Opt Express ; 29(2): 1879-1889, 2021 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-33726392

RESUMO

High-energy deep ultraviolet (UV) sources are required for high-density plasma diagnostics. The fifth-harmonic generation of large-aperture neodymium lasers in ammonium dihydrogen phosphate (ADP) can significantly increase UV energies due to the availability of large ADP crystals. Noncritical phase matching in ADP for (ω + 4ω) was achieved by cooling a 65 × 65-mm crystal in a two-chamber cryostat to 200 K. The crystal chamber used helium as the thermally conductive medium between the crystal and the crystal chamber, which was surrounded by a high-vacuum chamber with a liquid nitrogen reservoir. A temperature variation of 0.2 K across the crystal aperture was obtained. The total conversion efficiency from the fundamental to the fifth harmonic at 211 nm was 26%.

2.
Appl Opt ; 57(32): 9571-9583, 2018 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-30461737

RESUMO

Multibeam lasers often require an output beam balance that specifies the degree of simultaneity of the laser output energy, instantaneous power, or instantaneous irradiance (power per unit area). This work describes the general problem of balancing a multibeam laser. Specific techniques used to balance the output power of the 60-beam pulsed OMEGA Laser System are discussed along with a measured reduction of beam-to-beam imbalance. In particular, the square-pulse distortion induced by a simple saturating amplifier operating with its output at some fraction of its saturation fluence is derived, and a method to exchange gain between saturated amplifiers in a single beam that have different saturation fluences to adjust balance is described.

3.
Rev Sci Instrum ; 93(12): 123502, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586943

RESUMO

A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>1018 W/cm2) laser-plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 µm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. The initial results from four OMEGA EP THz experiments detected up to ∼15µJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.

4.
Rev Sci Instrum ; 92(4): 043546, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243381

RESUMO

Neutron time-of-flight (nTOF) detectors are used to diagnose the conditions present in inertial confinement fusion (ICF) experiments and basic laboratory physics experiments performed on an ICF platform. The instrument response function (IRF) of these detectors is constructed by convolution of two components: an x-ray IRF and a neutron interaction response. The shape of the neutron interaction response varies with incident neutron energy, changing the shape of the total IRF. Analyses of nTOF data that span a broad range of energies must account for this energy-dependence in order to accurately infer plasma parameters and nuclear properties in ICF experiments. This work briefly reviews a matrix multiplication approach to convolution, which allows for an energy-dependent change in the shape of the IRF. This method is applied to synthetic data resembling symmetric cryogenic DT implosions to examine the effect of the energy-dependent IRF on the inferred areal density. The results of forward fits that infer ion temperatures and areal densities from nTOF data collected during cryogenic DT experiments on OMEGA are also discussed.

5.
Rev Sci Instrum ; 92(1): 013509, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33514216

RESUMO

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. In DT implosions with neutron yield larger than 1013, a novel detector consisting of a microchannel-plate (MCP) photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signals in PMT nTOF detectors are produced from neutron interaction with a PMT window. The direct interaction of neutrons with the MCP provides negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF detector faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOF detectors were deployed in the OMEGA laser system for the first time to diagnose inertial confinement fusion plasma. The design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

6.
Rev Sci Instrum ; 92(3): 033529, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33819982

RESUMO

Three-dimensional reconstruction algorithms have been developed, which determine the hot-spot velocity, hot-spot apparent ion temperature distribution, and fuel areal-density distribution present in laser-direct-drive inertial confinement fusion implosions on the OMEGA laser. These reconstructions rely on multiple independent measurements of the neutron energy spectrum emitted from the fusing plasma. Measurements of the neutron energy spectrum on OMEGA are made using a suite of quasi-orthogonal neutron time-of-flight detectors and a magnetic recoil spectrometer. These spectrometers are positioned strategically around the OMEGA target chamber to provide unique 3D measurements of the conditions of the fusing hot spot and compressed fuel near peak compression. The uncertainties involved in these 3D reconstructions are discussed and are used to identify a new nTOF diagnostic line of sight, which when built will reduce the uncertainty in the hot-spot apparent ion temperature distribution from 700 to <400 eV.

7.
Rev Sci Instrum ; 87(11): 11E323, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910320

RESUMO

A four-channel, time-resolved, hard x-ray detector (HXRD) has been operating at the Laboratory for Laser Energetics for more than a decade. The slope temperature of the hot-electron population in direct-drive inertial confinement fusion experiments is inferred by recording the hard x-ray radiation generated in the interaction of the electrons with the target. Measuring the energy deposited by hot electrons requires an absolute calibration of the hard x-ray detector. A novel method to obtain an absolute calibration of the HXRD using single photons from radioactive sources was developed, which uses a thermoelectrically cooled, low-noise, charge-sensitive amplifier.

8.
Rev Sci Instrum ; 87(11): 11D814, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910405

RESUMO

Upgraded microchannel-plate-based photomultiplier tubes (MCP-PMT's) with increased stability to signal-shape linearity have been implemented on the 13.4-m neutron time-of-flight (nTOF) detector at the Omega Laser Facility. This diagnostic uses oxygenated xylene doped with diphenyloxazole C15H11NO + p-bis-(o-methylstyryl)-benzene (PPO + bis-MSB) wavelength shifting dyes and is coupled through four viewing ports to fast-gating MCP-PMT's, each with a different gain to allow one to measure the light output over a dynamic range of 1 × 106. With these enhancements, the 13.4-m nTOF can measure the D(t,n)4He and D(d,n)3He reaction yields and average ion temperatures in a single line of sight. Once calibrated for absolute neutron sensitivity, the nTOF detectors can be used to measure the neutron yield from 1 × 109 to 1 × 1014 and the ion temperature with an accuracy approaching 5% for both the D(t,n)4He and D(d,n)3He reactions.