Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 539, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38720276

RESUMO

BACKGROUND: This study aimed to demonstrate the efficacy of erbium, chromium-doped:yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser-assisted nonsurgical periodontal therapy in periodontitis patients during 8 weeks of healing. METHODS: A split-mouth, single-blinded, randomized controlled clinical trial was conducted on 12 patients diagnosed with stage III/IV periodontitis and had a minimum of two teeth with probing pocket depth (PPD) > 5 mm in at least two quadrants. Upon randomization, each quadrant was assigned for conventional scaling and root planing (SRP) procedure or laser-assisted therapy (SRP + laser) using radial firing tip (RFPT 5, Biolase). Clinical measurements and gingival crevicular fluid collection were performed for statistical analysis. RESULTS: In the initial statistical analysis on the whole subject teeth, modified gingival index (MGI) reduction was greater in test group at 1(P = 0.0153), 4 (P = 0.0318), and 8 weeks (P = 0.0047) compared to the control in the same period. PPD reduction at 4 weeks in test group was -1.67 ± 0.59 showing significant difference compared to the control (-1.37 ± 0.63, P = 0.0253). When teeth with mean PPD ≥5 mm were sorted, MGI decrease was significantly greater in test group at 1 (P=0.003) and 8 week (P=0.0102) follow-ups. PPD reduction was also significantly greater in test group at 4 week period (-1.98 ± 0.55 vs -1.58 ± 0.56, test vs control, P=0.0224). CONCLUSIONS: Er,Cr:YSGG-assisted periodontal therapy is beneficial in MGI and PPD reductions during early healing period.


Assuntos
Raspagem Dentária , Líquido do Sulco Gengival , Lasers de Estado Sólido , Índice Periodontal , Bolsa Periodontal , Aplainamento Radicular , Humanos , Método Simples-Cego , Feminino , Masculino , Lasers de Estado Sólido/uso terapêutico , Adulto , Raspagem Dentária/métodos , Líquido do Sulco Gengival/química , Pessoa de Meia-Idade , Aplainamento Radicular/métodos , Bolsa Periodontal/terapia , Cicatrização , Resultado do Tratamento , Seguimentos , Cromo/uso terapêutico , Periodontite/terapia , Gálio/uso terapêutico
2.
Oral Dis ; 28 Suppl 2: 2522-2529, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33660304

RESUMO

OBJECTIVE: To investigate the role of periodontitis in the risk of acute and chronic coronary syndrome with compounding factors, including sociodemographic factors and medication use. METHODS: This retrospective cohort study used nationwide, population-based data from the Korean National Health Insurance Service-Health Screening Cohort database (514,866 individuals, 40-79 years). Propensity score matching was used for analysis. Information of subjects for 12 years was included. Socioeconomic and clinical factors were recorded and analysed. RESULTS: The periodontitis group had a greater risk of overall acute coronary syndrome (hazard ratio [95% confidence interval] =1.25 [1.15, 1.35], p < .001) and non-fatal acute coronary syndrome (1.26 [1.16, 1.37], p < .001). The hazard ratio for chronic coronary syndrome was higher in patients with periodontitis (1.35 [1.25, 1.46], p < .001). The cumulative incidence of both acute and chronic coronary syndrome gradually increased, and the hazard ratios reached 1.25 and 1.35 at the 12-year follow-up, respectively. Subgroup analysis revealed that periodontitis had a significantly greater link with acute coronary syndrome incidence in males, younger adults, smokers and subjects without hypertension (p < .01) and with chronic coronary syndrome incidence in smokers, subjects without hypertension and subjects without dyslipidaemia (p < .05). CONCLUSIONS: Periodontitis is associated with an increased risk of acute and chronic coronary syndrome.


Assuntos
Síndrome Coronariana Aguda , Hipertensão , Periodontite , Adulto , Masculino , Humanos , Estudos de Coortes , Estudos Retrospectivos , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/epidemiologia , Periodontite/complicações , Periodontite/epidemiologia , Incidência , Hipertensão/complicações , Hipertensão/epidemiologia , Fatores de Risco , Taiwan/epidemiologia
3.
J Prosthet Dent ; 128(4): 764.e1-764.e7, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36309470

RESUMO

STATEMENT OF PROBLEM: Microleakage and loss of the composite resin sealing the screw-access channel are frequent complications of screw-retained implant-supported prostheses. How the screw-access channel should be best restored to reduce such complications is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the microleakage and bond strength of 3 types of composite resins (flowable, packable, and bulk-fill) with or without a bonding agent treatment to seal the screw-access channel of 2 types of restorative materials (zirconia and Co-Cr alloy) with or without thermocycling. MATERIAL AND METHODS: In total, 240 yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) specimens (IPS e.max ZirCAD) and 240 Co-Cr alloy (Vera PDS) specimens were prepared with a Ø3×3-mm cylindrical cavity at the center to simulate the screw-access channel. Three types of composite resins (flowable, packable, and bulk-fill resin) (Filtek Z350 XT Flowable Restorative, Filtek Z350 XT Universal Restorative, and Filtek One Bulk Fill Restorative) were applied to restore the access channel of the zirconia and Co-Cr specimens with or without a bonding agent (Single Bond Universal Adhesive). Microleakage and push-out bond strength were determined and compared by dividing the specimens into experimental groups with or without thermocycling (1000 times with 30 seconds at 5 ±2 °C and 55 ±2 °C). The results were analyzed by using a 1-way ANOVA and 4-way ANOVA. Adjustment for multiple comparisons was made with the Tukey Honestly Significant Difference (HSD) test. RESULTS: The specimens subjected to thermocycling showed a lower bond strength (P<.001) and higher microleakage (P<.001) than specimens stored in a constant-temperature water bath. Specimens treated with bonding agents showed a higher bond strength (P<.001) and lower microleakage (P<.001) than specimens not treated with a bonding agent. Higher bond strengths were observed in the order of bulk-fill resin, packable resin, and flowable resin (P<.001). Packable resin showed higher microleakage than flowable resin and bulk-fill resin (P<.05). No significant difference in microleakage was found between the flowable resin and bulk-fill resin (P>.05). CONCLUSIONS: Higher bond strengths were observed in the order of bulk-fill resin, packable resin, and flowable resin. Less microleakage was observed in the flowable resin and bulk-fill resin than in the packable composite resin. Bonding agent treatment was effective in increasing bond strength and decreasing microleakage. Zirconia and Co-Cr showed a bond strength similar to that of composite resins, but zirconia showed higher microleakage than Co-Cr. Restoring the screw-access channel with the bulk-fill resin should increase bond strength and reduce microleakage.


Assuntos
Implantes Dentários , Infiltração Dentária , Humanos , Restauração Dentária Permanente/métodos , Resinas Compostas/química , Parafusos Ósseos , Ligas , Teste de Materiais
4.
Medicina (Kaunas) ; 58(11)2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36363526

RESUMO

Background and Objectives: To evaluate the stability of a dental implant and the effectiveness of a newly designed damping capacity assessment device by improving the number of blows and strength evaluated by a prospective clinical study. Materials and Method: The stability of dental implants was measured in 50 implants in a total of 38 patients. Measurements were performed using Anycheck and Periotest M devices, twice in total, divided into buccal and lingual directions. In addition, measurements were performed on the day of surgery, two weeks, one month, two months, and three months after surgery for a total of five times. After the standardization of the measured values, the differences and changes over time for each device were observed. Result: No difference in standardized values between the two devices was observed at any time point. In both devices, stability decreased at two weeks postoperatively but gradually increased thereafter. No differences were observed in the values according to the measurement direction. Conclusions: The damping capacity of Anycheck was similar to that of Periotest M. After a slight decrease in stability two weeks after implant placement, implant stability increased over time.


Assuntos
Implantes Dentários , Humanos , Estudos Prospectivos , Cicatrização
5.
J Clin Periodontol ; 48(8): 1066-1075, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34101218

RESUMO

AIM: This study aimed to investigate the association between work patterns and periodontal disease. MATERIALS AND METHODS: Data were collected from the Korea National Health and Nutrition Examination Survey between 2007 and 2012, and data from 22,508 subjects aged ≥19 years were included. An individual's work pattern was classified as either daytime or shift work. Sleep duration was categorized into three ranges: ≤5, 6-8, and ≥9 h/day. A multivariate logistic regression model was used to determine the adjusted odds ratio (OR) for CPI (Community Periodontal Index) ≥3. The CONTRAST statement was used to show the interaction effect of work patterns and sleep duration. RESULTS: The adjusted OR of shift work was 2.168 (CI: 1.929-2.438, p < .0001). Participants who sleep ≤5 or ≥9 h/day showed ORs 0.735 and 0.663, respectively (p = .0181). Interaction effect analysis revealed that the work pattern had a strong influence on periodontal condition when combined with the sleep amount. Shift workers with ≤5 or ≥ 9 h of sleep showed significantly increased ORs for CPI ≥3 (2.1406 and 2.3251, respectively, p < .0001). The ORs for daytime workers were comparable to the original values (≤5: 0.7348, p = .0292; ≥9: 0.6633, p = .0428). CONCLUSION: Altered sleep patterns caused by shift work have more influence on periodontal disease than sleep duration.


Assuntos
Doenças Periodontais , Transtornos do Sono do Ritmo Circadiano , Humanos , Inquéritos Nutricionais , Doenças Periodontais/complicações , Doenças Periodontais/epidemiologia , Sono , Tolerância ao Trabalho Programado
6.
Medicina (Kaunas) ; 57(6)2021 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-34067350

RESUMO

Background andObjectives: Human bone marrow-derived mesenchymal stem cells (BMSCs) are promising sources for cell-based regenerative therapy. The purpose of the present study was to elucidate the roles of age and sex on the cellular viability and osteogenic potential of BMSCs cultured in osteogenic media. Materials and Methods: Human BMSCs were isolated and expanded from 3 age groups-20s, 30s, and 50s-from both sexes. The total number of aspirates was ten, and each subgroup had five for 20s (two females and three males), three for 30s (one female and two male), and two for 50s (one female and one male). Analyses of the cell morphology, the cell viability, the expression of the stem cell marker SSEA-4, the secretion of human vascular endothelial growth factor (VEGF), the expression of Runx2 and collagen I, the metabolic activity, and the formation of mineralization nodules were performed. Results: No significant differences were found in the cell viability of human BMSCs cultured in osteogenic media among the different age groups. There were no significant differences in the expression of SSEA among the age groups or between males and females. There were no significant differences in the secretion of human VEGF between males and females. No significant differences in Runx2 or collagen I expression were noted by age or gender. Moreover, no significant differences were shown in osteogenesis by alizarin red staining. Conclusions: The human BMSCs showed no age-related decreases in cellular viability or osteogenic differentiation potential.


Assuntos
Células-Tronco Mesenquimais , Osteogênese , Medula Óssea , Células da Medula Óssea , Diferenciação Celular , Células Cultivadas , Feminino , Humanos , Masculino , Fator A de Crescimento do Endotélio Vascular
7.
J Prosthet Dent ; 124(4): 468-475, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31810611

RESUMO

STATEMENT OF PROBLEM: Printing orientation is an important decision in the initial steps of additive manufacturing, affecting printing accuracy and the mechanical properties of printed products. In addition, printing orientation determines the building direction of layers and the layer-by-layer configuration forming the surface geometry. PURPOSE: The purpose of this in vitro study was to evaluate the effect of printing orientation on the printing accuracy, flexural strength, surface characteristics, and microbial response of 3D-printed denture base resin. MATERIAL AND METHODS: Specimens were printed with denture base polymethyl methacrylate (PMMA) in 3 printing orientations (0, 45, and 90 degrees). The printing error rate, flexural strength, roughness, hydrophilicity, surface energy, and response to Candida albicans (C. albicans) were evaluated. RESULTS: Specimens printed at a 90-degree orientation showed the lowest error rates for length (P<.001), and those printed at a 45-degree orientation showed statistically higher error rates for thickness than those of other groups (P<.001). Flexural strength increased in order of the specimens printed at orientation degrees of 90<45<0 with statistical significance. The 45-degree oriented specimens showed higher roughness and surface energy than those of other groups (P<.001). A higher proportion of C. albicans was found in the specimens printed at orientation degrees of 90<45<0 with statistical significance. CONCLUSIONS: Printing orientation significantly influenced the printing accuracy, flexural strength, roughness, and response to C. albicans. Therefore, the printing orientation should be carefully decided to fabricate products with appropriate properties.


Assuntos
Materiais Dentários , Polimetil Metacrilato , Bases de Dentadura , Resistência à Flexão , Teste de Materiais , Impressão Tridimensional , Propriedades de Superfície
8.
Aesthetic Plast Surg ; 41(4): 930-937, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28364182

RESUMO

BACKGROUND: A slender or slim face with narrow facial features is considered esthetically appealing in Asian people. Plastic surgery to obtain an oval face, called a 'V-line,' is popular among young people. MATERIALS AND METHODS: A total of 20 Korean patients were included in this study. The patients underwent mandibular anguloplasty with three-dimensional computer-aided design and manufacturing surgical guides that were accurately fitted to the upper and lower teeth, allowing for precise replication of a virtual surgery during a real surgical procedure. RESULTS: There were no significant complications, including severe bleeding, facial nerve injury, or airway obstruction. All patients were satisfied with the esthetic and functional results, except for one who was neutral toward the result. The mean satisfaction score was 4.75, which was between 'satisfied' and 'very satisfied.' CONCLUSION: The V-line guide and gooseneck saw allowed for safe and fast resection of bone in the mandibular angle area. This technique provides consistent results during surgery as well as minimizing surgical complications. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors http://www.springer.com/00266 .


Assuntos
Imageamento Tridimensional , Osteotomia Mandibular/métodos , Cirurgia Plástica/métodos , Adulto , Povo Asiático , Estudos de Coortes , Desenho Assistido por Computador , Estética , Feminino , Seguimentos , Humanos , Masculino , Segurança do Paciente , Procedimentos de Cirurgia Plástica/métodos , República da Coreia , Estudos Retrospectivos , Medição de Risco , Resultado do Tratamento , Adulto Jovem
9.
J Esthet Restor Dent ; 29(3): 209-214, 2017 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-28258661

RESUMO

OBJECTIVE: The aim of this study was to investigate the polymerization mode of self-adhesive, dual-cured resin cements light-cured through overlying materials with different degree of translucency by measuring the degree of conversion (DC). MATERIALS AND METHODS: Three kinds of self-adhesive, dual-cured resin cements (G-CEM LinkAceTM , Maxcem EliteTM , and BisCem® ) were light-cured through three different restorative materials that included porcelain-fused metal (PFM), zirconia, and lithium disilicate. Polymerization kinetics were continuously evaluated using infrared spectroscopy after 0, 5, 10, and 30 min and 2 weeks of mixing. Data were statistically analyzed using two-way analysis of variance (ANOVA), one-way ANOVA, and Tukey's multiple-comparison test (α = 0.05). RESULTS: Regardless of the kind of resin cement, the light-cured groups showed higher DC than did the autopolymerization group under PFM at any point of time (p < 0.05). The time taken by the cements to achieve statistically similar DC between the zirconia and lithium disilicate groups increased in the following order: G-CEM LinkAceTM , BisCem® , and Maxcem EliteTM (p < 0.05). CONCLUSIONS: The degree of translucency of the restorative material can be a significant variable determining the polymerization aspects of self-adhesive, dual-cured resin cements. The resin cements light-cured through lithium disilicate and zirconia showed higher DC than that shown by cements cured under PFM at any measurement time. The lithium disilicate and zirconia groups showed differences in the early stage of polymerization for G-CEM LinkAceTM and BisCem® ; however, the differences diminished at 2 weeks. CLINICAL SIGNIFICANCE: Chemical polymerization is not sufficient to cause the resin cement to achieve the highest polymerization not only in early stage, but also in late stage of polymerization. The sensitivity to the intensity of the light was different for each resin cement. Special clinical steps to compensate for the attenuated light intensity seem to be necessary for the resin cements which are susceptible to light intensity. (J Esthet Restor Dent 29:209-214, 2017).


Assuntos
Cura Luminosa de Adesivos Dentários , Cimentos de Resina/química , Resinas Compostas , Porcelana Dentária/química , Teste de Materiais , Polimerização , Zircônio/química
10.
Implant Dent ; 24(6): 726-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26384100

RESUMO

PURPOSE: To analyze the accuracy of impressions in relation to implant angulation and type of impression coping. MATERIALS AND METHODS: Three metal master models with 2 implants of 3 different angulations (parallel, mesiodistal, and buccolingual) were fabricated. Nine groups of experimental models were fabricated to duplicate the 3 master models using 3 types of impression copings: transfer, pick-up, and hybrid. The distance between the analogs for each model was measured using a video measuring system. The influence of angulation and type of impression coping was analyzed by a two-way ANOVA (P < 0.05). RESULTS: There were significant differences in error rates in relation to implant angulation and type of impression coping (P < 0.05). Impressions of buccolingually divergent implants with transfer copings showed statistically higher error rates than other groups (P < 0.05). CONCLUSIONS: Buccolingual divergence can be a variable that influences the impression accuracy of transfer copings compared with pick-up and hybrid copings. Hybrid copings demonstrate reasonable reproducibility similar to that of pick-up copings.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Projeto do Implante Dentário-Pivô/métodos , Planejamento de Prótese Dentária , Humanos
11.
Odontology ; 102(2): 241-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23665890

RESUMO

Understanding of the interaction between human MG63 osteoblast-like cells and surfaces is necessary in the field of tissue engineering and biomaterials. Various titanium surfaces are widely used as not only implant materials, but also as miniscrews in orthodontics. Our goal was to assess the proteomic response of MG63 osteoblast-like cells to different titanium surfaces. MG63 osteoblast-like cells were cultured on three different titanium surfaces: a smooth surface (S), a sandblasted with large grit and acid-etched surface (SLA), and a surface coated with a thin layer of hydroxyapatite (HA). Cells grown on the rougher surfaces (SLA and HA) exhibited downregulated cell proliferation and morphological changes. In the proteomic analysis, cells grown on the SLA surface showed upregulated expression of protocadherin-ß3 precursor, kinase insert domain receptor, fibroblast growth factor receptor-3, and insulin-like growth factor I, while the expression levels of cell adhesion kinase, collagen α-1(I) chain precursor, collagen type XI α2, and cadherin-11 were upregulated in cells grown on the HA surface. These proteins are known to be involved in osteoblast adhesion, growth, and differentiation. Thus, the surface properties of dental materials can influence the expression of proteins involved in osseointegration-related processes. Proteomic analysis may reveal changes in novel proteins that explain why osseointegration varies depending on surface properties.


Assuntos
Osteoblastos/citologia , Proteômica , Linhagem Celular , Cristalografia por Raios X , Humanos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
12.
Materials (Basel) ; 17(2)2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38255564

RESUMO

To manufacture dental restorations composed of lithium disilicate (LD) through the computer-aided design and manufacturing (CAD/CAM) process, thermal refinement is an essential process that can affect the optical and mechanical properties of ceramics. In this study, we aimed to evaluate the translucency and flexural strength of lithium disilicate glass-ceramic for CAD/CAM using different thermal refinement schedules and thicknesses by measuring the total transmission of light through the specimen and calculating the peak load of the specimen until fracture in a piston-on-three-ball test, respectively. The results showed that a lower translucency was exhibited in thicker specimens, and the flexural strength decreased in the order of 1.0, 0.5, and 2.0 mm (p < 0.05). The lithium disilicates thermally refined at a heat of 820 degrees were shown to have the highest biaxial flexural strength (p < 0.05). These findings suggest that it is possible to adjust transparency and strength according to the clinical situation by choosing an appropriate thickness and thermal refinement process.

13.
Implant Dent ; 22(1): 66-70, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23296031

RESUMO

PURPOSE: To compare the fracture load and failure mode of the monolithic lithium disilicate crown (e.max group) and 2 types of veneered zirconia crowns, hand layer (ZV group) and heat pressed (ZP group), as a posterior implant-supported restoration. METHODS: A total of 24 all-ceramic crowns for molar tooth were fabricated using the computer-aided design/computer-assisted manufacture (CAD/CAM) system. The e.max group crowns and zirconia copings for ZV and ZP groups were fabricated using a Cerec milling unit. The ZV group was fabricated using a hand-layer veneering method, and the ZP group using a heat-pressing method. All crowns were luted to the abutments, which were connected to implant fixtures, using resin cement. Fracture load was measured using the universal testing machine, and the fracture surface was evaluated by scanning electron microscopy. RESULTS: The ZP group showed significantly higher fracture load (5229.3 N) compared with the e.max group (3852.1 N) and ZV group (3100.3 N). All fractures in the ZV group occurred in the veneered layer. CONCLUSION: Monolithic CAD/CAM lithium disilicate crowns are applicable to posterior implant-supported restorations because the fracture load was higher than the average occlusal force.


Assuntos
Desenho Assistido por Computador , Coroas , Porcelana Dentária/química , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Facetas Dentárias , Zircônio/química , Cimentação/métodos , Colagem Dentária , Implantes Dentários , Planejamento de Prótese Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Dente Molar , Cimentos de Resina/química , Estresse Mecânico , Propriedades de Superfície
14.
Adv Healthc Mater ; 12(4): e2200527, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36373222

RESUMO

This study hypothesizes that the application of low-dose nonthermal biocompatible dielectric barrier discharge plasma (DBD-NBP) to human gingival fibroblasts (HGFs) will inhibit colony formation but not cell death and induce matrix metalloproteinase (MMP) expression, extracellular matrix (ECM) degradation, and subsequent cell migration, which can result in enhanced wound healing. HGFs treated with plasma for 3 min migrate to each other across the gap faster than those in the control and 5-min treatment groups on days 1 and 3. The plasma-treated HGFs show significantly high expression levels of the cell cycle arrest-related p21 gene and enhanced MMP activity. Focal adhesion kinase (FAK) mediated attenuation of wound healing or actin cytoskeleton rearrangement, and plasma-mediated reversal of this attenuation support the migratory effect of DBD-NBP. Further, this work performs computer simulations to investigate the effect of oxidation on the stability and conformation of the catalytic kinase domain (KD) of FAK. It is found that the oxidation of highly reactive amino acids (AAs) Cys427, Met442, Cys559, Met571, Met617, and Met643 changes the conformation and increases the structural flexibility of the FAK protein and thus modulates its function and activity. Low-dose DBD-NBP-induces host cell cycle arrest, ECM breakdown, and subsequent migration, thus contributing to the enhanced wound healing process.


Assuntos
Gengiva , Cicatrização , Humanos , Proteína-Tirosina Quinases de Adesão Focal/metabolismo , Movimento Celular , Fibroblastos , Células Cultivadas
15.
J Adv Prosthodont ; 15(3): 126-135, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37441716

RESUMO

PURPOSE: The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient. MATERIALS AND METHODS: Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position). A resonance frequency analysis device (Osstell) and two damping capacity analysis devices (Periotest and Anycheck) were used to measure implant stability. The values measured outside the phantom head were treated as controls, and the values inside the phantom head were compared using an independent t-test. RESULTS: Osstell showed different results in two of the six divisions in both the supine and upright positions compared to outside of the mouth (P < .05). Periotest showed different results in all six parts in the supine position and in five parts in the upright position compared to outside of the mouth (P < .05). While Anycheck showed different results in five areas in the supine position compared to outside of the mouth, it showed different results in only one area in the upright position (P < .05). CONCLUSION: In the difficult implant position for the operator to access, the implant stability measuring devices show less reliability. The accessibility of implant is greatly affected in the order of Osstell, Anycheck, and Periotest.

16.
Psychol Rep ; : 332941221133005, 2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36219194

RESUMO

The purpose of this study was to explore variables related to school belonging from a holistic perspective, including a large number of variables in one model, different to the traditional analytical method. Using 2015 data from the Program for International Student Assessment (PISA), we sought to identify variables related to school belonging by searching for hundreds of predictors in one model using the group Mnet machine learning technique. The study repeated 100 rounds of model building after random data splitting. After exploring 504 variables (384 student and 99 parent), 32 variables were finally selected after selection counts. Variables predicting a sense of school belonging were categorized as individual/parent variables (e.g. motivation to achieve, tendency to cooperative learning, parental support) and school-related variables (e.g. school satisfaction, peer/teacher relationship, learning/physical activities). The significance and implications of the study as well as future research topics were discussed.

17.
Macromol Biosci ; 22(10): e2200162, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35895972

RESUMO

Synthetic scaffolds, as bone grafts, provide a favorable environment for the repair and growth of new bone tissue at defect sites. However, the lack of angio- and osteo-induction limits the usefulness of artificial scaffolds for bone regeneration. Nitric oxide (NO) performs essential roles in healing processes, such as regulating inflammation and addressing incomplete revascularization. In this study, a polymer capable of controlled NO release is developed to promote the osteogenic capacity in artificial scaffolds. The biological efficiency of the NO compound is assessed by its effect on pre-osteoblasts and macrophages in vitro and the extent of vascularization and bone formation in the calvaria defect model in vivo. The compound does not inhibit cell adhesion or proliferation. NO treatment significantly increases both alkaline phosphatase activity and mineralization in pre-osteoblasts. Macrophages treated with NO secrete high levels of anti-inflammatory factors and adopt the pro-regenerative phenotype. In the critical-sized defect model, the collagen scaffold containing the NO compound enhances neovascularization and bone formation. The developed NO-releasing system promotes osteogenesis and regeneration of damaged bone tissue. As the multiple functions of NO involve macrophage modulation and angiogenesis, such release systems may be valuable for guiding bone regeneration in critical-sized defects.


Assuntos
Células-Tronco Mesenquimais , Osteogênese , Fosfatase Alcalina/metabolismo , Regeneração Óssea , Diferenciação Celular , Colágeno/metabolismo , Óxido Nítrico/metabolismo , Osteogênese/genética , Polímeros/metabolismo , Polímeros/farmacologia , Alicerces Teciduais
18.
J Dent Sci ; 16(1): 29-36, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33384775

RESUMO

BACKGROUND/PURPOSE: Antimicrobial activity and biocompatibility of root canal sealer are related to the success of endodontic treatments. This study investigated the efficacy of mixture of mineral trioxide aggregate (MTA) and a NO-releasing compound for the antimicrobial activity, biocompatibility, and physical properties. MATERIALS AND METHODS: MTA was mixed with diethylenetriamine-NO (MTA-NO), and the extracts from MTA and the MTA-NO mixture before and after setting was obtained were investigated the antimicrobial activity against Enterococcus faecalis and Porphyromonas endodontalis. After setting MTA and MTA-NO, pulp cell was incubated in the presence of MTA and MTA-NO disk using Transwell® cell culture insert, and the proliferation assay and mineralization-stimulated factors of the cells were analyzed by MTT assay and real-time RT-PCR, respectively. The physical properties of MTA and the MTA-NO mixture, such as surface hardness and flowability was also analyzed. RESULTS: The MTA-NO mixture showed stronger antimicrobial activity against E. faecalis and P. endodontalis than that by MTA. Both MTA and MTA-NO mixture increase the ratio of cell proliferation and induced the expression of alkaline phosphatase, collagen type I, osteocalcin, and osteopontin. Moreover, the induction of gene expression by MTA-NO mixture was higher than that by MTA alone. No significant difference was observed for surface hardness and flowability between MTA and MTA-NO mixture. CONCLUSION: The addition of a NO-releasing compound to the endodontic treatment using MTA root canal sealer might reduce the risk of bacterial infection and help to regenerate the dental pulp tissue.

19.
J Korean Assoc Oral Maxillofac Surg ; 47(3): 233-236, 2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-34187965

RESUMO

A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.

20.
Healthcare (Basel) ; 9(4)2021 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-33917171

RESUMO

The aim of this study was to evaluate the three-dimensional reproducibility of the structured-light facial scanner according to the head position change. A mannequin head was used and angle of the mannequin's axis-orbital plane to the true horizontal plane was adjusted to +10, +5, 0, -5, and -10°. Facial scanning was conducted 30 times, respectively, and 150 3D images were obtained. Reoriented landmarks of each group were compared and analyzed. Reproducibility decreased as the distance from the facial center increased. Additionally, the landmarks below showed lower reproducibility and higher dispersion than landmarks above. These differences occurred mainly in the anteroposterior direction as opposed to other directions. Positive inclination of the head position showed superior reproducibility compared to a negative inclination. This study showed that reproducibility of a structured-light scanner could be varied depending on the head position. Inaccuracies of landmarks in the anteroposterior direction are greater than in other directions. This means that evaluations of the profile using a structured-light scanner should be made carefully. Therefore, the proper head position should be set to ensure the accuracy of the image.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA