Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Thyroid ; 7(6): 847-52, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9459627

RESUMO

The present study was undertaken to evaluate the contribution of pinhole-single photon emission computed tomography (P-SPECT) to scintigraphy of the thyroid gland. Thirty-six patients, referred for thyroid scintigraphy because of palpatory or ultrasonographic findings, were studied after intravenous administration of technetium-99m pertechnetate (222 MBq) using a rectilinear scanner and a single-headed rotating gamma camera equipped with a pinhole collimator. P-SPECT study was acquired on a 128 x 128 matrix, in 30 projections over 180 degrees and an acquisition time of 40 seconds per step. After transaxial reconstruction, coronal slices were compared with planar views obtained by the scanner. The size of the thyroid gland obtained by P-SPECT matched the life-size image of a rectilinear scan, and it clearly delineated the shape and borders of two huge multinodular glands. Its major contribution was in its improved resolution. Pinhole-SPECT identified 21 foci not visualized on planar views, 19 cold lesions, and 2 "warm" nodules embedded in normal tissue of 13 patients. Furthermore, it clearly delineated 18 discrete ill-defined nodules of 13 patients, (single in 4 patients and multiple in 9 patients): 16 cold lesions, and 2 hot foci. When a distinct palpable nodule was present, whether cold (22 lesions) or hot (2 foci), SPECT was of no additional diagnostic value. However, when the palpable nodule was a toxic one, the contralateral suppressed lobe was visible on SPECT only. Two ultrasonographic findings, of 3- and 5-mm in diameter, were neither identified on planar views nor on P-SPECT. In conclusion, P-SPECT of the thyroid gland improves delineation of huge multinodular glands and detection of small nodules (within the resolution of the camera) that could otherwise have been overlooked on planar views of a thyroid scanner. It allows for definition of tracer uptake in tiny discrete nodules and in multinodular goiter, and is a better guide to the physician in fine-needle aspiration of the cold areas.


Assuntos
Doenças da Glândula Tireoide/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Feminino , Bócio/diagnóstico , Bócio/diagnóstico por imagem , Humanos , Masculino , Radiografia , Doenças da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico , Nódulo da Glândula Tireoide/diagnóstico por imagem , Tireotoxicose/diagnóstico , Tireotoxicose/diagnóstico por imagem
2.
J Pharm Biomed Anal ; 13(6): 777-84, 1995 May.
Artigo em Inglês | MEDLINE | ID: mdl-7669832

RESUMO

A simple, stability-indicating liquid chromatographic method has been developed for the assay of flunarizine dihydrochloride in the presence of its acid-induced degradation product. A Bondapak-C18 column was used with a mobile phase consisting of methanol-water (75:25, v/v) containing 0.5% w/v sodium chloride and 0.2% v/v triethanolamine adjusted to pH 6.6 with 30% hydrochloric acid at a flow rate 2 ml min-1. Quantitation was achieved with UV detection at 254 nm based on peak area or peak height ratios. The proposed method was successfully applied to the determination of the drug in laboratory-prepared mixtures in the presence of its degradation product and in capsules. Moreover, the method was utilized to investigate the kinetics of the degradation process at different temperatures and the apparent first-order rate constant, half-life and activation energy calculated.


Assuntos
Flunarizina/análise , Cromatografia Líquida de Alta Pressão , Formas de Dosagem/normas , Etanolaminas/química , Flunarizina/metabolismo , Meia-Vida , Ácido Clorídrico/química , Concentração de Íons de Hidrogênio , Cinética , Espectrometria de Massas , Metanol/química , Padrões de Referência , Cloreto de Sódio/química , Espectrofotometria Ultravioleta , Estereoisomerismo , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA