Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
2.
Ann Allergy Asthma Immunol ; 95(4): 389-93, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16279570

RESUMO

BACKGROUND: Bacitracin is widely used in operating rooms to soak implants, irrigate compound fractures, and apply to surgical incisions. However, bacitracin is a known sensitizer and causes not only allergic contact dermatitis but also anaphylaxis. OBJECTIVE: To describe a 72-year-old woman with anaphylaxis after irrigation and packing of an infected pacemaker pocket with a bacitracin solution. METHODS: Skin prick testing to bacitracin and latex; serum tryptase, serum histamine, serum IgE to latex, and serial cardiac enzyme measurements; blood cultures, transthoracic echocardiograms, and venograms were performed to characterize the reaction. RESULTS: Six hours after the anaphylactic event, the patient had an elevated serum tryptase level of 49 ng/mL (reference range, 2-10 ng/mL), which normalized the next morning. She had immediate-type skin prick test reactions to full-strength bacitracin ointment (500 U/g) and bacitracin solution (150 U/mL). Serum IgE level to latex was undetectable, and results of skin testing to latex were negative. CONCLUSIONS: To our knowledge, this is the first case report of anaphylaxis to bacitracin during pacemaker surgery. This case illustrates that intraoperative anaphylaxis to bacitracin can be life-threatening.


Assuntos
Anafilaxia/induzido quimicamente , Anti-Infecciosos Locais/efeitos adversos , Bacitracina/efeitos adversos , Complicações Intraoperatórias , Marca-Passo Artificial , Idoso , Anafilaxia/diagnóstico , Procedimentos Cirúrgicos Cardíacos , Feminino , Humanos , Testes Cutâneos , Irrigação Terapêutica
3.
J Interv Cardiol ; 17(3): 171-7, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15209580

RESUMO

INTRODUCTION: Irrigated tip radiofrequency ablation of cardiac arrhythmias was developed to increase the size of the radiofrequency-induced lesion, since cooling of the electrode tip allows use of higher power settings. The purpose of this study was to determine if the increased lesion size during irrigated tip ablation is caused by the cooling effect solely or if increased electrical conductivity around the tip also contributes by increasing the "current-delivering size" of the tip: the so-called "virtual electrode effect." METHODS AND RESULTS: In vitro strips of left ventricular porcine myocardium and in vivo canine left ventricles were ablated. In vitro closed loop tip and showerhead irrigated tip catheters were compared. In vitro and in vivo showerhead tip catheters irrigated with solutions having different ionic content were compared. We found no difference in lesion size for closed loop and showerhead-type catheters (998 +/- 345 vs. 811 +/- 313 mm(3) during power-controlled ablation and 227 +/- 76 vs 318 +/- 127 mm(3) during temperature-controlled ablation). For irrigation with liquids having increasing ionic strength we found a decrease in lesion volume in vitro (361 +/- 249 vs. 812 +/- 229 mm(3) (P < 0.001) for power-controlled and 156 +/- 78 vs. 318 +/- 127 mm(3) (P < 0.05) for temperature-controlled ablation and nonsignificant differences in vivo. CONCLUSIONS: The mechanism for enlarging lesion size during radiofrequency irrigated-tip ablation is that higher power levels can be used. There is no virtual electrode effect caused by the highly conductive surroundings of the tip during irrigation. In vitro this effect is shown to be opposite: it decreases lesion size.


Assuntos
Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Ventrículos do Coração/patologia , Miocárdio/patologia , Animais , Cães , Eletrodos , Desenho de Equipamento , Técnicas In Vitro , Suínos , Temperatura
4.
Bol. Asoc. Méd. P. R ; 83(8): 346-8, ago. 1991.
Artigo em Inglês | LILACS | ID: lil-108086

RESUMO

Nosocomial infections with cytomegalovirus are on area of great concern and controversy within the medical community. With the advent of organ transplantation there rave been an increased number of susceptible individuals. In the past most cases were confined to newborn nurseries and the neonatal intensive care unit. It is of great interested that recent evidence suggests that health care providers are at no greater risk of acquiring CMV infection inside the hospital setting when compared to a representative control group within the same community. This paper will review some of the literature that deals with the nosocomial transmission of CMV. We will try to emphasize transmission, diagnosis, prevention, and treatment of CMV infection


Assuntos
Infecções por Citomegalovirus/transmissão , Infecção Hospitalar/transmissão , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/prevenção & controle , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA