Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Malar J ; 19(1): 129, 2020 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-32228615

RESUMO

BACKGROUND: The World Health Organization (WHO) recommends parasite-based diagnosis of malaria. In recent years, there has been surge in the use of various kinds of nucleic-acid amplification based tests (NAATs) for detection and identification of Plasmodium spp. to support clinical care in high-resource settings and clinical and epidemiological research worldwide. However, these tests are not without challenges, including lack (or limited use) of standards and lack of reproducibility, due in part to variation in protocols amongst laboratories. Therefore, there is a need for rigorous quality control, including a robust external quality assessment (EQA) scheme targeted towards malaria NAATs. To this effect, the WHO Global Malaria Programme worked with the UK National External Quality Assessment Scheme (UK NEQAS) Parasitology and with technical experts to launch a global NAAT EQA scheme in January 2017. METHODS: Panels of NAAT EQA specimens containing five major species of human-infecting Plasmodium at various parasite concentrations and negative samples were created in lyophilized blood (LB) and dried blood spot (DBS) formats. Two distributions per year were sent, containing five LB and five DBS specimens. Samples were tested and validated by six expert referee laboratories prior to distribution. Between 37 and 45 laboratories participated in each distribution and submitted results using the online submission portal of UK NEQAS. Participants were scored based on their laboratory's stated capacity to identify Plasmodium species, and individual laboratory reports were sent which included performance comparison with anonymized peers. RESULTS: Analysis of the first three distributions revealed that the factors that most significantly affected performance were sample format (DBS vs LB), species and parasite density, while laboratory location and the reported methodology used (type of nucleic acid extraction, amplification, or DNA vs RNA target) did not significantly affect performance. Referee laboratories performed better than non-referee laboratories. CONCLUSIONS: Globally, malaria NAAT assays now inform a range of clinical, epidemiological and research investigations. EQA schemes offer a way for laboratories to assess and improve their performance, which is critical to safeguarding the reliability of data and diagnoses especially in situations where various NAAT methodologies and protocols are in use.


Assuntos
Testes Diagnósticos de Rotina/estatística & dados numéricos , Malária/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/estatística & dados numéricos , Plasmodium/isolamento & purificação , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Humanos , Controle de Qualidade , Reprodutibilidade dos Testes , Organização Mundial da Saúde
2.
J Clin Pathol ; 64(10): 901-4, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21680573

RESUMO

AIM: To compare the recovery of parasites in faecal samples using the Midi Parasep with ethyl acetate and Midi Parasep Solvent Free (SF) faecal parasite concentrators. METHODS: 23 preserved and 11 fresh faecal samples were microscopically examined for the presence of parasites using the Midi Parasep concentrator with ethyl acetate centrifuged for 1 and 3 min and the Midi Parasep SF concentrator. RESULTS: The Midi Parasep SF faecal parasite system recovered significantly fewer ova and cysts and resulted in a notably larger deposit than the Midi Parasep concentrator with ethyl acetate. CONCLUSIONS: Parasites present in small numbers that would be detected using the Midi Parasep concentrator with ethyl acetate could be missed using the SF faecal parasite system.


Assuntos
Fezes/parasitologia , Contagem de Ovos de Parasitas , Parasitos/isolamento & purificação , Manejo de Espécimes/instrumentação , Acetatos/química , Animais , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes , Solventes/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA