Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Breast Cancer Res ; 22(1): 29, 2020 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-32169100

RESUMO

BACKGROUND: Breast cancer patients with early-stage disease are increasingly administered neoadjuvant chemotherapy (NAC) to downstage their tumors prior to surgery. In this setting, approximately 31% of patients fail to respond to therapy. This demonstrates the need for techniques capable of providing personalized feedback about treatment response at the earliest stages of therapy to identify patients likely to benefit from changing treatment. Diffuse optical spectroscopic imaging (DOSI) has emerged as a promising functional imaging technique for NAC monitoring. DOSI uses non-ionizing near-infrared light to provide non-invasive measures of absolute concentrations of tissue chromophores such as oxyhemoglobin. In 2011, we reported a new DOSI prognostic marker, oxyhemoglobin flare: a transient increase in oxyhemoglobin capable of discriminating NAC responders within the first day of treatment. In this follow-up study, DOSI was used to confirm the presence of the flare as well as to investigate whether DOSI markers of NAC response are regimen dependent. METHODS: This dual-center study examined 54 breast tumors receiving NAC measured with DOSI before therapy and the first week following chemotherapy administration. Patients were treated with either a standard of care maximum tolerated dose (MTD) regimen or an investigational metronomic (MET) regimen. Changes in tumor chromophores were tracked throughout the first week and compared to pathologic response and treatment regimen at specific days utilizing generalized estimating equations (GEE). RESULTS: Within patients receiving MTD therapy, the oxyhemoglobin flare was confirmed as a prognostic DOSI marker for response appearing as soon as day 1 with post hoc GEE analysis demonstrating a difference of 48.77% between responders and non-responders (p < 0.0001). Flare was not observed in patients receiving MET therapy. Within all responding patients, the specific treatment was a significant predictor of day 1 changes in oxyhemoglobin, showing a difference of 39.45% (p = 0.0010) between patients receiving MTD and MET regimens. CONCLUSIONS: DOSI optical biomarkers are differentially sensitive to MTD and MET regimens at early timepoints suggesting the specific treatment regimen should be considered in future DOSI studies. Additionally, DOSI may help to identify regimen-specific responses in a more personalized manner, potentially providing critical feedback necessary to implement adaptive changes to the treatment strategy.


Assuntos
Antineoplásicos/uso terapêutico , Neoplasias da Mama/patologia , Hemodinâmica/efeitos dos fármacos , Terapia Neoadjuvante/métodos , Imagem Óptica/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Administração Metronômica , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Feminino , Humanos , Dose Máxima Tolerável , Pessoa de Meia-Idade , Resultado do Tratamento
2.
Opt Lett ; 43(4): 747-750, 2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-29444068

RESUMO

Frequency-domain diffuse optical spectroscopy (FD-DOS) is an established technique capable of determining optical properties and chromophore concentrations in biological tissue. Most FD-DOS systems use either manually positioned, handheld probes or complex arrays of source and detector fibers to acquire data from many tissue locations, allowing for the generation of 2D or 3D maps of tissue. Here, we present a new method to rapidly acquire a wide range of source-detector (SD) separations by mechanically scanning a single SD pair. The source and detector fibers are mounted on a scan head that traces a hypotrochoidal pattern over the sample that, when coupled with a high-speed FD-DOS system, enables the rapid collection of dozens of SD separations for depth-resolved imaging. We demonstrate that this system has an average error of 4±2.6% in absorption and 2±1.8% in scattering across all SD separations. Additionally, by linearly translating the device, the size and location of an absorbing inhomogeneity can be determined through the generation of B-scan images in a manner conceptually analogous to ultrasound imaging. This work demonstrates the potential of single optode diffuse optical scanning for depth resolved visualization of heterogeneous biological tissues at near real-time rates.


Assuntos
Dispositivos Ópticos , Análise Espectral/instrumentação , Imagens de Fantasmas
3.
Opt Lett ; 43(22): 5669-5672, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30439924

RESUMO

Spatial frequency domain imaging (SFDI) is emerging as an important new method in biomedical imaging due to its ability to provide label-free, wide-field tissue optical property maps. Most prior SFDI studies have utilized two spatial frequencies (2-fx) for optical property extractions. The use of more than two frequencies (multi-fx) can vastly improve the accuracy and reduce uncertainties in optical property estimates for some tissue types, but it has been limited in practice due to the slow speed of available inversion algorithms. We present a deep learning solution that eliminates this bottleneck by solving the multi-fx inverse problem 300× to 100,000× faster, with equivalent or improved accuracy compared to competing methods. The proposed deep learning inverse model will help to enable real-time and highly accurate tissue measurements with SFDI.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Imagem Óptica , Imagens de Fantasmas
4.
Proc Natl Acad Sci U S A ; 108(35): 14626-31, 2011 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-21852577

RESUMO

Approximately 8-20% of breast cancer patients receiving neoadjuvant chemotherapy fail to achieve a measurable response and endure toxic side effects without benefit. Most clinical and imaging measures of response are obtained several weeks after the start of therapy. Here, we report that functional hemodynamic and metabolic information acquired using a noninvasive optical imaging method on the first day after neoadjuvant chemotherapy treatment can discriminate nonresponding from responding patients. Diffuse optical spectroscopic imaging was used to measure absolute concentrations of oxyhemoglobin, deoxyhemoglobin, water, and lipid in tumor and normal breast tissue of 24 tumors in 23 patients with untreated primary breast cancer. Measurements were made before chemotherapy, on day 1 after the first infusion, and frequently during the first week of therapy. Various multidrug, multicycle regimens were used to treat patients. Diffuse optical spectroscopic imaging measurements were compared with final postsurgical pathologic response. A statistically significant increase, or flare, in oxyhemoglobin was observed in partial responding (n = 11) and pathologic complete responding tumors (n = 8) on day 1, whereas nonresponders (n = 5) showed no flare and a subsequent decrease in oxyhemoglobin on day 1. Oxyhemoglobin flare on day 1 was adequate to discriminate nonresponding tumors from responding tumors. Very early measures of chemotherapy response are clinically convenient and offer the potential to alter treatment strategies, resulting in improved patient outcomes.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Oxiemoglobinas/análise , Neoplasias da Mama/sangue , Quimioterapia Adjuvante , Feminino , Humanos , Terapia Neoadjuvante
5.
Biomed Opt Express ; 15(8): 4963-4979, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39346994

RESUMO

Frequency-domain diffuse optical spectroscopy (FD-DOS) is a powerful non-invasive technique for assessing tissue optical properties, with applications ranging from basic research to clinical diagnosis. In this study, we introduce and validate a novel approach termed the cross-wavelength calibrating (CWC) method within the framework of TrackDOSI, a real-time FD-DOS imaging system for tissue characterization. The CWC method aims to mitigate the effects of changing optical coupling and motion artifacts encountered during probe scanning, thus enhancing the accuracy and reliability of optical property measurements. Notably, the CWC method also allows for a simpler geometry with fewer sources than traditional self-calibrating (SC) methods, reducing instrumental complexity and cost while maintaining robustness in estimating optical properties. We first validate the CWC method on solid silicone phantoms, demonstrating strong agreement with the gold standard SC method with an error of -10% and 1% for absorption and reduced scattering coefficients, respectively. Furthermore, experiments on phantom and human tissue reveal the CWC approach's ability to suppress motion artifacts and optical coupling variations, thereby improving measurement repeatability, signal fidelity, and artifact correction in dynamic imaging scenarios. Our findings underscore the potential of the CWC method to enhance the clinical utility of DOSI techniques by enabling real-time artifact correction and improving the accuracy of tissue optical property measurements.

6.
J Biomed Opt ; 29(3): 035002, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38532926

RESUMO

Significance: Mechanical ventilation (MV) is a cornerstone technology in the intensive care unit as it assists with the delivery of oxygen in critically ill patients. The process of weaning patients from MV can be long and arduous and can lead to serious complications for many patients. Despite the known importance of inspiratory muscle function in the success of weaning, current clinical standards do not include direct monitoring of these muscles. Aim: The goal of this project was to develop and validate a combined frequency domain near-infrared spectroscopy (FD-NIRS) and diffuse correlation spectroscopy (DCS) system for the noninvasive characterization of inspiratory muscle response to a load. Approach: The system was fabricated by combining a custom digital FD-NIRS and DCS system. It was validated via liquid phantom titrations and a healthy volunteer study. The sternocleidomastoid (SCM), an accessory muscle of inspiration, was monitored during a short loading period in fourteen young, healthy volunteers. Volunteers performed two different respiratory exercises, a moderate load and a high load, which consisted of a one-minute baseline, a one-minute load, and a six-minute recovery period. Results: The system has low crosstalk between absorption, reduced scattering, and flow when tested in a set of liquid titrations. Faster dynamics were observed for changes in blood flow index (BFi), and metabolic rate of oxygen (MRO2) compared with hemoglobin + myoglobin (Hb+Mb) based parameters after the onset of loads in males. Additionally, larger percent changes in BFi, and MRO2 were observed compared with Hb+Mb parameters in both males and females. There were also sex differences in baseline values of oxygenated Hb+Mb, total Hb+Mb, and tissue saturation. Conclusions: The dynamic characteristics of Hb+Mb concentration and blood flow were distinct during loading of the SCM, suggesting that the combination of FD-NIRS and DCS may provide a more complete picture of inspiratory muscle dynamics.


Assuntos
Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Masculino , Feminino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Hemoglobinas/análise , Oxiemoglobinas/metabolismo , Consumo de Oxigênio/fisiologia , Músculos/química , Músculo Esquelético/fisiologia
7.
J Biomed Opt ; 29(6): 060801, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38864093

RESUMO

Significance: The estimation of tissue optical properties using diffuse optics has found a range of applications in disease detection, therapy monitoring, and general health care. Biomarkers derived from the estimated optical absorption and scattering coefficients can reflect the underlying progression of many biological processes in tissues. Aim: Complex light-tissue interactions make it challenging to disentangle the absorption and scattering coefficients, so dedicated measurement systems are required. We aim to help readers understand the measurement principles and practical considerations needed when choosing between different estimation methods based on diffuse optics. Approach: The estimation methods can be categorized as: steady state, time domain, time frequency domain (FD), spatial domain, and spatial FD. The experimental measurements are coupled with models of light-tissue interactions, which enable inverse solutions for the absorption and scattering coefficients from the measured tissue reflectance and/or transmittance. Results: The estimation of tissue optical properties has been applied to characterize a variety of ex vivo and in vivo tissues, as well as tissue-mimicking phantoms. Choosing a specific estimation method for a certain application has to trade-off its advantages and limitations. Conclusion: Optical absorption and scattering property estimation is an increasingly important and accessible approach for medical diagnosis and health monitoring.


Assuntos
Imagens de Fantasmas , Espalhamento de Radiação , Humanos , Luz , Imagem Óptica/métodos , Animais , Absorção de Radiação , Algoritmos
8.
J Appl Physiol (1985) ; 137(2): 382-393, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38867669

RESUMO

Prior studies of muscle blood flow and muscle-specific oxygen consumption have required invasive injection of dye and magnetic resonance imaging, respectively. Such measures have limited utility for continuous monitoring of the respiratory muscles. Frequency-domain near-infrared spectroscopy and diffuse correlation spectroscopy (FD-NIRS & DCS) can provide continuous surrogate measures of blood flow index (BFi) and metabolic rate of oxygen consumption (MRO2). This study aimed to validate sternocleidomastoid FD-NIRS & DCS outcomes against electromyography (EMG) and mouth pressure (Pm) during incremental inspiratory threshold loading (ITL). Six female and six male healthy adults (means ± SD; 30 ± 7 yr, maximum inspiratory pressure 118 ± 61 cmH2O) performed incremental ITL starting at low loads (8 ± 2 cmH2O) followed by 50-g increments every 2 min until task failure. FD-NIRS & DCS continuously measured sternocleidomastoid oxygenated and deoxygenated hemoglobin + myoglobin (oxy/deoxy[Hb + Mb]), tissue saturation of oxygen (StO2), BFi, and MRO2. Ventilatory parameters including inspiratory Pm were also evaluated. Pm increased during incremental ITL (P < 0.05), reaching -47[-74 to -34] cmH2O (median [IQR: 25%-75%]) at task failure. Ventilatory parameters were constant throughout ITL (all P > 0.05). Sternocleidomastoid BFi and MRO2 increased from the start of the ITL (both P < 0.05). Deoxy[Hb + Mb] increased close to task failure, concomitantly with a constant increase in MRO2, and decreased StO2. Sternocleidomastoid deoxy[Hb + Mb], BFi, StO2, and MRO2 obtained during ITL via FD-NIRS & DCS correlated with sternocleidomastoid EMG (all P < 0.05). In healthy adults, FD-NIRS & DCS can provide continuous surrogate measures of respiratory BFi and MRO2. Increasing sternocleidomastoid oxygen consumption near task failure was associated with increased oxygen extraction and reduced tissue saturation.NEW & NOTEWORTHY This study introduces a novel approach, frequency-domain near-infrared spectroscopy and diffuse correlation spectroscopy (FD-NIRS & DCS), for noninvasive continuous monitoring of respiratory muscle blood flow and metabolic rate of oxygen consumption. Unlike prior methods involving invasive dye injection and magnetic resonance imaging, FD-NIRS & DCS offers the advantage of continuous measurement without the need for invasive procedures. It holds promise for advancing muscle physiology understanding and opens avenues for real-time monitoring of respiratory muscles.


Assuntos
Consumo de Oxigênio , Fluxo Sanguíneo Regional , Músculos Respiratórios , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Masculino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Consumo de Oxigênio/fisiologia , Feminino , Músculos Respiratórios/fisiologia , Músculos Respiratórios/metabolismo , Fluxo Sanguíneo Regional/fisiologia , Eletromiografia/métodos , Oxigênio/metabolismo , Adulto Jovem , Saturação de Oxigênio/fisiologia , Hemoglobinas/metabolismo
9.
Breast Cancer Res ; 15(1): R14, 2013 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-23433249

RESUMO

INTRODUCTION: In addition to being a risk factor for breast cancer, breast density has been hypothesized to be a surrogate biomarker for predicting response to endocrine-based chemotherapies. The purpose of this study was to evaluate whether a noninvasive bedside scanner based on diffuse optical spectroscopic imaging (DOSI) provides quantitative metrics to measure and track changes in breast tissue composition and density. To access a broad range of densities in a limited patient population, we performed optical measurements on the contralateral normal breast of patients before and during neoadjuvant chemotherapy (NAC). In this work, DOSI parameters, including tissue hemoglobin, water, and lipid concentrations, were obtained and correlated with magnetic resonance imaging (MRI)-measured fibroglandular tissue density. We evaluated how DOSI could be used to assess breast density while gaining new insight into the impact of chemotherapy on breast tissue. METHODS: This was a retrospective study of 28 volunteers undergoing NAC treatment for breast cancer. Both 3.0-T MRI and broadband DOSI (650 to 1,000 nm) were obtained from the contralateral normal breast before and during NAC. Longitudinal DOSI measurements were used to calculate breast tissue concentrations of oxygenated and deoxygenated hemoglobin, water, and lipid. These values were compared with MRI-measured fibroglandular density before and during therapy. RESULTS: Water (r = 0.843; P < 0.001), deoxyhemoglobin (r = 0.785; P = 0.003), and lipid (r = -0.707; P = 0.010) concentration measured with DOSI correlated strongly with MRI-measured density before therapy. Mean DOSI parameters differed significantly between pre- and postmenopausal subjects at baseline (water, P < 0.001; deoxyhemoglobin, P = 0.024; lipid, P = 0.006). During NAC treatment measured at about 90 days, significant reductions were observed in oxyhemoglobin for pre- (-20.0%; 95% confidence interval (CI), -32.7 to -7.4) and postmenopausal subjects (-20.1%; 95% CI, -31.4 to -8.8), and water concentration for premenopausal subjects (-11.9%; 95% CI, -17.1 to -6.7) compared with baseline. Lipid increased slightly in premenopausal subjects (3.8%; 95% CI, 1.1 to 6.5), and water increased slightly in postmenopausal subjects (4.4%; 95% CI, 0.1 to 8.6). Percentage change in water at the end of therapy compared with baseline correlated strongly with percentage change in MRI-measured density (r = 0.864; P = 0.012). CONCLUSIONS: DOSI functional measurements correlate with MRI fibroglandular density, both before therapy and during NAC. Although from a limited patient dataset, these results suggest that DOSI may provide new functional indices of density based on hemoglobin and water that could be used at the bedside to assess response to therapy and evaluate disease risk.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Glândulas Mamárias Humanas/anormalidades , Imagem Óptica , Adulto , Idoso , Densidade da Mama , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Pré-Menopausa , Radiografia , Estudos Retrospectivos
10.
J Biomed Opt ; 28(9): 094800, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37692561

RESUMO

The editorial introduces the JBO Special Section on Short Wave Infrared Techniques and Applications in Biomedical Optics.

11.
J Biomed Opt ; 28(6): 065002, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37305780

RESUMO

Significance: Blood lipid levels (i.e., triglycerides (TGs) and cholesterol) are a strong predictor of cardiovascular disease (CVD) risk. Current methods for measuring blood lipids require invasive blood draws and traditional lab testing, limiting their practicality for frequent monitoring. Optical measurements of lipoproteins, which carry TG and cholesterol in blood, may lead to simpler invasive or non-invasive methods for more frequent and rapid blood lipid measurements. Aim: To investigate the effect of lipoproteins on optical properties of blood before and after a high-fat meal (i.e., the pre- and post-prandial state). Approach: Simulations were performed using Mie theory to estimate lipoprotein scattering properties. A literature review was conducted to identify key simulation parameters including lipoprotein size distributions and number density. Experimental validation of ex-vivo blood samples was conducted using spatial frequency domain imaging. Results: Our results indicated that lipoproteins in blood, particularly very low-density lipoproteins and chylomicrons, are highly scattering in the visible and near-infrared wavelength region. Estimates of the increase in the reduced scattering coefficient (µs') of blood at 730 nm after a high-fat meal ranged from 4% for a healthy individual, to 15% for those with type 2 diabetes, to up to 64% for those suffering from hypertriglyceridemia. A reduction in blood scattering anisotropy (g) also occurred as a function of TG concentration increase. Conclusion: These findings lay the foundation for future research in the development of optical methods for invasive and non-invasive optical measure of blood lipoproteins, which could improve early detection and management of CVD risk.


Assuntos
Doenças Cardiovasculares , Diabetes Mellitus Tipo 2 , Humanos , Doenças Cardiovasculares/diagnóstico por imagem , Estudos de Viabilidade , Lipoproteínas , Anisotropia
12.
bioRxiv ; 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38076980

RESUMO

Significance: Mechanical ventilation (MV) is a cornerstone technology in the intensive care unit as it assists with the delivery of oxygen in critical ill patients. The process of weaning patients from MV can be long, and arduous and can lead to serious complications for many patients. Despite the known importance of inspiratory muscle function in the success of weaning, current clinical standards do not include direct monitoring of these muscles. Aim: The goal of this project was to develop and validate a combined frequency domain near infrared spectroscopy (FD-NIRS) and diffuse correlation spectroscopy (DCS) system for the noninvasive characterization of inspiratory muscle response to a load. Approach: The system was fabricated by combining a custom digital FD-NIRS and DCS system. It was validated via liquid phantom titrations and a healthy volunteer study. The sternocleidomastoid (SCM), an accessory muscle of inspiration, was monitored during a short loading period in fourteen young healthy volunteer. Volunteers performed two different respiratory exercises, a moderate and high load, which consisted of a one-minute baseline, a one-minute load, and a six-minute recovery period. Results: The system has low crosstalk between absorption, reduced scattering, and flow when tested in a set of liquid titrations. Faster dynamics were observed for changes in blood flow index (BFi), and metabolic rate of oxygen (MRO2) compared to hemoglobin + myoglobin (Hb+Mb) based parameters after the onset of loads in males. Additionally, larger percent changes in BFi, and MRO2 were observed compared to Hb+Mb parameters in both males and females. There were also sex differences in baseline values of oxygenated Hb+Mb, total Hb+Mb, and tissue saturation. Conclusion: The dynamic characteristics of Hb+Mb concentration and blood flow were distinct during loading of the SCM, suggesting that the combination of FD-NIRS and DCS may provide a more complete picture of inspiratory muscle dynamics.

13.
Biomed Opt Express ; 14(6): 2955-2968, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37342706

RESUMO

Systemic sclerosis (SSc) is an autoimmune disease characterized by the widespread deposition of excess collagen in the skin and internal organs, as well as vascular dysfunction. The current standard of care technique used to quantify the extent of skin fibrosis in SSc patients is the modified Rodnan skin score (mRSS), which is an assessment of skin thickness based on clinical palpation. Despite being considered the gold standard, mRSS testing requires a trained physician and suffers from high inter-observer variability. In this study, we evaluated the use of spatial frequency domain imaging (SFDI) as a more quantitative and reliable method for assessing skin fibrosis in SSc patients. SFDI is a wide-field and non-contact imaging technique that utilizes spatially modulated light to generate a map of optical properties in biological tissue. The SFDI data were collected at six measurement sites (left and right forearms, hands, and fingers) of eight control subjects and ten SSc patients. mRSS were assessed by a physician, and skin biopsies were collected from subject's forearms and used to assess for markers of skin fibrosis. Our results indicate that SFDI is sensitive to skin changes even at an early stage, as we found a significant difference in the measured optical scattering (µs') between healthy controls and SSc patients with a local mRSS score of zero (no appreciable skin fibrosis by gold standard). Furthermore, we found a strong correlation between the diffuse reflectance (Rd) at a spatial frequency of 0.2 mm-1 and the total mRSS between all subjects (Spearman correlation coefficient = -0.73, p-value < 0.0028), as well as high correlation with histology results. The healthy volunteer results show excellent inter- and intra-observer reliability (ICC > 0.8). Our results suggest that the measurement of tissue µs' and Rd at specific spatial frequencies and wavelengths can provide an objective and quantitative assessment of skin involvement in SSc patients, which could greatly improve the accuracy and efficiency of monitoring disease progression and evaluating drug efficacy.

14.
Sci Rep ; 13(1): 3624, 2023 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-36869092

RESUMO

Cancer cells are mechanically sensitive to physical properties of the microenvironment, which can affect downstream signaling to promote malignancy, in part through the modulation of metabolic pathways. Fluorescence Lifetime Imaging Microscopy (FLIM) can be used to measure the fluorescence lifetime of endogenous fluorophores, such as the metabolic co-factors NAD(P)H and FAD, in live samples. We used multiphoton FLIM to investigate the changes in cellular metabolism of 3D breast spheroids derived from MCF-10A and MD-MB-231 cell lines embedded in collagen with varying densities (1 vs. 4 mg/ml) over time (Day 0 vs. Day 3). MCF-10A spheroids demonstrated spatial gradients, with the cells closest to the spheroid edge exhibiting FLIM changes consistent with a shift towards oxidative phosphorylation (OXPHOS) while the spheroid core had changes consistent with a shift towards glycolysis. The MDA-MB-231 spheroids had a large shift consistent with increased OXPHOS with a more pronounced change at the higher collagen concentration. The MDA-MB-231 spheroids invaded into the collagen gel over time and cells that traveled the farthest had the largest changes consistent with a shift towards OXPHOS. Overall, these results suggest that the cells in contact with the extracellular matrix (ECM) and those that migrated the farthest had changes consistent with a metabolic shift towards OXPHOS. More generally, these results demonstrate the ability of multiphoton FLIM to characterize how spheroids metabolism and spatial metabolic gradients are modified by physical properties of the 3D ECM.


Assuntos
Neoplasias , Fosforilação Oxidativa , Microscopia de Fluorescência , Transdução de Sinais , Linhagem Celular , Matriz Extracelular , NAD
15.
Biomed Opt Express ; 14(4): 1594-1607, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37078049

RESUMO

Non-invasive continuous blood pressure monitoring remains elusive. There has been extensive research using the photoplethysmographic (PPG) waveform for blood pressure estimation, but improvements in accuracy are still needed before clinical use. Here we explored the use of an emerging technique, speckle contrast optical spectroscopy (SCOS), for blood pressure estimation. SCOS provides measurements of both blood volume changes (PPG) and blood flow index (BFi) changes during the cardiac cycle, and thus provides a richer set of parameters compared to traditional PPG. SCOS measurements were taken on the finger and wrists of 13 subjects. We investigated the correlations between features extracted from both the PPG and BFi waveforms with blood pressure. Features from the BFi waveforms were more significantly correlated with blood pressure than PPG features ( R = - 0.55, p = 1.1 × 10-4 for the top BFi feature versus R = - 0.53, p = 8.4 × 10-4 for the top PPG feature). Importantly, we also found that features combining BFi and PPG data were highly correlated with changes in blood pressure ( R = - 0.59, p = 1.7 × 10-4 ). These results suggest that the incorporation of BFi measurements should be further explored as a means to improve blood pressure estimation using non-invasive optical techniques.

16.
Nat Biomed Eng ; 7(11): 1473-1492, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37640900

RESUMO

In cancer, solid stresses impede the delivery of therapeutics to tumours and the trafficking and tumour infiltration of immune cells. Understanding such consequences and the origin of solid stresses requires their probing in vivo at the cellular scale. Here we report a method for performing volumetric and longitudinal measurements of solid stresses in vivo, and findings from its applicability to tumours. We used multimodal intravital microscopy of fluorescently labelled polyacrylamide beads injected in breast tumours in mice as well as mathematical modelling to compare solid stresses at the single-cell and tissue scales, in primary and metastatic tumours, in vitro and in mice, and in live mice and post-mortem tissue. We found that solid-stress transmission is scale dependent, with tumour cells experiencing lower stresses than their embedding tissue, and that tumour cells in lung metastases experience substantially higher solid stresses than those in the primary tumours. The dependence of solid stresses on length scale and the microenvironment may inform the development of therapeutics that sensitize cancer cells to such mechanical forces.


Assuntos
Neoplasias Pulmonares , Camundongos , Animais , Microambiente Tumoral
17.
J Biomed Opt ; 28(9): 094808, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37313427

RESUMO

Significance: The shortwave infrared (SWIR, ∼900 to 2000 nm) holds promise for label-free measurements of water and lipid content in thick tissue, owed to the chromophore-specific absorption features and low scattering in this range. In vivo water and lipid estimations have potential applications including the monitoring of hydration, volume status, edema, body composition, weight loss, and cancer. To the best of our knowledge, there are currently no point-of-care or wearable devices available that exploit the SWIR wavelength range, limiting clinical and at-home translation of this technology. Aim: To design and fabricate a diffuse optical wearable SWIR probe for water and lipid quantification in tissue. Approach: Simulations were first performed to confirm the theoretical advantage of SWIR wavelengths over near infrared (NIR). The probe was then fabricated, consisting of light emitting diodes at three wavelengths (980, 1200, 1300 nm) and four source-detector (S-D) separations (7, 10, 13, 16 mm). In vitro validation was then performed on emulsion phantoms containing varying concentrations of water, lipid, and deuterium oxide (D2O). A deep neural network was developed as the inverse model for quantity estimation. Results: Simulations indicated that SWIR wavelengths could reduce theoretical water and lipid extraction errors from ∼6% to ∼1% when compared to NIR wavelengths. The SWIR probe had good signal-to-noise ratio (>32 dB up to 10 mm S-D) and low drift (<1.1% up to 10 mm S-D). Quantification error in emulsion phantoms was 2.1±1.1% for water and -1.2±1.5% for lipid. Water estimation during a D2O dilution experiment had an error of 3.1±3.7%. Conclusions: This diffuse optical SWIR probe was able to quantify water and lipid contents in vitro with good accuracy, opening the door to human investigations.


Assuntos
Aprendizado Profundo , Dispositivos Eletrônicos Vestíveis , Humanos , Emulsões , Água , Lipídeos
18.
J Biomed Opt ; 27(6)2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35715883

RESUMO

SIGNIFICANCE: The shortwave infrared (SWIR) optical window (∼900 to 2000 nm) has attracted interest for deep tissue imaging due to the lower scattering of light. SWIR spatial frequency domain imaging (SWIR SFDI) provides wide-field tissue optical property measurements in this wavelength band. Key design and performance characteristics, such as portability, wavelength selection, measurement resolution, and the effect of skin have not yet been addressed for SWIR SFDI. AIM: To fabricate and characterize a SWIR SFDI system for clinical use. APPROACH: The optimal choice of wavelengths was identified based on optical property uncertainty estimates and imaging depth. A compact light-emitting diode-based dual wavelength SWIR SFDI system was fabricated. A two-layer inverse model was developed to account for the layered structure of skin. Performance was validated using tissue-simulating phantoms and in-vivo measurements from three healthy subjects. RESULTS: The SWIR SFDI system had a µs' resolution of at least 0.03 mm - 1 at 880 nm and 0.02 mm - 1 at 1100 nm. The two-layer inverse model reduced the error in deeper layer µs' extractions by at least 24% in the phantom study. The two-layer model also increased the contrast between superficial vessels and the surrounding tissue for in-vivo measurements. CONCLUSION: The clinic-ready SWIR SFDI device is sensitive to small optical property alterations in diffuse media, provides enhanced accuracy in quantifying optical properties in the deeper layers in phantoms, and provided enhanced contrast of subcutaneous blood vessels.


Assuntos
Diagnóstico por Imagem , Pele , Diagnóstico por Imagem/métodos , Humanos , Imagem Óptica/métodos , Imagens de Fantasmas , Pele/diagnóstico por imagem
19.
Sci Rep ; 12(1): 5864, 2022 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-35393476

RESUMO

Spatial Frequency Domain Imaging (SFDI) can provide longitudinal, label-free, and widefield hemodynamic and scattering measurements of murine tumors in vivo. Our previous work has shown that the reduced scattering coefficient (µ's) at 800 nm, as well as the wavelength dependence of scattering, both have prognostic value in tracking apoptosis and proliferation during treatment with anti-cancer therapies. However, there is limited work in validating these optical biomarkers in clinically relevant tumor models that manifest specific treatment resistance mechanisms that mimic the clinical setting. It was recently demonstrated that metronomic dosing of cyclophosphamide induces a strong anti-tumor immune response and tumor volume reduction in the E0771 murine breast cancer model. This immune activation mechanism can be blocked with an IFNAR-1 antibody, leading to treatment resistance. Here we present a longitudinal study utilizing SFDI to monitor this paired responsive-resistant model for up to 30 days of drug treatment. Mice receiving the immune modulatory metronomic cyclophosphamide schedule had a significant increase in tumor optical scattering compared to mice receiving cyclophosphamide in combination with the IFNAR-1 antibody (9% increase vs 10% decrease on day 5 of treatment, p < 0.001). The magnitude of these differences increased throughout the duration of treatment. Additionally, scattering changes on day 4 of treatment could discriminate responsive versus resistant tumors with an accuracy of 78%, while tumor volume had an accuracy of only 52%. These results validate optical scattering as a promising prognostic biomarker that can discriminate between treatment responsive and resistant tumor models.


Assuntos
Neoplasias da Mama , Animais , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Ciclofosfamida/farmacologia , Ciclofosfamida/uso terapêutico , Diagnóstico por Imagem , Feminino , Humanos , Imunidade , Estudos Longitudinais , Camundongos
20.
Cancer Res Commun ; 2(4): 246-257, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-36187936

RESUMO

Many patients with breast cancer have a poor prognosis with limited therapeutic options. Here, we investigated the potential of chemo-immunogenic therapy as an avenue of treatment. We utilized two syngeneic mouse mammary tumor models, 4T1 and E0771, to examine the chemo-immunogenic potential of cyclophosphamide and the mechanistic contributions of cyclophosphamide-activated type-I interferon (IFN) signaling to therapeutic activity. Chemically-activated cyclophosphamide induced robust IFNα/ß receptor-1-dependent signaling linked to hundreds of IFN-stimulated gene responses in both cell lines. Further, in 4T1 tumors, cyclophosphamide given on a medium-dose, 6-day intermittent metronomic schedule induced strong IFN signaling but comparatively weak immune cell infiltration associated with long-term tumor growth stasis. Induction of IFN signaling was somewhat weaker in E0771 tumors but was followed by widespread downstream gene responses, robust immune cell infiltration and extensive, prolonged tumor regression. The immune dependence of these effective anti-tumor responses was established by CD8 T-cell immunodepletion, which blocked cyclophosphamide-induced E0771 tumor regression and led to tumor stasis followed by regrowth. Strikingly, IFNα/ß receptor-1 antibody blockade was even more effective in preventing E0771 immune cell infiltration and blocked the major tumor regression induced by cyclophosphamide treatment. Type-I IFN signaling is thus essential for the robust chemo-immunogenic response of these tumors to cyclophosphamide administered on a metronomic schedule.


Assuntos
Neoplasias Encefálicas , Interferon Tipo I , Camundongos , Animais , Neoplasias Encefálicas/tratamento farmacológico , Administração Metronômica , Ciclofosfamida/farmacologia , Imunidade Inata , Interferon Tipo I/farmacologia , Modelos Animais de Doenças
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA