1.
Skin Res Technol ; 30(3): e13622, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38500350

RESUMO

BACKGROUND AND OBJECTIVE: Skin thermal diffusivity plays a crucial role in various applications, including laser therapy and cryogenic skin cooling.This study investigates the correlation between skin thermal diffusivity and two important skin parameters, melanin content and erythema, in a cohort of 102 participants. METHODS: An in-house developed device based on transient temperature measurement was used to assess thermal diffusivity at different body locations. Melanin content and erythema were measured using a colorimeter. Statistical analysis was performed to examine potential correlations. RESULTS: The results showed that the measured thermal diffusivity values were consistent with previous reports, with variations observed among subjects. No significant correlation was found between thermal diffusivity and melanin content or erythema. This suggests that other factors, such as skin hydration or epidermis thickness, may have a more dominant influence on skin thermal properties. CONLCUSION: This research provides valuable insights into the complex interplay between skin thermal properties and physiological parameters, with potential implications for cosmetic and clinical dermatology applications.


Assuntos
Melaninas , Pigmentação da Pele , Humanos , Pele/diagnóstico por imagem , Eritema , Epiderme
2.
Soft Matter ; 18(30): 5662-5675, 2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35861313

RESUMO

Pronounced fingering of the waterfront is observed for in-plane wicking in thin, aligned electrospun fibrous membranes. We hypothesize that a perturbation in capillary pressure triggers the onset of fingering, which grows in a non-local manner based on the waterfront gradient. Vertical and horizontal wicking in thin electrospun membranes of poly(ethylene-co-vinyl alcohol) (EVOH) fibers with varying fiber alignment and degree of orientation is studied with backlight photography. A non-local transport model considering the gradient of the waterfront is developed, where fiber orientation is modeled with a correlated random field. The model shows that a transition from straight to highly fingered waterfront occurs during water uptake as observed in the experiment. The size and shape of the fingers depend on fiber orientation. Based on good model agreement, we show that, during wicking in thin electrospun membranes, fingering is initially triggered by a perturbation in capillary pressure caused by the underlying anisotropic and heterogeneous membrane structure which grows in a non-local manner depending on the waterfront gradient.

3.
Chimia (Aarau) ; 76(3): 229-235, 2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38069737

RESUMO

The rising interest in designing fibres via spinning techniques combining the properties of various polymeric materials into advanced functionalised materials is directed towards targeted biomedical applications such as drug delivery, wearable sensors or tissue engineering. Understanding how these functional polymers exhibit multiscale structures ranging from the molecular level to nano-, micro-and millimetre scale is a key prerequisite for their challenging applications that can be addressed by a non-destructive X-ray based analytical approach. X-ray multimodalities combining X-ray imaging, scattering and diffraction allow the study of morphology, molecular structure, and the analysis of nano-domain size and shape, crystallinity and preferential orientation in 3D arrangements. The incorporation of X-ray analytics in the design process of polymeric fibers via their nanostructure under non-ambient conditions (i.e. temperature, mechanical load, humidity…) allows for efficient optimization of the fabrication process as well as quality control along the product lifetime under operating environmental conditions. Here, we demonstrate the successful collaboration between the laboratory of Biomimetic Textiles and Membranes and the Center of X-ray Analytics at Empa for the design, characterisation and optimisation of advanced functionalised polymeric fibrous material systems.

4.
Chimia (Aarau) ; 76(3): 249-254, 2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38069740

RESUMO

The COVID-19 pandemic resulted in shortages of personal protective equipment and medical devices in the initial phase. Agile small and medium-sized enterprises from regional textile industries reacted quickly. They delivered alternative products such as textile-based community masks in collaboration with industrial partners and research institutes from various sectors. The current mask materials and designs were further improved by integrating textiles with antiviral and antimicrobial properties and enhanced protection and comfort by novel textile/membrane combinations, key factors to increase the acceptance and compliance of mask wearing. The innocuity and sustainability of masks, as well as taking into account particular needs of vulnerable persons in our society, are new fields for textile-based innovations. These innovations developed for the next generation of facemasks have a high adaptability to other product segments, which make textiles an attractive material for hygienic applications and beyond.

5.
Soft Matter ; 17(23): 5772-5779, 2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34027537

RESUMO

Structural colors are produced by wavelength-dependent scattering of light from nanostructures. While living organisms often exploit phase separation to directly assemble structurally colored materials from macromolecules, synthetic structural colors are typically produced in a two-step process involving the sequential synthesis and assembly of building blocks. Phase separation is attractive for its simplicity, but applications are limited due to a lack of robust methods for its control. A central challenge is to arrest phase separation at the desired length scale. Here, we show that solid-state polymerization-induced phase separation can produce stable structures at optical length scales. In this process, a polymeric solid is swollen and softened with a second monomer. During its polymerization, the two polymers become immiscible and phase separate. As free monomer is depleted, the host matrix resolidifies and arrests coarsening. The resulting polymeric composites have a blue or white appearance. We compare these biomimetic nanostructures to those in structurally-colored feather barbs, and demonstrate the flexibility of this approach by producing structural color in filaments and large sheets.


Assuntos
Plumas , Nanoestruturas , Animais , Cor , Polimerização , Polímeros
6.
Sensors (Basel) ; 21(14)2021 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-34300649

RESUMO

To improve the measurement and subsequent use of human skin temperature (Tsk) data, there is a need for practical methods to compare Tsk sensors and to quantify and better understand measurement error. We sought to develop, evaluate, and utilize a skin model with skin-like thermal properties as a tool for benchtop Tsk sensor comparisons and assessments of local temperature disturbance and sensor bias over a range of surface temperatures. Inter-sensor comparisons performed on the model were compared to measurements performed in vivo, where 14 adult males completed an experimental session involving rest and cycling exercise. Three types of Tsk sensors (two of them commercially available and one custom made) were investigated. Skin-model-derived inter-sensor differences were similar (within ±0.4 °C) to the human trial when comparing the two commercial Tsk sensors, but not for the custom Tsk sensor. Using the skin model, all surface Tsk sensors caused a local temperature disturbance with the magnitude and direction dependent upon the sensor and attachment and linearly related to the surface-to-environment temperature gradient. Likewise, surface Tsk sensors also showed bias from both the underlying disturbed surface temperature and that same surface in its otherwise undisturbed state. This work supports the development and use of increasingly realistic benchtop skin models for practical Tsk sensor comparisons and for identifying potential measurement errors, both of which are important for future Tsk sensor design, characterization, correction, and end use.


Assuntos
Temperatura Cutânea , Adulto , Temperatura Corporal , Exercício Físico , Humanos , Masculino , Pele , Temperatura
7.
Sensors (Basel) ; 21(8)2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33918956

RESUMO

Thanks to its negative surface charge and high swelling behavior, montmorillonite (MMT) has been widely used to design hybrid materials for applications in metal ion adsorption, drug delivery, or antibacterial substrates. The changes in photophysical and photochemical properties observed when fluorophores interact with MMT make these hybrid materials attractive for designing novel optical sensors. Sensor technology is making huge strides forward, achieving high sensitivity and selectivity, but the fabrication of the sensing platform is often time-consuming and requires expensive chemicals and facilities. Here, we synthesized metal-modified MMT particles suitable for the bio-sensing of self-fluorescent biomolecules. The fluorescent enhancement achieved by combining clay minerals and plasmonic effect was exploited to improve the sensitivity of the fluorescence-based detection mechanism. As proof of concept, we showed that the signal of fluorescein isothiocyanate can be harvested by a factor of 60 using silver-modified MMT, while bovine serum albumin was successfully detected at 1.9 µg/mL. Furthermore, we demonstrated the versatility of the proposed hybrid materials by exploiting their plasmonic properties to develop liquid label-free detection systems. Our results on the signal enhancement achieved using metal-modified MMT will allow the development of highly sensitive, easily fabricated, and cost-efficient fluorescent- and plasmonic-based detection methods for biomolecules.


Assuntos
Bentonita , Prata , Antibacterianos , Soroalbumina Bovina
8.
Opt Express ; 28(11): 16673-16695, 2020 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-32549485

RESUMO

Interpreting the polarimetric data from fiber-like macromolecules constitutive of tissue can be difficult due to strong scattering. In this study, we probed the superficial layers of fibrous tissue models (membranes consisting of nanofibers) displaying varying degrees of alignment. To better understand the manifestation of membranes' degree of alignment in polarimetry, we analyzed the spatial variations of the backscattered light's Stokes vectors as a function of the orientation of the probing beam's linear polarization. The degree of linear polarization reflects the uniaxially birefringent behavior of the membranes. The rotational (a-)symmetry of the backscattered light's degree of linear polarization provides a measure of the membranes' degree of alignment.

9.
Langmuir ; 36(40): 11787-11797, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-32936649

RESUMO

We introduce the design and study of a hybrid electrospun membrane with a dedicated nanoscale structural hierarchy for controlled functions in the biomedical domain. The hybrid system comprises submicrometer-sized internally self-assembled lipid nanoparticles (ISAsomes or mesosomes) embedded into the electrospun membrane with a nanofibrous polymer network. The internal structure of ISAsomes, studied by small-angle X-ray scattering (SAXS) and electron microscopy, demonstrated a spontaneous response to variations in the environmental conditions as they undergo a bicontinuous inverse cubic phase (cubosomes) in solution to a crystalline lamellar phase in the polymer membrane; nevertheless, this phase reorganization is reversible. As revealed by in situ SAXS measurements, if the membrane was put in contact with aqueous media, the cubic phase reappeared and submicrometer-sized cubosomes were released upon dissolution of the nanofibers. Furthermore, the hybrid membranes exhibited a specific anisotropic feature and morphological response under an external strain. While nanofibers were aligned under external strain in the microscale, the semicrystalline domains from the polymer phase were positioned perpendicular to the lamellae of the lipid phase in the nanoscale. The fabricated membranes and their spontaneous responses offer new strategies for the development of structure-controlled functions in electrospun nanofibers for biomedical applications, such as drug delivery or controlled interactions with biointerfaces.

10.
J Nanobiotechnology ; 18(1): 166, 2020 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-33176791

RESUMO

BACKGROUND: Studying bacterial adhesion and early biofilm development is crucial for understanding the physiology of sessile bacteria and forms the basis for the development of novel antimicrobial biomaterials. Microfluidics technologies can be applied in such studies since they permit dynamic real-time analysis and a more precise control of relevant parameters compared to traditional static and flow chamber assays. In this work, we aimed to establish a microfluidic platform that permits real-time observation of bacterial adhesion and biofilm formation under precisely controlled homogeneous laminar flow conditions. RESULTS: Using Escherichia coli as the model bacterial strain, a microfluidic platform was developed to overcome several limitations of conventional microfluidics such as the lack of spatial control over bacterial colonization and allow label-free observation of bacterial proliferation at single-cell resolution. This platform was applied to demonstrate the influence of culture media on bacterial colonization and the consequent eradication of sessile bacteria by antibiotic. As expected, the nutrient-poor medium (modified M9 minimal medium) was found to promote bacterial adhesion and to enable a higher adhesion rate compared to the nutrient-rich medium (tryptic soy broth rich medium ). However, in rich medium the adhered cells colonized the glass surface faster than those in poor medium under otherwise identical conditions. For the first time, this effect was demonstrated to be caused by a higher retention of newly generated bacteria in the rich medium, rather than faster growth especially during the initial adhesion phase. These results also indicate that higher adhesion rate does not necessarily lead to faster biofilm formation. Antibiotic treatment of sessile bacteria with colistin was further monitored by fluorescence microscopy at single-cell resolution, allowing in situ analysis of killing efficacy of antimicrobials. CONCLUSION: The platform established here represents a powerful and versatile tool for studying environmental effects such as medium composition on bacterial adhesion and biofilm formation. Our microfluidic setup shows great potential for the in vitro assessment of new antimicrobials and antifouling agents under flow conditions.


Assuntos
Aderência Bacteriana/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Microfluídica/métodos , Antibacterianos/farmacologia , Biofilmes/efeitos dos fármacos , Meios de Cultura , Escherichia coli
11.
J Nanobiotechnology ; 18(1): 51, 2020 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-32188479

RESUMO

The state-of-the-art hernia meshes, used in hospitals for hernia repair, are predominantly polymeric textile-based constructs that present high mechanical strength, but lack antimicrobial properties. Consequently, preventing bacterial colonization of implanted prosthetic meshes is of major clinical relevance for patients undergoing hernia repair. In this study, the co-axial electrospinning technique was investigated for the development of a novel mechanically stable structure incorporating dual drug release antimicrobial action. Core/shell structured nanofibers were developed, consisting of Nylon-6 in the core, to provide the appropriate mechanical stability, and Chitosan/Polyethylene oxide in the shell to provide bacteriostatic action. The core/shell structure consisted of a binary antimicrobial system incorporating 5-chloro-8-quinolinol in the chitosan shell, with the sustained release of Poly(hexanide) from the Nylon-6 core of the fibers. Homogeneous nanofibers with a "beads-in-fiber" architecture were observed by TEM, and validated by FTIR and XPS. The composite nanofibrous meshes significantly advance the stress-strain responses in comparison to the counterpart single-polymer electrospun meshes. The antimicrobial effectiveness was evaluated in vitro against two of the most commonly occurring pathogenic bacteria; S. aureus and P. aeruginosa, in surgical site infections. This study illustrates how the tailoring of core/shell nanofibers can be of interest for the development of active antimicrobial surfaces.


Assuntos
Antibacterianos/farmacologia , Caprolactama/análogos & derivados , Caprolactama/farmacologia , Quitosana/farmacologia , Nanofibras/química , Polímeros/farmacologia , Infecção da Ferida Cirúrgica/tratamento farmacológico , Antibacterianos/química , Quitosana/química , Sistemas de Liberação de Medicamentos/métodos , Liberação Controlada de Fármacos , Humanos , Cinética , Testes de Sensibilidade Microbiana , Tamanho da Partícula , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Polímeros/química , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Propriedades de Superfície , Telas Cirúrgicas
12.
J Neuroeng Rehabil ; 17(1): 47, 2020 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-32272964

RESUMO

BACKGROUND: Tremor is the most common movement disorder with the highest prevalence in the upper limbs. The mechanical suppression of involuntary movements is an alternative and additional treatment to medication or surgery. Here we present a new, soft, lightweight, task asjustable and passive orthosis for tremor suppression. METHODS: A new concept of a manual, textile-based, passive orthosis was designed with an integrated, task adjustable, air-filled structure, which can easily be inflated or deflated on-demand for a certain daily activity. The air-filled structure is placed on the dorsal side of the wrist and gets bent and compressed by movements when inflated. In a constant volume air-filled structure, air pressure increases while it is inflating, creating a counterforce to the compression caused by bending. We characterised the air-filled structure stiffness by measuring the reaction torque as a function of the angle of deflection on a test bench. Furthermore, we evaluated the efficacy of the developed passive soft orthosis by analysing the suppression of involuntary movements in the wrist of a tremor-affected patient during different activities of daily living (i.e. by calculating the power spectral densities of acceleration). RESULTS: By putting special emphasis on the comfort and wearability of the orthosis, we achieved a lightweight design (33 g). The measurements of the angular deflection and resulting reaction torques show non-linear, hysteretic, behaviour, as well as linear behaviour with a coefficient of determination (R2) between 0.95 and 0.99. Furthermore, we demonstrated that the soft orthosis significantly reduces tremor power for daily living activities, such as drinking from a cup, pouring water and drawing a spiral, by 74 to 82% (p = 0.03); confirmed by subjective tremor-reducing perception by the patient. CONCLUSION: The orthosis we developed is a lightweight and unobtrusive assistive technology, which suppresses involuntary movements and shows high wearability properties, with the potential to be comfortable. This air-structure technology could also be applied to other movement disorders, like spasticity, or even be integrated into future exoskeletons and exosuits for the implementation of variable stiffness in the systems.


Assuntos
Aparelhos Ortopédicos , Desenho de Prótese/métodos , Tremor/reabilitação , Humanos , Masculino , Articulação do Punho
13.
Sensors (Basel) ; 20(1)2020 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-31947905

RESUMO

Sleep apnea (SA) is a prevalent disorder diagnosed by polysomnography (PSG) based on the number of apnea-hypopnea events per hour of sleep (apnea-hypopnea index, AHI). PSG is expensive and technically complex; therefore, its use is rather limited to the initial diagnostic phase and simpler devices are required for long-term follow-up. The validity of single-parameter wearable devices for the assessment of sleep apnea severity is still debated. In this context, a wearable electrocardiogram (ECG) acquisition system (ECG belt) was developed and its suitability for the classification of sleep apnea severity was investigated using heart rate variability analysis with or without data pre-filtering. Several classification algorithms were compared and support vector machine was preferred due to its simplicity and overall performance. Whole-night ECG signals from 241 patients with a suspicion of sleep apnea were recorded using both the ECG belt and patched ECG during PSG recordings. 65% of patients had an obstructive sleep apnea and the median AHI was 21 [IQR: 7-40] h - 1 . The classification accuracy obtained from the ECG belt (accuracy: 72%, sensitivity: 70%, specificity: 74%) was comparable to the patched ECG (accuracy: 74%, sensitivity: 88%, specificity: 61%). The highest classification accuracy was obtained for the discrimination between individuals with no or mild SA vs. moderate to severe SA. In conclusion, the ECG belt provided signals comparable to patched ECG and could be used for the assessment of sleep apnea severity, especially during follow-up.


Assuntos
Técnicas Biossensoriais , Eletrocardiografia , Monitorização Fisiológica/métodos , Síndromes da Apneia do Sono/fisiopatologia , Adulto , Algoritmos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/métodos , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/classificação , Síndromes da Apneia do Sono/diagnóstico , Máquina de Vetores de Suporte , Dispositivos Eletrônicos Vestíveis
14.
Macromol Rapid Commun ; 40(21): e1900360, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31523877

RESUMO

The fluorescent dye 8-hydroxypyrene-1,3,6-trisulfonate (pyranine) combines high photostability with ratiometric pH detection in the physiological range, making it a prime candidate for optical sensors in biomedical applications, such as pH-based chronic wound monitoring. However, pyranine's high water solubility and the difficulty of covalent attachment pose severe limitations in terms of leaching from sensor matrices. Herein, pyranine-modified nanophase-separated amphiphilic polymer conetworks (APCNs) are reported as fluorescent ratiometric pH sensors. The thin, freestanding APCN membranes composed of one hydrophilic and one hydrophobic polymer provide an optically transparent, flexible, and stable ideal matrix that enables contact between dye and aqueous environment. An active ester-based conjugation approach results in a highly homogeneous and stable pyranine modification of the APCN's hydrophilic phase. This concept effectively solves the leaching challenge for pyranine without compromising its functionality, which is demonstrated by ratiometric pH detection in the range of pH 5-9.


Assuntos
Sulfonatos de Arila/química , Corantes Fluorescentes/química , Polímeros/química , Tensoativos/química , Concentração de Íons de Hidrogênio , Estrutura Molecular , Tamanho da Partícula , Propriedades de Superfície
15.
Sensors (Basel) ; 19(13)2019 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-31288468

RESUMO

The objective of this paper is to study the ability of polymer optical fiber (POF) to be inserted in a knitted fabric and to measure both pressure and friction when walking. Firstly, POF, marketed and in development, have been compared in terms of the required mechanical properties for the insertion of the fiber directly into a knitted fabric on an industrial scale, i.e. elongation, bending rigidity, and minimum bending radius before plastic deformation. Secondly, the chosen optical fiber was inserted inside several types of knitted fabric and was shown to be sensitive to friction and compression. The knitted structure with the highest sensitivity has been chosen for sock prototype manufacturing. Finally, a feasibility study with an instrumented sock showed that it is possible to detect the different phases of walking in terms of compression and friction.


Assuntos
Vestuário , Monitorização Fisiológica/instrumentação , Fibras Ópticas , Têxteis , Acelerometria , Desenho de Equipamento , Fricção , Humanos , Monitorização Fisiológica/métodos , Polímeros , Pressão , Reprodutibilidade dos Testes , Caminhada
16.
Sensors (Basel) ; 19(11)2019 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-31141955

RESUMO

Even for 1-lead electrocardiography (ECG), single-use gel conductive electrodes are employed in a clinical setting. However, gel electrodes show limited applicability for long-term monitoring due to skin irritation and detachment. In the present study, we investigated the validity of a textile ECG-belt suitable for long-term measurements in clinical use. In order to assess the signal quality and validity of the ECG-belt during sleep, 242 patients (186 males and 56 females, age 52 (interquartile range 42-60) years, body mass index 29 (interquartile range 26-33) kg·m-2) with suspected sleep apnoea underwent overnight polysomnography including standard 1-lead ECG recording. The single intervals between R-peaks (RR-intervals) were calculated from the ECG-signals. We found a mean difference for average RR-intervals of -2.9 ms, a standard error of estimate of 0.39%, as well as a Pearson r of 0.91. Furthermore, we found that the validity of the ECG-belt decreases when lying on the side, which was potentially due to the fitting of the belt. In conclusion, the validity of RR-interval measurements using the ECG-belt is high and it may be further improved for future applications by optimizing wear fitting.


Assuntos
Eletrocardiografia , Monitorização Fisiológica , Têxteis , Adulto , Artefatos , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura , Razão Sinal-Ruído , Síndromes da Apneia do Sono/diagnóstico , Análise de Ondaletas
17.
Sensors (Basel) ; 19(15)2019 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-31370241

RESUMO

Sleep monitoring in an unattended home setting provides important information complementing and extending the clinical polysomnography findings. The validity of a wearable textile electrocardiography (ECG)-belt has been proven in a clinical setting. For evaluation in a home setting, ECG signals and features were acquired from 12 patients (10 males and 2 females, showing an interquartile range for age of 48-59 years and for body mass indexes (BMIs) of 28.0-35.5) over 28 nights. The signal quality was assessed by artefacts detection, signal-to-noise ratio, and Poincaré plots. To assess the validity, the data were compared to previously reported data from the clinical setting. It was found that the artefact percentage was slightly reduced for the ECG-belt from 9.7% ± 14.7% in the clinical setting, to 7.5% ± 10.8% in the home setting. The signal-to-noise ratio was improved in the home setting and reached similar values to the gel electrodes in the clinical setting. Finally, it was found that for artefact percentages above 3%, Poincaré plots are instrumental to evaluate the origin of artefacts. In conclusion, the application of the ECG-belt in a home setting did not result in a reduction in signal quality compared to the ECG-belt used in the clinical setting, and thus provides new opportunities for patient pre-screening or follow-up.


Assuntos
Eletrocardiografia/métodos , Monitorização Fisiológica , Polissonografia/métodos , Síndromes da Apneia do Sono/diagnóstico , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Sono/fisiologia , Síndromes da Apneia do Sono/fisiopatologia , Têxteis , Dispositivos Eletrônicos Vestíveis
18.
Int J Biometeorol ; 62(7): 1121-1134, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29478101

RESUMO

To evaluate the quality of new energy-saving and performance-supporting building and urban settings, the thermal sensation and comfort models are often used. The accuracy of these models is related to accurate prediction of the human thermo-physiological response that, in turn, is highly sensitive to the local effect of clothing. This study aimed at the development of an empirical regression model of the air gap thickness and the contact area in clothing to accurately simulate human thermal and perceptual response. The statistical model predicted reliably both parameters for 14 body regions based on the clothing ease allowances. The effect of the standard error in air gap prediction on the thermo-physiological response was lower than the differences between healthy humans. It was demonstrated that currently used assumptions and methods for determination of the air gap thickness can produce a substantial error for all global, mean, and local physiological parameters, and hence, lead to false estimation of the resultant physiological state of the human body, thermal sensation, and comfort. Thus, this model may help researchers to strive for improvement of human thermal comfort, health, productivity, safety, and overall sense of well-being with simultaneous reduction of energy consumption and costs in built environment.


Assuntos
Regulação da Temperatura Corporal , Sensação Térmica , Vestuário , Arquitetura de Instituições de Saúde , Humanos , Manequins , Modelos Teóricos
19.
Int J Biometeorol ; 62(10): 1861-1872, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30062610

RESUMO

Contact skin temperature (Tsk) sensors are calibrated under uniform thermal conditions but used in the presence of a skin-to-environment temperature gradient. We aimed to characterise the validity of contact Tsk sensors when measuring surface temperature under a range of environmental and fabric coverage conditions, to estimate practical temperature limits for a given measurement bias and to explore correcting for bias. Using two types of contact Tsk sensors (thermistors, n = 5; iButtons, n = 5), we performed experiments in three phases: (1) conventional calibration (uniform thermal environment) over 15-40 °C in 5 °C steps (at t = 0, and 24 h, 12 weeks later), (2) surface temperature measurements of a purpose-made aluminium plate (also 15-40 °C) at different environmental temperatures (15, 25, 35 °C) with different sensor attachments and fabric coverings to assess measurement bias and calculate correction factors that account for the next-to-surface microclimate temperature and (3) surface measurements (33.1 °C in 20 °C environment) for assessing generated corrections. The main results were as follows: (1) after initial calibration, Tsk sensors were valid under uniform thermal conditions [mean bias < 0.05 °C, typical error of the estimate < 0.1 °C]. (2) For the surface measurements, bias increased with increasing surface-to-microclimate temperature difference for both sensor types. The range of surface temperatures possible to remain within given bias limits could be estimated for the various conditions. (3) For a given measurement, using corrections encompassing the microclimate temperature (mean difference - 0.1 to 0.5 °C) performed better than conventional calibration alone (mean difference - 2.1 to - 0.3 °C). In conclusion, the bias of Tsk sensors is influenced by the microclimate temperature and, therefore, body coverings. Where excessive bias is expected, the validity can be improved through sensor and attachment selection and by applying corrections that account for the local temperature gradient.


Assuntos
Microclima , Temperatura Cutânea , Dispositivos Eletrônicos Vestíveis/normas , Temperatura Corporal , Calibragem , Humanos , Temperatura
20.
Int J Biometeorol ; 61(2): 363-375, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27522664

RESUMO

The heat and mass transfer in clothing is predominantly dependent on the thickness of air layer and the magnitude of contact area between the body and the garment. The air gap thickness and magnitude of the contact area can be affected by the posture of the human body. Therefore, in this study, the distribution of the air gap and the contact area were investigated for different body postures of a flexible manikin. In addition, the effect of the garment fit (regular and loose) and style (t-shirts, sweatpants, jacket and trousers) were analysed for the interaction between the body postures and the garment properties. A flexible manikin was scanned using a three-dimensional (3D) body scanning technique, and the scans were post-processed in dedicated software. The body posture had a strong effect on the air gap thickness and the contact area for regions where the garment had a certain distance from the body. Furthermore, a mathematical model was proposed to estimate the possible heat transfer coefficient for the observed air layers and their change with posture. The outcome of this study can be used to improve the design of the protective and functional garments and predict their effect on the human body.


Assuntos
Regulação da Temperatura Corporal , Vestuário , Modelos Teóricos , Postura , Ar , Humanos , Manequins , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA