1.
Clin Orthop Relat Res ; 480(6): 1191-1204, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35202032

RESUMO

BACKGROUND: Currently used prosthetic solutions in upper extremity amputation have limited functionality, owing to low information transfer rates of neuromuscular interfacing. Although surgical innovations have expanded the functional potential of the residual limb, available interfaces are inefficacious in translating this potential into improved prosthetic control. There is currently no implantable solution for functional interfacing in extremity amputation which offers long-term stability, high information transfer rates, and is applicable for all levels of limb loss. In this study, we presented a novel neuromuscular implant, the the Myoelectric Implantable Recording Array (MIRA). To our knowledge, it is the first fully implantable system for prosthetic interfacing with a large channel count, comprising 32 intramuscular electrodes. QUESTIONS/PURPOSES: The purpose of this study was to evaluate the MIRA in terms of biocompatibility, functionality, and feasibility of implantation to lay the foundations for clinical application. This was achieved through small- and large-animal studies as well as test surgeries in a human cadaver. METHODS: We evaluated the biocompatibility of the system's intramuscular electromyography (EMG) leads in a rabbit model. Ten leads as well as 10 pieces of a biologically inert control material were implanted into the paravertebral muscles of four animals. After a 3-month implantation, tissue samples were taken and histopathological assessment performed. The probes were scored according to a protocol for the assessment of the foreign body response, with primary endpoints being inflammation score, tissue response score, and capsule thickness in µm. In a second study, chronic functionality of the full system was evaluated in large animals. The MIRA was implanted into the shoulder region of six dogs and three sheep, with intramuscular leads distributed across agonist and antagonist muscles of shoulder flexion. During the observation period, regular EMG measurements were performed. The implants were removed after 5 to 6 months except for one animal, which retained the implant for prolonged observation. Primary endpoints of the large-animal study were mechanical stability, telemetric capability, and EMG signal quality. A final study involved the development of test surgeries in a fresh human cadaver, with the goal to determine feasibility to implant relevant target muscles for prosthetic control at all levels of major upper limb amputation. RESULTS: Evaluation of the foreign body reaction revealed favorable biocompatibility and a low-grade tissue response in the rabbit study. No differences regarding inflammation score (EMG 4.60 ± 0.97 [95% CI 4.00 to 5.20] versus control 4.20 ± 1.48 [95% CI 3.29 to 5.11]; p = 0.51), tissue response score (EMG 4.00 ± 0.82 [95% CI 3.49 to 4.51] versus control 4.00 ± 0.94 [95% CI 3.42 to 4.58]; p > 0.99), or thickness of capsule (EMG 19.00 ± 8.76 µm [95% CI 13.57 to 24.43] versus control 29.00 ± 23.31 µm [95% CI 14.55 to 43.45]; p = 0.29) were found compared with the inert control article (high-density polyethylene) after 3 months of intramuscular implantation. Throughout long-term implantation of the MIRA in large animals, telemetric communication remained unrestricted in all specimens. Further, the implants retained the ability to record and transmit intramuscular EMG data in all animals except for two sheep where the implants became dislocated shortly after implantation. Electrode impedances remained stable and below 5 kΩ. Regarding EMG signal quality, there was little crosstalk between muscles and overall average signal-to-noise ratio was 22.2 ± 6.2 dB. During the test surgeries, we found that it was possible to implant the MIRA at all major amputation levels of the upper limb in a human cadaver (the transradial, transhumeral, and glenohumeral levels). For each level, it was possible to place the central unit in a biomechanically stable environment to provide unhindered telemetry, while reaching the relevant target muscles for prosthetic control. At only the glenohumeral level, it was not possible to reach the teres major and latissimus dorsi muscles, which would require longer lead lengths. CONCLUSION: As assessed in a combination of animal model and cadaver research, the MIRA shows promise for clinical research in patients with limb amputation, where it may be employed for all levels of major upper limb amputation to provide long-term stable intramuscular EMG transmission. CLINICAL RELEVANCE: In our study, the MIRA provided high-bandwidth prosthetic interfacing through intramuscular electrode sites. Its high number of individual EMG channels may be combined with signal decoding algorithms for accessing spinal motor neuron activity after targeted muscle reinnervation, thus providing numerous degrees of freedom. Together with recent innovations in amputation surgery, the MIRA might enable improved control approaches for upper limb amputees, particularly for patients with above-elbow amputation where the mismatch between available control signals and necessary degrees of freedom for prosthetic control is highest.


Assuntos
Membros Artificiais , Animais , Cadáver , Cães , Eletrodos Implantados , Eletromiografia , Estudos de Viabilidade , Humanos , Inflamação , Coelhos , Ovinos
2.
Sensors (Basel) ; 21(20)2021 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-34695957

RESUMO

Enriched environments and tools are believed to promote grasp rehabilitation after stroke. We designed S2, an interactive grasp rehabilitation system consisting of smart objects, custom orthoses for selective grasp constraining, and an electrode array system for forearm NMES. Motor improvements and perceived usability of a new enriched upper limb training system for sub-acute stroke patients was assessed in this interim analysis. INCLUSION CRITERIA: sub-acute stroke patients with MMSE>20, ipsilesional MI>80%, and contralesional MI<80%. Effects of 30-min therapy supplements, conventional vs. S2 prototype, are compared through a parallel two-arms dose-matched open-label trial, lasting 27 sessions. Clinical centres: Asklepios Neurologische Klinik Falkenstein, Königstein im Taunus, Germany, and Clinica Villa Beretta, Costa Masnaga, Italy. Assessment scales: ARAT, System Usability, and Technology Acceptance. METHODOLOGY: 26 participants were block randomized, allocated to the study (control N=12, experimental N=14) and underwent the training protocol. Among them, 11 participants with ARAT score at inclusion below 35, n = 6 in the experimental group, and n = 5 in the control group were analysed. RESULTS: participants in the enriched treatment group displayed a larger improvement in the ARAT scale (+14.9 pts, pval=0.0494). Perceived usability differed between clinics. No adverse effect was observed in relation to the treatments. Trial status: closed. CONCLUSIONS: The S2 system, developed according to shared clinical directives, was tested in a clinical proof of concept. Variations of ARAT scores confirm the feasibility of clinical investigation for hand rehabilitation after stroke.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Terapia por Exercício , Força da Mão , Humanos , Recuperação de Função Fisiológica , Resultado do Tratamento , Extremidade Superior
3.
J Neuroeng Rehabil ; 17(1): 99, 2020 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-32680530

RESUMO

Modern lower limb prostheses have the capability to replace missing body parts and improve the patients' quality of life. However, missing environmental information often makes a seamless adaptation to transitions between different forms of locomotion challenging. The aim of this review is to identify the progress made in this area over the last decade, addressing two main questions: which types of novel sensors for environmental awareness are used in lower limb prostheses, and how do they enhance device control towards more comfort and safety. A literature search was conducted on two Internet databases, PubMed and IEEE Xplore. Based on the criteria for inclusion and exclusion, 32 papers were selected for the review analysis, 18 of those are related to explicit environmental sensing and 14 to implicit environmental sensing. Characteristics were discussed with a focus on update rate and resolution as well as on computing power and energy consumption. Our analysis identified numerous state-of-the-art sensors, some of which are able to "look through" clothing or cosmetic covers. Five control categories were identified, how "next generation prostheses" could be extended. There is a clear tendency towards more upcoming object or terrain prediction concepts using all types of distance and depth-based sensors. Other advanced strategies, such as bilateral gait segmentation from unilateral sensors, could also play an important role in movement-dependent control applications. The studies demonstrated promising accuracy in well-controlled laboratory settings, but it is unclear how the systems will perform in real-world environments, both indoors and outdoors. At the moment the main limitation proves to be the necessity of having an unobstructed field of view.


Assuntos
Membros Artificiais , Dispositivos Eletrônicos Vestíveis , Humanos , Locomoção
4.
Sensors (Basel) ; 19(4)2019 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-30813494

RESUMO

Myoelectric prostheses help amputees to regain independence and a higher quality of life. These prostheses are controlled by state-of-the-art electromyography sensors, which use a conductive connection to the skin and are therefore sensitive to sweat. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Here, we present ultra-low-power digital signal processing algorithms for an insulated EMG sensor which couples the EMG signal capacitively. These sensors require neither conductive connection to the skin nor electrolytic paste or skin preparation. Capacitive sensors allow straightforward application. However, they make a sophisticated signal amplification and noise suppression necessary. A low-cost sensor has been developed for real-time myoelectric prostheses control. The major hurdles in measuring the EMG are movement artifacts and external noise. We designed various digital filters to attenuate this noise. Optimal system setup and filter parameters for the trade-off between attenuation of this noise and sufficient EMG signal power for high signal quality were investigated. Additionally, an algorithm for movement artifact suppression, enabling robust application in real-world environments, is presented. The algorithms, which require minimal calculation resources and memory, are implemented on an ultra-low-power microcontroller.


Assuntos
Eletromiografia/métodos , Algoritmos , Humanos , Qualidade de Vida , Processamento de Sinais Assistido por Computador
5.
Sensors (Basel) ; 19(4)2019 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-30813504

RESUMO

Electromyography (EMG), the measurement of electrical muscle activity, is used in a variety of applications, including myoelectric upper-limb prostheses, which help amputees to regain independence and a higher quality of life. The state-of-the-art sensors in prostheses have a conductive connection to the skin and are therefore sensitive to sweat and require preparation of the skin. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Due to their insulating layer between skin and sensor area, capacitive sensors are insensitive to the skin condition, they require neither conductive connection to the skin nor electrolytic paste or skin preparation. Here, we describe a highly stable, low-power capacitive EMG measurement set-up that is suitable for real-world application. Various flexible multi-layer sensor set-ups made of copper and insulating foils, flex print and textiles were compared. These flexible sensor set-ups adapt to the anatomy of the human forearm, therefore they provide high wearing comfort and ensure stability against motion artifacts. The influence of the materials used in the sensor set-up on the magnitude of the coupled signal was demonstrated based on both theoretical analysis and measurement.The amplifier circuit was optimized for high signal quality, low power consumption and mobile application. Different shielding and guarding concepts were compared, leading to high SNR.


Assuntos
Técnicas Biossensoriais/métodos , Eletromiografia/métodos , Membros Artificiais , Humanos , Qualidade de Vida
6.
Artif Organs ; 39(10): 855-62, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26471136

RESUMO

This is a case series study with the objective of comparing two motion sensor automated strategies to avert knee buckle during functional electrical stimulation (FES)-standing against a conventional hand-controlled (HC) FES approach. The research was conducted in a clinical exercise laboratory gymnasium at the University of Sydney, Australia. The automated strategies, Aut-A and Aut-B, applied fixed and variable changes of neurostimulation, respectively, in quadriceps amplitude to precisely control knee extension during standing. HC was an "on-demand" increase of stimulation amplitude to maintain stance. Finally, maximal FES amplitude (MA) was used as a control condition, whereby knee buckle was prevented by maximal isometric muscle recruitment. Four AIS-A paraplegics undertook 4 days of testing each, and each assessment day comprised three FES standing trials using the same strategy. Cardiorespiratory responses were recorded, and quadriceps muscle oxygenation was quantified using near-infrared spectroscopy. For all subjects, the longest standing times were observed during Aut-A, followed by Aut-B, and then HC and MA. The standing times of the automated strategies were superior to HC by 9-64%. Apart from a lower heart rates during standing (P = 0.034), the automation of knee extension did not promote different cardiorespiratory responses compared with HC. The standing times during MA were significantly shorter than during the automated or "on-demand" strategies (by 80-250%). In fact, the higher isometric-evoked quadriceps contraction during MA resulted in a greater oxygen demand (P < 0.0001) and wider arteriovenous oxygen extraction (P = 0.08) when compared with the other strategies. In conclusion, even though increased standing times were demonstrated using automated control of knee extension, physiological benefits compared with HC were not evident.


Assuntos
Terapia por Estimulação Elétrica/métodos , Músculo Esquelético/metabolismo , Miocárdio/metabolismo , Músculos Respiratórios/metabolismo , Traumatismos da Medula Espinal/terapia , Humanos , Pessoa de Meia-Idade , Movimento (Física) , Movimento/fisiologia , Consumo de Oxigênio/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho , Traumatismos da Medula Espinal/fisiopatologia
7.
Arch Phys Med Rehabil ; 94(5): 990-3, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23123504

RESUMO

OBJECTIVE: To investigate the long-term effects of functional electrical stimulation (FES)-evoked cycle training cadence on leg muscle hypertrophy and electrically evoked strength. DESIGN: Open intervention study. SETTING: Laboratory setting. PARTICIPANTS: Untrained individuals with chronic spinal cord injury (N=8). INTERVENTIONS: Six weeks (3d/wk) of training on an isokinetic FES cycle ergometer. For each subject, 1 leg was randomly allocated to cycling at 10 revolutions per minute (rpm) (LOW) for 30min/d, and the other cycling at 50rpm (HIGH) for 30min/d. MAIN OUTCOME MEASURES: Pre- and posttraining measurements of lower limb circumference were performed at the distal and middle position of each thigh. Electrically evoked quadriceps muscle torque during an isometric contraction was also assessed. RESULTS: Six weeks of FES cycle training significantly increased thigh girth in both LOW and HIGH groups. At midthigh, girth increases induced by LOW (6.6%±1.2%) were significantly greater than those by HIGH (3.6%±0.8%). LOW also produced greater gains in electrically evoked isometric torque than HIGH after training. CONCLUSIONS: These results suggest that lower pedaling cadences evoke greater muscle hypertrophy and electrically stimulated muscle strength compared with higher cadences.


Assuntos
Terapia por Estimulação Elétrica/métodos , Terapia por Exercício/métodos , Força Muscular , Músculo Quadríceps/anatomia & histologia , Traumatismos da Medula Espinal/reabilitação , Adulto , Ciclismo/fisiologia , Humanos , Pessoa de Meia-Idade , Tamanho do Órgão , Projetos Piloto , Músculo Quadríceps/fisiopatologia , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/fisiopatologia , Torque
8.
IEEE Trans Haptics ; 16(3): 379-390, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37436850

RESUMO

When using EMG biofeedback to control the grasping force of a myoelectric prosthesis, subjects need to activate their muscles and maintain the myoelectric signal within an appropriate interval. However, their performance decreases for higher forces, because the myoelectric signal is more variable for stronger contractions. Therefore, the present study proposes to implement EMG biofeedback using nonlinear mapping, in which EMG intervals of increasing size are mapped to equal-sized intervals of the prosthesis velocity. To validate this approach, 20 non-disabled subjects performed force-matching tasks using Michelangelo prosthesis with and without EMG biofeedback with linear and nonlinear mapping. Additionally, four transradial amputees performed a functional task in the same feedback and mapping conditions. The success rate in producing desired force was significantly higher with feedback (65.4±15.9%) compared to no feedback (46.2±14.9%) as well as when using nonlinear (62.4±16.8%) versus linear mapping (49.2±17.2%). Overall, in non-disabled subjects, the highest success rate was obtained when EMG biofeedback was combined with nonlinear mapping (72%), and the opposite for linear mapping with no feedback (39.6%). The same trend was registered also in four amputee subjects. Therefore, EMG biofeedback improved prosthesis force control, especially when combined with nonlinear mapping, which showed to be an effective approach to counteract increasing variability of myoelectric signal for stronger contractions.


Assuntos
Amputados , Membros Artificiais , Percepção do Tato , Humanos , Eletromiografia , Biorretroalimentação Psicológica , Desenho de Prótese
9.
Artigo em Inglês | MEDLINE | ID: mdl-37930904

RESUMO

Reliable force control is especially important when using myoelectric upper-limb prostheses as the force defines whether an object will be firmly grasped, damaged, or dropped. It is known from human motor control that the grasping of non-disabled subjects is based on a combination of anticipation and feedback correction. Inspired by this insight, the present study proposes a novel approach to provide artificial sensory feedback to the user of a myoelectric prosthesis using vibrotactile stimulation to facilitate both predictive and corrective processes characteristic of grasping in non-disabled people. Specifically, the level of EMG was conveyed to the subjects while closing the prosthesis (predictive strategy), whereas the actual grasping force was transmitted when the prosthesis closed (corrective strategy). To investigate if this combined EMG and force feedback is indeed an effective method to explicitly close the control loop, 16 non-disabled and 3 transradial amputee subjects performed a set of functional tasks, inspired by the "Box and Block" test, with six target force levels, in three conditions: no feedback, only EMG feedback, and combined feedback. The highest overall performance in non-disabled subjects was obtained with combined feedback (79.6±9.9%), whereas the lowest was achieved with no feedback (53±11.5%). The combined feedback, however, increased the task completion time compared to the other two conditions. A similar trend was obtained also in three amputee subjects. The results, therefore, indicate that the feedback inspired by human motor control is indeed an effective approach to improve prosthesis grasping in realistic conditions when other sources of feedback (vision and audition) are not blocked.


Assuntos
Membros Artificiais , Humanos , Desenho de Prótese , Retroalimentação Sensorial/fisiologia , Força da Mão/fisiologia , Eletromiografia/métodos , Ácido Dioctil Sulfossuccínico , Mãos
10.
Dis Colon Rectum ; 53(4): 467-74, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20305448

RESUMO

PURPOSE: Stoma creation frequently presents complications for which there is no satisfactory surgical solution. We reexamined the feasibility of managing stoma continence with an artificial sphincter, addressing the outstanding issues of geometry, electrode disposition, and fatigue resistance. METHODS: In 6 pigs, 1 rectus abdominis muscle was preconditioned with electric stimulation for 4 weeks by an implanted stimulator. A sphincter was then constructed and tested for its ability to provide continence against saline at a typical intestinal pressure. The result was compared with a sphincter fashioned from the unconditioned contralateral (control) muscle. In each case, stimulation was applied alternately to longitudinal segments. RESULTS: A 2-layered wrap was required to achieve continence. Sphincters created from the preconditioned muscles could sustain continence continuously for at least 90 minutes. CONCLUSION: This study establishes a practical approach to the creation of a sphincter from the rectus abdominis muscle in stoma patients. Continence can be achieved only with a double-layered wrap. Fatigue during long-term operation can be avoided by a combination of preconditioning and segmental stimulation of intramuscular nerve branches.


Assuntos
Ileostomia/métodos , Reto do Abdome/cirurgia , Animais , Estimulação Elétrica , Eletrodos Implantados , Modelos Animais , Fadiga Muscular , Reto do Abdome/fisiologia , Suínos
11.
Disabil Rehabil Assist Technol ; 15(1): 37-44, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30394146

RESUMO

Aim: Functional electrical stimulation (FES) is a technology that can be used on paralyzed muscles to allow them to move. It has been used in populations with muscle paralysis or weakness for exercise, such as spinal cord injury (SCI) and multiple sclerosis. In order to improve technology, it is vital to understand from a qualitative perspective, issues surrounding device development and implementation.Materials and Methods: In 2016, a study was conducted at the Medical University of Vienna that sought to unravel perspectives of FES exercise from the perspective of clinicians, engineers and researchers. Semi-structured, qualitative interviews were conducted on a sample of participants from the conference (n = 22). Interviews were transcribed verbatim, and text data were analysed.Results: Following this analysis, a conceptual model of FES application in the home environment was derived. We show that the likelihood of continuing FES over time may be influenced by expectations and initial education, as perceived by stakeholders.Conclusion: This model provides a tool by which researchers or clinicians may implement FES in the home environment and may assist in the increased uptake of FES exercise at home for people who may reap benefits from its use.Implications for RehabilitationFunctional electrical stimulation (FES) is a technology that enables individuals with paralysis, such as Spinal Cord Injury or Multiple Sclerosis, to exercise.Motivation and support networks, along with adequate initial education, are essential should patients be able to successfully use FES for exercise.There are unique issues associated with performing FES in the home, and compliance may be influenced by how patients perceive FES with regard to providing benefits, and what their initial expectations are.Communication and education are essential for all parties involved in the provision of FES treatment, to ensure successful treatment with FES at home.


Assuntos
Terapia por Estimulação Elétrica , Terapia por Exercício/instrumentação , Esclerose Múltipla/reabilitação , Traumatismos da Medula Espinal/reabilitação , Participação dos Interessados , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
IEEE Int Conf Rehabil Robot ; 2019: 477-482, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31374675

RESUMO

The increasing number of strokes coincides with the need for new effective rehabilitation systems. In this contribution the methods and results of a series of user surveys comprising methods of qualitative research are presented. The goal of these surveys was to elicit requirements health care professionals pose on rehabilitation devices for upper limb training to enable an effective, efficient and satisfying use in a rehabilitation environment. In a two-step process, two different methods - semi-structured interviews and online questionnaire - were combined to collect data from two independent populations. The analysis of the survey showed that the use of a rehabilitation device should be time-effective and bring joy and that the device should be customizable and provide feedback.


Assuntos
Terapia por Exercício/instrumentação , Inquéritos e Questionários , Extremidade Superior , Feminino , Humanos , Masculino
13.
IEEE Int Conf Rehabil Robot ; 2019: 938-943, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31374750

RESUMO

For patients with lower limb paralysis, wearable robotic systems are becoming increasingly important for regaining mobility. The actuation of these systems is challenging because of the necessity to deliver high power within very limited space. However, not all patients need full support, as many patients have residual muscle function that can be applied for locomotion. This work introduces a microprocessor-controlled leg (hip-knee-ankle-foot) orthosis (mpLeg) with energy recuperation capabilities at the hip joint. The system redistributes motion energy generated by the patient during walking. In stance phase of walking, energy is stored in an elastic element at the hip joint. This energy can be released by computer control later in the gait phase, to support swing phase motion. This work aims at investigating the influence of the elastic element in the orthotic hip joint on a patient's motion. Experiments conducted with a patient suffering from incomplete paraplegia demonstrated that the motion pattern during walking improved with activated energy recuperation. This observation was made over a wide range of system parameters. The patient used the energy recuperation capabilities of the mpLeg with up to 4.1 J recuperated energy per step, which resulted in a more natural swing phase motion during walking. Therefore energy recuperation at the hip joint is a feasible technology for future supportive devices.


Assuntos
Articulação do Quadril/fisiopatologia , Aparelhos Ortopédicos , Paraplegia/fisiopatologia , Caminhada/fisiologia , Feminino , Humanos , Joelho/fisiopatologia , Pessoa de Meia-Idade , Torque
14.
Front Neurosci ; 13: 1442, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32116485

RESUMO

Introduction: Man-machine interfacing remains the main challenge for accurate and reliable control of bionic prostheses. Implantable electrodes in nerves and muscles may overcome some of the limitations by significantly increasing the interface's reliability and bandwidth. Before human application, experimental preclinical testing is essential to assess chronic in-vivo biocompatibility and functionality. Here, we analyze available animal models, their costs and ethical challenges in special regards to simulating a potentially life-long application in a short period of time and in non-biped animals. Methods: We performed a literature analysis following the PRISMA guidelines including all animal models used to record neural or muscular activity via implantable electrodes, evaluating animal models, group size, duration, origin of publication as well as type of interface. Furthermore, behavioral, ethical, and economic considerations of these models were analyzed. Additionally, we discuss experience and surgical approaches with rat, sheep, and primate models and an approach for international standardized testing. Results: Overall, 343 studies matched the search terms, dominantly originating from the US (55%) and Europe (34%), using mainly small animal models (rat: 40%). Electrode placement was dominantly neural (77%) compared to muscular (23%). Large animal models had a mean duration of 135 ± 87.2 days, with a mean of 5.3 ± 3.4 animals per trial. Small animal models had a mean duration of 85 ± 11.2 days, with a mean of 12.4 ± 1.7 animals. Discussion: Only 37% animal models were by definition chronic tests (>3 months) and thus potentially provide information on long-term performance. Costs for large animals were up to 45 times higher than small animals. However, costs are relatively small compared to complication costs in human long-term applications. Overall, we believe a combination of small animals for preliminary primary electrode testing and large animals to investigate long-term biocompatibility, impedance, and tissue regeneration parameters provides sufficient data to ensure long-term human applications.

15.
IEEE Trans Biomed Eng ; 66(12): 3290-3300, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31180833

RESUMO

OBJECTIVE: To develop and evaluate a hybrid robotic system for arm recovery after stroke, combining ElectroMyoGraphic (EMG)-triggered functional electrical stimulation (FES) with a passive exoskeleton for upper limb suspension. METHODS: The system was used in a structured exercise program resembling activities of daily life. Exercises execution was continuously controlled using angle sensor data and radio-frequency identification technology. The training program consisted of 27 sessions lasting 30 min each. Seven post-acute stroke patients were recruited from two clinical sites. The efficacy of the system was evaluated in terms of action research arm test, motricity index, motor activity log, and box & blocks tests. Furthermore, kinematics-based and EMG-based outcome measures were derived directly from data collected during training sessions. RESULTS: All patients showed an improvement of motor functions at the end of the training program. After training, the exercises were in most cases executed faster, smoother, and with an increased range of motion. Subjects were able to trigger FES, but in some cases, they did not maintain the voluntary effort during task execution. All subjects but one considered the system usable. CONCLUSION: The preliminary results showed that the system can be used in a clinical environment with positive effects on arm functional recovery. However, only the final results of the currently ongoing clinical trial will unveil the system's full potential. SIGNIFICANCE: The presented hybrid robotic system is highly customizable, allows to monitor the daily performance, requires low supervision of the therapist, and might have the potential to enhance arm recovery after stroke.


Assuntos
Terapia por Estimulação Elétrica , Exoesqueleto Energizado , Reabilitação do Acidente Vascular Cerebral , Extremidade Superior/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Eletromiografia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/fisiopatologia , Reabilitação do Acidente Vascular Cerebral/instrumentação , Reabilitação do Acidente Vascular Cerebral/métodos , Análise e Desempenho de Tarefas , Adulto Jovem
16.
Circulation ; 114(1 Suppl): I10-5, 2006 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-16820556

RESUMO

BACKGROUND: The intra-aortic balloon pump (IABP) is the device that is in most common use to provide cardiovascular support. A skeletal muscle ventricle (SMV) was configured to produce counterpulsation in the thoracic aorta similar to that obtained with an IABP. The hemodynamic effects of an IABP and a SMV in the same animal and in both normal and failing circulations were assessed. METHODS AND RESULTS: SMVs were connected to and IABPs were placed in the thoracic aorta of 12 anesthetized pigs. Hemodynamic parameters during the IABP- or the SMV-assisted beat were compared with those during the preassist beat. Acute heart failure was induced in 6 of the pigs by snaring the left anterior descending coronary artery (LAD). The hemodynamic effects of the IABP and the SMV were then reassessed. In the assisted cycles, SMV activation increased the mean aortic diastolic pressure (MADP) by 26.5+/-3.5%, the mean diastolic LAD flow by 48.4+/-7.2%, and endocardial viability ratio (EVR) by 31.6+/-3.8% (P<0.0001). In the same animals, IABP assist increased MADP by 19.8+/-2.3%, mean diastolic LAD flow by 37.2+/-3.9%, and EVR by 21.4+/-3.0% (P<0.0001). Under acute heart failure conditions, both SMV and IABP assist significantly increased MADP, mean diastolic LAD flow, and EVR. CONCLUSIONS: In both the normal and failing circulations, the SMV was an effective counterpulsator, providing cardiac assist that was at least equal to that available from an IABP. The SMV may therefore provide the proven benefits of an IABP in ambulant patients.


Assuntos
Contrapulsação/métodos , Insuficiência Cardíaca/cirurgia , Balão Intra-Aórtico , Músculo Esquelético/cirurgia , Animais , Aorta Torácica , Diástole , Modelos Animais de Doenças , Estimulação Elétrica , Eletrodos Implantados , Endocárdio/patologia , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Contração Muscular , Músculo Esquelético/inervação , Infarto do Miocárdio/complicações , Volume Sistólico , Retalhos Cirúrgicos , Sus scrofa
17.
Med Biol Eng Comput ; 45(7): 695-9, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17541669

RESUMO

We describe an implantable stimulator with adjustable output amplitude and bi-directional communication at a size of approximately 1 cm(3). The user selects from preset patterns of stimulation and adjusts the stimulation amplitude by sending coded flashes of light, and receives active confirmation of the chosen settings via a powerful LED in the device. These characteristics allow selectivity of motor nerve stimulation and minimize unwanted excitation of adjacent structures. For example, stimulation of dorsiflexors can be achieved in mice without stimulation of plantarflexors. The device can deliver constant frequency stimulation as well as burst-like stimulation patterns with adjustable ON/OFF times. A lifetime of at least 4 weeks of stimulation at an average frequency of 40 Hz can be achieved. The device was built from standard surface mount components and encapsulated with biocompatible silicone rubber. The use of modern microelectronics allowed us to develop a versatile and highly customizable miniature stimulator.


Assuntos
Estimulação Elétrica/instrumentação , Animais , Eletrônica , Desenho de Equipamento , Camundongos , Microcomputadores , Neurônios Motores/fisiologia , Software
18.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 410-413, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29059897

RESUMO

As motion artefacts are a major problem with electromyography sensors, a new algorithm is developed to differentiate artefacts to contraction EMG. The performance of myoelectric prosthesis is increased with this algorithm. The implementation is done for an ultra-low-power microcontroller with limited calculation resources and memory. Short Time Fourier Transformation is used to enable real-time application. The sum of the differences (SOD) of the currently measured EMG to a reference contraction EMG is calculated. The SOD is a new parameter introduced for EMG classification. The satisfactory error rates are determined by measurements done with the capacitively coupling EMG prototype, recently developed by the research group.


Assuntos
Eletromiografia , Algoritmos , Artefatos , Movimento (Física)
19.
IEEE Int Conf Rehabil Robot ; 2017: 1246-1253, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28813992

RESUMO

Active prosthetic knees have the capability to provide net positive work, which is required in daily activities like stair and ramp negotiation or sit-to-stand transfers. Adding this capability might help to increase user mobility, safety, and independence. This article summarizes the biomechanical knee requirements for different activities of daily living and critically compares them with the actuator characteristics of state-of-the-art active prosthetic knee joints. As a result of a systematic literature research 22 active prosthetic knee joints were identified. Most systems use a stiff actuator in combination with a ball screw and are capable of supporting the majority of daily tasks for the average US citizen (82.5 kg) at self-selected movement speed. Physiological requirements exceed most system specifications if increased user mass, walking speed, or inclinations are assumed. To cope with the requirements, springs and dampers are used to assist the motor. The comparison of the prostheses characteristics with anthropometric data shows that most of the devices are in the physiological range for the system height and even when being tethered it is critical to achieve a physiological mass. Also while just one active knee is commercialized so far, physiological knee biomechanics show that there is a potential for active prosthetic knee solutions. Summarized biomechanical and anthropometric data can be used as a framework to develop prototypes. Further, the overview of state-of-the-art systems can provide possible solutions to deal with the task specific prosthetic knee requirements.


Assuntos
Fenômenos Biomecânicos/fisiologia , Articulação do Joelho/fisiologia , Prótese do Joelho , Desenho de Prótese/métodos , Atividades Cotidianas , Adulto , Amputados/reabilitação , Feminino , Humanos , Masculino , Modelos Biológicos , Adulto Jovem
20.
Front Neurosci ; 11: 421, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28769755

RESUMO

Modern robotic hands/upper limbs may replace multiple degrees of freedom of extremity function. However, their intuitive use requires a high number of control signals, which current man-machine interfaces do not provide. Here, we discuss a broadband control interface that combines targeted muscle reinnervation, implantable multichannel electromyographic sensors, and advanced decoding to address the increasing capabilities of modern robotic limbs. With targeted muscle reinnervation, nerves that have lost their targets due to an amputation are surgically transferred to residual stump muscles to increase the number of intuitive prosthetic control signals. This surgery re-establishes a nerve-muscle connection that is used for sensing nerve activity with myoelectric interfaces. Moreover, the nerve transfer determines neurophysiological effects, such as muscular hyper-reinnervation and cortical reafferentation that can be exploited by the myoelectric interface. Modern implantable multichannel EMG sensors provide signals from which it is possible to disentangle the behavior of single motor neurons. Recent studies have shown that the neural drive to muscles can be decoded from these signals and thereby the user's intention can be reliably estimated. By combining these concepts in chronic implants and embedded electronics, we believe that it is in principle possible to establish a broadband man-machine interface, with specific applications in prosthesis control. This perspective illustrates this concept, based on combining advanced surgical techniques with recording hardware and processing algorithms. Here we describe the scientific evidence for this concept, current state of investigations, challenges, and alternative approaches to improve current prosthetic interfaces.