology ; 127(12): 1627-1641, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32544560

RESUMO

PURPOSE: To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of 10- and 15-µg bimatoprost implant in subjects with open-angle glaucoma (OAG) and ocular hypertension (OHT) after initial and repeated administrations. DESIGN: Randomized, 20-month, multicenter, subject- and efficacy evaluator-masked, parallel-group, phase 3 clinical study. PARTICIPANTS: Adults with OAG or OHT in each eye, open iridocorneal angle inferiorly in the study eye, and study eye baseline IOP (hour 0; 8 am) of 22-32 mmHg after washout. METHODS: Study eyes received bimatoprost implant 10 µg (n = 198) or 15 µg (n = 198) on day 1 with readministration at weeks 16 and 32, or twice-daily topical timolol maleate 0.5% (n = 198). Intraocular pressure was measured at hours 0 and 2 at each visit. MAIN OUTCOME MEASURES: Primary end points were IOP and change from baseline IOP through week 12. Safety measures included treatment-emergent adverse events (TEAEs) and corneal endothelial cell density (CECD). RESULTS: Both dose strengths of bimatoprost implant were noninferior to timolol in IOP lowering after each administration. Mean diurnal IOP was 24.0, 24.2, and 23.9 mmHg at baseline and from 16.5-17.2, 16.5-17.0, and 17.1-17.5 mmHg through week 12 in the 10-µg implant, 15-µg implant, and timolol groups, respectively. The incidence of corneal and inflammatory TEAEs of interest (e.g., corneal endothelial cell loss, iritis) was higher with bimatoprost implant than timolol and highest with the 15-µg dose strength. Incidence of corneal TEAEs increased after repeated treatment; with 3 administrations at fixed 16-week intervals, incidence of ≥20% CECD loss was 10.2% (10-µg implant) and 21.8% (15-µg implant). Mean best-corrected visual acuity (BCVA) was stable; 3 implant-treated subjects with corneal TEAEs had >2-line BCVA loss at their last visit. CONCLUSIONS: Both dose strengths of bimatoprost implant met the primary end point of noninferiority to timolol through week 12. One year after 3 administrations, IOP was controlled in most subjects without additional treatment. The risk-benefit assessment favored the 10-µg implant over the 15-µg implant. Ongoing studies are evaluating other administration regimens to reduce the potential for CECD loss. The bimatoprost implant has potential to improve adherence and reduce treatment burden in glaucoma.


Assuntos
Anti-Hipertensivos/administração & dosagem , Bimatoprost/administração & dosagem , Glaucoma de Ângulo Aberto/tratamento farmacológico , Pressão Intraocular/efeitos dos fármacos , Adulto , Idoso , Idoso de 80 Anos ou mais , Método Duplo-Cego , Implantes de Medicamento , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/tratamento farmacológico , Hipertensão Ocular/fisiopatologia , Timolol/uso terapêutico , Tonometria Ocular , Corpo Vítreo/efeitos dos fármacos , Adulto Jovem
2.
Vet Ophthalmol ; 21(4): 376-381, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29457333

RESUMO

OBJECTIVE: To determine the effect of a bimatoprost sustained-release intracameral implant (Bimatoprost SR) on episcleral venous pressure (EVP) in normal dogs. METHODS: Normotensive beagle dogs were randomized to receive Bimatoprost SR 30 µg (n = 7) or sham injection (needle insertion only, n = 7) in one eye on day 1. EVP was measured with an episcleral venomanometer through day 65. Episcleral aqueous outflow vessels were identified using fluorescence imaging following intracameral injection of indocyanine green in one additional animal. A separate cohort of dogs that had been trained for conscious intraocular pressure (IOP) measurements received Bimatoprost SR 30 µg (n = 8) in one eye; IOP was evaluated through day 66. RESULTS: Baseline mean EVP was 10.0 mmHg in the Bimatoprost SR group and 10.4 mmHg in the sham group. Eyes treated with Bimatoprost SR exhibited a transient increase in mean EVP that peaked at day 8, followed by a decrease to levels below baseline. From day 29 to day 65, the change in mean EVP from baseline ranged from -2.4 to -3.9 mmHg (P < 0.05 vs. sham). Baseline mean IOP in eyes treated with Bimatoprost SR was 14.9 mmHg, and a steady IOP reduction was maintained through day 66. Bimatoprost SR-treated eyes exhibited a selective, sustained dilation of aqueous outflow vessels that was not observed in sham-treated eyes. CONCLUSIONS: In normal dogs, Bimatoprost SR was associated with a transient increase in EVP followed by a sustained decrease. Changes in EVP were accompanied by a sustained dilation of aqueous outflow vessels.


Assuntos
Bimatoprost/uso terapêutico , Doenças do Cão/tratamento farmacológico , Esclera/irrigação sanguínea , Pressão Venosa/efeitos dos fármacos , Animais , Bimatoprost/administração & dosagem , Cães , Implantes de Medicamento , Feminino , Injeções Intraoculares/métodos , Injeções Intraoculares/veterinária , Pressão Intraocular/efeitos dos fármacos , Esclera/efeitos dos fármacos
3.
J Ocul Pharmacol Ther ; 40(1): 48-56, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37910805

RESUMO

Purpose: This study was intended to characterize the impact of meibomian gland dysfunction (MGD) on patients' quality of life. Methods: In this prospective, multicenter, noninterventional clinical study (NCT01979887), eligible individuals (age ≥40 years; absence of uncontrolled ocular/systemic disease) were categorized, based on composite grading of ocular symptoms, Schirmer score, and meibum quality, into (1) non-MGD, (2) mild/moderate MGD, or (3) severe MGD cohorts. The MGD Impact Questionnaire (MGD IQ), a 10-item patient-reported outcome measure, was self-administered at clinic visit on day 1, and readministered on day 22 to assess intervisit agreement regarding MGD IQ responses. Results: In total, 75 subjects were assigned to the study cohorts (25 per cohort). Across cohorts, MGD IQ item scores rose incrementally with increasing MGD severity. The severe MGD cohort experienced greater difficulty with reading and performance of leisure activities, greater time on eye care, and greater bother with eye care and eye appearance than the mild/moderate MGD cohort (all P < 0.05). Compared with the non-MGD cohort, the mild/moderate MGD cohort had greater difficulty working on computer, whereas the severe MGD cohort had greater difficulty reading, driving, and performing leisure activities, more frequent difficulty with outdoor activities, more time on eye care, and greater bother with eye care (all P < 0.05). Intervisit agreement between MGD IQ responses was fair to moderate (weighted kappa statistic 0.33‒0.58). Conclusions: Vision-related activities are negatively impacted by increasing severity of MGD. The MGD IQ instrument can help characterize disease severity and amplify the patient's voice in patient-centric clinical research. ClinicalTrials.gov NCT01979887.


Assuntos
Síndromes do Olho Seco , Disfunção da Glândula Tarsal , Adulto , Humanos , Síndromes do Olho Seco/diagnóstico , Disfunção da Glândula Tarsal/diagnóstico , Disfunção da Glândula Tarsal/terapia , Glândulas Tarsais , Estudos Prospectivos , Qualidade de Vida , Lágrimas
4.
J Ocul Pharmacol Ther ; 40(5): 297-308, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38687355

RESUMO

Purpose: To investigate gel stent implantation with and without intraoperative sustained-release mitomycin C (MMC SR) in a rabbit model for gel stent implantation, and to examine aqueous humor outflow (AHO) postimplantation. Methods: Four groups of rabbits were included. Group 1 was untreated (control). Groups 2, 3, and 4 received the gel stent without MMC, with MMC solution (subconjunctival injection), and with MMC SR (subconjunctival injection), respectively. Intraocular pressure (IOP) and AHO were assessed via tonometry and indocyanine green-based angiography, respectively. The main efficacy measure was change in IOP from baseline. Results: Following gel stent implantation, Groups 2, 3, and 4 maintained ≥20% IOP reduction (response) for a median duration of 1 week, 6.5 weeks, and 30 weeks, respectively. Angiography showed normal aqueous humor drainage (Group 1) beginning at the perilimbal trabecular plexus and continuing posteriorly to episcleral outflow vessels. Following implantation, drainage occurred preferentially and directly into the subconjunctival bleb. Conclusions: Gel stent implantation with MMC SR was most effective in achieving sustained, long-term IOP reduction in the rabbit model, compared with implantation with or without MMC solution. Bleb presence and the postimplantation aqueous angiography results indicated redirection of the AHO to the subconjunctival vasculature and presumed lymphatics, suggesting efficient glaucoma filtration to lower IOP in this model. This rabbit model and aqueous angiography may help refine understanding of the mechanism of action of minimally invasive glaucoma surgeries and ultimately translate to improved surgical devices and procedures for patients with glaucoma.


Assuntos
Humor Aquoso , Preparações de Ação Retardada , Cirurgia Filtrante , Pressão Intraocular , Mitomicina , Animais , Coelhos , Mitomicina/administração & dosagem , Mitomicina/farmacologia , Cirurgia Filtrante/métodos , Pressão Intraocular/efeitos dos fármacos , Humor Aquoso/metabolismo , Humor Aquoso/efeitos dos fármacos , Stents , Géis , Glaucoma/cirurgia , Glaucoma/tratamento farmacológico , Túnica Conjuntiva/cirurgia , Modelos Animais de Doenças
5.
Vet Ophthalmol ; 16(2): 163-6, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22612298

RESUMO

Objective Gonioscopy provides limited quantitative information to compare the iridocorneal anatomy across different species. In addition, the anatomic relationships by histologic examination are altered during processing. As a result, the comparative anatomy of the iridocorneal angle across several mammalian species was evaluated by Optical Coherence Tomography (OCT). Methods Cats, beagle dogs, minipigs, owl monkeys, cynomolgus monkeys, and rhesus monkeys (n = 6 or 7 per species) were evaluated. Imaging was performed using the OCT. The anterior chamber angle (ACA), angle opening distance (AOD), and the angle recess area (ARA) were evaluated. Results AC angle: cat (63 ± 6°) > owl monkey (54 ± 4°) > beagle dog (42 ± 4°) > minipig (40 ± 3°) > rhesus monkey (36 ± 1°) > cynomolgus monkey (34 ± 2°). AOD: cat (3.3 ± 0.5 mm) > owl monkey (2.05 ± 0.2 mm) > beagle dog (1.08 ± 0.1 mm) > rhesus monkey (0.92 ± 0.06 mm) > minipig (0.64 ± 0.04 mm) > cynomolgus monkey (0.43 ± 0.03 mm). ARA: cat (3.5 ± 0.1 mm(2) ) > owl monkey (1.41 ± 0.2 mm(2) ) > dog (0.88 ± 0.1 mm(2) ) > rhesus monkey (0.62 ± 0.06 mm(2) ) > minipig (0.21 ± 0.05 mm(2) ) > cynomolgus monkey (0.15 ± 0.01 mm(2) ). Conclusions This study benchmarks the normative iridocorneal angle measurements across different mammalian species by OCT. These data can be useful to compare iridocorneal angle measurements in disease states as OCT evolves as a common diagnostic tool in veterinary ophthalmic research and practice.


Assuntos
Olho/anatomia & histologia , Mamíferos/anatomia & histologia , Tomografia de Coerência Óptica/veterinária , Animais , Especificidade da Espécie
6.
Vet Ophthalmol ; 16(5): 370-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23227993

RESUMO

OBJECTIVE: Topical latanoprost 0.005% is commonly used in dogs with primary angle closure glaucoma (PACG), and marked miosis has been reported in the literature. To further explore the effect of topical latanoprost on anterior segment anatomy, we performed iridocorneal angle biometrics in normal beagle dogs. METHODS: Thirty-five normal female beagle dogs were assessed using anterior segment optical coherence tomography (AS-OCT). One eye of each dog was scanned with the AS-OCT in the superotemporal quadrant. One drop of latanoprost 0.005% was applied topically, and the OCT scan was repeated 30 min later. Images were imported into ImageJ, and pupil diameter, anterior chamber angle, angle opening distance, angle recess area (ARA), anterior chamber hemifield, and anterior chamber depth were measured. RESULTS: A single drop of latanoprost resulted in marked miosis, anterior bowing of the peripheral iris, narrowing of the iridocorneal angle, and shallowing of the anterior chamber. The anterior segment parameters demonstrated a significant reduction (P-value ≤ 0.001) from baseline following latanoprost with the exception of the ARA (P = 0.07). CONCLUSIONS: Latanoprost significantly decreases pupil diameter and narrows the iridocorneal angle in normal female beagle dogs. Therefore, the utility of latanoprost as a prophylactic treatment for PACG in fellow eyes may be limited. Studies using quantitative iridocorneal angle measurements in goniodysgenic dogs are warranted to understand the changes in iridocorneal angle morphology that occur in PACG in response to topical application of latanoprost.


Assuntos
Anti-Hipertensivos/farmacologia , Cães , Olho/efeitos dos fármacos , Prostaglandinas F Sintéticas/farmacologia , Administração Tópica , Animais , Anti-Hipertensivos/administração & dosagem , Feminino , Latanoprosta , Prostaglandinas F Sintéticas/administração & dosagem
7.
J Ocul Pharmacol Ther ; 39(9): 611-621, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37643299

RESUMO

Purpose: Dry eye disease is attributed to impaired tear production and/or evaporative dry eye. Evaporative dry eye is frequently associated with meibomian gland dysfunction (MGD). The objective of this study was to identify clinical study endpoints related to MGD. Methods: This 22-day, noninterventional, case-control clinical study involved three cohorts with increasing MGD severity: no MGD, mild/moderate MGD, and severe MGD. Symptoms were assessed with an ocular symptom questionnaire grading blurred vision, eye burning, eye dryness, eye pain, light sensitivity, eye itching, eye foreign body sensation, and overall ocular discomfort. Sign assessments included the maximum meibum quality score (MMQS), tear breakup time, Schirmer tear tests, biomicroscopy, and corneal staining. Signs and symptoms were compared between cohorts and study visits. Results: Seventy-five study participants were assigned to the cohorts (25 per cohort). MMQS scores increased with increasing MGD severity, reflecting the selection criteria for the cohorts. Between-visit scores showed a weighted kappa statistic of 0.72 indicating substantial agreement. Mean scores of all assessed symptoms increased with increasing MGD severity. Scores for symptoms showed moderate (κ = 0.41-0.60) to substantial (κ = 0.61-0.80) agreement between visits. Overall ocular discomfort demonstrated the strongest correlation with the MMQS. Conclusion: The MMQS was a reproducible sign of MGD showing good agreement with ocular symptoms. Overall ocular discomfort was well correlated with typical dry eye symptoms and could potentially be used as a single measure of MGD symptoms. The findings from this observational study may inform endpoints for future clinical trials. ClinicalTrials.gov NCT01979887.


Assuntos
Síndromes do Olho Seco , Doenças Palpebrais , Disfunção da Glândula Tarsal , Humanos , Disfunção da Glândula Tarsal/diagnóstico , Glândulas Tarsais , Doenças Palpebrais/diagnóstico , Lágrimas
8.
Invest Ophthalmol Vis Sci ; 64(3): 15, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36877514

RESUMO

Purpose: The purpose of this study was to evaluate the effects of pharmacologically relevant bimatoprost and bimatoprost free acid (BFA) concentrations on matrix metalloproteinase (MMP) gene expression in cells from human aqueous outflow tissues. Methods: MMP gene expression by human trabecular meshwork (TM), scleral fibroblast (SF), and ciliary muscle (CM) cells exposed to 10 to 1000 µM bimatoprost or 0.1 to 10 µM BFA (intraocular concentrations after intracameral bimatoprost implant and topical bimatoprost dosing, respectively) was measured by polymerase chain reaction array. Results: Bimatoprost dose-dependently upregulated MMP1 and MMP14 mRNA in all cell types and MMP10 and MMP11 mRNA in TM and CM cells; in TM cells from normal eyes, mean MMP1 mRNA levels were 62.9-fold control levels at 1000 µM bimatoprost. BFA upregulated MMP1 mRNA only in TM and SF cells, to two- to three-fold control levels. The largest changes in extracellular matrix (ECM)-related gene expression by TM cells derived from normal (n = 6) or primary open-angle glaucoma (n = 3) eyes occurred with 1000 µM bimatoprost (statistically significant, ≥50% change for 9-11 of 84 genes on the array, versus 1 gene with 10 µM BFA). Conclusions: Bimatoprost and BFA had differential effects on MMP/ECM gene expression. Dramatic upregulation in MMP1 and downregulation of fibronectin, which occurred only with bimatoprost at high concentrations observed in bimatoprost implant-treated eyes, may promote sustained outflow tissue remodeling and long-term intraocular pressure reduction beyond the duration of intraocular drug bioavailability. Variability in bimatoprost-stimulated MMP upregulation among cell strains from different donors may help explain differential long-term responses of patients to bimatoprost implant.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Humanos , Metaloproteinase 1 da Matriz/genética , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma de Ângulo Aberto/cirurgia , Tonometria Ocular , Esclera , Bimatoprost/farmacologia
9.
Invest Ophthalmol Vis Sci ; 64(10): 22, 2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-37466951

RESUMO

Purpose: Information on the relationship between meibum lipid composition and severity of meibomian gland dysfunction (MGD) is limited. The purpose of this study was to analyze the molecular components of meibum collected from individuals with no MGD, mild-to-moderate MGD, and severe MGD. Methods: Adults with and without MGD were enrolled in a prospective, multicenter, exploratory clinical trial (ClinicalTrials.gov Identifier: NCT01979887). Molar ratios of cholesteryl ester to wax ester (RCE/WE) and aldehyde to wax ester (Rald/WE) in meibum samples were measured with 1H-NMR spectroscopy. Results were evaluated for participants grouped by MGD disease status and severity (non-MGD, mild-to-moderate MGD, and severe MGD), as defined by maximum meibum quality scores, Schirmer test results, and Subject Ocular Symptom Questionnaire responses. Results: Sixty-nine meibum samples from 69 individuals were included in the analysis: 24 non-MGD, 24 mild-to-moderate MGD, and 21 severe MGD. Mean RCE/WE was 0.29 in non-MGD, 0.14 in mild-to-moderate MGD (P = 0.038 vs. non-MGD, 51% lower), and 0.07 in severe MGD (P = 0.16 vs. mild-to-moderate MGD, 52% lower; P = 0.002 vs. non-MGD, 76% lower). Mean Rald/WE was 0.00022 in non-MGD, 0.00083 in mild-to-moderate MGD (P = 0.07 vs. non-MGD, 277% higher), and 0.0024 in severe MGD (P = 0.003 vs. mild-to-moderate MGD, 190% higher; P < 0.001 vs. non-MGD, 992% higher). Conclusions: RCE/WE was lowest and Rald/WE was highest in the severe MGD cohort, suggesting that these meibum constituent molar ratios may result from the pathophysiology associated with MGD and can impact ocular surface lipid and tear film homeostasis. These findings may potentially help identify targets for MGD treatment.


Assuntos
Doenças Palpebrais , Disfunção da Glândula Tarsal , Adulto , Humanos , Disfunção da Glândula Tarsal/diagnóstico , Lágrimas/química , Estudos Prospectivos , Glândulas Tarsais , Ésteres do Colesterol
10.
J Ocul Pharmacol Ther ; 39(1): 55-62, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36378864

RESUMO

Purpose: To evaluate the time course of biodegradation of an intracameral, biodegradable, sustained-release bimatoprost implant that lowers intraocular pressure without the need for daily eye drops. Methods: In 2 identically designed, randomized, phase 3 clinical trials, adults with open-angle glaucoma or ocular hypertension and open iridocorneal angles inferiorly in the study eye were administered 10- or 15-µg bimatoprost implant (day 1 and weeks 16 and 32) or twice-daily topical timolol 0.5%. Implants were assessed on gonioscopy throughout the studies. Investigators reported whether implants were visible, estimated the size of visible implants relative to their initial size at implantation, and reported the implant location. Data for 10-µg implant placed on day 1 were pooled from both studies for analysis. Results: A total of 372 patients received the 10-µg bimatoprost implant. The degree of implant biodegradation at each follow-up time point was variable among patients. The implant frequently swelled during the initial phase of biodegradation from 6 to 28 weeks. Accelerated biodegradation occurred between 31 and 52 weeks, resulting in 82% of implants absent or ≤25% of initial size by 52 weeks. By month 20, 95% of implants had biodegraded to absent or ≤25% of initial size. The implant was predominantly located inferiorly in the iridocorneal angle. Conclusions: Bimatoprost implant biodegradation in phase 3 studies showed some degree of variability among patients. Clinically significant implant biodegradation was observed in the majority of patients by 12 months. Clinical studies are in progress to further understand implant biodegradation and the ideal timing for implant re-administration. ClinicalTrials.gov NCT02247804; ClinicalTrials.gov NCT02250651.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Hipertensão Ocular , Adulto , Humanos , Amidas/uso terapêutico , Anti-Hipertensivos/uso terapêutico , Bimatoprost/uso terapêutico , Cloprostenol/uso terapêutico , Glaucoma/tratamento farmacológico , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Hipertensão Ocular/tratamento farmacológico , Timolol/uso terapêutico
11.
Am J Ophthalmol ; 253: 189-200, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37149245

RESUMO

PURPOSE: To evaluate the safety, efficacy, and pharmacokinetics of pilocarpine hydrochloride 1.25% (Pilo hereafter) compared with vehicle when administered bilaterally, twice daily (6 hours apart) for 14 days in participants with presbyopia. DESIGN: Phase 3, randomized (1:1), controlled, double-masked, multicenter study. METHODS: Participants (40-55 years of age) had objective and subjective evidence of presbyopia affecting daily activities with mesopic, high-contrast, binocular distance-corrected near visual acuity (DCNVA) of 20/40 to 20/100. The primary/key secondary endpoint was the proportion of participants gaining ≥3 lines in mesopic/photopic, high-contrast, binocular DCNVA on day 14 (last study visit), hour 9 (3 hours after the second dose), with no more than a 5-letter loss in mesopic/photopic corrected distance visual acuity with the same refractive correction. Key safety measures included treatment-emergent adverse events (TEAEs) and some ocular measurements. Pilocarpine plasma levels were assessed in approximately 10% of enrolled participants. RESULTS: Overall, 230 participants were randomized to Pilo twice daily (N = 114) and vehicle (N = 116). The proportion of participants achieving the primary and key secondary efficacy endpoints was statistically significantly greater with Pilo twice daily than vehicle, with between-treatment differences of 27.3% (95% CI = 17.3, 37.4) and 26.4% (95% CI = 16.8, 36.0), respectively. The most common TEAE was headache, reported in 10 participants (8.8%, Pilo group) and 4 participants (3.4%, vehicle group). Pilocarpine's accumulation index on day 14 was ≤1.11 after the second dose. CONCLUSIONS: Near-vision improvements were statistically greater with Pilo twice daily than with vehicle, without compromising distance acuity. The safety profile of Pilo twice daily was consistent with that of Pilo once daily, and systemic accumulation was minimal, supporting twice daily administration.


Assuntos
Pilocarpina , Presbiopia , Humanos , Presbiopia/tratamento farmacológico , Acuidade Visual , Refração Ocular , Método Duplo-Cego
12.
Vet Ophthalmol ; 15 Suppl 1: 71-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22129101

RESUMO

INTRODUCTION: Episcleral venous pressure (EVP) has an important role in intraocular pressure (IOP) homeostasis and accounts for more than 70% of the IOP in the normal dog. A frequently used species in glaucoma research is the normotensive dog especially when evaluating the efficacy of prostaglandin analogues and prostamides; however, aqueous humor dynamic studies in normal dogs are lacking, and the effect of 0.005% latanoprost on canine EVP is not known. We sought to determine the effects to the EVP of topically applied 0.005% latanoprost in the normotensive beagle dog. METHODS: Female beagle dogs (n = 14) were used and each had a normal ophthalmic examination on study entry. EVP was determined using a standard episcleral venomanometer. Animals were dosed in one eye with 0.005% latanoprost, and the effects on EVP were compared with the averaged baseline EVP's determined in the predosing phase and the fellow nondosed eye. The Mixed Model Repeated Measures method was used to analyze the EVP data. RESULTS: During the dosing phase of the study with topical 0.005% latanoprost, the mean EVPs of dosed eyes were significantly higher than that of nondosed eyes (P < 0.0001). CONCLUSIONS: The increase in EVP in the dog with exposure to topical 0.005% latanoprost has not been observed in other species that have been studied, such as in the mouse and in humans, where the drug had no significant effect on the EVP. This response may be unique to dogs and suggests that dogs may not fully mimic human aqueous humor dynamics with topical 0.005% latanoprost. Although frequently performed in human studies, EVP should not be regarded to be a constant value in aqueous humor dynamic studies in the normal beagle dog.


Assuntos
Pressão Sanguínea/efeitos dos fármacos , Cães , Prostaglandinas F Sintéticas/administração & dosagem , Prostaglandinas F Sintéticas/farmacologia , Esclera/irrigação sanguínea , Administração Tópica , Animais , Anti-Hipertensivos/administração & dosagem , Anti-Hipertensivos/farmacologia , Feminino , Latanoprosta , Esclera/efeitos dos fármacos
13.
Vet Ophthalmol ; 15 Suppl 1: 60-3, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22050644

RESUMO

OBJECTIVE: Female dogs have approximately twice the risk of males for developing primary angle closure glaucoma (PACG). The cause of this gender difference is unknown, but one theory proposes that the gender differences in iridocorneal angle morphology are involved in this risk differential. PROCEDURES: Fifty beagles (25 males, 25 females) were included into this study and had normal baseline ophthalmic examinations. Normal dogs were selected so as to avoid any potentially confounding influence of goniodysgenesis. Standardized 20-MHz high-resolution ultrasound images of the iridocorneal angle were acquired from one eye of each dog with the scan plane perpendicular to the limbus in the superior temporal quadrant. Images were imported into ImageJ, and the angle opening distance (AOD) and angle recess area (ARA) were measured by a masked observer, and the analysis of variance method was used to compare differences. RESULTS: The mean (±SD) AOD was significantly smaller for female dogs (0.847 ± 0.241 mm) vs. male dogs (1.058 ± 0.322 mm) P-value = 0.012. The mean (± SD) ARA tended to be smaller for female dogs (0.584 ± 0.278 mm) vs. male dogs (0.748 ± 0.385 mm), but this difference was not significant (P-value = 0.092). CONCLUSIONS: Female dogs have a significantly smaller AOD vs. males. This difference may render the female iridocorneal angle more susceptible to closure and may partially explain the 2:1 female/male predisposition to PACG. Further studies using goniodysgenic dogs are warranted.


Assuntos
Córnea/anatomia & histologia , Doenças do Cão/patologia , Glaucoma de Ângulo Fechado/veterinária , Iris/anatomia & histologia , Animais , Biometria , Cães , Feminino , Glaucoma de Ângulo Fechado/patologia , Gonioscopia/veterinária , Masculino
14.
J Ocul Pharmacol Ther ; 38(4): 311-318, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35442770

RESUMO

Purpose: To assess the intraocular pressure (IOP)-lowering effect of a biodegradable bimatoprost implant following selective laser trabeculoplasty (SLT) in a canine model. Methods: Unilateral SLT was performed in 11 normotensive, treatment-naive beagle dogs. IOP was measured at baseline (pre-SLT) and weekly post-SLT (≤10 weeks). After IOP returned to baseline or at 10 weeks (whichever occurred first), a sustained-release bimatoprost implant was administered bilaterally in the anterior chamber of each animal. IOP was measured weekly for 4 weeks and then every 2 weeks up to week 42. Results: The main outcomes included the IOP change (%) from baseline, calculated in both eyes in the overall population, SLT responder subgroup (defined by peak IOP reduction from baseline ≥3 mmHg or ≥15% for >1 week post-SLT), and SLT nonresponder subgroup (defined by peak IOP reduction from baseline <3 mmHg or <15%). The bimatoprost implant lowered IOP similarly in both the SLT-treated and fellow SLT-naive eyes. Following bimatoprost implant administration, the mean (standard deviation [SD]) peak IOP reduction from baseline was 34.4% (8.5%) in SLT-treated eyes and 35.7% (5.9%) in fellow SLT-naive eyes. The bimatoprost implant lowered IOP comparably (P > 0.17) in eyes that responded to SLT (mean [SD] peak IOP reduction, 34.6% [10.7%]; n = 6) and those that did not (mean [SD] peak IOP reduction, 34.1% [6.1%]; n = 5). Conclusion: The bimatoprost implant effectively lowered IOP in eyes pretreated with SLT, regardless of response to SLT. The current data suggest that eyes previously treated with SLT can still benefit from the intracameral bimatoprost implant.


Assuntos
Terapia a Laser , Hipertensão Ocular , Trabeculectomia , Animais , Bimatoprost/farmacologia , Bimatoprost/uso terapêutico , Preparações de Ação Retardada , Cães , Pressão Intraocular , Lasers , Resultado do Tratamento
15.
JAMA Ophthalmol ; 140(4): 363-371, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35238902

RESUMO

IMPORTANCE: AGN-190584 (Allergan, an AbbVie company) is an optimized topical formulation of pilocarpine hydrochloride, 1.25%, designed for managing presbyopia and enhanced with a proprietary vehicle. OBJECTIVE: To evaluate the efficacy and safety of pilocarpine hydrochloride, 1.25%, in individuals with presbyopia. DESIGN, SETTING, AND PARTICIPANTS: This vehicle-controlled, participant- and investigator-masked, randomized, phase 3 clinical study, GEMINI 1, enrolled individuals with presbyopia, aged 40 to 55 years, at 36 sites in the United States from December 21, 2018, to October 31, 2019. Analysis took place between February 2020 and December 2021. INTERVENTIONS: AGN-190584 or the AGN-190584 formulation vehicle was administered bilaterally, once daily for 30 days. MAIN OUTCOMES AND MEASURES: The proportion of participants with improvement of 3 or more lines in mesopic, high-contrast, binocular distance-corrected near visual acuity (DCNVA) at hours 3 and 6 on day 30 were the primary and key secondary efficacy end points, respectively. Safety measures included adverse events. RESULTS: Of 323 participants who were randomized, 235 (72.8%) were female and 292 (90.4%) were White. The mean (SD) age was 49.6 (3.5) years, and the baseline mean (SD) mesopic DCNVA was 29.2 (6.3) letters. A total of 163 individuals were randomized to AGN-190584 and 160 were randomized to vehicle. GEMINI 1 met its primary and key secondary efficacy end points. On day 30, hour 3, the percentage of participants with improvement of 3 or more lines in mesopic DCNVA was 30.7% (50 of 163) in the AGN-190584 group and 8.1% (13 of 160) in the vehicle group (difference, 22.5% [95% CI, 14.3%-30.8%]; adjusted P < .001). At hour 6, those percentages were 18.4% (30 of 163) and 8.8% (14 of 160), respectively (difference, 9.7% [95% CI, 2.3%-17.0%]; adjusted P = .01). At hour 8, the between-group difference in 3 or more lines of mesopic DCNVA gains was not statistically significant, but clinically relevant prespecified outcome measures demonstrated AGN-190584 superiority to vehicle in least-squares mean (SE) mesopic DCNVA change from baseline at hour 8 (5.4 [0.51] vs 3.6 [0.52] letters; P = .009) and photopic distance-corrected intermediate visual acuity at hour 8 (3.9 [0.44] vs 2.4 [0.45] letters; P = .01) and hour 10 (3.5 [0.46] vs 1.7 [0.47] letters; P = .004). No participants with mesopic DCNVA improvement of 3 or more lines at hour 3 had losses of more than 5 letters in mesopic, high-contrast, binocular-corrected distance visual acuity. The onset of effect was at 15 minutes. AGN-190584 demonstrated an acceptable safety and tolerability profile. CONCLUSIONS AND RELEVANCE: AGN-190584 demonstrated superiority over vehicle in mesopic DCNVA on day 30, hours 3 and 6, with an acceptable safety profile. AGN-190584 is a safe and efficacious topical therapy for presbyopia through 30 days. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03804268.


Assuntos
Visão de Cores , Presbiopia , Feminino , Humanos , Masculino , Pilocarpina , Presbiopia/tratamento farmacológico , Resultado do Tratamento , Acuidade Visual
16.
Ophthalmol Ther ; 11(2): 869-879, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35235173

RESUMO

INTRODUCTION: Pilocarpine hydrochloride (pilo) ophthalmic solution has traditionally been used for the treatment of glaucoma, with opportunities to improve the tolerability profile experienced by patients. Pilocarpine hydrochloride ophthalmic solution 1.25% (Vuity™, Allergan, an AbbVie company) was approved in late 2021 for the treatment of adults with presbyopia. This publication describes the properties of the optimized, proprietary vehicle of this new ophthalmic solution developed with the aim of improving tolerability upon instillation. METHODS: An in vitro method determined the time required for the pH of pilo 1.25% in the proprietary vehicle (Optimized Formulation) and a commercially available 1% pilo ophthalmic solution (Generic Formulation) to equilibrate with the pH of simulated tear fluid (STF). In a pilot study, five of the six screened participants received one drop of the Optimized Formulation in one eye and Generic Formulation in the other. Ocular discomfort and vision blur were evaluated for each eye just prior to and at multiple times after drop instillation using visual analog scales (VAS), and adverse events were assessed. RESULTS: The in vitro method showed that the Optimized Formulation achieved faster pH equilibration than the Generic Formulation. The pilot study revealed that the Optimized Formulation demonstrated less ocular discomfort, vision blur, and adverse events compared to the Generic. CONCLUSION: The in vitro and pilot study of the Optimized Formulation indicated that it rapidly equilibrates to the physiologic pH of the tear film, providing greater comfort and tolerability while also minimizing vision blur. Overall, the proprietary vehicle is expected to improve comfort, result in less vision blur, and provide a well-tolerated alternative method to deliver pilo for the treatment of presbyopia when compared to what is commercially available.

17.
Ophthalmol Sci ; 1(4): 100065, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36246939

RESUMO

Purpose: To determine the safety, efficacy, and tolerability of combinations of pilocarpine (Pilo) and oxymetazoline (Oxy) ocular drops dosed once daily and identify the optimal concentration of each for the pharmacologic treatment of presbyopia. Design: Two concurrent Phase 2, multicenter, double-masked, randomized, vehicle-controlled studies, 1 short-term and 1 extended study. Participants: Emmetropic individuals affected by presbyopia and in good general health. Methods: Uncorrected near visual acuity (UNVA) was measured throughout both studies with various concentrations and combinations of Pilo (0%, 0.5% 1.0%, and 1.5%) and Oxy (0%, 0.0125%, 0.05%, and 0.125%). For safety, uncorrected distance visual acuity (UDVA) was measured, treatment-emergent adverse events (TEAEs) were recorded, and a temporal/supraorbital headache assessment was completed. Main Outcome Measures: The primary efficacy end point was mean change from baseline in UNVA. Results: In the short-term study, Pilo was shown to produce a significant dose response in the average increase of letters (P < 0.001), whereas Oxy did not have a significant impact (P = 0.4797). The addition or increase in concentration of Oxy did not reduce incidence or severity of headaches when compared with Pilo alone. Efficacy results from the extended study supported the results from the short-term study. As early as 15 minutes postadministration, a dose response could be seen, with peak effect at 1 hour. Peak improvement increased from day 1 to day 14 and was maintained up to day 28. The most common TEAE was headache. There was no clinically significant reduction in UDVA. A polynomial regression model was developed and determined that the optimal concentration range of Pilo is between 1.16% and 1.32%. Conclusions: On the basis of the results of the 2 Phase 2 studies, AGN-190584, a reading drop containing an optimized concentration of pilocarpine HCl (1.25%) delivered using a proprietary formulation, was developed and is currently under investigation in Phase 3 studies.

18.
Drugs ; 81(17): 2017-2033, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34724172

RESUMO

OBJECTIVE: To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of 10 and 15 µg bimatoprost implant in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). METHODS: This randomized, 20-month, multicenter, masked, parallel-group, phase 3 trial enrolled 528 patients with OAG or OHT and an open iridocorneal angle inferiorly in the study eye. Study eyes were administered 10 or 15 µg bimatoprost implant on day 1, week 16, and week 32, or twice-daily topical timolol maleate 0.5%. Primary endpoints were IOP and IOP change from baseline through week 12. Safety measures included treatment-emergent adverse events (TEAEs) and corneal endothelial cell density (CECD). RESULTS: Both 10 and 15 µg bimatoprost implant met the primary endpoint of noninferiority to timolol in IOP lowering through 12 weeks. Mean IOP reductions from baseline ranged from 6.2-7.4, 6.5-7.8, and 6.1-6.7 mmHg through week 12 in the 10 µg implant, 15 µg implant, and timolol groups, respectively. IOP lowering was similar after the second and third implant administrations. Probabilities of requiring no IOP-lowering treatment for 1 year after the third administration were 77.5% (10 µg implant) and 79.0% (15 µg implant). The most common TEAE was conjunctival hyperemia, typically temporally associated with the administration procedure. Corneal TEAEs of interest (primarily corneal endothelial cell loss, corneal edema, and corneal touch) were more frequent with the 15 than the 10 µg implant and generally were reported after repeated administrations. Loss in mean CECD from baseline to month 20 was ~ 5% in 10 µg implant-treated eyes and ~ 1% in topical timolol-treated eyes. Visual field progression (change in the mean deviation from baseline) was reduced in the 10 µg implant group compared with the timolol group. CONCLUSIONS: The results corroborated the previous phase 3 study of the bimatoprost implant. The bimatoprost implant met the primary endpoint and effectively lowered IOP. The majority of patients required no additional treatment for 12 months after the third administration. The benefit-risk assessment favored the 10 over the 15 µg implant. Studies evaluating other administration regimens with reduced risk of corneal events are ongoing. The bimatoprost implant has the potential to improve adherence and reduce treatment burden in glaucoma. CLINICALTRIALS. GOV IDENTIFIER: NCT02250651.


Assuntos
Anti-Hipertensivos/uso terapêutico , Bimatoprost/uso terapêutico , Implantes de Medicamento/uso terapêutico , Glaucoma de Ângulo Aberto/tratamento farmacológico , Hipertensão Ocular/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/administração & dosagem , Anti-Hipertensivos/efeitos adversos , Bimatoprost/administração & dosagem , Bimatoprost/efeitos adversos , Relação Dose-Resposta a Droga , Método Duplo-Cego , Implantes de Medicamento/administração & dosagem , Implantes de Medicamento/efeitos adversos , Feminino , Humanos , Pressão Intraocular/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Timolol/uso terapêutico , Adulto Jovem
19.
Pharm Res ; 27(10): 2043-53, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20535532

RESUMO

The safety and effectiveness of systemic and topical medical therapies for ocular disorders are limited due to poor ocular drug uptake, nonspecificity to target tissues, systemic side effects, and poor adherence to therapy. Intravitreal injections can enhance ocular drug delivery, but the need for frequent retreatment and potential injection-related side effects limit the utility of this technique. Sustained-release drug delivery systems have been developed to overcome these limitations; such systems can achieve prolonged therapeutic drug concentrations in ocular target tissues while limiting systemic exposure and side effects and improving patient adherence to therapy. A critical factor in the development of safe and effective drug delivery systems has been the development of biocompatible polymers, which offer the versatility to tailor drug release kinetics for specific drugs and ocular diseases. Ocular implants include nonbiodegradable and biodegradable designs, with the latter offering several advantages. The polymers most commonly used in biodegradable delivery systems are synthetic aliphatic polyesters of the poly-α-hydroxy acid family including polylactic acid, polyglycolic acid, and polylactic-co-glycolic acid. The characteristics of these polymers for medical applications as well as the pharmacological properties, safety, and clinical effectiveness of biodegradable drug implants for the treatment of ocular diseases are reviewed herein.


Assuntos
Implantes Absorvíveis , Sistemas de Liberação de Medicamentos/métodos , Oftalmopatias/tratamento farmacológico , Implantes Absorvíveis/efeitos adversos , Animais , Preparações de Ação Retardada/administração & dosagem , Portadores de Fármacos/efeitos adversos , Portadores de Fármacos/química , Sistemas de Liberação de Medicamentos/instrumentação , Humanos , Polímeros/efeitos adversos , Polímeros/química
20.
Transl Vis Sci Technol ; 9(4): 20, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32818107

RESUMO

Purpose: To assess the pharmacokinetic (PK)/pharmacodynamic (PD) relationship following intracameral Bimatoprost sustained-release (SR) implants (8, 15, 30, and 60 µg) in dogs to determine the optimal investigative dose in humans. Methods: Forty-four male normotensive beagle dogs were assigned to 1 of 8 groups receiving 8-, 15-, 30-, and 60-µg implants (PD assessment [n = 8/group, 4 groups]; PK assessment [n = 3/group, 4 groups]). Intraocular pressure (IOP) in PD animals and aqueous humor/blood concentrations of bimatoprost and its acid in PK animals were assessed. PK/PD correlation analysis was performed using steady-state data. Residual implants were recovered to assess polymer degradation. Results: Dose-dependent IOP lowering was observed for all dose groups for at least 3 months postdose. Blood concentrations of bimatoprost and bimatoprost acid were below the limit of quantification (<0.25 ng/mL), whereas dose-dependent concentration-time profiles were observed in the aqueous humor. At steady state, observed and predicted correlation between aqueous humor drug concentration and IOP lowering was similar and translatable to findings in humans following topical bimatoprost eyedrop administration. Implants at all doses were well tolerated and polymer degradation was apparent. Conclusions: Dose-dependent IOP lowering with Bimatoprost SR was maintained for at least 3 months in dogs, and the implants were well tolerated. The established PK/PD relationship appears to translate to humans. Doses between 8 and 15 µg appear to provide the best benefit/risk profile for clinical development of the implants. Translational Relevance: The close PK/PD relationship between dog and human helps inform which bimatoprost dose should be investigated in clinical studies.


Assuntos
Anti-Hipertensivos , Pressão Intraocular , Animais , Humor Aquoso , Bimatoprost , Preparações de Ação Retardada , Cães , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA