Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38984656

RESUMO

More than mild paravalvular leak (PVL) following transcatheter aortic valve implantation (TAVI) is associated with a twofold increase in all-cause mortality, heart failure hospitalizations, and the need for reintervention. Successfully addressing PVL in TAVIs is more challenging than in surgical valves. The arterial-arterial (A-A) rail technique emerges as a valuable strategy for post-TAVI PVL closure, enhancing success rates by enabling the effective use of lower-profile vascular plug devices. When standard approach is ineffective, generating an A-A loop for post-TAVI PVL closure is probably the most recommended strategy to ensure procedural success.

3.
JACC Cardiovasc Interv ; 17(4): 552-560, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38418058

RESUMO

BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) abolishes tricuspid regurgitation (TR) and has emerged as a definitive treatment for TR. OBJECTIVES: The purpose of this multicenter, observational study was to determine the clinical characteristics and short-term outcomes of patients with TR screened for TTVR. METHODS: Patients underwent TTVR screening at 7 centers on a compassionate-use basis. The primary endpoints were NYHA functional class and TR grade at 30-day follow-up. Secondary endpoints included all-cause mortality, heart failure hospitalization, technical success, and reasons for TTVR screening failure. RESULTS: A total of 149 patients (median age 79 years [Q1-Q3: 72-84 years], 54% women) underwent TTVR screening. The TTVR screening failure rate was 74%, mainly related to large tricuspid annular diameter. Patients undergoing TTVR (n = 38) had significant functional improvements (NYHA functional class I or II from 21% to 68%; P < 0.001), with TR ≤1+ in 97% at 30-day follow-up (P < 0.001 from baseline). Technical success was achieved in 91%, with no intraprocedural mortality or conversion to surgery. At 30-day follow-up, mortality was 8%, heart failure hospitalization 5%, major bleeding 18%, and reintervention 9%. Patients who failed screening for TTVR and subsequently underwent "bailout" transcatheter edge-to-edge repair (n = 26) had favorable outcomes (NYHA functional class I or II from 27% to 58%; P < 0.001), with TR ≤1+ in 43% at 30-day follow-up (P < 0.001 from baseline). CONCLUSIONS: This first real-world report of TTVR screening demonstrated a high screening failure rate, mainly related to large tricuspid annular diameter. Patients undergoing TTVR had superior TR reduction and symptom alleviation compared with bailout tricuspid transcatheter edge-to-edge repair, at the cost of greater procedural complications.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Recuperação de Função Fisiológica , Fatores de Tempo , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA