Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Labelled Comp Radiopharm ; 60(12): 592-595, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28833348

RESUMO

We report herein a modification to a component of the GE radiochemistry system that increases the yield and reliability of [11 C]CN- production from [11 C]carbon dioxide.


Assuntos
Radioisótopos de Carbono/química , Cianetos/química , Radioquímica/instrumentação , Cianetos/síntese química , Marcação por Isótopo
2.
Synapse ; 70(3): 112-20, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26671330

RESUMO

Glycine transporter type-1 (GlyT1) has been proposed as a target for drug development for schizophrenia. PET imaging with a GlyT1 specific radiotracer will allow for the measurement of target occupancy of GlyT1 inhibitors, and for in vivo investigation of GlyT1 alterations in schizophrenia. We conducted a comparative evaluation of two GlyT1 radiotracers, [(11) C]GSK931145, and [(18) F]MK-6577, in baboons. Two baboons were imaged with [(11) C]GSK931145 and [(18) F]MK-6577. Blocking studies with GSK931145 (0.3 or 0.2 mg/kg) were conducted to determine the level of tracer specific binding. [(11) C]GSK931145 and [(18) F]MK-6577 were synthesized in good yield and high specific activity. Moderately fast metabolism was observed for both tracers, with ∼ 30% of parent at 30 min post-injection. In the brain, both radiotracers showed good uptake and distribution profiles consistent with regional GlyT1 densities. [(18) F]MK-6577 displayed higher uptake and faster kinetics than [(11) C]GSK931145. Time activity curves were well described by the two-tissue compartment model. Regional volume of distribution (VT ) values were higher for [(18) F]MK-6577 than [(11) C]GSK931145. Pretreatment with GSK931145 reduced tracer uptake to a homogeneous level throughout the brain, indicating in vivo binding specificity and lack of a reference region for both radiotracers. Linear regression analysis of VT estimates between tracers indicated higher specific binding for [(18) F]MK-6577 than [(11) C]GSK931145, consistent with higher regional binding potential (BPND ) values of [(18) F]MK-6577 calculated using VT from the baseline scans and non-displaceable distribution volume (VND ) derived from blocking studies. [(18) F]MK-6577 appears to be a superior radiotracer with higher brain uptake, faster kinetics, and higher specific binding signals than [(11) C]GSK931145.


Assuntos
Benzamidas , Radioisótopos de Carbono , Glicinérgicos , Proteínas da Membrana Plasmática de Transporte de Glicina/metabolismo , Compostos Radiofarmacêuticos , Sulfonamidas , Animais , Benzamidas/síntese química , Benzamidas/química , Benzamidas/farmacocinética , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Mapeamento Encefálico , Radioisótopos de Carbono/farmacocinética , Cromatografia Líquida de Alta Pressão , Avaliação Pré-Clínica de Medicamentos , Feminino , Glicinérgicos/síntese química , Glicinérgicos/química , Glicinérgicos/farmacocinética , Cinética , Modelos Lineares , Imageamento por Ressonância Magnética , Estrutura Molecular , Papio , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/síntese química , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/farmacocinética , Sulfonamidas/síntese química , Sulfonamidas/química , Sulfonamidas/farmacocinética
3.
J Cereb Blood Flow Metab ; 42(8): 1398-1409, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35209743

RESUMO

The NMDA receptor GluN2B subunit is a target of interest in neuropsychiatric disorders but to date there is no selective radiotracer available to quantify its availability in vivo. Here we report direct comparisons in non-human primates of three GluN2B-targeting radioligands: (R)-[11C]NR2B-Me, (R)-[18F]OF-Me-NB1, and (S)-[18F]OF-NB1. Plasma free fraction, metabolism, tissue distribution and kinetics, and quantitative kinetic modeling methods and parameters were evaluated in two adult rhesus macaques. Free fraction in plasma was <2% for (R)-[11C]NR2B-Me and (R)-[18F]OF-Me-NB1 and higher for (S)-[18F]OF-NB1 (15%). All radiotracers showed good brain uptake and distribution throughout grey matter, with substantial (>68%) blockade across the brain by the GluN2B-targeting drug Co-101,244 (0.25 mg/kg), including in the cerebellum. Time-activity curves were well-fitted by the one-tissue compartment model, with volume of distribution values of 20-40 mL/cm3 for (R)-[11C]NR2B-Me, 8-16 mL/cm3 for (R)-[18F]OF-Me-NB1, and 15-35 mL/cm3 for (S)-[18F]OF-NB1. Estimates of regional non-displaceable binding potential were in the range of 2-3 for (R)-[11C]NR2B-Me and (S)-[18F]-OF-NB1, and 0.5-1 for (R)-[18F]OF-Me-NB1. Altogether, each radiotracer showed an acceptable profile for quantitative imaging of GluN2B. (S)-[18F]OF-NB1 has particularly promising imaging characteristics for potential translation into humans. However, the source of unexpected displaceable binding in the cerebellum for each of these compounds requires further investigation.


Assuntos
Compostos Radiofarmacêuticos , Receptores de N-Metil-D-Aspartato , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Macaca mulatta/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/metabolismo , Receptores de N-Metil-D-Aspartato/metabolismo
4.
J Cereb Blood Flow Metab ; 40(4): 695-704, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-30895878

RESUMO

11ß-Hydroxysteroid dehydrogenase type 1 (11ß-HSD1) catalyzes enzymatic conversion of cortisone into the stress hormone cortisol. This first-in-human brain imaging study characterizes the kinetic modeling and test-retest reproducibility of [18F]AS2471907, a novel PET radiotracer for 11ß-HSD1. Eight individuals underwent one 180-min (n = 4) or two 240-min (n = 4) [18F]AS2471907 PET brain scans (12 total) acquired on the high-resolution research tomograph (HRRT) scanner with arterial blood sampling. Imaging data were modeled with 1-tissue (1T) and 2-tissue (2T) compartment models and with multilinear analysis (MA1) to estimate [18F]AS2471907 availability (VT). [18F]AS2471907 demonstrated high, heterogeneous uptake throughout the brain. Of the compartment models, 2T best described [18F]AS2471907 data. Estimates of VT were highly correlated between 2T and MA1 (t* = 30 min) with MA1 yielding VT values ranging from 3.2 ± 1.0 mL/cm3 in the caudate to 15.7 ± 4.2 mL/cm3 in the occipital cortex. The median absolute test-retest variability of 16 ± 5% and high intraclass correlation coefficient (ICC) values of 0.67-0.97 across regions indicate fair test-retest reliability but large intersubject variability. VT estimates using 180 min were within 10% of estimates using full acquisition time. In summary, [18F]AS2471907 exhibits reasonable kinetic properties for imaging 11ß-HSD1 in human brain.


Assuntos
11-beta-Hidroxiesteroide Desidrogenase Tipo 1/metabolismo , Encéfalo/diagnóstico por imagem , Imagem Molecular/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Triazóis/farmacocinética , Adulto , Encéfalo/enzimologia , Feminino , Radioisótopos de Flúor , Humanos , Hidrocortisona/sangue , Cinética , Masculino , Modelos Biológicos , Compostos Radiofarmacêuticos/sangue , Distribuição Tecidual , Triazóis/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA