Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Proc Inst Mech Eng H ; 227(1): 27-36, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23516953

RESUMO

Unicondylar knee replacement systems have been shown to perform comparably to total knee replacements, while being much less surgically invasive. Proper ligament balancing, as well as knee laxity, has been shown to play an important role in optimizing kinematic behavior of these implant systems and improving long-term survival of the implant. This study investigates the effect of different simulated ligament laxity conditions of the anterior cruciate ligament and the posterior cruciate ligament on the resulting anteroposterior and mediolateral contact kinematics for medial and lateral pairs of UKR implants with flat and symmetric ultrahigh-molecular-weight polyethylene inserts during force-controlled ISO-14243-1 knee testing simulation. A novel method of capturing the tibiofemoral lowest point contact path was used to calculate the shear plane lowest point contact path kinematics in both the anteroposterior and the mediolateral directions. The results illustrated that multiple clinically relevant soft tissue configurations produce statistically different measured knee kinematics in unicondylar knee replacement systems than is seen in accepted "standard" knee simulator protocols with 95% confidence interval. The observed kinematic differences in anteroposterior and mediolateral movement from what was observed using standard wear testing protocols could aid in the development of unicondylar knee replacement design enhancements that are resistant to varying soft tissue deficiencies.


Assuntos
Ligamento Cruzado Anterior/fisiopatologia , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Prótese do Joelho , Ligamento Cruzado Posterior/fisiopatologia , Ligamento Cruzado Anterior/cirurgia , Simulação por Computador , Humanos , Modelos Biológicos , Ligamento Cruzado Posterior/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
2.
Vet Surg ; 42(2): 217-22, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23373750

RESUMO

OBJECTIVE: To determine acute load to failure (ALF) and suture abrasion (SA) at 0° and 90° for a novel screw-type mini-anchor design. STUDY DESIGN: Biomechanical in vitro study. SAMPLE POPULATION: Synthetic bone. METHODS: Twenty mini-anchors were inserted into synthetic bone blocks assigned to 1 of 2 groups (0° ALF, 90° ALF). Pullout was performed at 5 mm/min. ALF, yield strength and stiffness were calculated. SA constructs were created with 4 groups of 5 anchors each with either 30 lb nylon leader line (NLL), 40 lb NLL, #2 Fiberwire or #5 Fiberwire. SA was performed at 0° and 90° with a sinusoidal wave form at 0.5 Hz and 10 N load for 1000 cycles or until failure. Data were summarized as mean ± SD. ALF data were analyzed using t-tests. SA data were analyzed using log rank, Tukey-adjusted pairwise comparisons and sign tests. Significance was set at P = .05. RESULTS: Mean ± SD ALF at 0° and 90° was 431.8 ± 70.8 N and 683 ± 48.7 N, respectively. 90° ALF was significantly higher. Yield strength and stiffness were not significantly different at 0° and 90°. #5 and #2 Fiberwire survived significantly more cycles than 40 lb and 30 lb NLL at 90°. At 0°, 30 lb NLL survived significantly less cycles than either Fiberwire size. Suture orientation did not have a significant effect on SA for Fiberwire constructs. CONCLUSION: The novel mini-anchor has ALF comparable to other mini-anchors. Fiberwire survived more cycles in the novel anchor eyelet than NLL and FW suture orientation in the eyelet did not affect SA.


Assuntos
Parafusos Ósseos/veterinária , Animais , Fenômenos Biomecânicos , Parafusos Ósseos/normas , Osso e Ossos/cirurgia , Falha de Equipamento , Técnicas In Vitro , Suturas/normas , Suturas/veterinária , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA