Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Acta Orthop ; 80(1): 14-9, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19234883

RESUMO

BACKGROUND AND PURPOSE: Periprosthetic bone loss after uncemented femoral hip revision is a matter of concern. We have used a proximally porous- and hydroxyapatite-coated prosthesis (Bi-Metric) in revision since 1989 and now we report the bone changes. This prosthesis is intended to distribute the forces more evenly and to avoid proximal femoral unloading. METHODS: 22 patients were unilaterally reoperated because of aseptic loosening. Only patients with a healthy contralateral hip were included. Mean age at revision was 69 (55-80) years. Bone defects were graded by Gustilo-Pasternak and Endo-Klinik classifications. Clinical assessment was performed with Harris hip score. We used radiographs and dual-energy X-ray absorptiometry to evaluate migration, femoral remodeling, and bone mineral density after 72 (30-158) months. RESULTS: The mean Harris hip score was 74 (30-100) points at follow-up. Mild thigh discomfort was present in 1 patient and moderate thigh pain in 3 patients. There was no loosening or subsidence. Osteolysis seen at revision had diminished in 19 of the 22 hips at follow-up. We noted a large reduction in bone mineral density. It was most pronounced in Gruen regions 1, 2, 6, and 7. INTERPRETATION: Revision with this stem is a reliable procedure; however, we noted a large degree of proximal bone loss that could lead to later mechanical complications or fractures.


Assuntos
Artroplastia de Quadril , Reabsorção Óssea/etiologia , Prótese de Quadril , Falha de Prótese , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Materiais Biocompatíveis , Densidade Óssea/fisiologia , Reabsorção Óssea/diagnóstico por imagem , Durapatita , Feminino , Fêmur/diagnóstico por imagem , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Desenho de Prótese , Radiografia , Reoperação
2.
Acta Orthop ; 77(3): 386-92, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16819676

RESUMO

BACKGROUND: Periprosthetic bone loss occurs around uncemented femoral stems and may be influenced by the stem size. PATIENTS AND METHODS: We studied 138 consecutive patients, 3 (2-7) years on average after a total hip arthroplasty operation (THA) for unilateral osteoarthritis with the Bi-Metric uncemented femoral stem. We analyzed Harris hip score and bone mineral density. RESULTS: The mean Harris hip score was 97 at follow-up. Bone mineral density decreased proximally by 19% in both Gruen zones 1 and 7. Bone loss in zones 1, 2, 6, and 7 was significantly associated with stem size. Distally, a small gain in bone mass was found in zones 3 and 5 for medium femoral sizes. INTERPRETATION: We found a marked proximal BMD loss, especially for the larger stems, which may be specific for this particular implant. Long-term studies should reveal whether this proximal bone loss will affect the longevity of the THA.


Assuntos
Artroplastia de Quadril/efeitos adversos , Densidade Óssea , Fêmur/patologia , Absorciometria de Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Seguimentos , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/patologia , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Fatores de Tempo
3.
Acta Orthop ; 77(6): 877-85, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17260195

RESUMO

BACKGROUND: Periprosthetic bone loss is a well-documented phenomenon after uncemented total hip arthroplasty (THA); however, little is known about how bone mineral density (BMD) changes after 2 years. PATIENTS AND METHODS: 14 patients with hip arthrosis (group A) were operated with a proximally porous- and hydroxyapatite-coated stem and followed for 10 years with DEXA, radiographs and Harris hip score (HHS). Another group of 14 patients (group B) was evaluated at 6 and 14 years using the same prosthesis and protocol. RESULTS: No stem was revised and all stems were well-Fixed. At final follow-up, HHS was 97 points in group A after 10 years and 94 points in group B after 14 years. Bone mineral changes in group A were greatest in Gruen zones 1 and 7, where the losses were 31% and 26%, respectively, after 2 years on the operated side. The decrease in BMD continued after 2 years and in Gruen zone 7 it was faster than the rate of bone loss on the control side. In group B, the annual change in BMD on the operated side was not significantly different from the bone loss in group A. INTERPRETATION: Up to 14 years after implantation of a tapered uncemented stem, the BMD in the calcar region continues to decrease faster than would be expected from normal ageing.


Assuntos
Artroplastia de Quadril/efeitos adversos , Densidade Óssea , Absorciometria de Fóton , Idoso , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA