1.
Stereotact Funct Neurosurg ; : 1-6, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834047

RESUMO

INTRODUCTION: Magnetic resonance guided focused ultrasound (MRgFUS) thalamotomy is an effective treatment for drug-resistant tremor. The most frequent side effects are ataxia, gait disturbance, paresthesias, dysgeusia, and hemiparesis. Here, we report the first case of thalamic hand dystonia rapidly occurring after MRgFUS thalamotomy of the ventral intermediate nucleus (V.im). CASE PRESENTATION: MRgFUS thalamotomy was performed in a 60-year-old left-handed patient for his disabling medically refractory essential tremor. The intervention resulted in a marked reduction of his action tremor. However, the patient developed an unvoluntary abnormal posture in his left hand a few days after the procedure with difficulty holding a cigarette between his fingers. Brain MRI revealed the expected MRgFUS lesion within the right V.im as well as an extension of the lesion anteriorly to the V.im in the ventro-oralis nucleus. Tractography showed that the lesion disrupted the dentato-rubro-thalamic tract as expected with a lesion suppressing tremor. However, the lesion also was interrupted fibers connecting to the superior frontal and pre-central cortices (primary motor cortex, premotor cortex, and supplementary area). We hypothesized that the interventional MRgFUS thalamotomy was slightly off target, which induced a dysfunction within the cortico-striato-thalamo-cortical network and the cerebello-thalamo-cortical pathway reaching a sufficient threshold of basal ganglia/cerebellum circuitry interference to induce dystonia. CONCLUSION: This rare side effect emphasizes the risk of imbalance within the dystonia network (i.e., basal ganglia-cerebello-thalamo-cortical circuit) secondary to V.im thalamotomy.

2.
Neuroradiology ; 65(12): 1793-1802, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37848741

RESUMO

PURPOSE: This article evaluates the feasibility, safety, and efficacy of MRI-guided lumbar or sacral nerve root infiltration for chronic back pain. We compared the outcomes of our MRI-guided infiltrations with data from CT-guided infiltrations reported in the literature and explored the potential advantages of MRI guidance. METHOD: Forty-eight MRI-guided nerve root infiltrations were performed using a 3 T MRI machine. The optimal needle path was determined using breathhold T2-weighted sequences, and the needle was advanced under interleaved guidance based on breathhold PD-weighted images. Pain levels were assessed using a numeric rating scale (NRS) before the procedure and up to 5 months after, during follow-up. Procedure success was evaluated by comparing patients' pain levels before and after the infiltration. RESULTS: The MRI-guided infiltrations yielded pain reduction 1 week after the infiltration in 92% of cases, with an average NRS substantial change of 3.9 points. Pain reduction persisted after 5 months for 51% of procedures. No procedure-related complications occurred. The use of a 22G needle and reconstructed subtraction images from T2 FatSat sequences improved the workflow. CONCLUSION: Our study showed that MRI-guided nerve root infiltration is a feasible, safe, and effective treatment option for chronic back pain. Precise positioning of the needle tip and accurate distribution of the injected solution contributed to the effectiveness of MRI-guided infiltration, which appeared to be as accurate as CT-guided procedures. Further research is needed to explore the potential benefits of metal artifact reduction sequences to optimize chronic back pain management.


Assuntos
Região Lombossacral , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Raízes Nervosas Espinhais , Dor nas Costas , Vértebras Lombares/diagnóstico por imagem , Resultado do Tratamento
3.
Stereotact Funct Neurosurg ; 101(6): 380-386, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37918368

RESUMO

We report the case of a 67-year-old left-handed female patient with disabling medically refractory essential tremor who underwent successful right-sided magnetic resonance-guided focused ultrasound (MRgFUS) of the ventral intermediate nucleus after ipsilateral gamma knife radiosurgery (GKRS) thalamotomy performed 3 years earlier. The GKRS had a partial effect on her postural tremor without side effects, but there was no reduction of her kinetic tremor or improvement in her quality of life (QoL). The patient subsequently underwent a MRgFUS thalamotomy, which induced an immediate and marked reduction in both the postural and kinetic tremor components, with minor complications (left upper lip hypesthesia, dysmetria in her left hand, and slight gait ataxia). The MRgFUS-induced lesion was centered more medially than the GKRS-induced lesion and extended more posteriorly and inferiorly. The MRgFUS-induced lesion interrupted remaining fibers of the dentatorubrothalamic tract (DRTT). The functional improvement 1-year post-MRgFUS was significant due to a marked reduction of the patient's kinetic tremor. The QoL score (Quality of Life in Essential Tremor) improved by 88% and her Clinical Rating Scale for Tremor left hand score by 62%. The side effects persisted but were minor, with no impact on her QoL. The explanation for the superior efficacy of MRgFUS compared to GKRS in our patient could be due to either a poor response to the GKRS or to a better localization of the MRgFUS lesion with a more extensive interruption of DRTT fibers. In conclusion, MRgFUS can be a valuable therapeutic option after unsatisfactory GKRS, especially because MRgFUS has immediate clinical effectiveness, allowing intra-procedural test lesions and possible readjustment of the target if necessary.


Assuntos
Tremor Essencial , Radiocirurgia , Humanos , Feminino , Idoso , Tremor Essencial/diagnóstico por imagem , Tremor Essencial/cirurgia , Qualidade de Vida , Tremor/cirurgia , Tálamo/diagnóstico por imagem , Tálamo/cirurgia , Imageamento por Ressonância Magnética , Resultado do Tratamento
4.
Int J Hyperthermia ; 39(1): 108-119, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35000497

RESUMO

Purpose: Micron-sized perfluorocarbon droplet adjuvants to focused ultrasound therapies allow lower applied power, circumvent unwanted prefocal heating, and enhance thermal dose in highly perfused tissues. The heat enhancement has been shown to saturate at increasing concentrations. Experiments were performed to empirically model the saturating heating effects during focused ultrasound.Materials and methods: The measurements were made at varying concentrations using magnetic resonance thermometry and focused ultrasound by circulating droplets of mean diameter 1.9 to 2.3 µm through a perfused phantom. A simulation was performed to estimate the interaction radius size, empirically.Results: The interaction radius, representing the radius of a sphere encompassing 90% of the probability for the transformation of acoustic energy into heat deposition around a single droplet, was determined experimentally from ultrasonic absorption coefficient measurements The simulations suggest the interaction radius was approximately 12.5-fold larger than the geometrical radius of droplets, corresponding to an interaction volume on the order of 2000 larger than the geometrical volume.Conclusions: The results provide information regarding the dose-response relationship from the droplets, a measure with 15% precision of their interaction radii with focused ultrasound, and subsequent insights into the underlying physical heating mechanism.


Assuntos
Fluorocarbonos , Ablação por Ultrassom Focalizado de Alta Intensidade , Termometria , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Hidrocarbonetos Bromados , Imageamento por Ressonância Magnética/métodos , Rádio (Anatomia) , Termometria/métodos
5.
Int J Hyperthermia ; 39(1): 547-556, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35313781

RESUMO

Optimization of treatment strategies for prostate cancer patients treated with curative radiation therapy (RT) represents one of the major challenges for the radiation oncologist. Dose escalation or combination of RT with systemic therapies is used to improve tumor control in patients with unfavorable prostate cancer, at the risk of increasing rates and severity of treatment-related toxicities. Elevation of temperature to a supra-physiological level has been shown to both increase tumor oxygenation and reduce DNA repair capabilities. Thus, hyperthermia (HT) combined with RT represents a compelling treatment strategy to improve the therapeutic ratio in prostate cancer patients. The aim of the present systematic review is to report on preclinical and clinical evidence supporting the combination of HT and RT for prostate cancer, discussing future applications and developments of this combined treatment.


Assuntos
Hipertermia Induzida , Neoplasias da Próstata , Terapia Combinada , Humanos , Hipertermia , Masculino , Neoplasias da Próstata/radioterapia
6.
Neuroradiology ; 63(9): 1569-1573, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33909116

RESUMO

Cortical microinfarcts (CMI) are increasingly recognized in the neurological community as a biomarker related to cognitive impairment and dementia. If their radiological depiction has been largely described in experimental settings using ultra-high-field magnetic resonance imaging (MRI), less is known about their visibility on routinely used 3-T MRI. In this radiologic-pathologic correlation study, using 3-T post-mortem MRI, we searched for hippocampal CMI, in a double-blinded fashion, and found that only 4/36, or 11%, were clearly demonstrated on both radiological and histopathological exams.


Assuntos
Infarto Cerebral , Imageamento por Ressonância Magnética , Hipocampo/diagnóstico por imagem , Humanos
7.
BMC Med Imaging ; 21(1): 110, 2021 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-34253181

RESUMO

BACKGROUND: For the treatment of radicular pain, nerve root infiltrations can be performed under MRI guidance in select, typically younger, patients where repeated CT exams are not desirable due to associated radiation risk, or potential allergic reactions to iodinated contrast medium. METHODS: Fifteen 3 T MRI-guided nerve root infiltrations were performed in 12 patients with a dedicated surface coil combined with the standard spine coil, using a breathhold PD sequence. The needle artifact on the MR images and the distance between the needle tip and the infiltrated nerve root were measured. RESULTS: The distance between the needle tip and the nerve root was 2.1 ± 1.4 mm. The visual artifact width, perpendicular to the needle long axis, was 2.1 ± 0.7 mm. No adverse events were reported. CONCLUSION: This technical note describes the optimization of the procedure in a 3 T magnetic field, including reported procedure time and an assessment of targeting precision.


Assuntos
Injeções Espinhais/métodos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Radiculopatia/tratamento farmacológico , Raízes Nervosas Espinhais/diagnóstico por imagem , Dexametasona/administração & dosagem , Feminino , Glucocorticoides/administração & dosagem , Humanos , Dor Lombar/tratamento farmacológico , Vértebras Lombares/inervação , Masculino , Pessoa de Meia-Idade , Ropivacaina/administração & dosagem , Nervo Isquiático/diagnóstico por imagem
8.
Int J Hyperthermia ; 37(1): 1116-1130, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32990101

RESUMO

BACKGROUND: High intensity focused ultrasound (HIFU) is clinically accepted for the treatment of solid tumors but remains challenging in highly perfused tissue due to the heat sink effect. Endovascular liquid-core sonosensitizers have been previously suggested to enhance the thermal energy deposition at the focal area and to lower the near-/far-field heating. We are investigating the therapeutic potential of PFOB-FTAC micro-droplets in a perfused tissue-mimicking model and postmortem excised organs. METHOD: A custom-made in vitro perfused tissue-mimicking model, freshly excised pig kidneys (n = 3) and liver (n = 1) were perfused and subjected to focused ultrasound generated by an MR-compatible HIFU transducer. PFOB-FTAC sonosensitizers were injected in the perfusion fluid up to 0.235% v/v ratio. Targeting and on-line PRFS thermometry were performed on a 3 T MR scanner. Assessment of the fluid perfusion was performed with pulsed color Doppler in vitro and with dynamic contrast-enhanced (DCE)-MRI in excised organs. RESULTS: Our in vitro model of perfused tissue demonstrated re-usability. Sonosensitizer concentration and perfusion rate were tunable in situ. Differential heating under equivalent HIFU sonications demonstrated a dramatic improvement in the thermal deposition due to the sonosensitizers activity. Typically, the energy deposition was multiplied by a factor between 2.5 and 3 in perfused organs after the administration of micro-droplets, while DCE-MRI indicated an effective perfusion. CONCLUSION: The current PFOB-FTAC micro-droplet sonosensitizers provided a large and sustained enhancement of the HIFU thermal deposition at the focal area, suggesting solutions for less technological constraints, lower risk for the near-/far- field heating. We also report a suitable experimental model for other MRgHIFU studies.


Assuntos
Fluorocarbonos , Ablação por Ultrassom Focalizado de Alta Intensidade , Termometria , Animais , Hidrocarbonetos Bromados , Imageamento por Ressonância Magnética , Suínos
9.
J Transl Med ; 17(1): 350, 2019 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-31651311

RESUMO

BACKGROUND: Magnetic resonance guided focused ultrasound was suggested for the induction of deep localized hyperthermia adjuvant to radiation- or chemotherapy. In this study we are aiming to validate an experimental model for the induction of uniform temperature elevation in osteolytic bone tumours, using the natural acoustic window provided by the cortical breakthrough. MATERIALS AND METHODS: Experiments were conducted on ex vivo lamb shank by mimicking osteolytic bone tumours. The cortical breakthrough was exploited to induce hyperthermia inside the medullar cavity by delivering acoustic energy from a phased array HIFU transducer. MR thermometry data was acquired intra-operatory using the proton resonance frequency shift (PRFS) method. Active temperature control was achieved via a closed-loop predictive controller set at 6 °C above the baseline. Several beam geometries with respect to the cortical breakthrough were investigated. Numerical simulations were used to further explain the observed phenomena. Thermal safety of bone heating was assessed by cross-correlating MR thermometry data with the measurements from a fluoroptic temperature sensor inserted in the cortical bone. RESULTS: Numerical simulations and MR thermometry confirmed the feasibility of spatio-temporal uniform hyperthermia (± 0.5 °C) inside the medullar cavity using a fixed focal point sonication. This result was obtained by the combination of several factors: an optimal positioning of the focal spot in the plane of the cortical breakthrough, the direct absorption of the HIFU beam at the focal spot, the "acoustic oven effect" yielded by the beam interaction with the bone, and a predictive temperature controller. The fluoroptical sensor data revealed no heating risks for the bone and adjacent tissues and were in good agreement with the PRFS thermometry from measurable voxels adjacent to the periosteum. CONCLUSION: To our knowledge, this is the first study demonstrating the feasibility of MR-guided focused ultrasound hyperthermia inside the medullar cavity of bones affected by osteolytic tumours. Our results are considered a promising step for combining adjuvant mild hyperthermia to external beam radiation therapy for sustained pain relief in patients with symptomatic bone metastases.


Assuntos
Neoplasias Ósseas/terapia , Hipertermia Induzida/métodos , Idoso , Animais , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Terapia Combinada , Simulação por Computador , Estudos de Viabilidade , Feminino , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Humanos , Técnicas In Vitro , Imageamento por Ressonância Magnética/métodos , Modelos Animais , Osteólise/diagnóstico por imagem , Osteólise/terapia , Ovinos , Análise Espaço-Temporal , Temperatura , Pesquisa Translacional Biomédica
10.
Neuroradiology ; 61(10): 1209-1213, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31396662

RESUMO

PURPOSE: Cerebral microbleeds (CMB) play an important role as an imaging biomarker notably in vascular and neurodegenerative diseases. Current clinical brain MRI underestimates the number of CMB with respect to histopathology. It is expected that small CMBs are more likely to be false-negatives, yet this has not been demonstrated and the average size of false-negative and true-positive CMBs have not been established. METHODS: The radiologic-histopathologic correlation study was approved by the local review board and included 42 consecutive cases (mean age at death, 80.7 ± 10.0 years; 23 females and 19 men) between 12 January 2012 and 10 December 2012 having undergone brain autopsy. Postmortem SWI (susceptibility-weighted imaging) images were acquired on a clinical 3T system using parameters similar to clinical routine. The detection of CMB on postmortem MRI was compared with corresponding histopathological slices. RESULTS: Postmortem MRI detected 23 true-positive CMB. Histopathology additionally detected 68 CMBs (false-negative MRI CMBs). The average size true-positive MRI CMBs had on histopathology was 3.6 ± 7.1 mm3. The average size false-negative MRI CMBs was significantly smaller (p < 0.05), measuring 0.3 ± 1.2 mm3 on histopathology. CONCLUSION: Size matters. As expected, the average size of true-positive MRI CMB was around 10 times larger as compared with false-negative MRI CMB. Evidently, in addition to size, other factors will influence the detectability of CMB, including iron content, ratio of Fe2+/Fe3+, spatial configuration, and location, yet this remains to be elucidated in future studies.


Assuntos
Hemorragia Cerebral/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Biomarcadores , Hemorragia Cerebral/patologia , Reações Falso-Negativas , Feminino , Humanos , Imageamento Tridimensional , Masculino
11.
Magn Reson Med ; 79(5): 2511-2523, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28944490

RESUMO

PURPOSE: Treatments using high-intensity focused ultrasound (HIFU) in the abdominal region remain challenging as a result of respiratory organ motion. A novel method is described here to achieve 3D motion-compensated ultrasound (US) MR-guided HIFU therapy using simultaneous ultrasound and MRI. METHODS: A truly hybrid US-MR-guided HIFU method was used to plan and control the treatment. Two-dimensional ultrasound was used in real time to enable tracking of the motion in the coronal plane, whereas an MR pencil-beam navigator was used to detect anterior-posterior motion. Prospective motion compensation of proton resonance frequency shift (PRFS) thermometry and HIFU electronic beam steering were achieved. RESULTS: The 3D prospective motion-corrected PRFS temperature maps showed reduced intrascan ghosting artifacts, a high signal-to-noise ratio, and low geometric distortion. The k-space data yielded a consistent temperature-dependent PRFS effect, matching the gold standard thermometry within approximately 1°C. The maximum in-plane temperature elevation ex vivo was improved by a factor of 2. Baseline thermometry acquired in volunteers indicated reduction of residual motion, together with an accuracy/precision of near-harmonic referenceless PRFS thermometry on the order of 0.5/1.0°C. CONCLUSIONS: Hybrid US-MR-guided HIFU ablation with 3D motion compensation was demonstrated ex vivo together with a stable referenceless PRFS thermometry baseline in healthy volunteer liver acquisitions. Magn Reson Med 79:2511-2523, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Algoritmos , Animais , Bovinos , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Masculino , Termometria/métodos
12.
Neuroradiology ; 60(10): 1089-1092, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30090981

RESUMO

Air bubble artifacts on SWI post-mortem MRI studies may interfere with the detection of cerebral microbleeds. We investigated whether the utilization of a higher receiver bandwidth of 500 Hz/pixel could reduce cortical air bubble artifacts without compromising the detection of cerebral microbleeds in high-field MRI. All microbleeds remained clearly visible whereas a reduction of 17% of the long axis of the "halo" magnitude artifacts was achieved. On corresponding phase images, air bubble artifacts appeared identical.


Assuntos
Ar , Artefatos , Encefalopatias/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Idoso , Idoso de 80 Anos ou mais , Autopsia , Encefalopatias/patologia , Feminino , Humanos , Masculino , Mudanças Depois da Morte
13.
Magn Reson Med ; 73(1): 417-26, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24478117

RESUMO

PURPOSE: MR-guided high-intensity contact ultrasound (HICU) was suggested as an alternative therapy for esophageal and rectal cancer. To offer high-quality MR guidance, two prototypes of receive-only opposed-solenoid coil were integrated with 64-element cylindrical phased-array ultrasound transducers (rectal/esophageal). METHODS: The design of integrated coils took into account the transducer geometry (360° acoustic window within endoluminal space). The rectal coil was sealed on a plastic support and placed reversibly on the transducer head. The esophageal coil was fully embedded within the transducer head, resulting in one indivisible device. Comparison of integrated versus external coils was performed on a clinical 1.5T scanner. RESULTS: The integrated coils showed higher sensitivity compared with the standard extracorporeal coil with factors of up to 7.5 (rectal applicator) and 3.3 (esophageal applicator). High-resolution MR images for both anatomy (voxel 0.4 × 0.4 × 5 mm(3)) and thermometry (voxel 0.75 × 0.75 × 8 mm(3), 2 s/image) were acquired in vivo with the rectal endoscopic device. The temperature feedback loop accurately controlled multiple control points over the region of interest. CONCLUSION: This study showed significant improvement of MR data quality using endoluminal integrated coils versus standard external coil. Inframillimeter spatial resolution and accurate feedback control of MR-guided HICU thermotherapy were achieved.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Aumento da Imagem/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imãs , Termografia/instrumentação , Transdutores , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
14.
Int J Hyperthermia ; 31(4): 421-32, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25753370

RESUMO

OBJECTIVE: The aim of this paper is to quantitatively investigate the thermal effects generated by the pre-focal interactions of a HIFU beam with a rib cage, in the context of minimally invasive transcostal therapy of liver malignancies. MATERIALS AND METHODS: HIFU sonications were produced by a phased-array MR-compatible transducer on Turkey muscle placed on a sheep thoracic cage specimen. The thoracic wall was positioned in the pre-focal zone 3.5 to 6.5 cm below the focus. Thermal monitoring was simultaneously performed using fluoroptic sensors inserted into the medullar cavity of the ribs and high resolution MR-thermometry (voxel: 1 × 1 × 5 mm3, four multi-planar slices). RESULTS: MR-thermometry data indicated nearly isotropic distribution of the thermal energy at the ribs' surface. The temperature elevation at the focus was comparable with the pericostal temperature elevation around unprotected ribs, while being systematically inferior, by more than a factor of four on average, to the intra-medullar values. The spatial profiles of the pericostal and intra-medullar thermal build-up measurements could be smoothly connected using a Gaussian function. The dynamics of the post-sonication thermal relaxation as determined by fluoroptic measurements was demonstrated to be theoretically coherent with the experimental observations. CONCLUSION: The experimental findings motivate further efforts for the transfer towards clinical routine of effective rib-sparing strategies for hepatic HIFU.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos , Costelas/efeitos da radiação , Termografia/métodos , Animais , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Temperatura Alta , Imageamento por Ressonância Magnética/efeitos adversos , Ovinos , Termometria , Transdutores , Perus
15.
J Transl Med ; 12: 12, 2014 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-24433332

RESUMO

BACKGROUND: Magnetic Resonance-guided High Intensity Focused Ultrasound (MRgHIFU) is a hybrid technology that aims to offer non-invasive thermal ablation of targeted tumors or other pathological tissues. Acoustic aberrations and non-linear wave propagating effects may shift the focal point significantly away from the prescribed (or, theoretical) position. It is therefore mandatory to evaluate the spatial accuracy of ablation for a given HIFU protocol and/or device. We describe here a method for producing a user-defined ballistic target as an absolute reference marker for MRgHIFU ablations. METHODS: The investigated method is based on trapping a mixture of MR contrast agent and histology stain using radiofrequency (RF) ablation causing cell death and coagulation. A dedicated RF-electrode was used for the marker fixation as follows: a RF coagulation (4 W, 15 seconds) and injection of the mixture followed by a second RF coagulation. As a result, the contrast agent/stain is encapsulated in the intercellular space. Ultrasonography imaging was performed during the procedure, while high resolution T1w 3D VIBE MR acquisition was used right after to identify the position of the ballistic marker and hence the target tissue. For some cases, after the marker fixation procedure, HIFU volumetric ablations were produced by a phased-array HIFU platform. First ex vivo experiments were followed by in vivo investigation on four rabbits in thigh muscle and six pigs in liver, with follow-up at Day 7. RESULTS: At the end of the procedure, no ultrasound indication of the marker's presence could be observed, while it was clearly visible under MR and could be conveniently used to prescribe the HIFU ablation, centered on the so-created target. The marker was identified at Day 7 after treatment, immediately after animal sacrifice, after 3 weeks of post-mortem formalin fixation and during histology analysis. Its size ranged between 2.5 and 4 mm. CONCLUSIONS: Experimental validation of this new ballistic marker method was performed for liver MRgHIFU ablation, free of any side effects (e.g. no edema around the marker, no infection, no bleeding). The study suggests that the absolute reference marker had ultrasound conspicuity below the detection threshold, was irreversible, MR-compatible and MR-detectable, while also being a well-established histology staining technique.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Espectroscopia de Ressonância Magnética , Animais , Feminino , Modelos Animais , Coelhos , Ondas de Rádio , Sonicação , Sus scrofa , Ultrassonografia
16.
Magn Reson Med ; 72(4): 1087-95, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24243500

RESUMO

PURPOSE: Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges. METHODS: MR acquisition consisted of thermometry performed with segmented gradient-recalled echo echo-planar imaging, and a segment-based one-dimensional MR navigator parallel to the main axis of motion to track the organ motion. This tracking information was used in real-time for: (i) prospective motion correction of MR thermometry and (ii) HIFU focal point position lock-on target. Ex vivo experiments were performed on a sheep liver and a turkey pectoral muscle using a motion demonstrator, while in vivo experiments were conducted on two sheep liver. RESULTS: Prospective motion correction of MR thermometry yielded good signal-to-noise ratio (range, 25 to 35) and low geometric distortion due to the use of segmented EPI. HIFU focal point lock-on target yielded isotropic in-plane thermal build-up. The feasibility of in vivo intercostal liver treatment was demonstrated in sheep. CONCLUSION: The presented method demonstrated in moving phantoms and breathing sheep accurate motion-compensated MR thermometry and precise HIFU focal point lock-on target using only real-time pencil-beam navigator tracking information, making it applicable without any pretreatment data acquisition or organ motion modeling.


Assuntos
Artefatos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento por Ressonância Magnética/métodos , Termografia/métodos , Vísceras/fisiologia , Vísceras/cirurgia , Abdome/fisiologia , Abdome/efeitos da radiação , Abdome/cirurgia , Animais , Temperatura Corporal/fisiologia , Temperatura Corporal/efeitos da radiação , Sistemas Computacionais , Ondas de Choque de Alta Energia , Aumento da Imagem/métodos , Técnicas In Vitro , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos , Cirurgia Assistida por Computador/métodos , Turquia , Vísceras/efeitos da radiação
17.
Diagnostics (Basel) ; 14(12)2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38928648

RESUMO

The emergence of 7T clinical MRI technology has sparked our interest in its ability to discern the complex structures of the hand. Our primary objective was to assess the sensory and motor nerve structures of the hand, specifically nerves and Pacinian corpuscles, with the dual purpose of aiding diagnostic endeavors and supporting reconstructive surgical procedures. Ethical approval was obtained to carry out 7T MRI scans on a cohort of volunteers. Four volunteers assumed a prone position, with their hands (N = 8) positioned in a "superman" posture. To immobilize and maintain the hand in a strictly horizontal position, it was affixed to a plastic plate. Passive B0 shimming was implemented. Once high-resolution 3D images had been acquired using a multi-transmit head coil, advanced post-processing techniques were used to meticulously delineate the nerve fiber networks and mechanoreceptors. Across all participants, digital nerves were consistently located on the phalanges area, on average, between 2.5 and 3.5 mm beneath the skin, except within flexion folds where the nerve was approximately 1.8 mm from the surface. On the phalanges area, the mean distance from digital nerves to joints was approximately 1.5 mm. The nerves of the fingers were closer to the bone than to the surface of the skin. Furthermore, Pacinian corpuscles exhibited a notable clustering primarily within the metacarpal zone, situated on the palmar aspect. Our study yielded promising results, successfully reconstructing and meticulously describing the anatomy of nerve fibers spanning from the carpus to the digital nerve division, alongside the identification of Pacinian corpuscles, in four healthy volunteers (eight hands).

18.
Ultrasound Med Biol ; 49(7): 1510-1517, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37117139

RESUMO

OBJECTIVE: Sonosensitive high-boiling point perfluorocarbon F8TAC18-PFOB emulsions previously exhibited thermal enhancement during focused ultrasound heating in ex vivo pig livers, kidneys and a laminar flow phantom. The main objectives of this study were to evaluate heating under turbulent conditions, observe perfusion effects, quantify heating in terms of acoustic absorption and model the experimental data. METHODS: In this study, similar perfluorocarbon emulsions were circulated at incremental concentrations of 0.07, 0.13, 0.19 and 0.25% v:v through a percolated turbulent flow phantom, more representative of the biological tissue than a laminar flow phantom. The concentrations represent the droplet content in only the perfused fluid, rather than the droplet concentration throughout the entire cross-section. The temperature was measured with magnetic resonance thermometry, during focused ultrasound sonications of 67 W, 95% duty cycle and 33 s duration. These were used in Bioheat equation simulations to investigate in silico the thermal phenomena. The temperature change was compared with the control condition by circulating de-gassed and de-ionized water through the flow phantom without droplets. RESULTS: With these 1.24 µm diameter droplets at 0.25% v:v, the acoustic absorption coefficient increased from 0.93 ± 0.05 at 0.0% v:v to 1.82 ± 0.22 m-1 at 0.25% v:v using a 0.1 mL s-1 flow rate. Without perfusion at 0.25% v:v, an increase was observed from 1.23 ± 0.07 m-1 at 0.0% v:v to 1.65 ± 0.17 m-1. CONCLUSION: The results further support previously reported thermal enhancement with F8TAC18-PFOB emulsion, quantified the increased absorption at small concentration intervals, illustrated that the effects can be observed in a variety of visceral tissue models and provided a method to simulate untested scenarios.


Assuntos
Fluorocarbonos , Ablação por Ultrassom Focalizado de Alta Intensidade , Animais , Suínos , Emulsões , Imageamento por Ressonância Magnética/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Espectroscopia de Ressonância Magnética , Acústica
19.
Cancers (Basel) ; 15(15)2023 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-37568777

RESUMO

BACKGROUND: HIFU ablation of liver malignancies is particularly challenging due to respiratory motion, high tissue perfusion and the presence of the rib cage. Based on our previous development of a super-convergent phased-array transducer, we aimed to further investigate, in vivo, its applicability to deep intrahepatic targets. METHODS: In a series of six pigs, a pseudo-tumor model was used as target, visible both on intra-operatory MRI and post-mortem gross pathology. The transcostal MRgHIFU ablation was prescribed coplanar with the pseudo-tumor, either axial or sagittal, but deliberately shifted 7 to 18 mm to the side. No specific means of protection of the ribs were implemented. Post-treatment MRI follow-up was performed at D7, followed by animal necropsy and gross pathology of the liver. RESULTS: The pseudo-tumor was clearly identified on T1w MR imaging and subsequently allowed the MRgHIFU planning. The peak temperature at the focal point ranged from 58-87 °C. Gross pathology confirmed the presence of the pseudo-tumor and the well-delineated MRgHIFU ablation at the expected locations. CONCLUSIONS: The specific design of the transducer enabled a reliable workflow. It demonstrated a good safety profile for in vivo transcostal MRgHIFU ablation of deep-liver targets, graded as challenging for standard surgery.

20.
Magn Reson Med ; 67(6): 1787-93, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22135014

RESUMO

We investigated a technique based on phase-contrast cine MRI combined with deconvolution of the phase shift waveforms to measure rapidly varying pulsatile motion waveforms. The technique does not require steady-state displacement during motion encoding. Simulations and experiments were performed in porcine liver samples in view of a specific application, namely the observation of transient displacements induced by acoustic radiation force. Simulations illustrate the advantages and shortcomings of the methods. For experimental validation, the waveforms were acquired with an ultrafast ultrasound scanner (Supersonic Imagine Aixplorer), and the rates of decay of the waveforms (relaxation time) were compared. With bipolar motion-encoding gradient of 8.4 ms, the method was able to measure displacement waveforms with a temporal resolution of 1 ms over a time course of 40 ms. Reasonable agreement was found between the rate of decay of the waveforms measured in ultrasound (2.8 ms) and in MRI (2.7-3.3 ms).


Assuntos
Algoritmos , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/fisiologia , Imageamento por Ressonância Magnética/métodos , Fluxo Pulsátil/fisiologia , Animais , Módulo de Elasticidade/fisiologia , Aumento da Imagem/métodos , Movimento/fisiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Viscosidade