Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ultraschall Med ; 31(1): 53-62, 2010 Feb.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-19582661

RESUMO

PURPOSE: Conventional sonography at 2 - 10 MHz cannot permeate the chest because ultrasound at this frequency is strongly scattered and reflected by air inclusions in the lungs. Therefore, sonography is considered impracticable for thoracic imaging. However, human thoraxes and lungs in situ were never rigorously probed with ultrasound at frequencies below 1 MHz. In addition, ultrasound is commonly applied as echo imaging rather than sound transmission. MATERIALS AND METHODS: Human subjects were studied with a transducer detector pair or an elastic thorax belt equipped with 12 sensors 5 cm apart that was wrapped around the thorax and a single pulse transmitter attached to the sternum. We focused on fast ultrasound transmission from 1 kHz to 1 MHz, coupled over thoracic sonotrodes. RESULTS: Between 1 Hz to 1 MHz, sound transmission through thorax and lungs shows three distinct bands: < 1 kHz sound is transmitted at 30 - 50 m/sec, between 1 - 10 kHz sound transmission is absent and > 10 kHz sound is transmitted with a speed of 1500 m/sec. We demonstrate that low-frequency ultrasound (10 - 750 kHz) can permeate the thorax and permits monitoring of the air and water content of human lungs. In healthy subjects at 15 kHz, the difference in sound transmission through thorax and lungs between inspiration and expiration was dynamic and spanned several decades. Sound transmission during expiration was strongly decreased in patients suffering from pulmonary emphysema or pneumothorax, but increased in patients with pleural effusions. CONCLUSION: Sound transmission in the lungs is characterized by three distinct frequency bands. Low frequency ultrasound is transmitted through the lungs and may offer a novel non-invasive approach to real time diagnostics.


Assuntos
Água Extravascular Pulmonar/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/instrumentação , Pneumopatias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Monitorização Fisiológica/instrumentação , Enfisema Pulmonar/diagnóstico por imagem , Transdutores , Ultrassonografia/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Expiração/fisiologia , Feminino , Humanos , Inalação/fisiologia , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Derrame Pleural/diagnóstico por imagem , Pneumotórax/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Fibrose Pulmonar/diagnóstico por imagem , Valores de Referência , Sarcoidose Pulmonar/diagnóstico por imagem , Sensibilidade e Especificidade , Espectrografia do Som/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA