1.
J Arthroplasty ; 32(2): 601-609, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27597431

RESUMO

BACKGROUND: Short-stemmed femoral components facilitate reduced exposure surgical techniques while preserving native bone. A clinically successful stem should ideally reduce risk for stress shielding while maintaining adequate primary stability for biological fixation. We asked (1) how stem-length changes cortical strain distribution in the proximal femur in a fit-and-fill geometry and (2) if short-stemmed components exhibit primary stability on par with clinically successful designs. METHODS: Cortical strain was assessed via digital image correlation in composite femurs implanted with long, medium, and short metaphyseal fit-and-fill stem designs in a single-leg stance loading model. Strain was compared to a loaded, unimplanted femur. Bone-implant micromotion was then compared with reduced lateral shoulder short stem and short tapered-wedge designs in cyclic axial and torsional testing. RESULTS: Femurs implanted with short-stemmed components exhibited cortical strain response most closely matching that of the intact femur model, theoretically reducing the potential for proximal stress shielding. In micromotion testing, no difference in primary stability was observed as a function of reduced stem length within the same component design. CONCLUSION: Our findings demonstrate that within this fit-and-fill stem design, reduction in stem length improved proximal cortical strain distribution and maintained axial and torsional stability on par with other stem designs in a composite femur model. Short-stemmed implants may accommodate less invasive surgical techniques while facilitating more physiological femoral loading without sacrificing primary implant stability.


Assuntos
Fêmur/cirurgia , Prótese de Quadril , Desenho de Prótese , Fêmur/fisiologia , Humanos , Estresse Mecânico
2.
J Biomech Eng ; 138(4): 041001, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26810930

RESUMO

Prosthetic alignment, patient characteristics, and implant design are all factors in long-term survival of total knee arthroplasty (TKA), yet the level at which each of these factors contribute to implant loosening has not been fully described. Prior clinical and biomechanical studies have indicated tibial overload as a cause of early TKA revision. The purpose of this study was to determine the relationship between tibial component design and bone resection on tibial loading. Finite-element analysis (FEA) was performed after simulated implantation of metal backed (MB) and all-polyethylene (AP) TKA components in 5 and 15 mm of tibial resection into a validated intact tibia model. Proximal tibial strains significantly increased between 13% and 199% when implanted with AP components (p < 0.05). Strain significantly increased between 12% and 209% in the posterior tibial compartment with increased bone resection (p < 0.05). This study indicates elevated strains in AP implanted tibias across the entirety of the proximal tibial cortex, as well as a posterior shift in tibial loading in instances of increased resection depth. These results are consistent with trends observed in prior biomechanical studies and may associate the documented device history of tibial collapse in AP components with increased bone strain and overload beneath the prosthesis.


Assuntos
Artroplastia do Joelho , Análise de Elementos Finitos , Teste de Materiais , Fenômenos Mecânicos , Metais , Tíbia/cirurgia , Próteses e Implantes , Estresse Mecânico
3.
J Arthroplasty ; 29(3): 541-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24290741

RESUMO

Limited experimental data exist comparing the mechanical response of the tibial cortex between fixed and rotating platform (RP) total knee arthroplasty (TKA), particularly in the revision setting. We asked if RP-TKA significantly affects tibiofemoral torque and cortical stain response in both the primary and revision settings. Fixed and RP tibial trays were implanted into analogue tibias and biomechanically tested under axial and torsional loading. Torque and strain response were analyzed using digital image correlation. Fixed bearing designs exhibited 13.8 times greater torque (P<0.01), and 69% (P<0.01) higher cortical strain than RP designs. Strain response was similar in the primary and revision cohorts. The decrease in torque transfer could act as a safeguard to reduce stress, micromotion and torsional fatigue in scenario of poor bone stock.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/fisiopatologia , Prótese do Joelho , Tíbia/fisiopatologia , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/cirurgia , Modelos Teóricos , Desenho de Prótese , Reoperação , Estresse Mecânico , Tíbia/cirurgia , Torque
4.
J Arthroplasty ; 28(3): 510-6, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23142455

RESUMO

Initial stability with limited micromotion in uncemented total hip arthroplasty acetabular components is essential for bony attachment and long-term biomechanical fixation. This study compared porous titanium fixation surfaces to clinically established, plasma-sprayed designs in terms of interface stability and required seating force. Porous plasma-sprayed modular and metal-on-metal (MOM) cups were compared to a modular, porous titanium designs. Cups were implanted into polyurethane blocks with1-mm interference fit and subsequently edge loaded to failure. Porous titanium cups exhibited 23% to 65% improvement in initial stability when compared to plasma-sprayed cup designs (P=.01): a clinically significant increase, based on experience and prior literature. The results of this study indicate increased interface stability in porous titanium-coated cups without significantly increasing the necessary force and energy required for full seating.


Assuntos
Prótese de Quadril , Teste de Materiais , Desenho de Prótese , Acetábulo , Fenômenos Biomecânicos , Materiais Revestidos Biocompatíveis , Titânio
5.
J Arthroplasty ; 28(9 Suppl): 179-83, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23518429

RESUMO

With increased precision in alignment offered by new generations of instrumentation and customized guides, this study was designed to establish a biomechanically-based target alignment for the balance of tibial loading in order to diminish the likelihood of pain and subsidence related to mechanical overload post-UKA. Sixty composite tibias were implanted with Oxford UKA tibial components with varied sagittal slope, resection depth, rotation and medial shift using patient matched instrumentation. Digital image correlation and strain gage analysis was conducted in static loading to evaluate strain distribution as a result of component alignment. In this model, minimal distal resection and most lateral positioning, neutral component rotation, and 3° of slope (from mechanical axis) exhibited the most balanced strain response to loading following UKA.


Assuntos
Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia , Artroplastia do Joelho , Fenômenos Biomecânicos , Humanos , Tíbia/anatomia & histologia , Tíbia/fisiopatologia
6.
J Arthroplasty ; 26(5): 777-82, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20870385

RESUMO

Clinical success of unicompartmental knee arthroplasty (UKA) is on the rise and is dependent on multiple patient, implant, and surgical factors. Tibial subsidence has been clinically reported as a cause of failure in UKA with an all-polyethylene tibial design in the absence of metal backing, yet the role of metal backing UKA tibial components on tibial loading is not fully understood. In this study, composite tibiae were implanted with medial all-polyethylene fixed-bearing or metal-backed UKA tibial components and a 1.5-kN load applied in 3 different contact positions simulating femoral translation during gait. All-polyethylene tibial components exhibited significantly higher strain measurements in each femoral position. This study demonstrates the role that metal backing plays on generating an even loading distribution while diminishing the development localized regions of excessive loading across the medial tibial cortex.


Assuntos
Artroplastia do Joelho/instrumentação , Simulação por Computador , Prótese do Joelho , Metais , Desenho de Prótese , Tíbia , Fenômenos Biomecânicos , Marcha , Humanos , Modelos Biológicos , Polietileno , Suporte de Carga
7.
J Knee Surg ; 34(2): 192-199, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31394587

RESUMO

Highly porous ingrowth surfaces have been introduced into tibial tray fixation to improve long-term survivorship in cementless total knee arthroplasty. This study was designed to evaluate the effect of porous ingrowth surface on primary stability in the implanted cementless tibial component. Three tibial tray designs possessing sintered bead or roughened porous coating ingrowth surfaces were implanted into a foam tibia model with primary stability assessed via digital image correlation during stair descent and condylar liftoff loading. Follow-up testing was conducted by implanting matched-pair cadaveric tibias with otherwise identical trays with two iterations of ingrowth surface design. Trays were loaded and micromotion evaluated in a condylar liftoff model. The sintered bead tibial tray exhibited slightly lower micromotion than the roughened porous coating in stair descent loading. However, no significant difference in primary stability was observed in condylar liftoff loading in either foam or cadaveric specimens. Cementless tibial trays featuring two different iterations of porous ingrowth surfaces demonstrated both good stability in cadaveric specimens with less than 80 microns of micromotion and 1 mm of subsidence under cyclic loading. While improved ingrowth surfaces may lead to improved biological fixation and long-term osteointegration, this study was unable to identify a difference in primary stability associated with subsequent ingrown surface design iteration.


Assuntos
Artroplastia do Joelho , Instabilidade Articular/cirurgia , Prótese do Joelho , Osseointegração , Tíbia/cirurgia , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Cimentos Ósseos , Cimentação , Humanos , Instabilidade Articular/fisiopatologia , Modelos Anatômicos , Osseointegração/fisiologia , Porosidade , Desenho de Prótese , Tíbia/fisiopatologia
8.
Proc Inst Mech Eng H ; 231(8): 691-698, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28393600

RESUMO

Press-fit acetabular components are susceptible to rim deformation. The inherent variability within acetabular reaming techniques may generate increased press-fit and, subsequently, additional component deformation. The purpose of this study was to analyze the insertion and deformation characteristics of acetabular components designed for dual-mobility systems based on component design, size, and reaming technique. Shell deformation was quantified in a validated worst-case scenario foam pinch model. Thin-walled, one-piece, and modular dual-mobility shells of varying size were implanted in under- and over-reamed cavities with insertion force measured and shell deformation assessed using digital image correlation. Increased shell size resulted in larger rim deformation in one-piece components, with a reduction in press-fit by 1 mm resulting in up to 48% reduction in insertion forces and between 23% and 51% reduction in shell deformation. Lower insertion forces and deformations were observed in modular components. Variability in acetabular reaming plays a significant role in the ease of implantation and component deformation in total hip arthroplasty. Modular components are less susceptible to deformation than thin-walled monoblock shells. Care should be taken to avoid excessive under-reaming, particularly in the scenario of large shell size and high-density patient bone stock.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Fenômenos Mecânicos , Desenho de Prótese
9.
J Hand Surg Am ; 27(1): 86-92, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11810619

RESUMO

A 3-dimensional finite element model was used to study pin fixation in simulated unstable extra-articular distal radius fractures. Bone geometry and material properties were generated from computed tomography. The model was validated in cadaver testing. The model is robust and an accurate predictor of bone stresses and fracture stability under pure axial load. Three different pinning configurations and 3 different pin materials were evaluated. Crossed pinning provided greater fracture stability and a broader distribution of bone stresses than pinning through the radius styloid alone. Steel pins provided greater fracture stability; however, bioabsorbable pins produced lower stress concentration in the bone near the pins. A finite element model is useful in showing differences between various pin constructs in the treatment of distal radius fractures.


Assuntos
Análise de Elementos Finitos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Dispositivos de Fixação Ortopédica , Fraturas do Rádio/cirurgia , Estresse Mecânico , Idoso , Idoso de 80 Anos ou mais , Feminino , Fixação de Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Valor Preditivo dos Testes , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/fisiopatologia , Rádio (Anatomia)/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/fisiopatologia , Tomografia Computadorizada por Raios X