Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Isr Med Assoc J ; 25(5): 324-327, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37245095

RESUMO

BACKGROUND: Cancellation of transesophageal echocardiography (TEE) tests leads to inefficient use of echocardiography laboratory (echo lab) time and wastes resources. OBJECTIVES: To identify the causes of same-day TEE cancellations in hospitalized patients, to formulate a TEE order screening protocol, and to evaluate its efficacy at implementation. METHODS: We performed a prospective analysis of inpatients referred to a single tertiary hospital echo lab for TEE study by inpatient wards. A comprehensive screening protocol emphasizing active participation of all links directly involved in the chain of inpatient TEE referral was developed and implemented. Comparison of pre- and post-implementation of the new screening protocol on two consecutive periods of 6 months on TEE cancellation rates out of total ordered TEEs stratified by cause categories was performed. RESULTS: : In total, 304 inpatient TEE procedures were ordered during the initial observation period; 54(17.8%) were canceled on the same day. The most common cancellation reasons were equally respiratory distress and patient not in fasted state (20.4% of total cancellations and 3.6% of all scheduled TEEs for each cause). Following implementation of the new screening process, total TEEs ordered (192) and cancelled (16) dropped significantly. A decrease in the rate of each cancellation category was observed, with statistical significance achieved for the overall cancellation rate (8.3% vs. 17.8%, P = 0.003), but not for the individual cancellation categories in split analysis. CONCLUSIONS: A concerted effort to implement a comprehensive screening questionnaire significantly reduced same-day cancellations of scheduled TEEs.


Assuntos
Agendamento de Consultas , Pacientes Internados , Humanos , Israel , Centros de Atenção Terciária , Ecocardiografia Transesofagiana , Estudos Retrospectivos
2.
Infection ; 50(1): 57-64, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34089484

RESUMO

PURPOSE: To evaluate the impact of a multidisciplinary the "Endocarditis Team" (ET) on the course and outcome of infective endocarditis (IE) patients. METHODS: A retrospective before-after study, including hospitalized patients with definite IE, managed before (01.2013-12.2015) and after (01.2016-07.2019) the introduction of an ET. The primary outcomes were defined as 30-day and 1-year mortality and the secondary as conservative vs. invasive strategy, the interval from clinical suspicion of IE to the performance of echocardiography, utilization of multimodality evaluation, time to an invasive procedure, and the duration of hospitalization. RESULTS: Study population included 92 pre-ET and 128 post-ET implementation patients. Baseline characteristics were similar. During the post-ET period compared with pre-ET, we found higher rates of abscesses and extra-cardiac emboli (27.8% vs. 16.3%, p = 0.048); and a higher invasive procedures rate, including lead extraction (15.6% vs. 6.5%, p = 0.035) and noncardiac surgeries (14.8% vs. 6.5%, p = 0.05). Patients managed during the post-ET period had reduced short (8.5% vs. 17.4%, p = 0.048) and long-term mortality (Log-rank = 0.001). In multivariate analysis of risk factors for long-term mortality, period (pre- or post-ET) was not found to be significantly associated with the mortality. CONCLUSION: Establishment of an ET was associated with faster and more intensive evaluation of patients with IE. During the period of an ET activity, mortality rates were reduced compared with the previous period.


Assuntos
Endocardite Bacteriana , Endocardite , Endocardite/diagnóstico , Endocardite/epidemiologia , Endocardite/terapia , Mortalidade Hospitalar , Hospitalização , Humanos , Estudos Retrospectivos , Fatores de Risco
3.
Echocardiography ; 38(12): 2016-2024, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34854128

RESUMO

BACKGROUND: In view of inconsistencies in threshold values of severe aortic stenosis (AS) hemodynamic indices, it is unclear what is the relative contribution of each variable in a binary classification of AS based on aortic valve replacement (AVR) indication. We aimed to assess relative discriminative value and optimal threshold of each constituent hemodynamic parameter for this classification and confirm additional prognostic value. METHODS: Echocardiography studies of 168 patients with ≥ moderate AS were included. AS types were dichotomized into Group-A, comprising moderate and Normal-Flow Low-Gradient (NFLG), and Group-B, comprising High-Gradient(HG), Low Ejection Fraction Low-Flow Low-Gradient(Low EF-LFLG), and Paradoxical Low-Flow Low-Gradient(PLFLG) AS. Aortic valve area (AVA), Doppler velocity index (DVI), peak aortic velocity, mean gradient, stroke volume index and transaortic flow rate(TFR) were assessed for A/B Group discrimination value and optimal thresholds were determined. Dichotomized values were assessed for predictive value for AVR or death. RESULTS: C-statistic values for binary AS classification was .74-.9 for the tested variables. AVA and DVI featured the highest score, and SVI the lowest one. AVA≤.81 cm2 and DVI≤.249 had 87.6% and 86% respective sensitivity for Group B patients, and a similar specificity of 80.9%. During a mean follow-up of 9.1±10.1 months, each of the tested dichotomized variables except for SVI predicted AVR or death on multivariate analysis. CONCLUSION: An AVA value ≤.81 cm2 or a DVI ≤ .249 threshold carry the highest discriminative value for severe AS in patients with aortic stenosis, translating into an independent prognostic value, and can be helpful in making clinical decisions.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Humanos , Índice de Gravidade de Doença , Volume Sistólico
4.
Harefuah ; 159(6): 414-422, 2020 Jun.
Artigo em Hebraico | MEDLINE | ID: mdl-32583644

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is used in patients with severe aortic stenosis (AS) who are at high surgical risk. Pre- and post-operative management is challenging as these patients are older, have significant comorbidities and a very high expected mortality rate in conventional surgery. There is no consensus in the literature about the preferred form of anesthesia, however, currently most centers perform the procedure using local anesthesia with sedation (LA-S). OBJECTIVES: To compare general anesthesia (GA) and LA-S in patients undergoing TAVI. METHODS: A retrospective review of the first 100 patients who underwent TAVI (11/2008-6/2011) at the Rabin Medical Center, due to severe and symptomatic AS and a counter-indication for conventional valve replacement surgery. RESULTS: A total of 46 patients underwent the procedure with GA and 54 with LA-S. In 63 patients, the transfemoral approach was used, transapical in 23, and transaxillary in 11. There were no significant differences in short- and long-term mortality, but average hospitalization was longer in the GA group. A larger proportion of patients needed norepinephrine and blood transfusions during the procedure in the GA group. In the LA-S group, more conduction, vascular complications and postoperative fever were observed. In comparisons between anesthesia methods with the transfemoral approach, most of the differences lost their significance. Therefore, these differences are most likely attributed to the surgical approach and not to the anesthesia method. CONCLUSIONS: There is no clear preference for GA in TAVI. LA-S appears to be an effective and safe option for eligible patients.


Assuntos
Anestesia/métodos , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Complicações Pós-Operatórias , Estudos Retrospectivos , Resultado do Tratamento
5.
Isr Med Assoc J ; 21(5): 308-313, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31140220

RESUMO

BACKGROUND: The MitraClip procedure is becoming an acceptable alternative for high-risk patients with mitral regurgitation (MR) due to functional (FMR) or degenerative (DMR) disease and suitable mitral anatomy. OBJECTIVES: To evaluate the results of MitraClip at our institute in carefully selected patients. METHODS: We conducted a retrospective analysis of medical records and echocardiography data from January 2012 to December 2017. RESULTS: A total of 39 MitraClip procedures in 37 patients (aged 75 ± 12 years, 9 women) was performed. Twenty-four patients presented with FMR, 12 with DMR, and 1 with combined pathology. One-day post-procedure MR was moderate to low in 86.1% of patients, with immediate device success in 88.8%. MR at 1 year was moderate to low in 79% at 1 year. Survival at 1 year was 86% and at 2 years 69.4%. Peri-procedural (< 1 week) death and MitraClip failure occurred in one and three patients, respectively. New York Heart Association score improved to class 1 or 2 in 37% of patients at 1 year vs. one patient at baseline. Post-procedural systolic pulmonary pressure was reduced from 53 (range 48-65) to 43 (range 36-52) mmHg at 1 month with a subsequent plateau at follow-up, to 41 (34-57) mmHg at 6 months, and to 47 (38-50) at 12 months. CONCLUSIONS: MitraClip in severe MR resulted in modest improvement in functional status and pulmonary pressure with a small risk of immediate procedural complications. Outcomes are encouraging considering the natural course of MR and the risks of surgical intervention.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Complicações Pós-Operatórias , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia/métodos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/cirurgia , Avaliação de Resultados em Cuidados de Saúde , Desempenho Físico Funcional , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Desenho de Prótese , Pressão Propulsora Pulmonar , Risco Ajustado , Índice de Gravidade de Doença , Análise de Sobrevida
6.
Catheter Cardiovasc Interv ; 91(7): 1371-1374, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-26946519

RESUMO

Systolic anterior motion (SAM) of the anterior mitral leaflet is a well reported complication of surgical mitral valve repair (MVR). In the current report, we present a case of SAM with left ventricular outflow tract obstruction (LVOTO) which occurred after transcatheter mitral valve repair (TMVR) using the MitraClip device. LVOTO was caused by the combination of protrusion of the MitraClip device into the LVOT and underfilling of the left ventricle due to pericardial effusion and atrial fibrillation. Rapid clinical resolution and marked decline in LVOT pressure gradient occurred following surgical drainage and windowing of the pericardium. We conclude that SAM and LVOTO could occur after TMVR. Seeking and addressing reversible aggravators of LVOTO including pericardial effusion is essential and could potentially make the difference between a successful procedure and a failed one. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Derrame Pericárdico/complicações , Obstrução do Fluxo Ventricular Externo/etiologia , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Derrame Pericárdico/diagnóstico por imagem , Derrame Pericárdico/fisiopatologia , Derrame Pericárdico/terapia , Desenho de Prótese , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Sístole , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/terapia
7.
Catheter Cardiovasc Interv ; 91(5): 1000-1004, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-27696650

RESUMO

Sutureless aortic bioprostheses (SAB) are increasingly being used to provide shorter cross-clamp time. Valve-in-valve transcatheter aortic valve replacement (VIV-A) is shown to be effective and safe in the vast majority of patients with degenerated bioprosthetics, yet its' use in SAB failure is infrequent. We present a case of balloon-expandable VIV-A in an 80-year-old woman who suffered severe symptomatic aortic regurgitation in a failed Perceval S 21-mm valve. Computed tomography scan demonstrated a deformed valve. Our heart team favored a percutaneous VIV-A over reoperation due to the patients' high surgical risk. An Edwards-Sapien XT 23 mm was successfully deployed with excellent results. The patient remained asymptomatic following 6 months. As other bioprosthesis, some sutureless valves are condemned to structural valve degeneration. Because VIV-A is being established for managing degenerative bioprosthesis in high risk patients, it is cardinal to identify its role in novel degenerative sutureless valves. SAB were introduced to the clinical market only 5-7 years ago. The absence of sutures may theoretically impose risk for valve instability when adding a transcatheter sutureless valve inside the first one. Our successful experience was very reassuring. We report its feasibility because we believe it should provide support for further investigation on VIV-A within novel SAV. © 2016 Wiley Periodicals, Inc.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Feminino , Hemodinâmica , Humanos , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Procedimentos Cirúrgicos sem Sutura , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 90(7): 1175-1182, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28544120

RESUMO

OBJECTIVE: To evaluate the effect of baseline aortic valve gradient (AVG) both as a continuous and a categorical variable on mortality in patients undergoing transcatheter aortic valve replacement (TAVR), focusing on the high-gradient severe aortic stenosis (AS) patients. BACKGROUND: Identifying new predictors of mortality in the TAVR population can help refine risk stratification and improve the patient selection process for this procedure. So far, AVG has mainly been studied as a categorical variable and there is a paucity of data on its prognostic value as a continuous variable, especially in patients with high AVG AS, who constitute the majority of patients referred for TAVR. METHODS: We analyzed data on 1,224 consecutive symptomatic severe AS patients, who underwent TAVR at 3 centers. The relation between pre-TAVR AVG and mortality was evaluated among all patients and in patients with high AVGs (mean AVG ≥40 mm Hg) using the Cox proportional hazard model adjusting for multiple variables. RESULTS: During a mean follow-up of 1.8 years, baseline AVG was inversely associated with mortality in the entire cohort and in patients with high AVG AS. By multivariable analysis, patients with mean AVG 40-60 mm Hg and >60 mm Hg had a respective 38% (P = 0.010) and 61% (P < 0.001) reduction in mortality compared to patients with mean AVG <40 mm Hg. Every 10 mm Hg increase in mean AVG was associated with 20% reduction in mortality (P < 0.001). Analyses among patients with high (mean AVG >40 mm Hg) and very high AVG AS (mean AVG >60 mm Hg) yielded similar results (HR = 0.88, P = 0.031, and HR = 0.80, P = 0.019, per 10 mm Hg increase in AVG, respectively). Using peak AVGs and an analysis restricted to patients without reduced ejection fraction yielded consistent results. CONCLUSIONS: Baseline AVGs show an inverse association with mortality post-TAVR. These results were consistent also in patients with high-gradient AS, suggesting that AVG can be used to identify patients most likely to benefit from TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Hemodinâmica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Distribuição de Qui-Quadrado , Feminino , Humanos , Israel , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
9.
J Heart Valve Dis ; 26(5): 509-517, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-29762919

RESUMO

BACKGROUND: Transthoracic echocardiography (TTE) is the standard method for evaluating the severity of aortic stenosis (AS), while transesophageal echocardiography (TEE) is useful for morphologic characterization. The study aim was to assess the impact of complementary TEE to TTE in refining hemodynamic assessment of AS severity. METHODS: A retrospective analysis was conducted of sequential TTE and TEE studies performed in 100 patients with moderate or severe AS confirmed on prior TTE. The left ventricular outflow tract (LVOT) velocity-time-integral (VTI1) and the aortic valve velocity-time integral (VTI2) were measured for both modalities. The highest values of VTI1 and VTI2 and mean gradients and peak velocities were selected from the sequential TTE/TEE study for indexed aortic valve area (AVAi) calculation and AS severity determination through an integrated assessment. RESULTS: AVAi determined by TTE was not significantly different from that determined by TEE (mean difference -0.008 cm2; p = 0.38). The dimensionless velocity index (DVI) was higher when assessed by TTE than by TEE (mean difference 0.0126 ± 0.04; p = 0.003). Using the integrated AS assessment, six of 13 patients with a TTE-based diagnosis of moderate AS were re-classified as severe AS. A slight lowering of the recommended TTE-derived DVI threshold for severe AS, from 0.25 to 0.24, improved the ability to discriminate moderate versus severe AS, as determined by the integrated assessment. CONCLUSIONS: TEE integrated with TTE may improve the detection of severe AS, particularly in patients with moderate AS criteria assessed by TTE, but with a DVI ratio ≤0.24.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos , Idoso , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Pesquisa Comparativa da Efetividade , Precisão da Medição Dimensional , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
10.
Cardiology ; 134(2): 128-35, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26953820

RESUMO

OBJECTIVES: To explore the relation between the baseline aortic valve gradient (AVG) as a continuous variable and clinical outcomes following transcatheter aortic valve implantation (TAVI) in general and specifically in patients with high-gradient aortic stenosis (AS). METHODS: We reviewed 317 consecutive patients who underwent TAVI at our institution. We investigated the relation between AVG as a continuous/categorical variable and outcome among all patients and in patients without low-flow low-gradient AS, using the Cox proportional hazard model adjusting for multiple prognostic variables. RESULTS: Patients had a peak AVG of 79.9 ± 22.8 mm Hg (mean 50.5 ±15.7). During a mean follow-up of 2.7 years, AVG was inversely associated with mortality and mortality or cardiac hospitalization. Every 10-mm-Hg increase in peak AVG was associated with 18% reduction in mortality (p = 0.003) and 19% reduction in mortality/cardiac hospitalization (p < 0.001). Every 10-mm-Hg increase in mean AVG was associated with a 24% reduction in both outcomes (p = 0.005 and p < 0.001). Subgroup analysis of patients with left-ventricular ejection fraction >40% or peak AVG >64 mm Hg yielded similar results. CONCLUSIONS: Mean and peak baseline AVGs are directly associated with improved outcomes after TAVI; AVG can be used to select the patients most likely to benefit from TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
11.
J Heart Valve Dis ; 25(2): 157-161, 2016 03.
Artigo em Inglês | MEDLINE | ID: mdl-27989059

RESUMO

BACKGROUND: Although significant late tricuspid regurgitation (TR) may develop after surgery for degenerative mitral regurgitation (MR), the use of routine tricuspid annuloplasty is debatable. The study aim was to determine the prevalence and predictors of significant late TR after surgery for degenerative MR. METHODS: A total of 112 patients who had undergone surgery for degenerative MR without concomitant tricuspid valve repair (average follow up 7.7 ± 4.0 years) was studied retrospectively. The prevalence of post-surgical TR and predictors of progression were determined. RESULTS: The majority of patients (97%) had non-significant TR (less than moderate) prior to surgery, although an overall trend of progression towards significant TR (grades 2 or 3) was noted in 17 patients (p = 0.0006). Of the 18 patients (16%) with late postoperative significant TR, only nine (8%) had severe TR with only a single referral to surgery. New-onset post-surgical atrial fibrillation was more common in patients who developed late significant TR (p = 0.002). Multivariate analysis of the pre-surgery variables, age >65 years and left ventricular dysfunction were shown to be independent predictors of late functional TR. CONCLUSIONS: Significant progression in TR after surgery for degenerative MR was rare in this patient cohort. The impact of older age and left ventricular dysfunction at the time of surgery showed a strong association with post-surgical atrial fibrillation.


Assuntos
Implante de Prótese de Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Mitral/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/epidemiologia , Valva Tricúspide/fisiopatologia , Fatores Etários , Idoso , Fibrilação Atrial/epidemiologia , Intervalo Livre de Doença , Feminino , Humanos , Israel/epidemiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/fisiopatologia , Análise Multivariada , Prevalência , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/fisiopatologia
12.
J Heart Valve Dis ; 24(3): 345-52, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26901911

RESUMO

BACKGROUND AND AIM OF THE STUDY: The percutaneous approach for a failed bioprosthetic valve is an emerging alternative to redo-valve surgery in patients at high surgical risk. The study aim was to describe the treatment of patients with structural bioprosthetic valve deterioration, using the valve-in-valve technique. METHODS: A total of 33 consecutive patients with symptomatic structural bioprosthetic valve deterioration was treated at the authors' institution, using the valve-in-valve technique. RESULTS: The valve-in-valve procedure in the aortic position was performed in 23 patients (mean age 81.4 ± 5.9 years; mean STS score 9.6 ± 5.4). The self-expandable and balloon-expandable devices were used in 21 cases (91.3%) and two cases (8.7%), respectively. Procedures were performed via the trans-femoral, trans-axillary and trans-apical routes in 18 (78.2%), three (13%) and two (8.7%) cases, respectively. After the procedure, all patients were in NYHA class I/II. Survival rates were 95.6% at the one-year follow up. The valve-in-valve procedure in the mitral position was performed in 10 patients (mean age 73.6 ± 15 years; mean STS score 7.7 ± 4.1). All procedures were performed using the balloon-expandable device via the trans-apical route. The composite end point of device success was achieved in all patients. Survival rates were 100% and 75% at one month and two years' follow up, respectively. A single valve-in-valve implantation within a failed tricuspid bioprosthetic valve was also successfully performed. CONCLUSION: In the authors' experience, the valve-in-valve technique for the treatment of a wide range of bioprosthetic valve deterioration modes of failure in different valve positions is safe and very effective.


Assuntos
Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Valvas Cardíacas/cirurgia , Idoso , Idoso de 80 Anos ou mais , Valvuloplastia com Balão , Feminino , Humanos , Masculino , Falha de Prótese , Reoperação
13.
J Heart Valve Dis ; 24(3): 272-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26901894

RESUMO

BACKGROUND AND AIM OF THE STUDY: The dynamics of left ventricular mass (LVM) regression following the relief of chronic left ventricular pressure overload are prone to variation. The study aim was to identify determinants of LVM regression following transcatheter aortic valve implantation (TAVI). METHODS: A total of 134 patients undergoing TAVI was identified. A retrospective analysis was performed of LVM indexed to body surface area (LVMi), calculated using transthoracic echocardiography at baseline and at six to 12 months post-TAVI. RESULTS: At six to 12 months after TAVI, there was a significant reduction in mean LVMi (from 118.2 ± 26.67 g/m2 to 103.4 ± 27.07 g/m2; p < 0.001) driven by a decrease in left ventricular wall thickness. The relative wall thickness (RWT) was decreased (0.54 ± 0.10 cm versus 0.51 ± 0.09 cm; p = 0.006), whereas the prevalence of concentric remodeling (RWT ≥ 0.42) remained unchanged (85.1% versus 80.6%; p = 0.3). However, 47 patients (35.1%) demonstrated significant LVMi regression, but had a lower baseline LVMi than patients who demonstrated significant regression (109.8 ± 25.8 g/m2 versus 122 ± 26.1 g/m2; p = 0.008) but had otherwise similar characteristics. A greater magnitude of LVMi reduction was associated with a greater baseline LVMi (r = 0.39; p < 0.001), where patients with LVMi in the highest quartile had the most substantial reduction in LVMi (p < 0.001). Multivariable analysis identified pre-TAVI LVMi as the sole independent predictor of LVMi regression at six to 12 months post-TAVI (P = 0.45; 95% confidence interval 0.255-0.534; p < 0.001). CONCLUSION: LVM regression at six to months post-TAVI was variable, with about one-third of patients not showing a significant regression. Only baseline LVM predicted LVM regression; patients with a higher baseline LVM demonstrated a greater regression.


Assuntos
Estenose da Valva Aórtica/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/terapia , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Próteses Valvulares Cardíacas , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Masculino , Período Pós-Operatório , Estudos Retrospectivos , Índice de Gravidade de Doença
14.
J Heart Valve Dis ; 24(4): 439-44, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26897813

RESUMO

BACKGROUND AND AIM OF THE STUDY: In patients with aortic stenosis, mitral regurgitation (MR) is a common finding. Little is known regarding outcomes of MR in patients undergoing transcatheter aortic valve implantation (TAVI). The study aim was to characterize the short- and mid-term impact of the TAVI procedure on MR grade. METHODS: A total of 261 patients (59% females; mean age 82.1 +/- 6.9 years) undergoing TAVI was assessed for rates of significant MR and the severity of MR at baseline, and at one month and six months after the procedure. RESULTS: In patients with moderate MR or above at baseline (n = 26, 10% of the cohort), there was a mean reduction in grade of 1.5 +/- 1.1 and 1.8 +/- 1.4 after one and six months, respectively (p < 0.01). Reduction in MR grade (1+) at six months was identified in 54.1% (40/74) of patients with mild-moderate MR or greater, and in 88.5% (23/26) of those with moderate MR or above, and was associated with an improved NYHA functional class (correlation coefficient r = -0.294, p < 0.001). Multivariate analysis identified low pulmonary pressure and tricuspid regurgitation as independent predictors of improvements in MR. CONCLUSION: Among the present cohort of patients undergoing TAVI, those with MR at baseline showed an improvement in the severity of their MR. Patients with moderate MR regurgitation or above demonstrated the greatest improvement.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Distribuição de Qui-Quadrado , Ecocardiografia Doppler em Cores , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Israel , Modelos Lineares , Modelos Logísticos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Análise Multivariada , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Indução de Remissão , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 81(5): 871-81, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22915555

RESUMO

BACKGROUND: The study sought to assess the clinical profile, outcome, and predictors for mortality of "real-world" high-risk severe aortic stenosis patients according to the mode of treatment assigned. METHODS: Patients were referred to a dedicated clinic for meticulous screening and multidisciplinary team assessment and 343 were finally assigned treatment (age 81.3 ± 7.2 years, 42.3% men): transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN or CoreValve device, 100 (29.2%); surgical aortic valve replacement (SAVR), 61 (17.8%); balloon valvuloplasty (as definitive therapy), 27 (7.9%); medication only, 155 (45.2%). No patient was lost to follow-up. RESULTS: The balloon valvuloplasty group had a significantly higher 1-month mortality rate (18.5%) than the TAVR group (3%, P = 0.006) and medical therapy group (3.9%; P = 0.004), without significant difference from the SAVR group (11.5%, P = 0.5). One-year cumulative survival was significantly higher in the TAVR group (92%) than in the other groups (SAVR 71%, balloon valvuloplasty 61.5%, medication 65%; all P < 0.001). Among survivors, 1-year rates of high functional class (NYHA I/II) were as follows: TAVR, 84.6%; SAVR, 63.3%; balloon valvuloplasty, 18.2%; medication, 21.4% (TAVR vs. SAVR, P = 0.04; SAVR vs. balloon valvuloplasty or medical therapy, P = 0.01). On multivariate regression analysis, renal failure (hazard ratio [HR] = 5.3, P < 0.001), not performing TAVR (HR = 4.9, P < 0.001), and pulmonary pressure (10 mm Hg, HR = 1.2, P = 0.02) were independent predictors of 1-year mortality. CONCLUSIONS: TAVR, performed in carefully selected high-risk patients, is associated with an excellent survival rate and high functional class. Patients treated with another of the available modalities, including SAVR, had a worse outcome, regardless of which alternative treatment they receive.


Assuntos
Estenose da Valva Aórtica/terapia , Valvuloplastia com Balão , Cateterismo Cardíaco/métodos , Fármacos Cardiovasculares/uso terapêutico , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/tratamento farmacológico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Distribuição de Qui-Quadrado , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Israel , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Seleção de Pacientes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
16.
J Card Fail ; 18(8): 645-53, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22858081

RESUMO

BACKGROUND: The prevalence of heart failure (HF) among hospitalized elderly patients is high and steadily growing. However, because most studies have focused mostly on young patients, little is known about the clinical characteristics, echocardiographic measures, prognostic factors, and outcome of hospitalized elderly HF patients. METHODS AND RESULTS: We identified all HF patients aged ≥50 years who had undergone ≥1 echocardiography study and had been hospitalized during January 2000 to December 2009. A comparative analysis was performed between 3,897 "young" patients (aged 50-75 years) and 5,438 "elderly" patients (aged >75 years), followed for a mean 2.8 ± 2.6 years. Elderly HF patients were more often female (50% vs 35%; P < .0001) and had a higher prevalence of HF with preserved ejection fraction (64.8% vs 53%; P < .0001), more significant valvular disease (35.7% vs 32.5%; P < .0001), and lower rates of ischemic heart disease (65.5% vs 70.9%; P < .0001) and diabetes (34.4% vs 53.9%; P < .0001). Thirty-day and 1-year mortality rates were significantly higher among the elderly population (12.2% vs 6.9% [P < .0001] and 34.3% vs 21.2% [P < .0001], respectively). Prognostic markers differed significantly between age groups. Young-specific predictors were chronic renal failure, diastolic dysfunction, malignancy, and tricuspid regurgitation, whereas elderly-specific predictors were HF with reduced ejection fraction, chronic obstructive pulmonary disease, pulmonary hypertension, and mitral regurgitation. CONCLUSIONS: Hospitalized elderly, compared with young, HF patients differed in prevalence of cardiac and noncardiac comorbid conditions, echocardiographic parameters, and predictors of short- and intermediate-term mortality. Identifying unique features in the elderly population may render age-tailored therapeutics.


Assuntos
Insuficiência Cardíaca/patologia , Hospitalização , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/uso terapêutico , Distribuição de Qui-Quadrado , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/epidemiologia , Humanos , Israel/epidemiologia , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Prevalência , Prognóstico , Estudos Retrospectivos , Medição de Risco/métodos , Resultado do Tratamento , Ultrassonografia
17.
Harefuah ; 151(4): 237-41, 252, 2012 Apr.
Artigo em Hebraico | MEDLINE | ID: mdl-22616154

RESUMO

Aortic valve stenosis is associated with severe morbidity and death within several years of symptom onset, and its accepted treatment is surgical aortic valve replacement. However, many affected patients are not referred for surgery because of old age and significant comorbidities. In recent years, an alternative treatment approach has been developed, transcatheter aortic-valve implantation. In this review we would like to describe this treatment modality and to present several cases performed in our center.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo/métodos , Implante de Prótese de Valva Cardíaca/métodos , Fatores Etários , Idoso , Estenose da Valva Aórtica/fisiopatologia , Próteses Valvulares Cardíacas , Humanos
18.
Am J Cardiol ; 163: 77-84, 2022 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-34782124

RESUMO

Transthoracic echocardiography (TTE) is the gold standard for aortic stenosis (AS) assessment. Transesophageal echocardiography (TEE) provides better resolution, but its effect on AS assessment is unclear. To answer this question, we studied 56 patients with ≥moderate AS. Initial TTE (TTE1) was followed by conscious sedation with simultaneous TEE and TTE2. Based on conservative versus actionable implication, AS types were dichotomized into group A, comprising moderate and normal-flow low-gradient, and group B, comprising high gradient, low ejection fraction low-flow low-gradient, and paradoxical low-flow low-gradient AS. Paired analysis of echocardiographic variables and AS types measured by TEE versus TTE2 and by TEE versus TTE1 was performed. TEE versus simultaneous TTE2 comparison demonstrated higher mean gradients (31.7 ± 10.5 vs 27.4 ± 10.5 mm Hg) and velocities (359 ± 60.6 vs 332 ± 63.1 cm/s) with TEE, but lower left ventricular outflow velocity-time-integral (VTI1) (18.6 ± 5.1 vs 20.2 ± 6.1 cm), all p <0.001. This resulted in a lower aortic valve area (0.8 ± 0.21 vs 0.87 ± 0.28 cm2), p <0.001, and a net relative risk of 1.86 of group A to B upgrade. TEE versus (awake state) TTE1 comparison revealed a larger decrease in VTI1 because of a higher initial awake state VTI1 (22 ± 5.6 cm), resulting in similar Doppler-velocity-index and aortic valve area decrease with TEE, despite a slight increase in mean gradients of 0.8 mm Hg (confidence interval -1.44 to 3.04) and velocities of 10 cm/s (confidence interval -1.5 to 23.4). This translated into a net relative risk of 1.92 of group A to B upgrade versus TTE1. In conclusion, TEE under conscious sedation overestimates AS severity compared with both awake state TTE and simultaneous sedation state TTE, accounted for by different Doppler insonation angles obtained in transapical versus transgastric position.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos , Volume Sistólico/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Sedação Consciente , Ecocardiografia Doppler/métodos , Feminino , Humanos , Masculino , Índice de Gravidade de Doença
19.
J Clin Med ; 11(9)2022 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-35566791

RESUMO

The valve-in-valve (ViV) technique is an emerging alternative for the treatment of bioprosthetic structural valve deterioration (SVD) in the tricuspid position. We report on the outcomes of patients treated by a transcatheter tricuspid valve-in-valve (TT-ViV) implantation for symptomatic SVD in the tricuspid position during the years 2010-2019 at our center. Three main outcomes were examined during the follow-up period: TT-ViV hemodynamic data per echocardiography, mortality and NYHA functional class. Our cohort consisted of 12 patients with a mean age 65.4 ± 11.9 years, 83.3% male. The mean time from initial valve intervention to TT-ViV was 17.4 ± 8.7 years. The indications for TT-ViV were varied (41.7% for predominant regurgitation, 33.3% for predominant stenosis and 25.0% with a mixed pathology). All patients were treated with a balloon-expandable device. The mean follow-up was 3.4 ± 1.3 years. Tricuspid regurgitation was ≥ moderate in 57.2% of patients prior to the procedure and this decreased to 0% following the procedure. The mean transtricuspid valve gradients mildly decreased from the mean pre-procedural values of 9.0 mmHg to 7.0 mmHg at one month following the procedure (p = 0.36). Mortality at one year was 8.0% (95% CI 0-23). At the baseline, 4 patients (33.3%) were in NYHA functional class III/IV; this was reduced to 2 patients (18.2%) at the one year follow-up and both were in NYHA III. The TT-ViV procedure offered a safe, feasible and less invasive treatment option for patients with SVD in our detailed cohort.

20.
Front Cardiovasc Med ; 9: 883242, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35557522

RESUMO

The Valve-in-Valve (ViV) technique is an emerging alternative for the treatment of bioprosthetic structural valve deterioration (SVD) in the mitral position. We report on intermediate-term outcomes of patients with symptomatic SVD in the mitral position who were treated by transcatheter mitral valve-in-valve (TM-ViV) implantation during the years 2010-2019 in our center. Three main outcomes were examined during the follow-up period: NYHA functional class, TM-ViV hemodynamic data per echocardiography, and mortality. Our cohort consisted of 49 patients (mean age 77.4 ± 10.5 years, 65.3% female). The indications for TM-ViV were mainly for regurgitant pathology (77.6%). All 49 patients were treated with a balloon-expandable device. The procedure was performed via transapical access in 17 cases (34.7%) and transfemoral vein/trans-atrial septal puncture in 32 cases (65.3%). Mean follow-up was 4.4 ± 2.0 years. 98% and 91% of patients were in NYHA I/II at 1 and 5 years, respectively. Mitral regurgitation was ≥moderate in 86.3% of patients prior to the procedure and this decreased to 0% (p < 0.001) following the procedure and was maintained over 2 years follow-up. The mean trans-mitral valve gradients decreased from pre-procedural values of 10.1 ± 5.1 mmHg to 7.0 ± 2.4 mmHg at 1 month following the procedure (p = 0.03). Mortality at 1 year was 16% (95%, CI 5-26) and 35% (95%, CI 18-49) at 5 years. ViV in the mitral position offers an effective and durable treatment option for patients with SVD at high surgical risk.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA