Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Public Health ; 200: 71-76, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34710716

RESUMO

OBJECTIVES: To analyse the impact of hospital quality indicators on hip fracture mortality in Israel. STUDY DESIGN: A retrospective observational study. METHODS: Data were collected on all patients aged ≥65 years with an isolated hip fracture in the years 2010-2016 from the Israel's National Trauma Registry. These data were then cross checked with information on co-morbidities and medication intake from the Clalit medical fund. All successfully matched patients constituted the study population. The main outcome measures were in-hospital and 1-year mortality. Trend analysis of surgery on hip fractures within 48 h of hospitalisation (referred to as early hip fracture surgeries) and mortality was performed. The introduction of the proportion of early hip fracture surgeries as an official quality parameter in 2013 was considered an intervention. RESULTS: The proportion of early hip fracture surgeries continuously increased during the study period and, after the introduction of the quality measure, a significant increase in the uniformity of practice among hospitals was observed. The mortality trend was not related to the early surgeries trend, with a sharp upward spike detected in 2014, followed by a gradual return to previous levels in the subsequent years. The analysis has shown that when adjusting for demographic factors and co-morbidity, both in 2010-2013 and in 2015-2016, a clear benefit in survival existed for patients who were operated on within the first 48 h. In 2014, which was the first year of open publication of achieved quality measures reported in the media, no such benefit was found. CONCLUSIONS: Even when an improvement in a promoted practice is achieved, its positive impact on clinical outcomes may be delayed, possibly indicating the need for a learning period.


Assuntos
Fraturas do Quadril , Indicadores de Qualidade em Assistência à Saúde , Fraturas do Quadril/cirurgia , Hospitalização , Hospitais , Humanos , Estudos Retrospectivos
2.
Brain Inj ; 30(10): 1194-200, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27466967

RESUMO

BACKGROUND: TBI may be defined by different methods. Some may be most useful for immediate clinical purposes, however less optimal for epidemiologic research. Other methods, such as the Abbreviated Injury Score (AIS), may prove more beneficial for this task, if the cut-off-points for their categories are defined correctly. OBJECTIVE: To reveal the optimal cut-off-points for AIS in definition of severity of TBI in order to ensure uniformity between future studies of TBI. RESULTS: Mortality of patients with TBI AIS 3, 4 was 1.9% and 2.9% respectively, comparing with 31.1% among TBI AIS 5+. Predictive discrimination ability of the model with cut-off-points of 5+ for TBI AIS (in comparison with other cut-off-points) was better. Patients with missing Glasgow Coma Scale (GCS) in the ED had an in-hospital mortality rate of 11.5%. In this group, 25% had critical TBI according to AIS. Normal GCS didn't indicate an absence of head injury, as, among patients with GCS 15 in the ED, 26% had serious/critical TBI injury. Moreover, 7% of patients with multiple injury and GCS 3-8 had another reason than head injury for unconsciousness. CONCLUSIONS: This study recommends the adoption of an AIS cut-off ≥ 5 as a valid definition of severe TBI in epidemiological studies, while AIS 3-4 may be defined as 'moderate' TBI and AIS 1-2 as 'mild'.


Assuntos
Lesões Encefálicas Traumáticas/diagnóstico , Lesões Encefálicas Traumáticas/mortalidade , Escala Resumida de Ferimentos , Adolescente , Lesões Encefálicas Traumáticas/epidemiologia , Criança , Pré-Escolar , Feminino , Escala de Coma de Glasgow , Mortalidade Hospitalar , Humanos , Lactente , Recém-Nascido , Modelos Logísticos , Masculino , Sistema de Registros , Estudos Retrospectivos , Inconsciência
3.
AJNR Am J Neuroradiol ; 37(2): 290-3, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26338918

RESUMO

BACKGROUND AND PURPOSE: Autosomal dominant polycystic kidney disease is associated with an increased risk of intracranial aneurysms. Our purpose was to assess whether there is an increased risk during aneurysm coiling and clipping. MATERIALS AND METHODS: Data were obtained from the National Inpatient Sample (2000-2011). All subjects had an unruptured aneurysm clipped or coiled and were divided into polycystic kidney (n = 189) and control (n = 3555) groups. Primary end points included in-hospital mortality, length of stay, and total hospital charges. Secondary end points included the International Classification of Diseases, Ninth Revision codes for iatrogenic hemorrhage or infarction; intracranial hemorrhage; embolic infarction; and carotid and vertebral artery dissections. RESULTS: There was a significantly greater incidence of iatrogenic hemorrhage or infarction, embolic infarction, and carotid artery dissection in the patients with polycystic kidney disease compared with the control group after endovascular coiling. There was also a significantly greater incidence of iatrogenic hemorrhage or infarction in the polycystic kidney group after surgical clipping. However, the hospital stay was not longer in the polycystic kidney group, and the total hospital charges were not higher. Additional analysis within the polycystic kidney group revealed a significantly shorter length of stay but similar in-hospital costs when subjects underwent coiling versus clipping. CONCLUSIONS: Patients with polycystic kidney disease face an increased risk during intracranial aneurysm treatment, whether by coiling or clipping. This risk, however, does not translate into longer hospital stays or increased hospital costs. Despite the additional catheterization-related risks of dissection and embolization, coiling results in shorter hospital stays and similar mortality compared with clipping.


Assuntos
Embolização Terapêutica/efeitos adversos , Aneurisma Intracraniano/cirurgia , Procedimentos Neurocirúrgicos/efeitos adversos , Rim Policístico Autossômico Dominante/complicações , Complicações Pós-Operatórias/epidemiologia , Adulto , Idoso , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Feminino , Custos Hospitalares , Humanos , Incidência , Pacientes Internados , Aneurisma Intracraniano/etiologia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/instrumentação , Procedimentos Neurocirúrgicos/métodos , Fatores de Risco , Instrumentos Cirúrgicos , Resultado do Tratamento
4.
Arch Dermatol ; 113(4): 472-6, 1977 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-848976

RESUMO

Eccrine poromatosis (EP) of remarkable severity has been observed in a patient with hidrotic ectodermal dysplasia (HED), a member of the kindred originally described by Clouston. Neither the EP nor its association with HED has been previously reported.


Assuntos
Glândulas Écrinas , Displasia Ectodérmica/diagnóstico , Neoplasias das Glândulas Sudoríparas/diagnóstico , Glândulas Sudoríparas , Adulto , Glândulas Écrinas/patologia , Displasia Ectodérmica/patologia , Feminino , Dermatoses do Pé/diagnóstico , Dermatoses do Pé/patologia , Dermatoses da Mão/diagnóstico , Dermatoses da Mão/patologia , Humanos , Hiperplasia , Pele/patologia , Neoplasias das Glândulas Sudoríparas/patologia , Glândulas Sudoríparas/patologia
5.
Arch Dermatol ; 118(1): 40-1, 1982 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-7059199

RESUMO

Metastases to the skin from internal malignant neoplasms are an uncommon and often preterminal event. Cutaneous metastases from a carcinoma of the uterine cervix, however, have rarely been reported, even in the advanced stages of the disease. A patient was initially seen with cutaneous metastases and was found to have an extensive tumor in the pelvis, which proved to be a squamous cell carcinoma arising in the cervix.


Assuntos
Carcinoma de Células Escamosas/secundário , Neoplasias Cutâneas/secundário , Neoplasias do Colo do Útero/patologia , Abdome , Idoso , Carcinoma de Células Escamosas/patologia , Feminino , Humanos , Prognóstico , Pele/patologia , Neoplasias Cutâneas/patologia
6.
Thromb Res ; 78(2): 173-87, 1995 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-7482434

RESUMO

Influence of the end fibrinogen-derived DH, DL and E fragments on fibrinolysis and fibrinogenolysis has been studied. Electrophoresis of the plasmin-digested unstabilized fibrin and fibrinogen showed that fragment E was the only inhibitor of plasmin hydrolysis of fibrinogen, the antifibrinolytic activity of the fragments being increased in a DL < E < DH series. The fragments were revealed by means of elastic light scattering and analytical ultracentrifugation to be arranged in a E > DL > DH series by their ability to form a complex with plasminogen. It was concluded that the complex formation did not greatly contribute to the mechanism of fibrinolysis inhibition. Antifibrinolytic effect of fragment DH is due to its antipolymerization activity. The paper discusses the competitive protein-protein interactions occurring on a polymeric matrix of fibrin.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio/farmacologia , Fibrina/metabolismo , Fibrinogênio/metabolismo , Fibrinólise/efeitos dos fármacos , Depressão Química , Fibrinolisina/farmacologia , Humanos , Hidrólise , Plasminogênio/farmacologia , Trombina/farmacologia
7.
Med Phys ; 2(5): 274-7, 1975.
Artigo em Inglês | MEDLINE | ID: mdl-1186634

RESUMO

Readings made with condenser-ionization chamber systems are frequently suspect because significant changes in calibration can occur without being evident in the normal use of the instruments. These changes can be traced to physical causes that alter the voltage sensitivity of electrical capacitance. Thus, measurement of these electrical parameters will indicate whether or not a change in calibration has occurred. Formulas are presented of calculating such changes and determining which parameter is responsible. Good agreement was obtained between the results of calculations with these formulas and the results of radiation measurements made with a Victoreen Condenser R-Meter after several components had been deliberately maladjusted.


Assuntos
Monitoramento de Radiação/instrumentação , Modelos Teóricos , Monitoramento de Radiação/normas
8.
Med Phys ; 13(5): 751-4, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3785005

RESUMO

Cylindrical ionization chamber descriptions and physical dimensions that are necessary for the calculation of Awall and Ngas are presented. Also included are the corresponding calculated values of Awall and Ngas/(NxAion).


Assuntos
Radiometria/instrumentação , Humanos , Dosagem Radioterapêutica
9.
Med Phys ; 8(3): 292-301, 1981.
Artigo em Inglês | MEDLINE | ID: mdl-7322053

RESUMO

Fission track detectors were applied to a unique problem in neutron dosimetry. Measurements of neutron doses were required at locations within a tumor of 1 cm diameter implanted on the back of a mouse and surrounded by a square array of four 252Cf medical sources. Measurements made in a tissue-equivalent mouse phantom showed that the neutron dose rate to the center of the tumor was 2.18 rads micrograms-1 h-1 +/- 8.4%. The spatial variation of neutron dose to the tumor ranged from 1.88 to 2.55 rads micrograms-1 h-1. These measurements agree with calculated values of neutron dose to those locations in the phantom. Fission track detectors have been found to be a reliable tool for neutron dosimetry for geometries in which one wishes to know neutron dose values which may vary considerably over distances of 1 cm or less.


Assuntos
Califórnio/uso terapêutico , Dosimetria Fotográfica/instrumentação , Teleterapia por Radioisótopo/métodos , Animais , Nêutrons Rápidos , Fibrossarcoma/radioterapia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Cimento de Policarboxilato , Dosagem Radioterapêutica , Sarcoma Experimental/radioterapia
10.
Med Phys ; 3(6): 403-9, 1976.
Artigo em Inglês | MEDLINE | ID: mdl-1004398

RESUMO

Our investigations of an iso-octane-filled liquid-dielectric ionization chamber indicate that this dosimeter is well suited for the measurement of dose distributions at distances close to 252Cf interstitial implant sources. Initial research has shown that such an instrument provides good discrimination between the radiation components of a mixed field and possesses excellent sensitivity. Calculations indicate that iso-octane will yield a neutron and gamma-ray dose response independent of energy over a major part of the 252Cf spectral range, while transmission measurements have demonstrated that the liquid causes little perturbation of the radiation field.


Assuntos
Califórnio/uso terapêutico , Radiometria/instrumentação , Dosagem Radioterapêutica , Tecnologia Radiológica
11.
Med Phys ; 8(6): 877-81, 1981.
Artigo em Inglês | MEDLINE | ID: mdl-7322083

RESUMO

We have examined a number of analytic representations of electron central-axis depth dose data current in the literature, testing them against sets of standard depth dose data. One of them, a two-parameter model of Shabason and Hendee, is recommended in situations in which good accuracy (approximately 2%) is desired, with the values of the parameters determined by an approximation formula which we have developed elsewhere. For higher accuracy, we have developed a polynomial model which gives, typically, a standard deviation of the fitting polynomial from the data points of 1%, and a maximum deviation of 2%. Fitting polynomials obtained with this method possess the property of having zero slope at the position of actual maximum dose, and generally a fifth-order polynomial (requiring four nonzero coefficients) provided the most acceptable fit. The four parameters involved are determined through inversion of a 4 x 4 matrix, and we have tabulated these four coefficients for the standard data sets. The polynomial model is designed for interpolation in the range between the 100% dose depth and the 10% dose depth, and another fitting curve of the same type can be adjoined to cover depths less than the 100% dose depth.


Assuntos
Computadores , Elétrons , Radiometria/métodos , Radioterapia/métodos , Relação Dose-Resposta à Radiação , Humanos , Matemática
12.
Med Phys ; 10(3): 352-5, 1983.
Artigo em Inglês | MEDLINE | ID: mdl-6877182

RESUMO

Product representations are frequently used for teletherapy dose distributions. For example, the dose in a central plane is often written as the product of two factors, one dependent on the depth and the other on the transverse variable. We have answered the following question: given a (two-dimensional) set of data, how closely is it possible to represent these data by a product of two such factors, and what factors would give a best-fit representation? We thus have developed a quantitative test with which to judge any proposed product representation, for a given set of data. As an example, we have applied our method in analyzing the accuracy of a model proposed by van de Geijn for representing central-plane Cobalt-60 dose data through a product representation on decrement lines intersecting the source.


Assuntos
Dosagem Radioterapêutica , Humanos , Matemática
13.
Med Phys ; 12(3): 373-6, 1985.
Artigo em Inglês | MEDLINE | ID: mdl-4010643

RESUMO

The recently published AAPM Task Group 21 protocol for high-energy dosimetry is complicated in that it requires the physicist to obtain the values of about a dozen different physical variables by looking them up in tables or graphs. This should be compared with the procedure of earlier protocols using the concept of a single multiplier C lambda. We have investigated how the physical principles outlined in the improved AAPM protocol could be utilized for the redesign of the therapy-level ion chambers in such a way that one can reduce the number of factors that need to be looked up in tables or graphs for the calibration of high-energy teletherapy photon beams. In our analysis presented in this paper we found that one such design could be for an ion chamber having a wall acrylic or Bakelite of a thickness not exceeding 0.1 g/cm2 and having an inner diameter of 6 mm, and used in conjunction with a cobalt-60 buildup cap of thickness 0.35 g/cm2 made of acrylic, Bakelite, or Tufnol. If a chamber of such a design is used in a water phantom, the dosimetry practically reduces to the simplicity of the former protocols of depending on a single value of energy-dependent multiplier to be obtained from a table. With the above design parameters, it becomes possible to eliminate the explicit need to incorporate the factors Pwall, Prepl, Awall, beta wall, and the variable alpha, representing the fraction of ionization due to electrons from the wall material of the chamber.


Assuntos
Radiometria/instrumentação , Animais , Calibragem , Humanos , Modelos Estruturais , Monitoramento de Radiação
14.
Med Phys ; 14(6): 996-1006, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3696087

RESUMO

The Fermi-Eyges multiple-scattering theory for electrons is applied to calculate profiles of collimated electron beams. The dose profile below the collimator is a convolution of the intensity distribution of the electrons at the level of the collimator and the distribution arising from the propagation of a Gaussian point source from the collimator to the level of the calculation. The electrons at the level of the collimator possess an angular distribution characteristic of the configuration of the electron beam at the vacuum window. Hence, the dose profile and its associated penumbra width can be expressed in terms of the angular moments of the distribution of the electrons at the collimator. The dependence of the penumbra width on the configuration-dependent angular spread of the electrons at the collimator accounts for differences in the size of the penumbra between two broad-beam configurations. These differences are also seen experimentally. We have also studied the dependence of the angular moments of the electrons upon scattering foils present above the collimator and the position of the beam-broadening device in the accelerator head.


Assuntos
Teleterapia por Radioisótopo/métodos , Dosagem Radioterapêutica , Elétrons , Humanos , Matemática , Espalhamento de Radiação
15.
Med Phys ; 16(5): 712-25, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2509866

RESUMO

In this article in our series on electron dose calculation using multiple-scattering theory, we apply the Fermi-Eyges theory to the problem of a thin planar inhomogeneity present in an otherwise-layered medium. We derive expressions for the distribution function P and the location distribution L (which multiplied by the restricted mass collision stopping power is the dose directly deposited by the primary electrons) for various types of incident beams: a completely arbitrary distribution, a Gaussian point source, a pencil beam, an isotropic point source, and a broad parallel beam. We show how divergent-beam dose distributions can be determined from parallel-beam calculations, through use of equivalent configurations dependent upon the depth of dose calculation. Also, we indicate how this work can be applied to the design of wedges (or "compensators") for beam shaping to provide desired dose distributions or to match juxtaposed radiation fields. Explicit formulas for thin plates are then worked out, and we examine the appearance of hot and cold spots distal to the edge of a localized inhomogeneity, for thin half-slabs and for narrow strips. Finally, considering the case of a thin straight wedge-shaped inhomogeneity, we theoretically discover the phenomenon of a "focused hot spot" without an accompanying cold spot, and suggest the design of a "multiple-scattering lens".


Assuntos
Dosagem Radioterapêutica , Espalhamento de Radiação , Elétrons , Física Médica , Humanos , Modelos Teóricos , Radioterapia de Alta Energia
16.
Med Phys ; 24(8): 1249-54, 1997 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9284248

RESUMO

The American Association of Physicists in Medicine, through a subcommittee (formerly Task Group 3) of the Radiation Therapy Committee, has accredited five laboratories to perform calibrations of instruments used to calibrate therapeutic radiation beams. The role of the accredited dosimetry calibration laboratories (ADCLs) is to transfer a calibration factor from an instrument calibrated by the National Institute of Standards and Technology (NIST) to a customer's instrument. It is of importance to the subcommittee, to physicists using the services of the ADCLs, and to the ADCLs themselves, to know the uncertainty of instrument calibrations. The calibration uncertainty has been analyzed by asking the laboratories to provide information about their calibration procedures. Estimates of uncertainty by two procedures were requested: Type A are uncertainties derived as the standard deviations of repeated measurements, while type B are estimates of uncertainties obtained by other methods, again expressed as standard deviations. Data have been received describing the uncertainty of each parameter involved in calibrations, including those associated with measurements of charge, exposure time, and air density, among others. These figures were combined with the uncertainty of NIST calibrations, to arrive at an overall uncertainty which is expressed at the two-standard deviation level. For cable-connected instruments in gamma-ray and x-ray beams of HVL > 1 mm Al, the figure has an upper bound of approximately 1.2%.


Assuntos
Laboratórios , Radiometria/normas , Planejamento da Radioterapia Assistida por Computador/normas , Fenômenos Biofísicos , Biofísica , Estudos de Avaliação como Assunto , Humanos , Neoplasias/radioterapia , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Sociedades Científicas , Estados Unidos
17.
AJNR Am J Neuroradiol ; 35(1): 3-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23292526

RESUMO

Autosomal dominant polycystic kidney disease is a genetic disorder affecting 1 in 1000 people worldwide and is associated with an increased risk of intracranial aneurysms. It remains unclear whether there is sufficient net benefit to screening this patient population for IA, considering recent developments in imaging and treatment and our evolving understanding of the natural history of unruptured aneurysms. There is currently no standardized screening protocol for IA in patients with ADPCKD. Our review of the literature focused on the above issues and presents our appraisal of the estimated value of screening for IA in the setting of ADPCKD.


Assuntos
Angiografia Cerebral/estatística & dados numéricos , Aneurisma Intracraniano/diagnóstico , Aneurisma Intracraniano/epidemiologia , Programas de Rastreamento/métodos , Rim Policístico Autossômico Dominante/diagnóstico , Rim Policístico Autossômico Dominante/epidemiologia , Causalidade , Comorbidade , Medicina Baseada em Evidências , Humanos , Avaliação das Necessidades , Prevalência , Medição de Risco
18.
AJNR Am J Neuroradiol ; 37(2): 296, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26680457
19.
AJNR Am J Neuroradiol ; 31(1): 193-5, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19661171

RESUMO

A novel transosseous approach for percutaneous access of the lumbar subarachnoid space is described in a patient with advanced ankylosing spondylitis (AS) and instrumented spinal fusion who presented for myelography. Use of a coaxial threaded bone biopsy system to provide transosseous access to the thecal sac, imaging findings, and outcome are discussed. This technique provided access to an otherwise inaccessible subarachnoid space and is an alternative approach in the setting of advanced AS or posterior spinal fusion.


Assuntos
Vértebras Lombares , Fusão Vertebral/métodos , Espondilite Anquilosante/cirurgia , Adulto , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA