RESUMO
The present evidence-based guidelines are focused on the use of device-assisted enteroscopy in the management of small-bowel diseases. A panel of experts selected by the Spanish and Portuguese small-bowel study groups reviewed the available evidence focusing on the main indications of this technique, its role in the management algorithm of each indication, and its diagnostic and therapeutic yield. A set of recommendations was issued accordingly.
Assuntos
Endoscopia por Cápsula , Enteropatias , Humanos , Enteropatias/diagnóstico por imagem , Enteropatias/terapia , Intestino Delgado/diagnóstico por imagem , PortugalRESUMO
In the study of obscure gastrointestinal bleeding, which includes iron-deficiency anemia, the capsule endoscopy is a valuable diagnostic tool. In the different series the presence of tumors reaches 16% as the cause of it. We present the case of a rare tumor with metastatic extension in the small intestine in which the capsule endoscopy was key to the diagnosis and survival of the patient.
Assuntos
Endoscopia por Cápsula , Dermatofibrossarcoma/secundário , Neoplasias Duodenais/secundário , Neoplasias do Jejuno/secundário , Neoplasias Pulmonares/secundário , Neoplasias Cutâneas/patologia , Adulto , Nádegas , Dermatofibrossarcoma/diagnóstico por imagem , Dermatofibrossarcoma/terapia , Neoplasias Duodenais/diagnóstico por imagem , Humanos , Neoplasias do Jejuno/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia ComputadorizadaRESUMO
BACKGROUND AND AIM: The role of capsule endoscopy (CE) in established celiac disease (CD) remains unclear. Our objective was to analyze the usefulness of CE in the suspicion of complicated CD. METHODS: This was a retrospective multicenter study. One hundred and eighty-nine celiac patients (mean age: 46.6 ± 16.6, 30.2% males) who underwent CE for alarm symptoms (n = 86, 45.5%) or non-responsive CD (n = 103, 54.5%) were included. Diagnostic yield (DY), therapeutic impact and safety were analyzed. RESULTS: Capsule endoscopy was completed in 95.2% of patients (small bowel transit time: 270.5 ± 100.2 min). Global DY was 67.2%, detecting atrophic mucosa (n = 92, 48.7%), ulcerative jejunoileitis (n = 21, 11.1%), intestinal lymphoma (n = 7, 3.7%) and other enteropathies (n = 7, 3.7%, six Crohn's disease cases and one neuroendocrine tumor). The DY of CE was significantly higher in patients presenting with non-responsive disease compared to patients with alarm symptoms (73.8% vs 59.3%, P = 0.035). The new findings of the CE modified management in 59.3% of the cases. There were no major complications. CONCLUSION: Capsule endoscopy may be a moderately helpful and safe diagnostic tool in the suspicion of complicated CD, modifying the clinical course of these patients.
Assuntos
Endoscopia por Cápsula/métodos , Doença Celíaca/diagnóstico , Dieta Livre de Glúten , Mucosa Intestinal/patologia , Adulto , Doença Celíaca/dietoterapia , Estudos de Coortes , Progressão da Doença , Feminino , Seguimentos , Humanos , Intestino Delgado/patologia , Intestino Delgado/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Adulto JovemRESUMO
INTRODUCTION: Colon capsule endoscopy (CCE) is an alternative approach for the examination of the colon in patients who refuse colonoscopy or after incomplete colonoscopy (IC). We conducted a study to determine the frequency of complete colonoscopy after IC, the diagnostic yield of CCE, the therapeutic impact of lesions found in CCE, the level of colon cleanliness and the safety of the procedure. METHODS: We performed a prospective, multicenter study involving ten Spanish hospitals. Consecutive outpatients aged ≥ 18 years with previous IC were invited to participate. The latest version of the CCE device, PillCam™ COLON 2 (CCE-2), was administered to all patients according to the protocol. RESULTS: The study population comprised 96 patients. The most frequent cause of IC was the inability to move past a loop using standard maneuvers (75/96 patients, 78%). Complete visualization of the colon was obtained with CCE-2 in 69 patients (71.9%). Of the 27 patients in whom the CCE-2 did not reach the hemorrhoidal plexus, it passed the colonic segment explored with the previous colonoscopy in 20 cases; therefore, it could be inferred that a combined approach (CCE-2 plus colonoscopy) enabled complete visualization of the colonic mucosa in 92.7% of patients. CCE-2 revealed new lesions in 58 patients (60.4%). Polyps were the most frequent finding (41 patients; 42.7% of the total number of patients). In 43 of the 58 patients (44.8% of the total number of patients), the new lesions observed led to modification of therapy, which included a new colonoscopy for polyp resection or surgery in patients with colonic neoplasm. CONCLUSIONS: CCE-2 is a suitable diagnostic procedure that can lead to more frequent diagnosis of significant colonic lesions after IC.
Assuntos
Endoscopia por Cápsula/instrumentação , Colo/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Diverticulose Cólica/diagnóstico por imagem , Mucosa Intestinal/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , EspanhaRESUMO
High resolution esophageal manometry (HRM) is currently under development as can be seen in the various Chicago classifications. In order to standardize criteria in certain practical aspects with limited scientific evidence, the First National Meeting for Consensus in High Resolution Manometry of the Spanish Digestive Motility Group took place, bringing together a wide group of experts. The proposals were based on a prior survey composed of 47 questions, an exhaustive review of the available literature and the experience of the participants. Methodological aspects relating to the poorly defined analysis criteria of certain new high resolution parameters were discussed, as well as other issues previously overlooked such as spontaneous activity or secondary waves. Final conclusions were drawn with practical applications.
Assuntos
Doenças do Esôfago/diagnóstico por imagem , Esôfago/diagnóstico por imagem , Manometria/métodos , Anestesia , Consenso , Motilidade Gastrointestinal , HumanosRESUMO
Background and study aims In 2019, the European Society of Gastrointestinal Endoscopy (ESGE) created a working group to develop technical and quality standards for small-bowel capsule endoscopy (SBCE) to improve the daily practice of endoscopy services. They developed 10 quality parameters, which have yet to be tested in a real-life setting. Our study aimed to evaluate the accomplishment of the quality standards in SBCE established by the ESGE in several Spanish centers. Materials and methods An online survey of 11 multiple-choice questions related to the ESGE performance measures was sent to Spanish centers with experience in SBCE. In order to participate and obtain reliable data, at least 100 questionnaires had to be answered per center because that is the minimum number established by ESGE. Results 20 centers participated in the study, compiling 2049 SBCEs for the analysis. Only one of 10 performance measures (cecal visualization) reached the minimum standard established by the ESGE. In five of 10 performance measures (Indication, lesion detection rate, terminology, and retention rate) the minimum standard was nearly achieved. Conclusions Our study is the first multicenter study regarding SBCE quality performance measures in a real setting. Our results show that the minimum standard is hardly reached in most procedures, which calls into question their clinical applicability in real life. We suggest performing similar studies in other countries to evaluate whether there is a need for quality improvement programs or a need to reevaluate the minimum and target values published so far.
RESUMO
The present evidence-based guidelines are focused on the use of device-assisted enteroscopy in the management of small-bowel diseases. A panel of experts selected by the Spanish and Portuguese small bowel study groups reviewed the available evidence focusing on the main indications of this technique, its role in the management algorithm of each indication and on its diagnostic and therapeutic yields. A set of recommendations were issued accordingly.
Estas recomendações baseadas na evidência detalham o uso da enteroscopia assistida por dispositivo no manejo clínico das doenças do intestino delgado. Um conjunto de Gastrenterologistas diferenciados em patologia do intestino delgado foi selecionado pelos grupos de estudos Espanhol e Portugués de intestino delgado para rever a evidência disponível sobre as principais indicações desta técnica, o seu papel nos algoritmos de manejo de cada indicação e sobre o seu rendimento diagnóstico e terapêutico. Foi gerado um conjunto de recomendações pelos autores.
RESUMO
AIM: To analyze the diagnostic yield (DY), therapeutic impact (TI) and safety of capsule endoscopy (CE). METHODS: This is a multi-centre, observational, analytical, retrospective study. A total of 163 patients with suspicion of celiac disease (CD) (mean age = 46.4 ± 17.3 years, 68.1% women) who underwent CE from 2003 to 2015 were included. Patients were divided into four groups: seronegative CD with atrophy (Group-I, n = 19), seropositive CD without atrophy (Group-II, n = 39), contraindication to gastroscopy (Group-III, n = 6), seronegative CD without atrophy, but with a compatible context (Group-IV, n = 99). DY, TI and the safety of CE were analysed. RESULTS: The overall DY was 54% and the final diagnosis was villous atrophy (n = 65, 39.9%), complicated CD (n = 12, 7.4%) and other enteropathies (n = 11, 6.8%; 8 Crohn's). DY for groups I to IV was 73.7%, 69.2%, 50% and 44.4%, respectively. Atrophy was located in duodenum in 24 cases (36.9%), diffuse in 19 (29.2%), jejunal in 11 (16.9%), and patchy in 10 cases (15.4%). Factors associated with a greater DY were positive serology (68.3% vs 49.2%, P = 0.034) and older age (P = 0.008). On the other hand, neither sex nor clinical presentation, family background, positive histology or HLA status were associated with DY. CE results changed the therapeutic approach in 71.8% of the cases. Atrophy was associated with a greater TI (92.3% vs 45.3%, P < 0.001) and 81.9% of the patients responded to diet. There was one case of capsule retention (0.6%). Agreement between CE findings and subsequent histology was 100% for diagnosing normal/other conditions, 70% for suspected CD and 50% for complicated CD. CONCLUSION: CE has a high DY in cases of suspicion of CD and it leads to changes in the clinical course of the disease. CE is safe procedure with a high degree of concordance with histology and it helps in the differential diagnosis of CD.