1.
IEEE J Biomed Health Inform ; 26(7): 2864-2875, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35201992

RESUMO

OBJECTIVE: While non-invasive, cuffless blood pressure (BP) measurement has demonstrated relevancy in controlled environments, ambulatory measurement is important for hypertension diagnosis and control. We present both in-lab and ambulatory BP estimation results from a diverse cohort of participants. METHODS: Participants (N=1125, aged 21-85, 49.2% female, multiple hypertensive categories) had BP measured in-lab over a 24-hour period with a subset also receiving ambulatory measurements. Radial tonometry, photoplethysmography (PPG), electrocardiography (ECG), and accelerometry signals were collected simultaneously with auscultatory or oscillometric references for systolic (SBP) and diastolic blood pressure (DBP). Predictive models to estimate BP using a variety of sensor-based feature groups were evaluated against challenging baselines. RESULTS: Despite limited availability, tonometry-derived features showed superior performance compared to other feature groups and baselines, yieldingprediction errors of 0.32 ±9.8 mmHg SBP and 0.54 ±7.7 mmHg DBP in-lab, and 0.86 ±8.7 mmHg SBP and 0.75 ±5.9 mmHg DBP for 24-hour averages. SBP error standard deviation (SD) was reduced in normotensive (in-lab: 8.1 mmHg, 24-hr: 7.2 mmHg) and younger (in-lab: 7.8 mmHg, 24-hr: 6.7 mmHg) subpopulations. SBP SD was further reduced 15-20% when constrained to the calibration posture alone. CONCLUSION: Performance for normotensive and younger participants was superior to the general population across all feature groups. Reference type, posture relative to calibration, and controlled vs. ambulatory setting all impacted BP errors. SIGNIFICANCE: Results highlight the need for demographically diverse populations and challenging evaluation settings for BP estimation studies. We present the first public dataset of ambulatory tonometry and cuffless BP over a 24-hour period to aid in future cardiovascular research.


Assuntos
Hipertensão , Dispositivos Eletrônicos Vestíveis , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Eletrocardiografia , Feminino , Humanos , Masculino , Manometria , Fotopletismografia/métodos
2.
Med Eng Phys ; 38(10): 1063-9, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27426984

RESUMO

Although hemodynamic parameters can be assessed non-invasively, state-of-the-art non-invasive systems generally require an expert operator and are not applicable for ambulatory measurements. These limitations have restricted our understanding of the continuous behavior of hemodynamic parameters. In this manuscript, we introduce a novel wrist-mounted device that incorporates an array of pressure sensors which can be used to extract arterial waveforms and relevant pulse wave analysis biomarkers. In vivo evaluation is performed with Bland-Altman analysis to compare the novel sensor to a gold-standard hand-held tonometer by assessing their reproducibility and agreement in peripheral augmentation index (AIx) estimation at the radial artery. Arterial waves from 28 randomly selected participants were recorded in a controlled environment. Initially we assess the reproducibility of AIx results for both devices. The intra-class correlation coefficient (ICC) and mean difference ± SD were [0.913, 0.033±0.048] and [0.859, 0.039±0.076] for the hand-held and the wrist-mounted tonometer respectively. We then show that the AIx values derived from the novel tonometer have good agreement, accuracy, and precision when compared against the AIx values derived from the reference hand-held tonometer (ICC 0.927, mean difference 0.026±0.049). In conclusion, we have presented evidence that the new wrist-mounted arterial pressure sensor records arterial waveforms that can be processed to yield AIx values that are in good agreement with its traditional hand-held counterpart.


Assuntos
Pressão Arterial , Determinação da Pressão Arterial/instrumentação , Mãos , Manometria/instrumentação , Punho , Adolescente , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem