Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 174
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmology ; 131(3): 383-392, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38149945

RESUMO

PURPOSE: To review the published literature evaluating the visual and refractive outcomes and rotational stability of eyes implanted with toric monofocal intraocular lenses (IOLs) for the correction of keratometric astigmatism during cataract surgery and to compare those outcomes with outcomes of eyes implanted with nontoric monofocal IOLs and other astigmatism management methods performed during cataract surgery. This assessment was restricted to the toric IOLs available in the United States. METHODS: A literature search of English-language publications in the PubMed database was last conducted in July 2022. The search identified 906 potentially relevant citations, and after review of the abstracts, 63 were selected for full-text review. Twenty-one studies ultimately were determined to be relevant to the assessment criteria and were selected for inclusion. The panel methodologist assigned each a level of evidence rating; 12 studies were rated level I and 9 studies were rated level II. RESULTS: Eyes implanted with toric IOLs showed excellent postoperative uncorrected distance visual acuity (UCDVA), reduction of postoperative refractive astigmatism, and good rotational stability. Uncorrected distance visual acuity was better and postoperative cylinder was lower with toric IOLs, regardless of manufacturer, when compared with nontoric monofocal IOLs. Correcting pre-existing astigmatism with toric IOLs was more effective and predictable than using corneal relaxing incisions (CRIs), especially in the presence of higher magnitudes of astigmatism. CONCLUSIONS: Toric monofocal IOLs are effective in neutralizing pre-existing corneal astigmatism at the time of cataract surgery and result in better UCDVA and significant reductions in postoperative refractive astigmatism compared with nontoric monofocal IOLs. Toric IOLs result in better astigmatic correction than CRIs, particularly at high magnitudes of astigmatism. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Oftalmologia , Facoemulsificação , Humanos , Astigmatismo/cirurgia , Implante de Lente Intraocular , Desenho de Prótese , Refração Ocular
2.
Exp Eye Res ; 239: 109794, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38237715

RESUMO

The purpose of this study was to evaluate transforming growth factor beta (TGFß) isoform localization in rabbit corneas with spontaneous persistent epithelial defects (PEDs) after photorefractive keratectomy (PRK). Four cryofixed corneas from a previously reported series of PEDs in rabbits that had PRK were evaluated with triplex immunohistochemistry (IHC) for TGFß3, myofibroblast marker alpha-smooth muscle actin (α-SMA) and mesenchymal marker vimentin. One cornea had sufficient remaining tissue for triplex IHC for TGFß1, TGFß2, or TGFß3 (each with α-SMA and vimentin) using isoform-specific antibodies. All three TGFß isoforms were detected in the subepithelial stroma at and surrounding the PED. Some of each TGFß isoform co-localized with α-SMA of myofibroblasts, which could be TGFß isoform autocrine production by myofibroblasts or TGFß-1, -2, and -3 binding to these myofibroblasts.


Assuntos
Ceratectomia Fotorrefrativa , Animais , Coelhos , Vimentina/metabolismo , Fator de Crescimento Transformador beta/metabolismo , Substância Própria/metabolismo , Córnea/metabolismo , Isoformas de Proteínas/metabolismo , Actinas/metabolismo
3.
Ophthalmology ; 130(1): 87-98, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36207168

RESUMO

OBJECTIVE: To evaluate current best practices for postoperative photorefractive keratectomy (PRK) pain control. METHODS: Literature searches in the PubMed database were last conducted in October 2021 and were restricted to publications in English. This search identified 219 citations, of which 84 were reviewed in full text for their relevance to the scope of this assessment. Fifty-one articles met the criteria for inclusion; 16 studies were rated level I, 33 studies were rated level II, and 2 studies were rated level III. RESULTS: Systemic opioid and nonsteroidal anti-inflammatory drugs (NSAIDs); topical NSAIDs; postoperative cold patches; bandage soft contact lenses (BCLs), notably senofilcon A contact lenses; and topical anesthetics were demonstrated to offer significantly better pain control than comparison treatments. Some other commonly reported pain mitigation interventions such as systemic gabapentinoids, chilled intraoperative balanced salt solution (BSS) irrigation, cycloplegia, and specific surface ablation technique strategies offered limited improvement in pain control over control treatments. CONCLUSIONS: Systemic NSAIDs and opioid medications, topical NSAIDs, cold patches, BCLs, and topical anesthetics have been shown to provide improved pain control over alternative strategies and allow PRK-associated pain to be more tolerable for patients.


Assuntos
Lentes de Contato Hidrofílicas , Oftalmologia , Ceratectomia Fotorrefrativa , Humanos , Anestésicos Locais , Analgésicos Opioides/uso terapêutico , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle , Anti-Inflamatórios não Esteroides/uso terapêutico , Lasers de Excimer/uso terapêutico
4.
Ophthalmology ; 129(8): 946-954, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35570159

RESUMO

PURPOSE: To evaluate refractive outcomes, safety, and cost-effectiveness of femtosecond laser-assisted cataract surgery (FLACS) compared with phacoemulsification cataract surgery (PCS). METHODS: A PubMed search of FLACS was conducted in August 2020. A total of 727 abstracts were reviewed and 33 were selected for full-text review. Twelve articles met inclusion criteria and were included in this assessment. The panel methodologist assigned a level of evidence rating of I to all 12 studies. RESULTS: No significant differences were found in mean uncorrected distance visual acuity, best-corrected distance visual acuity, or the percentage of eyes within ± 0.5 and ± 1 diopter of intended refractive target between FLACS and PCS. Intraoperative and postoperative complication rates were similar between the 2 groups, and most studies showed no difference in endothelial cell loss between FLACS and PCS at various time points between 1 and 6 months. In large randomized controlled studies in the United Kingdom and France, FLACS was less cost-effective than PCS. CONCLUSIONS: Both FLACS and PCS have similar excellent safety and refractive outcomes. At this time, one technique is not superior to the other, but economic analyses performed in some populations have shown that FLACS is less cost-effective.


Assuntos
Extração de Catarata , Catarata , Terapia a Laser , Oftalmologia , Facoemulsificação , Extração de Catarata/métodos , Humanos , Terapia a Laser/métodos , Lasers , Facoemulsificação/métodos
5.
Exp Eye Res ; 216: 108940, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35074340

RESUMO

The purpose of this study was to examine the effect of topical and/or oral angiotensin converting enzyme II inhibitor and TGF-beta signaling blocker losartan on corneal stromal fibrosis that developed in rabbit corneas after Descemetorhexis removal of central Descemet's membrane and corneal endothelium. Twenty-eight New Zealand white rabbits were included and either had 8 mm central Descemetorhexis or sham control surgery without Descemetorhexis in one eye. Groups of 4 eyes without Descemetorhexis were treated for one month with no medications, topical losartan or oral losartan. Groups of 4 eyes with Descemetorhexis were treated with topical and oral vehicle, topical losartan, oral losartan, or both topical losartan and oral losartan for one month. Standardized slit lamp photos were obtained with central opacity intensity measured with ImageJ. The posterior fibrotic zone of corneas was measured on immunohistochemistry for alpha-smooth muscle actin (SMA) and keratocan using QuPath analysis. Collagen type IV expression in the posterior cornea was quantitated with ImageJ and duplex immunohistochemistry for collagen type IV and TGF beta-1. After Descemetorhexis, topical, but not oral, losartan decreased the intensity of central stromal opacity, reduced peripheral corneal scarring, and decreased alpha-smooth muscle actin myofibroblast fibrosis area compared to corneas that had Descemetorhexis and treatment with vehicles alone. Topical losartan decreased posterior stromal cellular, non-Descemet's membrane, collagen type IV production, that is likely stimulated by TGF beta as part of a negative regulatory feedback mechanism, compared to vehicle treatment at one month after Descemetorhexis. Topical losartan is likely to be effective in reducing corneal scarring fibrosis produced by traumatic injury, microbial infection, and some corneal diseases and surgeries.


Assuntos
Bloqueadores do Receptor Tipo 1 de Angiotensina II/administração & dosagem , Cicatriz/tratamento farmacológico , Colágeno Tipo IV/metabolismo , Doenças da Córnea/tratamento farmacológico , Substância Própria/patologia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Losartan/administração & dosagem , Actinas/metabolismo , Administração Oftálmica , Animais , Cicatriz/metabolismo , Doenças da Córnea/metabolismo , Substância Própria/metabolismo , Feminino , Fibrose/prevenção & controle , Imuno-Histoquímica , Soluções Oftálmicas , Proteoglicanas/metabolismo , Coelhos , Microscopia com Lâmpada de Fenda
6.
Ophthalmology ; 128(5): 781-792, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33500124

RESUMO

PURPOSE: To review the literature to evaluate the outcomes of intraocular lens (IOL) power calculation in eyes with a history of myopic LASIK or photorefractive keratectomy (PRK). METHODS: Literature searches were conducted in the PubMed database in January 2020. Separate searches relevant to cataract surgery outcomes and corneal refractive surgery returned 1169 and 162 relevant citations, respectively, and the full text of 24 was reviewed. Eleven studies met the inclusion criteria for this assessment; all were assigned a level III rating of evidence by the panel methodologist. RESULTS: When automated keratometry was used with a theoretical formula designed for eyes without previous laser vision correction, the mean prediction error (MPE) was universally positive (hyperopic), the mean absolute errors (MAEs) and median absolute errors (MedAEs) were relatively high (0.72-1.9 diopters [D] and 0.65-1.73 D, respectively), and a low (8%-40%) proportion of eyes were within 0.5 D of target spherical equivalent (SE). Formulas developed specifically for this population requiring both prerefractive surgery keratometry and manifest refraction (i.e., clinical history, corneal bypass, and Feiz-Mannis) produced a proportion of eyes within 0.5 D of target SE between 26% and 44%. Formulas requiring only preoperative keratometry or no history at all had lower MAEs (0.42-0.94 D) and MedAEs (0.30-0.81 D) and higher (30%-68%) proportions within 0.5 D of target SE. Strategies that averaged several methods yielded the lowest reported MedAEs (0.31-0.35 D) and highest (66%-68%) proportions within 0.5 D of target SE. Even after using the best-known methods, refractive outcomes were less accurate in eyes that had previous excimer laser surgery for myopia compared with those that did not have it. CONCLUSIONS: Calculation methods requiring both prerefractive surgery keratometry and manifest refraction are no longer considered the gold standard. Refractive outcomes of cataract surgery in eyes that had previous excimer laser surgery are less accurate than in eyes that did not. Patients should be advised of this refractive limitation when considering cataract surgery in the setting of previous corneal refractive surgery. Conclusions are limited by the small sample sizes and retrospective nature of nearly all existing literature in this domain.


Assuntos
Biometria/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lentes Intraoculares , Miopia/cirurgia , Óptica e Fotônica , Ceratectomia Fotorrefrativa/métodos , Avaliação da Tecnologia Biomédica , Academias e Institutos , Humanos , Implante de Lente Intraocular , Miopia/fisiopatologia , Oftalmologia/organização & administração , Facoemulsificação , Refração Ocular/fisiologia , Estudos Retrospectivos , Estados Unidos
7.
Ophthalmology ; 128(10): 1469-1482, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33741376

RESUMO

PURPOSE: To review the published literature assessing the efficacy and safety of presbyopia-correcting intraocular lenses (IOLs) for the treatment of presbyopia after cataract removal. METHODS: Literature searches were undertaken in January 2018 and September 2020 in the PubMed, Medline, and Cochrane Library databases. This yielded 761 articles, of which 34 met the criteria for inclusion in this assessment and were assigned a level of evidence rating by the panel methodologist. Thirteen studies were rated level I and 21 studies were rated level II. RESULTS: Presbyopia-correcting lenses were effective at improving distance and near visual acuity after cataract surgery. Near acuity at different focal lengths was related directly to the effective add power of multifocal and extended depth-of-focus (EDOF) IOLs. Most multifocal and EDOF lenses that were compared with a control monofocal lens demonstrated that patient-reported spectacle independence was superior to the monofocal lens. All patients who had multifocal and EDOF lenses implanted showed decreased contrast sensitivity and reported more visual phenomena as compared with control participants who received monofocal lenses. CONCLUSIONS: Presbyopia-correcting lenses improve uncorrected near and distance visual acuity and decrease spectacle dependence after cataract surgery. Mesopic contrast sensitivity is decreased compared with monofocal lenses, and patient-reported visual phenomena are more likely in patients receiving multifocal or EDOF lenses.


Assuntos
Academias e Institutos , Acomodação Ocular/fisiologia , Implante de Lente Intraocular/métodos , Lentes Intraoculares Multifocais , Oftalmologia , Presbiopia/cirurgia , Refração Ocular/fisiologia , Percepção de Profundidade , Humanos , Satisfação do Paciente , Presbiopia/fisiopatologia , Desenho de Prótese , Estados Unidos , Acuidade Visual
8.
Exp Eye Res ; 204: 108458, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33493475

RESUMO

Peripheral ulcerative keratitis (PUK) is a progressive peripheral thinning of the corneal stroma caused by proinflammatory mediators' release from corneal limbal vasculitis. The clinical presentation is an epithelial defect with a crescent-shaped stromal inflammation. Its exact pathophysiologic mechanisms of PUK remain partially understood, but the overall understanding of the fundamental processes that mediate and effect corneal immunity has continued to expand over the past 25 years. The unique anatomical and physiological characteristics of the periphery in relation to collagen bundles and peripheral corneal vascular arch contribute to the occurrence of this type of ulcer in this region, in addition to the concentration of complement and immunoglobulins. There is a relevant participation of the adjacent conjunctiva. Both cell-mediated immunity and humoral immunity are implicated in the pathogenesis of PUK, and the postulated mechanisms are autoimmune reactions to corneal antigens, deposition of circulating immune complexes and hypersensitivity reactions to foreign antigens. These immunocomplexes are deposited in limbic vessels resulting in the activation of the classical pathway of the complement system and, consequently, in the chemotaxis of inflammatory cells and in the release of several pro-inflammatory cytokines, which allow the production and release of matrix metalloproteinases. The release of inflammatory cytokines by infiltrating cells may induce keratocyte activation, which could then generate more release of a variety of cytokines, such as the neutrophil calgranulin C, thus facilitating an autoimmune response to the protein and precipitating an antibody- and cell-mediated hyperimmune reaction in the peripheral cornea.


Assuntos
Úlcera da Córnea/imunologia , Imunidade Celular/fisiologia , Imunidade Humoral/fisiologia , Autoimunidade , Substância Própria/patologia , Úlcera da Córnea/diagnóstico , Úlcera da Córnea/fisiopatologia , Humanos , Limbo da Córnea/patologia , Vasculite/patologia
9.
Exp Eye Res ; 202: 108355, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33171194

RESUMO

Over the past 20 years, corneal crosslinking (CXL) has been used by surgeons to halt progression in eyes with keratoconus. We reviewed the literature regarding the mechanism of action of CXL, the role of each of its components the strong biologic reaction, and their effects on cell interaction, proteins involved, wound healing, and cytotoxic reaction. CXL surgery involves a photochemical response in which ultraviolet light at a given wavelength and riboflavin participate. The combination of irradiation with UVA light and riboflavin leads to an intense process of apoptosis of keratocytes in the anterior stroma. Differences in light irradiation, as well as the importance of riboflavin and its vehicle, were also detailed. The surgery creates additional chemical bonds between the amino terminals of the collagen side chains and the proteoglycans of the extracellular matrix. A photosensitization reaction catalyzed by riboflavin classically involves the production of singlet oxygen. Microstructure studies show changes in the size of the fibril and potentially in the interfibrillar space, that the most significant changes related to the stiffening effect of CXL occur in the anterior third of the cornea and that short irradiation times, especially below 5 min, may not have the same biological effect. Changes in the riboflavin vehicle, with the incorporation of Hydroxypropyl methylcellulose as a carrier, can lead to faster diffusion and a more intense photochemical reaction. These are findings that can impact the optimal adjustment of irradiation time according to the riboflavin (and its carrier) used. Many studies have suggested that CXL is safe and effective in the standard and accelerated protocols that have been used by surgeons. After the initial depletion of anterior keratocytes, keratocyte density seems to return to average 6-12 months after surgery when corneas are examined with the confocal microscope.


Assuntos
Colágeno/farmacologia , Substância Própria/ultraestrutura , Reagentes de Ligações Cruzadas/farmacologia , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Riboflavina/farmacologia , Humanos , Ceratocone/diagnóstico , Microscopia Confocal , Microscopia Eletrônica de Transmissão , Fármacos Fotossensibilizantes/farmacologia , Raios Ultravioleta
10.
Exp Eye Res ; 213: 108803, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34736886

RESUMO

The purpose of this investigation was to study Descemet's membrane and corneal endothelial regeneration, myofibroblast generation and disappearance, and TGF beta-1 localization after Descemet's membrane-endothelial excision (Descemetorhexis) in rabbits. Thirty-six rabbits had 8 mm Descemetorhexis and standardized slit lamp photos at 1, 2 and 4 days, 1, 2 and 4 weeks, and 2, 4 and 6 months, as well as multiplex IHC for stromal cell markers keratocan, vimentin, and alpha-smooth muscle actin (SMA); basement membrane (BM) components perlecan, nidogen-1, laminin alpha-5, and collagen type IV; and corneal endothelial marker Na,K-ATPase ß1, and TGF beta-1, with ImageJ quantitation. Stromal transparency increased from the periphery beginning at two months after injury and progressed into the central cornea by six months. At six months, central transparency was primarily limited by persistent mid-stromal neovascularization. Stromal myofibroblast zone thickness in the posterior stroma peaked at one month after injury, and then progressively decreased until to six months when few myofibroblasts remained. The regeneration of a laminin alpha-5 and nidogen-1 Descemet's membrane "railroad track" structure was accompanied by corneal endothelial closure and stromal cell production of BM components in corneas from four to six months after injury. TGF beta-1 deposition at the posterior corneal surface from the aqueous humor peaked at one day after Descemetorhexis and diminished even before regeneration of the endothelium and Descemet's membrane. This decrease was associated with collagen type IV protein production by corneal fibroblasts, and possibly myofibroblasts, in the posterior stroma. Descemet's membrane and the corneal endothelium regenerated in the rabbit cornea by six months after eight mm Descemetorhexis. Real-time quantitative RT-PCR experiments in vitro with marker-verified rabbit corneal cells found that 5 ng/ml or 10 ng/ml TGF beta-1 upregulated col4a1 or col4a2 mRNA expression after 6 h or 12 h of exposure in corneal fibroblasts, but not in myofibroblasts. Stromal cells produced large amounts of collagen type IV that likely decreased TGF beta-1 penetration into the stroma and facilitated the resolution of myofibroblast-generated fibrosis.


Assuntos
Córnea/patologia , Lâmina Limitante Posterior/lesões , Endotélio Corneano/fisiologia , Regeneração/fisiologia , Cicatrização/fisiologia , Animais , Biomarcadores/metabolismo , Córnea/metabolismo , Ceratócitos da Córnea/metabolismo , Substância Própria/metabolismo , Proteínas do Olho/metabolismo , Feminino , Fibrose , Imuno-Histoquímica , Coelhos , Microscopia com Lâmpada de Fenda , Fator de Crescimento Transformador beta1/metabolismo
11.
Exp Eye Res ; 202: 108325, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33263285

RESUMO

The purpose of this study was to investigate the expression and localization of transforming growth factor (TGF) ß1 and TGFß2 in rabbit corneas that healed with and without stromal fibrosis, and to further study defective perlecan incorporation in the epithelial basement membrane (EBM) in corneas with scarring fibrosis. A total of 120 female rabbits had no surgery, -4.5D PRK, or -9D PRK. Immunohistochemistry (IHC) was performed at time points from unwounded to eight weeks after surgery, with four corneas at each time point in each group. Multiplex IHC was performed for TGFß1 or TGFß2, with Image-J quantitation, and keratocan, vimentin, alpha-smooth muscle actin (SMA), perlecan, laminin-alpha 5, nidogen-1 or CD11b. Corneas at the four-week peak for myofibroblast and fibrosis development were evaluated using Imaris 3D analysis. Delayed regeneration of both an apical epithelial growth factor barrier and EBM barrier function, including defective EBM perlecan incorporation, was greater in high injury -9D PRK corneas compared to -4.5D PRK corneas without fibrosis. Defective apical epithelial growth factor barrier and EBM allowed epithelial and tear TGFß1 and tear TGFß2 to enter the corneal stroma to drive myofibroblast generation in the anterior stroma from vimentin-positive corneal fibroblasts, and likely fibrocytes. Vimentin-positive cells and unidentified vimentin-negative, CD11b-negative cells also produce TGFß1 and/or TGFß2 in the stroma in some corneas. TGFß1 and TGFß2 were at higher levels in the anterior stroma in the weeks preceding myofibroblast development in the -9D group. All -9D corneas (beginning two to three weeks after surgery), and four -4.5D PRK corneas developed significant SMA + myofibroblasts and stromal fibrosis. Both the apical epithelial growth factor barrier and/or EBM barrier functions tended to regenerate weeks earlier in -4.5D PRK corneas without fibrosis, compared to -4.5D or -9D PRK corneas with fibrosis. SMA-positive myofibroblasts were markedly reduced in most corneas by eight weeks after surgery. The apical epithelial growth factor barrier and EBM barrier limit TGFß1 and TGFß2 entry into the corneal stroma to modulate corneal fibroblast and myofibroblast development associated with scarring stromal fibrosis. Delayed regeneration of these barriers in corneas with more severe injuries promotes myofibroblast development, prolongs myofibroblast viability and triggers stromal scarring fibrosis.


Assuntos
Membrana Basal/fisiologia , Córnea/metabolismo , Substância Própria/patologia , Epitélio Corneano/fisiologia , Regeneração/fisiologia , Fator de Crescimento Transformador beta1/metabolismo , Fator de Crescimento Transformador beta2/metabolismo , Animais , Opacidade da Córnea/metabolismo , Opacidade da Córnea/patologia , Substância Própria/metabolismo , Feminino , Fibrose/metabolismo , Fibrose/patologia , Proteínas de Membrana/metabolismo , Microscopia Confocal , Coelhos
12.
Exp Eye Res ; 200: 108243, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32926895

RESUMO

The cornea is a highly innervated tissue, exhibiting a complex nerve architecture, distribution, and structural organization. Significant contributions over the years have allowed us to come to the current understanding about the corneal nerves. Mechanical or chemical trauma, infections, surgical wounds, ocular or systemic comorbidities, can induce corneal neuroplastic changes. Consequently, a cascade of events involving the corneal wound healing, trophic functions, neural circuits, and the lacrimal products may interfere in the corneal homeostasis. Nerve physiology drew the attention of investigators due to the popularization of modern laser refractive surgery and the perception of the destructive potential of the excimer laser to the corneal nerve population. Nerve fiber loss can lead to symptoms that may impact the patient's quality of life, and impair the best-corrected vision, leading to patient and physician dissatisfaction. Therefore, there is a need to better understand preoperative signs of corneal nerve dysfunction, the postoperative mechanisms of nerve degeneration and recovery, aiming to achieve the most efficient way of treating nerve disorders related to diseases and refractive surgery.


Assuntos
Córnea/inervação , Lesões da Córnea/diagnóstico , Regeneração Nervosa , Nervo Oftálmico/diagnóstico por imagem , Cicatrização/fisiologia , Lesões da Córnea/fisiopatologia , Humanos , Fibras Nervosas/patologia , Nervo Oftálmico/fisiopatologia
13.
Ophthalmology ; 125(12): 1862-1871, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30055838

RESUMO

PURPOSE: To determine optimal objective, machine-derived variables and variable combinations from Scheimpflug and spectral-domain (SD) OCT imaging to distinguish the clinically unaffected eye in patients with asymmetric keratoconus (AKC) from a normal control population. DESIGN: Retrospective case-control study. PARTICIPANTS: Thirty clinically unaffected eyes with no physical findings on slit-lamp examination, no definitive abnormalities on corneal imaging, and corrected distance acuity of 20/20 or better from 30 patients with highly AKC eyes and 60 eyes from 60 normal control patients who had undergone uneventful LASIK with at least 2 years of stable follow-up (controls). METHODS: Scheimpflug and SD OCT imaging were obtained in all eyes, and receiver operating characteristic (ROC) curves were generated to determine area under the curve (AUC), sensitivity, and specificity for each machine-derived variable and variable combination. MAIN OUTCOME MEASURES: Distinguishing AKC eyes from controls as determined by AUC, sensitivity, and specificity. RESULTS: No individual machine-derived metric from Scheimpflug or SD OCT technology yielded an AUC higher than 0.75. Combining 5 Scheimpflug metrics (index height decentration [IHD], index vertical asymmetry [IVA], pachymetry apex, inferior-superior value, and Ambrosio's Relational Thickness Maximum [ARTmax]) yielded the best Scheimpflug results (AUC 0.86, sensitivity 83%, specificity 83%). Combining 11 SD OCT thickness metrics (minimum-median, temporal outer, superior nasal outer, minimum, epithelium minimum-maximum, epithelial standard deviation, superior inner, superior outer, superior temporal outer, superior nasal inner, central) yielded the best SD OCT results (AUC 0.96, sensitivity 89%, specificity 89%). Combining 13 total Scheimpflug/SD OCT metrics yielded the best results overall (AUC 1.0, sensitivity 100%, specificity 100%). The most impactful variables in combined models included epithelial thickness variability and total focal corneal thickness variability from SD OCT and anterior curvature and topometric indices from Scheimpflug technology. No posterior corneal metrics were impactful in modeling. CONCLUSIONS: Individual machine-derived metrics from Scheimpflug and SD OCT imaging poorly distinguished normal eyes from minimally affected eyes from patients with highly AKC. Combined SD OCT metrics performed better than combined Scheimpflug metrics. Combining anterior curvature and asymmetry indices from Scheimpflug with regional total thickness and epithelial thickness variability metrics from SD OCT clearly distinguished the 2 populations. Posterior corneal indices were not useful in distinguishing populations.


Assuntos
Córnea/patologia , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Área Sob a Curva , Estudos de Casos e Controles , Paquimetria Corneana , Feminino , Humanos , Ceratocone/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Adulto Jovem
14.
Exp Eye Res ; 172: 30-35, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29596850

RESUMO

This study was performed to determine whether cells in the posterior stroma undergo apoptosis in response to endothelial cell injury and to determine whether basement membrane component nidogen-1 was present in the cornea. New Zealand White rabbits had an olive tip cannula inserted into the anterior chamber to mechanically injure corneal endothelial cells over an 8 mm diameter area of central cornea with minimal injury to Descemet's membrane. At 1 h (6 rabbits) and 4 h (6 rabbits) after injury, three corneas at each time point were cryopreserved in OCT for terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay and immunohistochemistry (IHC) for vimentin and nidogen-1, and three corneas at each time point were fixed for transmission electron microscopy (TEM). Uninjured corneas were controls. Stromal cells over approximately the posterior 25% of the stroma overlying to the site of corneal endothelial injury underwent apoptosis detected by the TUNEL assay. Many of these apoptotic cells were vimentin+, suggesting they were likely keratocytes or corneal fibroblasts. Stromal cells peripheral to the site of endothelial injury and more anterior stromal cells overlying the site of endothelial injury did not undergo apoptosis. Stromal cell death was confirmed to be apoptosis by TEM. No apoptosis of stromal cells was detected in control, uninjured corneas. Nidogen-1 was detected in the stroma of unwounded corneas, with higher nidogen-1 in the posterior stroma than the anterior stroma. After endothelial scrape injury, concentrations of nidogen-1 appeared to be in the extracellular matrix of the posterior stroma and, possibly, within apoptotic bodies of stromal cells. Thus, posterior stromal cells, likely including keratocytes, undergo apoptosis in response to corneal endothelial injury, analogous to anterior keratocytes undergoing apoptosis in response to epithelial injury.


Assuntos
Apoptose , Membrana Basal/metabolismo , Lesões da Córnea/metabolismo , Lesões da Córnea/patologia , Substância Própria/patologia , Endotélio Corneano/lesões , Glicoproteínas de Membrana/metabolismo , Animais , Substância Própria/metabolismo , Substância Própria/ultraestrutura , DNA Nucleotidilexotransferase/metabolismo , Feminino , Imuno-Histoquímica , Marcação In Situ das Extremidades Cortadas , Microscopia Eletrônica de Transmissão , Coelhos , Vimentina/metabolismo
15.
Int Ophthalmol ; 38(1): 251-256, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28478533

RESUMO

PURPOSE: To evaluate the relationship between glaucoma diagnosis and the nailfold capillaroscopy pattern in patients with systemic sclerosis. METHODS: An observational study in a cohort of patients with SSc was conducted. Patients with at least one nailfold videocapillaroscopy and one ophthalmology examination at the same year were included. Data collected were: age, sex; type of systemic sclerosis according to the degree of skin impairment, self-reported ethnicity, disease duration, current use and dosage of systemic corticosteroid, current use and dosage of bosentan®, intraocular pressure, central corneal thickness, diagnosis of glaucoma and capillaroscopy pattern. RESULTS: Thirty-one patients with systemic sclerosis were enrolled, 23% had glaucoma. There was no statistically significant association between glaucoma diagnosis and the capillaroscopic pattern (p = 0.86). There was also no significant difference (p = 0.66) regarding intraocular pressure between patients with mild (13.9 ± 3.8 mmHg) and severe capillaroscopic pattern (14.4 ± 2.8 mmHg). The odds ratio of glaucoma for severe capillaroscopic pattern compared to mild was 1.6 (95% confidence interval: 0.3-9.5). CONCLUSION: Up to 23% of patients with SSc have glaucoma. The high prevalence of glaucoma in SSc suggests a possible systemic vascular disturbance as the cause. However, there seems to be no significant association between the capillaroscopy pattern and glaucoma in systemic sclerosis. Further research is required to improve the understanding of glaucoma in the context of systemic sclerosis.


Assuntos
Capilares/diagnóstico por imagem , Glaucoma/etiologia , Angioscopia Microscópica/métodos , Medição de Risco/métodos , Escleroderma Sistêmico/complicações , Adulto , Idoso , Brasil/epidemiologia , Progressão da Doença , Feminino , Glaucoma/diagnóstico , Glaucoma/epidemiologia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Unhas/irrigação sanguínea , Projetos Piloto , Prevalência , Escleroderma Sistêmico/diagnóstico , Tonometria Ocular/métodos
16.
Exp Eye Res ; 161: 101-105, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28506643

RESUMO

The purpose of this study was to investigate whether myofibroblast-related fibrosis (scarring) after microbial keratitis was modulated by the epithelial basement membrane (EBM) injury and regeneration. Rabbits were infected with Pseudomonas aeruginosa after epithelial scrape injury and the resultant severe keratitis was treated with topical tobramycin. Corneas were analyzed from one to four months after keratitis with slit lamp photos, immunohistochemistry for alpha-smooth muscle actin (α-SMA) and monocyte lineage marker CD11b, and transmission electron microscopy. At one month after keratitis, corneas had no detectible EBM lamina lucida or lamina densa, and the central stroma was packed with myofibroblasts that in some eyes extended to the posterior corneal surface with damage to Descemet's membrane and the endothelium. At one month, a nest of stromal cells in the midst of the SMA + myofibroblasts in the stroma that were CD11b+ may be fibrocyte precursors to myofibroblasts. At two to four months after keratitis, the EBM fully-regenerated and myofibroblasts disappeared from the anterior 60-90% of the stroma of all corneas, except for one four-month post-keratitis cornea where anterior myofibroblasts were still present in one localized pocket in the cornea. The organization of the stromal extracellular matrix also became less disorganized from two to four months after keratitis but remained abnormal compared to controls at the last time point. Myofibroblasts persisted in the posterior 10%-20% of posterior stroma even at four months after keratitis in the central cornea where Descemet's membrane and the endothelium were damaged. This study suggests that the EBM has a critical role in modulating myofibroblast development and fibrosis after keratitis-similar to the role of EBM in fibrosis after photorefractive keratectomy. Damage to EBM likely allows epithelium-derived transforming growth factor beta (TGFß) to penetrate the stroma and drive development and persistence of myofibroblasts. Eventual repair of EBM leads to myofibroblast apoptosis when the cells are deprived of requisite TGFß to maintain viability. The endothelium and Descemet's membrane may serve a similar function modulating TGFß penetration into the posterior stroma-with the source of TGFß likely being the aqueous humor.


Assuntos
Substância Própria/patologia , Úlcera da Córnea/patologia , Lâmina Limitante Posterior/fisiologia , Epitélio Corneano/fisiologia , Infecções Oculares Bacterianas/patologia , Infecções por Pseudomonas/patologia , Regeneração/fisiologia , Actinas/metabolismo , Animais , Biomarcadores/metabolismo , Antígeno CD11b/metabolismo , Lesões da Córnea/metabolismo , Lesões da Córnea/fisiopatologia , Substância Própria/metabolismo , Úlcera da Córnea/metabolismo , Modelos Animais de Doenças , Infecções Oculares Bacterianas/metabolismo , Feminino , Fibrose/patologia , Imuno-Histoquímica , Miofibroblastos/patologia , Infecções por Pseudomonas/metabolismo , Coelhos
17.
Curr Opin Ophthalmol ; 27(4): 311-5, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27096376

RESUMO

PURPOSE OF REVIEW: This article reviews the association of a novel metric, percentage tissue altered (PTA), with the occurrence of ectasia after laser in-situ keratomileusis in eyes with normal corneal topography, and analyses the influence of the variables that comprise it, and its role on eyes with suspicious topography. RECENT FINDINGS: PTA is derived from [PTA = (FT + AD)/CCT] where FT = flap thickness, AD = ablation depth, and CCT = preoperative central corneal thickness. Our studies revealed that there is a robust relationship between high PTA and ectasia risk in eyes with normal preoperative topography. PTA higher or equal to 40% presented the highest odds ratio and highest predictive capabilities for ectasia risk than each of the variables that comprise it, residual stromal bed or age. Average thicker flaps alone were insufficient to create ectasia unless coupled with greater ablation depths, meaning a high PTA. In eyes with suspicious topography, even low PTA value is sufficient to induce ectasia. SUMMARY: This new metric, PTA, should be taken into account when screening patients for refractive surgery. Patients with normal topography or tomography, presenting a PTA higher or equal to 40% should be considered at higher risk for post laser in-situ keratomileusis ectasia.


Assuntos
Córnea/fisiopatologia , Doenças da Córnea/fisiopatologia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Miopia/cirurgia , Córnea/cirurgia , Topografia da Córnea , Dilatação Patológica/fisiopatologia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Retalhos Cirúrgicos/patologia , Tomografia Computadorizada por Raios X
18.
J Refract Surg ; 31(4): 258-65, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25884581

RESUMO

PURPOSE: To investigate the association of the percent tissue altered (PTA) with the occurrence of ectasia after LASIK in eyes with suspicious preoperative corneal topography. METHODS: This retrospective comparative case-control study compared associations of reported ectasia risk factors in 129 eyes, including 57 eyes with suspicious preoperative Placido-based corneal topography that developed ectasia after LASIK (suspect ectasia group), 32 eyes with suspicious topography that remained stable for at least 3 years after LASIK (suspect control group), and 30 eyes that developed ectasia with bilateral normal topography (normal topography ectasia group). Groups were subdivided based on topographic asymmetry into high- or low-suspect groups. The PTA, preoperative central corneal thickness (CCT), residual stromal bed (RSB), and age (years) were evaluated in univariate and multivariate analyses. RESULTS: Average PTA values for normal topography ectasia (45), low-suspect ectasia (39), high-suspect ectasia (36), low-suspect control (32), and high-suspect control (29) were significantly different from one another in all comparisons (P < .003) except high- and low-suspect ectasia groups (P = .033), and presented the highest discriminative capability of all variables evaluated. Age was only significantly different between the high-suspect ectasia and normal topography ectasia groups, and CCT was not significantly different between any groups. Stepwise logistic regression revealed the PTA as the most significant independent variable (P < .0001), with RSB the next most significant parameter. CONCLUSIONS: There remains a significant correlation between PTA values and ectasia risk after LASIK, even in eyes with suspicious corneal topography. Less tissue alteration, or a lower PTA value, was necessary to induce ectasia in eyes with more remarkable signs of topographic abnormality, and PTA provided better discriminative capabilities than RSB for all study populations.


Assuntos
Doenças da Córnea/etiologia , Substância Própria/cirurgia , Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Complicações Pós-Operatórias , Estudos de Casos e Controles , Doenças da Córnea/diagnóstico , Dilatação Patológica/diagnóstico , Dilatação Patológica/etiologia , Humanos , Estudos Retrospectivos , Fatores de Risco
19.
J Refract Surg ; 31(6): 380-4, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26046704

RESUMO

PURPOSE: To evaluate the effectiveness and safety of accelerated corneal collagen cross-linking for postoperative LASIK ectasia after 2 years. METHODS: A prospective, single-center case series was performed with patients treated for postoperative LASIK ectasia. All eyes underwent accelerated corneal collagen cross-linking (CCL-Vario Crosslinking; Peschke Meditrade GmbH, Zurich, Switzerland) at 9 mW/cm(2) for 10 minutes. The main outcome measures were changes in uncorrected distance visual acuity, corrected distance visual acuity, central corneal thickness, corneal topography, and endothelial cell density. These parameters were assessed at baseline and at the 6-month and 1- and 2-year follow-up visit. RESULTS: The study enrolled 40 eyes of 24 patients (15 male and 9 female) with a mean age of 33.8 ± 7.5 years (range: 24 to 52 years) that attained at least 2 years of follow-up. The surgical procedure was uneventful in all cases. All eyes stabilized after treatment without any further signs of progression and no statistically significant changes in the mean uncorrected distance visual acuity (P = .649), corrected distance visual acuity (P = .616), mean keratometry (P =.837), steep keratometry (P = .956), ultrasonic pachymetry (P = .135), slit-scanning pachymetry (P = .276), and endothelial cell density (P = .523). In addition, 72.5% of the patients presented stable or gains of Snellen lines over time. CONCLUSIONS: Accelerated corneal collagen cross-linking seems to be safe and effective in halting postoperative LASIK ectasia progression after 2 years of follow-up. However, a longer follow-up period with a larger cohort is needed to validate these findings.


Assuntos
Colágeno/metabolismo , Substância Própria/metabolismo , Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ , Fármacos Fotossensibilizantes/uso terapêutico , Complicações Pós-Operatórias , Adulto , Córnea/diagnóstico por imagem , Córnea/patologia , Topografia da Córnea , Dilatação Patológica/tratamento farmacológico , Dilatação Patológica/etiologia , Dilatação Patológica/metabolismo , Feminino , Humanos , Ceratocone/tratamento farmacológico , Ceratocone/etiologia , Ceratocone/metabolismo , Lasers de Excimer , Masculino , Microscopia Acústica , Pessoa de Meia-Idade , Fotoquimioterapia , Estudos Prospectivos , Riboflavina/uso terapêutico , Acuidade Visual/fisiologia , Adulto Jovem
20.
J Refract Surg ; 31(6): 419-22, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26046710

RESUMO

PURPOSE: To report two cases of significant flattening after corneal cross-linking (CXL) for keratoconus and discuss its potential explanations and implications. METHODS: Observational case report. RESULTS: One year after standard CXL protocol (3 mW/cm(2) for 30 minutes and total energy of 5.4 J/cm(2)), a 28-year-old woman presented a flattening of greater than 14 diopters and a 14-year-old boy presented a flattening of 7 diopters. CONCLUSIONS: Although rare, a significant flattening effect may occur during the first year after CXL, probably related to intense wound healing, increase in corneal elasticity, CXL effective depth, and central cone location. These cases suggest the necessity of a patient-specific approach and a better understanding regarding the actual mechanism behind its potent effect.


Assuntos
Colágeno/metabolismo , Córnea/patologia , Substância Própria/metabolismo , Reagentes de Ligações Cruzadas , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Adolescente , Adulto , Fenômenos Biomecânicos , Topografia da Córnea , Elasticidade/fisiologia , Feminino , Humanos , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Masculino , Riboflavina/uso terapêutico , Raios Ultravioleta , Cicatrização/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA