Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am Heart J ; 166(6): 1019-26, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24268216

RESUMO

BACKGROUND: The role of intraaortic balloon pump (IABP) during percutaneous coronary intervention (PCI) in high-risk acute patients remains debated. Device-related complications and the more complex patient management could explain such lack of clinical benefit. We aimed to assess the impact of transradial versus transfemoral access for PCI requiring IABP support on vascular complications and clinical outcome. METHODS: We retrospectively analyzed 321 consecutive patients receiving IABP support during transfemoral (n = 209) or transradial (n = 112) PCI. Thirty-day net adverse clinical events (NACEs) (composite of postprocedural bleeding, cardiac death, myocardial infarction, target lesion revascularization, and stroke) were the primary end point, with access-related bleeding and hospital stay as secondary end points. RESULTS: Cardiogenic shock and hemodynamic instability were the most common indications for IABP support. Cumulative 30-day NACE rate was 50.2%, whereas an access site-related bleeding occurred in 14.3%. Patients undergoing transfemoral PCI had a higher unadjusted rate of NACEs when compared with the transradial group (57.4% vs 36.6%, P < .01), mainly due more access-related bleedings (18.7% vs 6.3%, P < .01). Such increased risk of NACEs was confirmed after propensity score adjustment (hazard ratio 0.57 [0.4-0.9], P = .007), whereas hospital stay appeared comparable in the 2 groups. CONCLUSIONS: In this observational registry, high-risk patients undergoing PCI and requiring IABP support appeared to have fewer NACEs if transradial access was used instead of transfemoral, mainly due to fewer access-related bleedings. Given the inherent limitations of this retrospective work, including the inability to adjust for unknown confounders, further controlled studies are warranted to confirm or refute these findings.


Assuntos
Síndrome Coronariana Aguda/terapia , Artéria Femoral , Balão Intra-Aórtico/métodos , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Artéria Radial , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Balão Intra-Aórtico/efeitos adversos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
2.
J Pers Med ; 13(2)2023 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-36836550

RESUMO

BACKGROUND: Identifying sex-related differences/variables associated with 30 day/1 year mortality in patients with chronic limb-threatening ischemia (CLTI). METHODS: Multicenter/retrospective/observational study. A database was sent to all the Italian vascular surgeries to collect all the patients operated on for CLTI in 2019. Acute lower-limb ischemia and neuropathic-diabetic foot are not included. FOLLOW-UP: One year. Data on demographics/comorbidities, treatments/outcomes, and 30 day/1 year mortality were investigated. RESULTS: Information on 2399 cases (69.8% men) from 36/143 (25.2%) centers. Median (IQR) age: 73 (66-80) and 79 (71-85) years for men/women, respectively (p < 0.0001). Women were more likely to be over 75 (63.2% vs. 40.1%, p = 0.0001). More men smokers (73.7% vs. 42.2%, p < 0.0001), are on hemodialysis (10.1% vs. 6.7%, p = 0.006), affected by diabetes (61.9% vs. 52.8%, p < 0.0001), dyslipidemia (69.3% vs. 61.3%, p < 0.0001), hypertension (91.8% vs. 88.5%, p = 0.011), coronaropathy (43.9% vs. 29.4%, p < 0.0001), bronchopneumopathy (37.1% vs. 25.6%, p < 0.0001), underwent more open/hybrid surgeries (37.9% vs. 28.8%, p < 0.0001), and minor amputations (22% vs. 13.7%, p < 0.0001). More women underwent endovascular revascularizations (61.6% vs. 55.2%, p = 0.004), major amputations (9.6% vs. 6.9%, p = 0.024), and obtained limb-salvage if with limited gangrene (50.8% vs. 44.9%, p = 0.017). Age > 75 (HR = 3.63, p = 0.003) is associated with 30 day mortality. Age > 75 (HR = 2.14, p < 0.0001), nephropathy (HR = 1.54, p < 0.0001), coronaropathy (HR = 1.26, p = 0.036), and infection/necrosis of the foot (dry, HR = 1.42, p = 0.040; wet, HR = 2.04, p < 0.0001) are associated with 1 year mortality. No sex-linked difference in mortality statistics. CONCLUSION: Women exhibit fewer comorbidities but are struck by CLTI when over 75, a factor associated with short- and mid-term mortality, explaining why mortality does not statistically differ between the sexes.

3.
Catheter Cardiovasc Interv ; 79(1): 97-102, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21520391

RESUMO

BACKGROUND: Occupational radiation exposure is a growing problem due to the increasing number and complexity of interventional procedures performed. Radial artery access has reduced the number of complications at the price of longer procedure duration. Radpad® scatter protection is a sterile, disposable bismuth-barium radiation shield drape that should be able to decrease the dose of operator radiation during diagnostic and interventional procedures. Such radiation shield has never been tested in a randomized study in humans. METHODS: Sixty consecutive patients undergoing coronary angiography by radial approach were randomized 1:1 to Radpad use versus no radiation shield protection. The sterile shield was placed around the area of right radial artery sheath insertion and extended medially to the patient trunk. All diagnostic procedures were performed by the same operator to reduce variability in radiation absorption. Radiation exposure was measured blindly using thermoluminescence dosimeters positioned at the operator's chest, left eye, left wrist, and thyroid. RESULTS: Despite similar fluoroscopy time (3.52 ± 2.71 min vs. 3.46 ± 2.77 min, P = 0.898) and total examination dose (50.5 ± 30.7 vs. 45.8 ± 18.0 Gycm(2), P = 0.231), the mean total radiation exposure to the operator was significantly lower when Radpad was utilized (282.8 ± 32.55 µSv vs. 367.8 ± 105.4 µSv, P < 0.0001) corresponding to a 23% total reduction. Moreover, mean radiation exposure was lower with Radpad utilization at all body locations ranging from 13 to 34% reduction. CONCLUSIONS: This first-in-men randomized trial demonstrates that Radpad significantly reduces occupational radiation exposure during coronary angiography performed through right radial artery access.


Assuntos
Angiografia Coronária/instrumentação , Doenças Profissionais/prevenção & controle , Exposição Ocupacional , Artéria Radial , Doses de Radiação , Lesões por Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Radiografia Intervencionista/instrumentação , Espalhamento de Radiação , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Equipamentos Descartáveis , Desenho de Equipamento , Feminino , Dosimetria Fotográfica , Fluoroscopia , Humanos , Itália , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Doenças Profissionais/etiologia , Imagens de Fantasmas , Lesões por Radiação/etiologia , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/métodos
4.
Catheter Cardiovasc Interv ; 78(6): 958-61, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21805566

RESUMO

With the diffusion of implantable ventricular assist pumps in heart failure patients refractory to treatments or ineligible to transplantation, acute aortic valve and device thrombosis is an unusual but potentially increasing complication. We report a novel application of Angiojet rheolytic thrombectomy for acute and massive thrombosis of the native aortic valve and of the left ventricular assist device in a heart failure patient. The technical execution and clinical experience with this technique is described.


Assuntos
Valva Aórtica , Insuficiência Cardíaca/terapia , Doenças das Valvas Cardíacas/terapia , Coração Auxiliar/efeitos adversos , Trombólise Mecânica , Trombose/terapia , Idoso , Catéteres , Doença Crônica , Desenho de Equipamento , Feminino , Doenças das Valvas Cardíacas/etiologia , Humanos , Trombólise Mecânica/instrumentação , Trombólise Mecânica/métodos , Desenho de Prótese , Terapia Trombolítica/efeitos adversos , Trombose/etiologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
J Interv Cardiol ; 24(1): 65-72, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20807305

RESUMO

BACKGROUND: Despite the increasing use of transradial techniques for cardiac percutaneous procedures, none of the strategies commonly utilized for hemostasis has been able to reduce the occurrence of radial artery occlusion (RAO). The aim of this study was to evaluate the occurrence of 24-hour RAO and the rate of bleeding of a novel hemostatic device for radial closure after percutaneous interventions, in adjunct to short-time compression. METHODS: Once the radial access was obtained, patients were randomized to 3 different strategies of radial closure: a short compression with the QuikClot® Interventional™ pad (Z-Medica Corporation, Wallingford, CT, USA) (15 minutes, group 1), a short compression (15 minutes, group 2), and a conventional prolonged compression (2 hours, group 3) both without QuikClot® utilization. RESULTS: Fifty patients in group 1, 20 in group 2, and 50 in group 3 were enrolled. The three groups were homogenous for baseline and procedural characteristics. None of patients in group 1 developed RAO, 1 (5%) occurred in group 2, and 5 (10%) in group 3 (P = 0.05). Active bleeding after compression removal occurred in 10 patients (20%) in group 1, 18 (90%) in group 2, and 1 (2%) in group 3 (P < 0.001). Among patients in group 1, at univariate analysis, the predictors of acute bleeding resulted in chronic therapy with clopidogrel (Odds Ratio 28.78, 95% Confidence Intervals 4.79-172.82, P < 0.001) and high levels of activated clotting time (ACT) at the time of sheath removal (OR 1.02, 95% CI 1.00-1.03, P = 0.009). At ROC analysis, the cutoff value of ACT for the risk of bleeding with a sensitivity of 80% and specificity of 75% was 287 seconds. CONCLUSIONS: Early sheet removal and short-time compression with QuikClot® Interventional™ can reduce the rate of RAO after diagnostic or interventional procedures especially in patients not on double antiplatelet therapy.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Arteriopatias Oclusivas/prevenção & controle , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Caulim/uso terapêutico , Artéria Radial/patologia , Angioplastia Coronária com Balão/métodos , Antidiarreicos/uso terapêutico , Testes de Coagulação Sanguínea , Intervalos de Confiança , Feminino , Hemorragia/etiologia , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Razão de Chances , Pressão , Artéria Radial/lesões , Fatores de Risco , Sensibilidade e Especificidade , Fatores de Tempo , Grau de Desobstrução Vascular
6.
Heart Vessels ; 26(2): 222-5, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21076923

RESUMO

Double-arterial coronary stent thrombosis in acute myocardial infarction (AMI) is an infrequent but severe complication, especially when the third main coronary artery is chronically occluded. The conus artery (CA) can serve as a major source of collateral when the left anterior descendent coronary artery (LAD) becomes obstructed. We report a case of a 48-year-old man presenting with AMI due to a very late double-arterial stent thrombosis (ST) following drug-eluting stent implantation and a chronic occlusion of LAD collateralized by a large anomalous CA, which provided for the entire vascularization of the coronary tree.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Oclusão Coronária/complicações , Anomalias dos Vasos Coronários/complicações , Infarto do Miocárdio/etiologia , Trombose/etiologia , Angioplastia Coronária com Balão/instrumentação , Doença Crônica , Circulação Colateral , Circulação Coronária , Oclusão Coronária/fisiopatologia , Oclusão Coronária/terapia , Anomalias dos Vasos Coronários/fisiopatologia , Anomalias dos Vasos Coronários/terapia , Stents Farmacológicos , Fibrinolíticos/uso terapêutico , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Inibidores da Agregação Plaquetária/uso terapêutico , Desenho de Prótese , Stents , Trombose/fisiopatologia , Resultado do Tratamento
7.
J Clin Med ; 10(6)2021 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-33808678

RESUMO

Among drug-eluting stents (DESs), the durable polymer everolimus-eluting stent (EES) and resolute zotarolimus-eluting stent (R-ZES) are widely used in clinical practice and have contributed to improve the outcomes of patients undergoing percutaneous coronary intervention (PCI). Few studies addressed their long-term comparative performance in patients with acute coronary syndrome (ACS). We aimed to investigate the 5 year comparative efficacy of EES and R-ZES in ACS. We queried ACTION-ACS, a large-scale database of ACS patients undergoing PCI. The treatment groups were analyzed using propensity score matching. The primary endpoint was a composite of mortality, myocardial infarction (MI), stroke, repeat PCI, and definite or probable stent thrombosis, which was addressed at the five-year follow-up. A total of 3497 matched patients were analyzed. Compared with R-ZES, a significant reduction in the primary endpoint at 5 years was observed in patients treated with EES (hazard ratio (HR) [95%CI] = 0.62 [0.54-0.71], p < 0.001). By landmark analysis, differences between the two devices emerged after the first year and were maintained thereafter. The individual endpoints of mortality (HR [95%CI] = 0.70 [0.58-0.84], p < 0.01), MI (HR [95%CI] = 0.55 [0.42-0.74], p < 0.001), and repeat PCI (HR [95%CI] = 0.65 [0.53-0.73], p < 0.001) were all significantly lower in the EES-treated patients. Stroke risk did not differ between EES and R-ZES. In ACS, a greater long-term clinical efficacy with EES vs. R-ZES was observed. This difference became significant after the first year of the ACS episode and persisted thereafter.

8.
Am Heart J ; 160(5): 973-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21095288

RESUMO

BACKGROUND: Although drug-eluting stents (DES) have reduced restenosis in a broad range of lesions, there is limited data, from relatively small studies, on the safety and efficacy of DES for isolated ostial left anterior descending (LAD) stenoses. In addition, in the setting of these high-risk lesions, there is the issue of the potential involvement of the left main (LM) bifurcation, requiring subsequent revascularization for a lesion involving this critical location. METHODS: Patients with a de novo isolated unprotected ostial LAD stenoses treated with DES were included. Evaluated end points were cardiac death, nonfatal myocardial infarction, overall target lesion revascularization (TLR), and the reintervention for a restenotic lesion located at the LM segment adjacent to the stent (TLR-LM). RESULTS: A total of 162 patients were included: 95 underwent focal ostial LAD stenting and 67 stenting from the distal LM into the LAD ostium. The 2-year Kaplan-Meier estimates of cardiac death, nonfatal myocardial infarction, overall TLR, and TLR-LM were 2.6%, 2.1%, 8.3%, and 4.7%, respectively. Overall TLR and TLR-LM rates were higher in the focal ostial LAD stenting group. There was a trend toward an independent increased risk of TLR associated with focal ostial stenting. In addition, final minimal luminal diameter trended to be independently associated with TLR. CONCLUSION: The present study showed that DES for isolated ostial LAD lesions is a feasible, safe, and effective treatment strategy. In addition, this study suggested the hypothesis that a default distal LM-LAD stenting, rather than focal ostial stenting, might provide more favorable outcomes. Nevertheless, larger specifically designed studies are needed.


Assuntos
Estenose Coronária/cirurgia , Stents Farmacológicos , Infarto do Miocárdio/epidemiologia , Causas de Morte , Angiografia Coronária , Reestenose Coronária/epidemiologia , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Eletrocardiografia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Prognóstico , Estudos Retrospectivos , Fatores de Tempo
9.
Catheter Cardiovasc Interv ; 75(4): 630-3, 2010 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-19937790

RESUMO

We report a case of successful transfemoral retrieval of a dislodged and mechanically distorted coronary stent from the right coronary artery in a middle age woman. The distorted stent was recovered via upsizing of her femoral arterial sheath and the use of a microsnare. The procedure was further complicated by significant right common femoral artery dissection, which was treated with percutaneous transluminal angioplasty from her contralateral femoral artery. The patient recovered well and was discharged the following day.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Estenose Coronária/terapia , Remoção de Dispositivo , Migração de Corpo Estranho/terapia , Stents , Adulto , Angioplastia com Balão , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/lesões , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Humanos , Doenças Vasculares Periféricas/diagnóstico por imagem , Doenças Vasculares Periféricas/etiologia , Doenças Vasculares Periféricas/terapia , Resultado do Tratamento
10.
J Interv Cardiol ; 23(4): 382-93, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20624203

RESUMO

BACKGROUND: Investigation of the correlation between bifurcation angles and outcomes is limited with discordant results. The aim of this study is to investigate left main (LM) and non-left main (N-LM) bifurcation angles and their modification after percutaneous coronary intervention (PCI). Measurement of all three angles adds to our understanding of bifurcation anatomy and the resultant effect of different stenting techniques. METHODS AND RESULTS: All three bifurcation angles were described according to the European Bifurcation Club definition: the A (proximal bifurcation angle), the B (distal bifurcation angle) and the C (main branch angle). Measurements were performed in 75 LM and 140 N-LM bifurcations. In LM bifurcations baseline mean values of C, A, and B were 151 degrees +/- 28 degrees, 131 degrees +/- 32 degrees, and 78 +/- 28 degrees, respectively. In bifurcations with 2 stents the B significantly decreased by a mean of 10 degrees (P = 0.003) and A increased by 10 degrees (P = 0.006). Crush stenting significantly decreased B (A - 14 degrees ; P = 0.020) and increased A (A + 21 degrees; P = 0.005), particularly non-true bifurcations. In N-LM bifurcations mean values for C, A, and B were 156 degrees +/- 19 degrees , 144 degrees +/- 22 degrees, and 60 degrees +/- 20 degrees, respectively. Similar to LM bifurcations, the B became narrower mainly at the expense of the A, which became wider. In both types of bifurcations the greatest variation in A and B was found following 2-stent techniques performed in T-shaped (> or =70 degrees) bifurcations. CONCLUSIONS: In both LM and N-LM bifurcations we found a significant difference in A and B pre- and post-PCI. This difference was driven by the 2-stent technique and was most evident with a baseline bifurcation angle > or =70 degrees. The Crush technique caused the largest angle variation post-procedure, particularly in non-true LM bifurcations.


Assuntos
Estenose Coronária/diagnóstico por imagem , Stents , Angioplastia Coronária com Balão , Angiografia Coronária , Estenose Coronária/terapia , Humanos , Estudos Retrospectivos
11.
Eur Heart J ; 29(17): 2108-15, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18565967

RESUMO

AIMS: To evaluate the occurrence of late and very late stent thrombosis (ST) following elective drug-eluting stent (DES) implantation in unprotected left main coronary artery (LMCA) stenosis in a large multicentre registry. METHODS AND RESULTS: All 731 consecutive patients who had sirolimus- or paclitaxel-eluting stent electively implanted in de novo lesions on unprotected LMCA in five centres were included. ST was defined according to Academic Research Consortium definitions. Four (0.5%) patients had a definite ST: three early (two acute and one subacute) and one late ST, no cases of very late definite ST were recorded. All patients survived from the event. Three patients had a probable ST. Therefore, 7/731 (0.95%) patients had a definite or a probable ST and all were on dual antiplatelet therapy at the time of the event. Possible (eight late and 12 very late) ST occurred in 20 (2.7%) patients. At 29.5 ± 13.7 months follow-up, a total of 45 (6.2%) patients had died; 31 (4.2%) of cardiac death. Ninety five (12.9%) patients had a target-vessel and 76 (10.4%) a target-lesion revascularization. Angiographic follow-up was performed in 548 patients (75%): restenosis occurred in 77 (14.1%) patients. CONCLUSION: Elective treatment of LMCA stenosis with DES appears safe with a 0.9% incidence of definite and probable ST at 29.5 ± 13.7 months.


Assuntos
Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Oclusão de Enxerto Vascular/etiologia , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Moduladores de Tubulina/administração & dosagem , Idoso , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica/métodos , Sistema de Registros , Resultado do Tratamento
13.
Am Heart J ; 153(3): 354-9, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17307411

RESUMO

BACKGROUND: Currently, little data are available on the management of drug-eluting stent (DES) restenosis. Drug resistance may play a role in its etiology. METHODS: We identified all cases of either sirolimus-eluting or paclitaxel-eluting stent restenosis treated with repeated DES implantation. The lesions were divided into those receiving the same DES as the one that restenosed and those treated with the alternative DES. The end points analyzed were target lesion revascularization (TLR) and angiographic restenosis. RESULTS: We included 201 lesions (174 patients); the same DES was implanted in 107 lesions and a different DES in 94 lesions. Angiographic follow-up of the retreatment was available in 69.7% of the lesions. Angiographic restenosis occurred in 26.4% (19) of cases treated with the same DES and 25.8% (17) of those treated with a different DES (P = 1.0). Target lesion revascularization occurred in 15.9% (17) and 16% (15) of lesions, respectively (P = 1.0). A multivariate analysis confirmed the lack of association between the treatment selected and TLR (OR 0.7, 95% CIs [0.29-1.67]; P = .42). A nonfocal pattern of restenosis remained associated with TLR and restenosis (OR 2.99, 95% CIs [1.24-7.24]; P = .015 and OR 3.6, 95% CIs [1.5-8.8]; P = .004, respectively). CONCLUSIONS: Repeated DES implantation for DES restenosis is feasible and safe. The TLR rate is acceptable, with no differences between implantation of the same or a different DES. The pattern of restenosis treated is an important predictor of outcomes.


Assuntos
Reestenose Coronária/tratamento farmacológico , Imunossupressores/administração & dosagem , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Stents , Idoso , Angiografia Coronária , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Desenho de Prótese , Retratamento
14.
Am J Cardiol ; 100(1): 41-4, 2007 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-17599438

RESUMO

Despite encouraging results from randomized trials, concerns exist about long-term results of sirolimus-eluting stent implantation. We sought to determine whether in-stent restenosis occurring >1 year ("late") after sirolimus-eluting stent implantation is a real clinical entity. We analyzed data on all sirolimus-eluting stents implanted in our institution before March 2003. During the study period 928 lesions in 433 patients were treated. Angiographic follow-up was performed in 306 patients (70.6%) with 679 lesions (73.2%). Angiography after 1 year was performed only in symptomatic patients. We considered restenosis "early" if it occurred during the first year and late if after 1 year. Late restenosis required demonstration of a widely patent stent at 6 to 9 months, with repeat angiography after 1 year demonstrating restenosis. Restenosis occurred in 160 lesions overall (23.5%). Of the 31 (4.6%) that were documented after 1 year, 13 were excluded from analysis due to absence of 6- to 9-month angiography; the remaining 18 (2.6%, 1.7 to 4.2) fulfilled our criteria for late restenosis (median time of documentation 607 days, interquartile range 511 to 923). In conclusion, late restenosis is an infrequent but real entity; its existence implies we should not discount the possibility of restenosis as the cause of symptoms that develop >1 year after sirolimus-eluting stent implantation.


Assuntos
Implante de Prótese Vascular , Reestenose Coronária/diagnóstico por imagem , Imunossupressores/administração & dosagem , Sirolimo/administração & dosagem , Stents , Idoso , Angiografia Coronária , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Fatores de Tempo
15.
Am J Cardiol ; 99(5): 593-8, 2007 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-17317355

RESUMO

Late loss is becoming an important end point to compare drug-eluting stents; however, little is known about its pattern of distribution. We analyzed the pattern of late loss distribution in sirolimus-eluting stents (SESs) and paclitaxel-eluting stents (PESs) in a consecutive cohort of patients. From a cohort of 529 patients treated with drug-eluting stents in 1 year, we selected all patients who underwent angiographic follow-up. Three hundred fifty-nine patients with 592 de novo lesions received SESs (286 lesions) or PESs (306 lesions). Late loss and binary angiographic restenosis were analyzed. Binary restenosis occurred in 56 lesions (19.6%) treated with SESs compared with 53 (17.3%) treated with PESs (p = 0.48). The 2 late loss distributions were skewed to the right and were not normally distributed (p <0.001 for SES, p = 0.003 for PES). Late loss was significantly lower in the SES group (p = 0.03), with a median value of 0.29 mm (interquartile range -0.09 to 0.66) versus 0.41 mm (-0.02 to 0.85) in the PES group. When analyzing only restenotic lesions, late loss had a normal distribution in the SES and PES groups (p = 0.96 and 0.44, respectively) and was similar in the 2 groups (1.75 +/- 0.51 vs 1.82 +/- 0.62, p = 0.48). When evaluating nonrestenotic lesions, late loss was also normally distributed in the 2 groups (p = 0.75 for SES, p = 0.73 for PES) but was significantly lower (p = 0.002) after SES implantation (0.14 +/- 0.39) than after PES implantation (0.27 +/- 0.44). In conclusion, SESs and PESs have a bimodal pattern of late loss distribution. The observed difference in late loss between SES and PES seems to be partly explained by the decrease in late loss after SES implantation in nonrestenotic lesions (where SES approaches "zero late loss"). Thus, late loss may not be a reliable marker of the true efficacy of these devices due to its complex and nongaussian distribution.


Assuntos
Endotélio Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/diagnóstico por imagem , Imunossupressores/administração & dosagem , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Stents , Moduladores de Tubulina/administração & dosagem , Idoso , Estudos de Coortes , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Feminino , Oclusão de Enxerto Vascular/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
16.
Chin Med J (Engl) ; 120(7): 545-51, 2007 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-17442200

RESUMO

BACKGROUND: The safety and efficacy of drug-eluting stents (DES) implantation in unprotected left main (LM) bifurcation lesions has yet to be determined. The aim of the present report was to evaluate the long-term outcome following implantation of DES in unprotected LM bifurcation lesions. METHODS: We identified 70 consecutive patients treated with DES in unprotected LM bifurcation lesions from April 2003 to January 2005. Of them, 42 patients were treated with sirolimus-eluting stent (SES) and 28 patients were treated with paclitaxel-eluting stent (PES). RESULTS: Stents to the left anterior descending and to the circumflex were implanted in 62 patients. During 1-year follow-up, 3 (4.3%) patients died of cardiac causes. One of them had myocardial infarction and adjudicated as possibly due to stent thrombosis. Angiographic follow-up was available in 80% of patients. The per lesion restenosis rate was 13.4% in the entire cohort, of which 10.7% occurred in lesions treated with SES and 16.1% in those treated with PES (P = 0.58). All restenosis was focal and occurred in the lesions treated with a stent with stent size to post-procedural reference vessel diameter ratio < 1.0 (17.6% vs 0, P = 0.04). The per patient target lesion revascularization rate at 1 year was 17.1%. One year survival free from major adverse cardiac events was 77.1%. CONCLUSIONS: Treatment of LM bifurcation lesions using DES is a safe and feasible way with a low one-year mortality. The need for revascularization in 17% of patients demands for improvement.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença das Coronárias/terapia , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Stents , Adulto , Idoso , Angiografia Coronária , Doença das Coronárias/mortalidade , Reestenose Coronária/prevenção & controle , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica
17.
J Am Coll Cardiol ; 45(7): 989-94, 2005 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-15808752

RESUMO

OBJECTIVES: The purpose of the present report was to evaluate clinical and angiographic outcomes of drug-eluting stent (DES) implantation in saphenous vein graft (SVG) lesions. BACKGROUND: The safety and efficacy of DES implantation for the treatment SVG lesions remains uncertain. METHODS: We evaluated in-hospital and six-month outcomes in 61 consecutive patients treated with DES in SVG lesions from March 2002 to March 2004 (DES group), as compared to 89 consecutive patients treated with bare-metal stents (BMS) in the 24 months immediately before the introduction of DES (BMS group). Major adverse cardiac events (MACE) including death, myocardial infarction, target lesion revascularization (TLR), and target vessel revascularization (TVR) were recorded in-hospital and at six-month follow-up. RESULTS: The rate of in-hospital MACE was similar between the two groups (6.6% vs. 5.6%, p = 1.0). Cumulative MACE at six months was 11.5% in the DES group and 28.1% in the BMS group (p = 0.02). The DES group had a significantly lower incidence of in-segment restenosis (10.0% vs. 26.7%, p = 0.03), TLR (3.3% vs. 19.8%, p = 0.003), and TVR (4.9% vs. 23.1%, p = 0.003). By Cox regression analysis, diabetes (hazard ratio [HR]: 3.03; 95% confidence interval [CI]: 1.33 to 6.90; p = 0.008), usage of BMS (HR: 2.53; 95% CI: 1.07 to 5.97; p = 0.03), and age of SVG (HR: 1.10; 95% CI: 1.02 to 1.19; p = 0.02) were identified as predictors of MACE at six-month follow-up. CONCLUSIONS: Compared to BMS implantation, DES implantation in SVG lesions appears safe with favorable and improved mid-term outcomes.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária/terapia , Oclusão de Enxerto Vascular/terapia , Veia Safena/transplante , Stents , Idoso , Estudos de Casos e Controles , China/epidemiologia , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/mortalidade , Hospitalização , Humanos , Imunossupressores/administração & dosagem , Itália/epidemiologia , Masculino , Paclitaxel/administração & dosagem , Complicações Pós-Operatórias/mortalidade , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Sirolimo/administração & dosagem , Análise de Sobrevida , Resultado do Tratamento
18.
J Am Coll Cardiol ; 46(4): 613-20, 2005 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-16098424

RESUMO

OBJECTIVES: The purpose of this research was to evaluate the long-term outcomes after implantation of drug-eluting stents (DES) in bifurcation lesions with the "crush" technique. BACKGROUND: The long-term outcome of "crush" stenting technique has yet to be determined. METHODS: We identified 181 consecutive patients who were treated with DES with the "crush" stent technique from April 2002 to April 2004. Based on the usage of final kissing balloon post-dilation (FKB), the patients were divided into an FKB group (n = 116) and a non-FKB group (n = 65). RESULTS: Clinical follow-up at nine months was available in all patients, and angiographic follow-up in 80% of patients. Three cases (1.7%) of intraprocedural stent thrombosis and five (2.8%) cases of postprocedural stent thrombosis occurred. Restenosis rate of the main branch in the entire cohort lesions was 11.5%. Restenosis rate of the side branch was lower in the FKB group than that in the non-FKB group (11.1% vs. 37.9%, p < 0.001). The target lesion revascularization (TLR) rate for all patients was 14.9%. The lack of FKB was a predictor for TLR (hazard ratio [HR] 4.17; 95% confidence interval [CI] 1.30 to 14.3, p = 0.02). Diabetes was also a predictor for TLR (HR 1.79; 95% CI 1.14 to 2.80, p = 0.01). Premature discontinuation of dual antiplatelet therapy (odds ratio [OR] 16.8; 95% CI 1.31 to 159.5, p = 0.03) and age (OR 1.10; 95% CI 1.00 to 1.21, p = 0.048) was associated with the occurrence of postprocedural stent thrombosis. CONCLUSIONS: Compared to the absence of FKB, the "crush" stenting technique with FKB appears to be associated with more favorable long-term outcomes. When utilizing the "crush" stenting technique, FKB is mandatory.


Assuntos
Angioplastia Coronária com Balão/métodos , Implante de Prótese Vascular/métodos , Estenose Coronária/terapia , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Stents , Resultado do Tratamento , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
19.
J Am Coll Cardiol ; 45(10): 1570-3, 2005 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-15893168

RESUMO

OBJECTIVES: We sought to determine the safety and efficacy of using multiple overlapping drug-eluting stents (DES) in patients with diffuse left anterior descending coronary artery (LAD) disease. BACKGROUND: Diffuse LAD disease represents a therapeutic challenge. Results after coronary artery bypass surgery are suboptimal, whereas the use of bare metal stents is limited by high rates of restenosis. The introduction of DES prompted treatment of long diffuse disease with multiple overlapping stents. METHODS: All consecutive patients with de novo diffuse LAD disease treated with more than 60-mm long DES from April 2002 to March 2004 were analyzed. RESULTS: The study population consisted of 66 patients. Thirty-nine patients were treated with sirolimus-eluting stents (SES), average length 84 +/- 22 mm, and 27 patients with paclitaxel-eluting stents (PES), average length 74 +/- 14 mm. The number of stents implanted per patient was 2.8 +/- 0.7, whereas the mean total stent length for the LAD treatment was 80 +/- 20 mm. Angiographic as well as procedural success was achieved in 95% of cases. Eleven (16.6%) patients had in-hospital non-Q-wave myocardial infarction (five SES and six PES), and one patient developed intraprocedural stent thrombosis. All patients had clinical follow-up, and 52 patients (79%) had an angiographic follow-up at six months. Hierarchical major adverse cardiac event rate was 15% (7.5% for SES and 7.5% for PES). No patients died, one patient had non-Q-wave myocardial infarction (non-index vessel), and 10 patients (15%) underwent target vessel revascularization. CONCLUSIONS: The implantation of multiple overlapping DES in patients with a diffusely diseased LAD is relatively safe and associated with good midterm clinical outcomes.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Stents , Administração Tópica , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Resultado do Tratamento
20.
Int J Cardiol ; 108(3): 406-7, 2006 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-16520130

RESUMO

Thienopyridines and aspirin are beneficial in patients undergoing bare-metal stent implantation, and aspirin and clopidogrel treatment have also been proved effective after drug-eluting stent (DES) implantation. However, despite the common substitution of clopidogrel with ticlopidine because of cost or patient intolerance, there are no data on the comparison of ticlopidine vs. clopidogrel after DES implantation. We hereby compare ticlopidine vs. clopidogrel after paclitaxel-eluting stent implantation in subjects enrolled in the prospective multicenter Taxus in Real-life Usage Evaluation (TRUE) Study. Across the 505 analyzed patients (112 treated with ticlopidine and 393 with clopidogrel), similar rates of early and mid-term (7 months) adverse thrombotic events were found with either antiplatelet regimen, with the notable exception of 2 cases of late stent thrombosis in patients who had prematurely withdrawn ticlopidine treatment just 3 months after the procedure. These findings thus support the overall safety and effectiveness of ticlopidine after DES implantation, and also confirm the increased risk of late thrombosis when premature withdrawal of thienopyridines occurs.


Assuntos
Aspirina/uso terapêutico , Doença das Coronárias/terapia , Paclitaxel/administração & dosagem , Inibidores da Agregação Plaquetária/uso terapêutico , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Clopidogrel , Reestenose Coronária/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA