1.
Eur Radiol ; 34(3): 1716-1723, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37644149

RESUMO

OBJECTIVES: To introduce an automated computational algorithm that estimates the global noise level across the whole imaging volume of PET datasets. METHODS: [18F]FDG PET images of 38 patients were reconstructed with simulated decreasing acquisition times (15-120 s) resulting in increasing noise levels, and with block sequential regularized expectation maximization with beta values of 450 and 600 (Q.Clear 450 and 600). One reader performed manual volume-of-interest (VOI) based noise measurements in liver and lung parenchyma and two readers graded subjective image quality as sufficient or insufficient. An automated computational noise measurement algorithm was developed and deployed on the whole imaging volume of each reconstruction, delivering a single value representing the global image noise (Global Noise Index, GNI). Manual noise measurement values and subjective image quality gradings were compared with the GNI. RESULTS: Irrespective of the absolute noise values, there was no significant difference between the GNI and manual liver measurements in terms of the distribution of noise values (p = 0.84 for Q.Clear 450, and p = 0.51 for Q.Clear 600). The GNI showed a fair to moderately strong correlation with manual noise measurements in liver parenchyma (r = 0.6 in Q.Clear 450, r = 0.54 in Q.Clear 600, all p < 0.001), and a fair correlation with manual noise measurements in lung parenchyma (r = 0.52 in Q.Clear 450, r = 0.33 in Q.Clear 600, all p < 0.001). Classification performance of the GNI for subjective image quality was AUC 0.898 for Q.Clear 450 and 0.919 for Q.Clear 600. CONCLUSION: An algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. CLINICAL RELEVANCE STATEMENT: An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking of clinical PET imaging within and across institutions. KEY POINTS: • Noise is an important quantitative marker that strongly impacts image quality of PET images. • An automated computational noise measurement algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. • An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking as well as protocol harmonization.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Fígado/diagnóstico por imagem , Algoritmos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagens de Fantasmas
2.
J Nucl Cardiol ; 30(1): 313-320, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35301677

RESUMO

BACKGROUND: To assess the accuracy of fully automated deep learning (DL) based coronary artery calcium scoring (CACS) from non-contrast computed tomography (CT) as acquired for attenuation correction (AC) of cardiac single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI). METHODS AND RESULTS: Patients were enrolled in this study as part of a larger prospective study (NCT03637231). In this study, 56 Patients who underwent cardiac SPECT-MPI due to suspected coronary artery disease (CAD) were prospectively enrolled. All patients underwent non-contrast CT for AC of SPECT-MPI twice. CACS was manually assessed (serving as standard of reference) on both CT datasets (n = 112) and by a cloud-based DL tool. The agreement in CAC scores and CAC score risk categories was quantified. For the 112 scans included in the analysis, interscore agreement between the CAC scores of the standard of reference and the DL tool was 0.986. The agreement in risk categories was 0.977 with a reclassification rate of 3.6%. Heart rate, image noise, body mass index (BMI), and scan did not significantly impact (p=0.09 - p=0.76) absolute percentage difference in CAC scores. CONCLUSION: A DL tool enables a fully automated and accurate estimation of CAC scores in patients undergoing non-contrast CT for AC of SPECT-MPI.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Imagem de Perfusão do Miocárdio , Humanos , Cálcio , Imagem de Perfusão do Miocárdio/métodos , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
3.
AJR Am J Roentgenol ; 218(1): 132-139, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34406050

RESUMO

BACKGROUND. Sequences with noncartesian k-space sampling may improve image quality of head and neck MRI. OBJECTIVE. The purpose of this study was to compare intraindividually the image quality of a spiral gradient-recalled echo (GRE) sequence and conventional cartesian GRE and cartesian turbo spin-echo (TSE) sequences for contrast-enhanced T1-weighted head and neck MRI. METHODS. This prospective study included patients referred for contrast-enhanced head and neck MRI from August 2020 to May 2021. Patients underwent 1.5-T MRI including contrast-enhanced spiral GRE (2 minutes 28 seconds), cartesian GRE (4 minutes 27 seconds), and cartesian TSE (3 minutes 41 seconds) sequences, acquired in rotating order across patients. Three radiologists independently assessed image quality measures, including conspicuity of prespecified lesions, using 5-point Likert scales. One reader measured maximal extent of dental material artifact and contrast-to-noise ratio (CNR). RESULTS. Thirty-one patients (13 men, 18 women; mean age, 63.8 years) were enrolled. Nineteen patients had a focal lesion; 22 had dental material. Interreader agreement for image quality measures was substantial to excellent (Krippendorff alpha, 0.681-1.000). Scores for overall image quality (whole head and neck, neck only, and head only), pulsation artifact, muscular contour delineation, vessel contour delineation, motion artifact, and differentiation between mucosa and pharyngeal muscles were significantly better for spiral GRE than for cartesian GRE and cartesian TSE for all readers (p < .05). Scores for lesion conspicuity (whole head and neck, neck only, and head only), quality of fat suppression, flow artifact, and foldover artifact were not significantly different between spiral GRE and the cartesian sequences for any reader (p > .05). Dental material artifact scores were significantly worse for spiral GRE than the other sequences for all readers (p < .05). The mean maximum extent of dental material artifact was 39.6 ± 25.5 (SD) mm for spiral GRE, 35.6 ± 24.3 mm for cartesian GRE, and 29.6 ± 21.4 mm for cartesian TSE; the mean CNR was 221.1 ± 94.5 for spiral GRE, 151.8 ± 85.7 for cartesian GRE, and 153.0 ± 63.2 for cartesian TSE (p < .001 between spiral GRE and other sequences for both measures). CONCLUSION. Three-dimensional spiral GRE improves subjective image quality and CNR of head and neck MRI with shorter scan time versus cartesian sequences, though it exhibits larger dental material artifact. CLINICAL IMPACT. A spiral sequence may help overcome certain challenges of conventional cartesian sequences for head and neck MRI.


Assuntos
Meios de Contraste , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Cabeça/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes
4.
Eur Radiol ; 31(11): 8725-8732, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33909134

RESUMO

OBJECTIVES: We investigate in what percentage of cases and to what extent radiological reports change when radiologists directly communicate with patients after imaging examinations. METHODS: One hundred twenty-two consecutive outpatients undergoing MRI examinations at a single center were prospectively included. Radiological reports of the patients were drafted by two radiologists in consensus using only the clinical information that was made available by the referring physicians. Thereafter, one radiologist talked directly with the patient and recorded the duration of the conversation. Afterwards, the additional information from the patient was used to reevaluate the imaging studies in consensus. The radiologists determined whether the radiological report changed based on additional information and, if yes, to what extent. The degree of change was graded on a 4-point Likert scale (1, non-relevant findings, to 4, highly relevant findings). RESULTS: Following direct communication (duration 170.9 ± 53.9 s), the radiological reports of 52 patients (42.6%) were changed. Of the 52 patients, the degree of change was classified as grade 1 for 8 patients (15.4 %), grade 2 for 27 patients (51.9%), grade 3 for 13 patients (25%), and grade 4 for 4 patients (7.7%). The reasons leading to changes were missing clinical information in 50 cases (96.2%) and the lack of additional external imaging in 2 cases (3.8%). CONCLUSIONS: Radiologists should be aware that a lack of accurate information from the clinician can lead to incorrect radiological reports or diagnosis. Radiologists should communicate directly with patients, especially when the provided information is unclear, as it may significantly alter the radiological report. KEY POINTS: • Direct communication between radiologists and patients for an average of 170's resulted in a change in the radiological reports of 52 patients (42.6%). • Of the 42.6% of cases where the reports were changed, the alterations were highly relevant (grades 3 and 4) in 32.7%, indicating major changes with significant impact towards patient management.


Assuntos
Radiologistas , Radiologia , Comunicação , Humanos , Imageamento por Ressonância Magnética , Radiografia
5.
BMC Ophthalmol ; 19(1): 258, 2019 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-31842814

RESUMO

BACKGROUND: In this retrospective study the relationship between intraocular pressure (IOP), retinal nerve fiber layer (RNFL) thickness and pathologic hypersignal in optic nerve segments on 3D double inversion recovery (DIR) MR sequence in 21 patients with proven glaucoma of different origin was evaluated. METHODS: All patients were examined on a 3 T MR Philips® scanner. Pathologic optic nerve DIR hypersignal was determined in four different nerve segments. IOP was measured in mmHg by applanation tonometry. RNFL thickness was measured in µm with optical coherence tomography (OCT Heidelberg Engineering Spectralis® apparatus). Wilcoxon rank sum tests, student's t-tests and (multivariate) linear regression models were appied. RESULTS: 3D DIR hypersignal was present in 17 (41.5%) optic nerves. 3D DIR hypersignal was not related to ischemic or demyelinating optic nerve pathology but was associated with increased IOP (19.8 [24-18]; versus 15.45; [18.85-13.75] mmHg; p = 0.008) and decreased RNFL thickness (61.06 ± 12.1 versus 82.5 ± 21.6 µm; p < 0.001) in comparison to optic nerves of glaucoma patients without DIR hypersignal. Specifically, presence of DIR hypersignal in optic nerves in at least one optic nerve segment lowered RNFL thickness on average by 17.54 µm (p = 0.005) in comparison to optic nerves without DIR hypersignal. CONCLUSIONS: In patients with glaucomatous optic neuropathy (GON) and pathologic optic nerve DIR hypersignal, significantly increased IOP and significantly decreased RNFL thickness values are present. DIR hypersignal seems to be a marker for disease severity in GON related to decreased RNFL thickness and may thus represent long-segment severe axonal degeneration in optic nerves in patients with GON. Venous congestion and edema within the optic nerve related to high IOP may contribute to the DIR hypersignal as well.


Assuntos
Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Fibras Nervosas/patologia , Doenças do Nervo Óptico/fisiopatologia , Células Ganglionares da Retina/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma de Ângulo Fechado/diagnóstico por imagem , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Doenças do Nervo Óptico/diagnóstico por imagem , Estudos Retrospectivos , Tomografia de Coerência Óptica , Tonometria Ocular , Testes de Campo Visual , Campos Visuais/fisiologia
6.
Eur Radiol ; 27(10): 4181-4187, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28374081

RESUMO

OBJECTIVES: Aim was to investigate hygienic conditions of ultrasound probes before and after hygiene training in radiology institutions in comparison to bacterial contamination in public places. METHODS: In three radiology departments, bacterial contamination was evaluated using baseline agar plates for cultures taken from 36 ultrasound probes. Afterwards teams were trained by a hygiene service centre and 36 ultrasound probes were routinely disinfected with regular disinfecting wipes and then evaluated. In comparison, bacterial contamination in public places (bus poles, n = 11; toilet seats, n = 10) were analysed. Plates were routinely incubated and the number of colony forming units (CFU) analysed. RESULTS: Cultures taken from the probes showed a median of 53 CFU before and 0 CFU after training (p < 0.001). Cultures taken from public places showed a median of 4 CFU from toilets and 28 from bus poles and had lower bacterial load in comparison to ultrasound probes before training (p = 0.055, toilets; p = 0.772, bus poles), without statistical significance. CONCLUSIONS: Bacterial contamination of ultrasound probes prior to hygiene training proved to be high and showed higher bacterial load than toilets seats or bus poles. Radiologists should be aware that the lack of hygiene in the field of ultrasound diagnostics puts patients at risk of healthcare-associated infections. KEY POINTS: • Hospital-associated infections are a problem for patient care. • Hygiene training of staff prevents bacterial contamination of ultrasound probes. • Disinfection of ultrasound probes is an easy method to protect patients.


Assuntos
Bactérias/isolamento & purificação , Desinfetantes/uso terapêutico , Desinfecção/normas , Contaminação de Equipamentos/prevenção & controle , Higiene/educação , Transdutores/microbiologia , Ultrassonografia/instrumentação , Contagem de Colônia Microbiana , Infecção Hospitalar/prevenção & controle , Humanos
7.
J Clin Med ; 13(8)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38673617

RESUMO

Background: MRI diagnostics are important for adenomyosis, especially in cases with inconclusive ultrasound. This study assessed the potential of MRI-based radiomics as a novel tool for differentiating between uteri with and without adenomyosis. Methods: This retrospective proof-of-principle single-center study included nine patients with and six patients without adenomyosis. All patients had preoperative T2w MR images and histological findings served as the reference standard. The uterus of each patient was segmented in 3D using dedicated software, and 884 radiomics features were extracted. After dimension reduction and feature selection, the diagnostic yield of individual and combined features implemented in the machine learning models were assessed by means of receiver operating characteristics analyses. Results: Eleven relevant radiomics features were identified. The diagnostic performance of individual features in differentiating adenomyosis from the control group was high, with areas under the curve (AUCs) ranging from 0.78 to 0.98. The performance of ML models incorporating several features was excellent, with AUC scores of 1 and an area under the precision-recall curve of 0.4. Conclusions: The set of radiomics features derived from routine T2w MRI enabled accurate differentiation of uteri with adenomyosis. Radiomics could enhance diagnosis and furthermore serve as an imaging biomarker to aid in personalizing therapies and monitoring treatment responses.

8.
Sci Rep ; 13(1): 969, 2023 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-36653482

RESUMO

The aim of this study was to develop a magnetic resonance imaging (MRI) based radiomics model to predict mitosis cycles in intracranial meningioma grading prior to surgery. Preoperative contrast-enhanced T1-weighted (T1CE) cerebral MRI data of 167 meningioma patients between 2015 and 2020 were obtained, preprocessed and segmented using the 3D Slicer software and the PyRadiomics plugin. In total 145 radiomics features of the T1CE MRI images were computed. The criterion on the basis of which the feature selection was made is whether the number of mitoses per 10 high power field (HPF) is greater than or equal to zero. Our analyses show that machine learning algorithms can be used to make accurate predictions about whether the number of mitoses per 10 HPF is greater than or equal to zero. We obtained our best model using Ridge regression for feature pre-selection, followed by stepwise logistic regression for final model construction. Using independent test data, this model resulted in an AUC (Area under the Curve) of 0.8523, an accuracy of 0.7941, a sensitivity of 0.8182, a specificity of 0.7500 and a Cohen's Kappa of 0.5576. We analyzed the performance of this model as a function of the number of mitoses per 10 HPF. The model performs well for cases with zero mitoses as well as for cases with more than one mitosis per 10 HPF. The worst model performance (accuracy = 0.6250) is obtained for cases with one mitosis per 10 HPF. Our results show that MRI-based radiomics may be a promising approach to predict the mitosis cycles in intracranial meningioma prior to surgery. Specifically, our approach may offer a non-invasive means of detecting the early stages of a malignant process in meningiomas prior to the onset of clinical symptoms.


Assuntos
Neoplasias Meníngeas , Meningioma , Humanos , Meningioma/patologia , Neoplasias Meníngeas/patologia , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Mitose
9.
Br J Radiol ; 96(1152): 20220482, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37751216

RESUMO

OBJECTIVES: To evaluate the evolution of CT radiation dose in pediatric patients undergoing hybrid 2-[18F]fluoro-2-deoxy-D-glucose (2-[18F]FDG) PET/CT between 2007 and 2021. METHODS AND MATERIALS: Data from all pediatric patients aged 0-18 years who underwent hybrid 2-[18F]FDG PET/CT of the body between January 2007 and May 2021 were reviewed. Demographic and imaging parameters were collected. A board-certified radiologist reviewed all CT scans and measured image noise in the brain, liver, and adductor muscles. RESULTS: 294 scans from 167 children (72 females (43%); median age: 14 (IQR 10-15) years; BMI: median 17.5 (IQR 15-20.4) kg/m2) were included. CT dose index-volume (CTDIvol) and dose length product (DLP) both decreased significantly from 2007 to 2021 (both p < 0.001, Spearman's rho coefficients -0.46 and -0.35, respectively). Specifically, from 2007 to 2009 to 2019-2021 CTDIvol and DLP decreased from 2.94 (2.14-2.99) mGy and 309 (230-371) mGy*cm, respectively, to 0.855 (0.568-1.11) mGy and 108 (65.6-207) mGy*cm, respectively. From 2007 to 2021, image noise in the brain and liver remained constant (p = 0.26 and p = 0.06), while it decreased in the adductor muscles (p = 0.007). Peak tube voltage selection (in kilovolt, kV) of CT scans shifted from high kV imaging (140 or 120kVp) to low kV imaging (100 or 80kVp) (p < 0.001) from 2007 to 2021. CONCLUSION: CT radiation dose in pediatric patients undergoing hybrid 2-[18F]FDG PET/CT has decreased in recent years equaling approximately one-third of the initial amount. ADVANCES IN KNOWLEDGE: Over the past 15 years, CT radiation dose decreased considerably in pediatric patients undergoing hybrid imaging, while objective image quality may not have been compromised.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Feminino , Humanos , Criança , Adolescente , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Encéfalo
10.
Sci Rep ; 13(1): 18357, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37884535

RESUMO

This study aimed to evaluate the diagnostic accuracy of Node Reporting and Data System (Node-RADS) in discriminating between normal, reactive, and metastatic axillary LNs in patients with melanoma who underwent SARS-CoV-2 vaccination. Patients with proven melanoma who underwent a 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (2-[18F]-FDG PET/CT) between February and April 2021 were included in this retrospective study. Primary melanoma site, vaccination status, injection site, and 2-[18F]-FDG PET/CT were used to classify axillary LNs into normal, inflammatory, and metastatic (combined classification). An adapted Node-RADS classification (A-Node-RADS) was generated based on LN anatomical characteristics on low-dose CT images and compared to the combined classification. 108 patients were included in the study (54 vaccinated). HALNs were detected in 42 patients (32.8%), of whom 97.6% were vaccinated. 172 LNs were classified as normal, 30 as inflammatory, and 14 as metastatic using the combined classification. 152, 22, 29, 12, and 1 LNs were classified A-Node-RADS 1, 2, 3, 4, and 5, respectively. Hence, 174, 29, and 13 LNs were deemed benign, equivocal, and metastatic. The concordance between the classifications was very good (Cohen's k: 0.91, CI 0.86-0.95; p-value < 0.0001). A-Node-RADS can assist the classification of axillary LNs in melanoma patients who underwent 2-[18F]-FDG PET/CT and SARS-CoV-2 vaccination.


Assuntos
COVID-19 , Melanoma , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Vacinas contra COVID-19 , SARS-CoV-2 , Fluordesoxiglucose F18 , Estudos Retrospectivos , Estadiamento de Neoplasias , Metástase Linfática/patologia , COVID-19/diagnóstico por imagem , COVID-19/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Melanoma/diagnóstico por imagem , Melanoma/patologia , Vacinação , Compostos Radiofarmacêuticos
11.
PLoS One ; 18(11): e0291007, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37939048

RESUMO

INTRODUCTION: A trend towards less male radiologists specializing in breast ultrasound was observed. A common notion in the field of breast radiology is, that female patients feel more comfortable being treated by female radiologists. The aim of the study was to understand and report the needs of women undergoing breast ultrasound with regards to the sex of the radiologist performing the investigation. METHODS: Informed consent was obtained from all patients prior to inclusion in a prospective bi-center quality study. At center 1 (72 patients), the women were examined exclusively by female radiologists, at center 2 (100 patients) only by male radiologists. After the examination the patients were asked about their experiences and their wishes for the future. RESULTS: Overall, women made no distinction between female and male radiologists; 25% of them wanted a female radiologist and 1.2% wanted a male radiologist. The majority (74%) stated that it made no difference whether a female or male radiologist performed the examination. The majority of women in group 2, who were investigated exclusively by male radiologists, stated that they had no preferences with regard to the sex of the radiologist (93%); 5% of the women wished to be investigated solely by a female radiologist and 2% exclusively by a male radiologist. DISCUSSION: The majority of women undergoing breast ultrasound are unconcerned about the radiologist's sex. It would appear that women examined by male radiologists are less selective about the sex of the examining radiologist. TRIAL REGISTRATION: Written informed consent was obtained from all patients. All patient data were anonymized. The physicians had no access to any further personal data. National regulations did not require dedicated ethics approval with anonymized lists or retrospective questionnaires.


Assuntos
Neoplasias da Mama , Médicos , Humanos , Feminino , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Radiologistas , Ultrassonografia Mamária
12.
Tomography ; 8(1): 257-266, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35202186

RESUMO

Radiculopathy can be caused by nerve root irritation and nerve root compression at the level of the lateral recess or at the level of the intervertebral foramen. T2-weighted (T2w) MRI is considered essential to evaluate the nerve root and its course, starting at the lateral recess through the intervertebral foramen to the extraforaminal space. With the introduction of novel MRI acceleration techniques such as compressed SENSE, standard-resolution 2D T2w turbo spin echo (TSE) sequences with a slice-thickness of 3-4 mm can be replaced with high-resolution isotropic 3D T2w TSE sequences with sub-millimeter resolution without prolonging scan time. With high-resolution 3D MRI, the course of the nerve root can be visualized more precisely due to a detailed depiction of the anatomical situation and less partial volume effects, potentially allowing for a better detection of nerve root compromise. In this intra-individual comparison study, 55 patients with symptomatic unilateral singular nerve root radiculopathy underwent MRI with both 2D standard- and 3D high-resolution T2w TSE MRI sequences. Two readers graded the degree of lumbar lateral recess stenosis and lumbar foraminal stenosis twice on both image sets using previously validated grading systems in an effort to quantify the inter-readout and inter-sequence agreement of scores. Inter-readout agreement was high for both grading systems and for 2D and 3D imaging (Kappa = 0.823-0.945). Inter-sequence agreement was moderate for both lumbar lateral recess stenosis (Kappa = 0.55-0.577) and lumbar foraminal stenosis (Kappa = 0.543-0.572). The percentage of high degree stenosis with nerve root deformity increased from 16.4%/9.8% to 41.8-43.6%/34.1% from 2D to 3D images for lateral recess stenosis/foraminal stenosis, respectively. Therefore, we show that while inter-readout agreement of grading systems is high for both standard- and high-resolution imaging, the latter outperforms standard-resolution imaging for the visualization of lumbar nerve root compromise.


Assuntos
Imageamento por Ressonância Magnética , Radiculopatia , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Radiculopatia/diagnóstico por imagem , Raízes Nervosas Espinhais/diagnóstico por imagem
13.
Br J Radiol ; 95(1135): 20210354, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34762522

RESUMO

OBJECTIVES: To compare a novel 3D spiral gradient echo (GRE) sequence with a conventional 2D cartesian turbo spin echo (TSE) sequence for sagittal contrast-enhanced (CE) fat-suppressed (FS) T1 weighted (T1W) spine MRI. METHODS: In this inter-individual comparison study, 128 patients prospectively underwent sagittal CE FS T1W spine MRI with either a 2D cartesian TSE ("TSE", 285 s, 64 patients) or a 3D spiral GRE sequence ("Spiral", 93 s, 64 patients). Between both groups, patients were matched in terms of anatomical region (cervical/thoracic/lumbar spine and sacrum). Three readers used 4-point Likert scales to assess images qualitatively in terms of overall image quality, presence of artifacts, spinal cord visualization, lesion conspicuity and quality of fat suppression. RESULTS: Spiral achieved a 67.4% scan time reduction compared to TSE. Interreader agreement was high (alpha=0.868-1). Overall image quality (4;[3,4] vs 3;[3,4], p<0.001 - p=0.002 for all readers), presence of artifacts (4;[3,4] vs 3;[3,4] p=0.027 - p=0.046 for all readers), spinal cord visualization (4;[4,4] vs 4;[3,4], p<0.001 for all readers), lesion conspicuity (4;[4,4] vs 4;[4,4], p=0.016 for all readers) and quality of fat suppression (4;[4,4] vs 4;[4,4], p=0.027 - p=0.033 for all readers), were all deemed significantly improved by all three readers on Spiral images as compared to TSE images. CONCLUSION: We demonstrate the feasibility of a novel 3D spiral GRE sequence for improved and rapid sagittal CE FS T1W spine MRI. ADVANCES IN KNOWLEDGE: A 3D spiral GRE sequence allows for improved sagittal CE FS T1W spine MRI at very short scan times.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Pelve , Coluna Vertebral
14.
Phys Med ; 93: 20-28, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34902771

RESUMO

PURPOSE: To assess the clinical feasibility of spiral 3D Time-Of-Flight (TOF) MR Angiography (MRA) sequence variants for rapid non-contrast carotid artery imaging. METHODS: Nine different 3D TOF MRA sequences were acquired in nine healthy volunteers on a standard clinical 1.5 T scanner. Three cartesian sequences (fully sampled (10:15 min), accelerated with SENSE (05:08 min), accelerated with Compressed SENSE (03:32 min)) and six different spiral sequences were acquired (spiral acquisition windows ranging from 10 to 5 ms (01:32 min-03:05 min)). Three readers graded the images qualitatively in terms of overall image quality, vessel sharpness, inhomogeneous intraluminal signal, background noise, visualization of large and small vessels and overall impression of the number of visible vessels. Cross-sectional areas of the vessel lumen were measured and vessel sharpness was quantified. RESULTS: The SENSE and Compressed SENSE accelerated cartesian sequences and the Spiral 6 ms and 5 ms sequences were deemed comparable to the fully sampled cartesian sequence in most qualitative categories (p > 0.05) based on exact binomial tests. The Spiral 6 ms and 5 ms sequences achieved a scan time reduction of 75.3% and 69.9% respectively compared to the fully sampled cartesian sequence. The spiral sequences (generally) exhibited improved subjective vessel sharpness (p < 0.01-p = 0.13) but increased background noise (p = 0.03-p = 0.25). Cross-sectional area measurements were similar between all sequences (Krippendorff's alpha: 0.955-0.982). Quantitative vessel sharpness was increased for all spiral sequences compared to all cartesian sequences (p = 0.004). CONCLUSIONS: Spiral 3D TOF MRA sequences with a spiral acquisition window of 5 ms or 6 ms may be used for accurate, rapid, clinical non-contrast carotid artery imaging.


Assuntos
Imageamento Tridimensional , Angiografia por Ressonância Magnética , Artérias Carótidas/diagnóstico por imagem , Estudos de Viabilidade , Voluntários Saudáveis , Humanos
15.
Eur J Radiol ; 151: 110320, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35462272

RESUMO

BACKGROUND & AIMS: To determine if radiological hard- and software offers options beyond the binary female / male classification. METHODS: We surveyed thirteen radiological hardware and six radiological software vendors about the options to enter patient gender. RESULTS: Six of thirteen hardware and five of six software vendors replied to our inquiry. All vendors except one offered a third option in addition to male / female. CONCLUSION: We found that most hard- and software systems provide with a third option for patient gender. These systems allow radiology personnel to accurately document patient gender in the medical record and contribute to an inclusive patient experience in the radiology department. Registering the biological sex in addition to gender may further improve medical care.


Assuntos
Radiologia , Pessoas Transgênero , Feminino , Identidade de Gênero , Humanos , Masculino , Radiografia , Inquéritos e Questionários
16.
Eur J Radiol ; 156: 110549, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36272226

RESUMO

PURPOSE: To assess the performance of semi-automated volumetry of solid pulmonary nodules on single-energy tin-filtered ultralow dose (ULD) chest CT scans at a radiation dose equivalent to chest X-ray relative to standard dose (SD) chest CT scans and assess the impact of kernel and iterative reconstruction selection. METHODS: Ninety-four consecutive patients from a prospective single-center study were included and underwent clinically indicated SD chest CT (1.9 ± 0.8 mSv) and additional ULD chest CT (0.13 ± 0.01 mSv) in the same session. All scans were reconstructed with a soft tissue (Br40) and lung (Bl64) kernel as well as with Filtered Back Projection (FBP) and Iterative Reconstruction (ADMIRE-3 and ADMIRE-5). One hundred and forty-eight solid pulmonary nodules were identified and analysed by semi-automated volumetry on all reconstructions. Nodule volumes were compared amongst all reconstructions thereby focusing on the agreement between SD and ULD scans. RESULTS: Nodule volumes ranged from 58.5 (28.8-126) mm3 for ADMIRE-5 Br40 ULD reconstructions to 72.5 (39-134) mm3 for FBP Bl64 SD reconstructions with significant differences between reconstructions (p < 0.001). Interscan agreement of volumes between two given reconstructions ranged from ICC = 0.605 to ICC = 0.999. Between SD and ULD scans, agreement of nodule volumes was highest for FBP Br40 (ICC = 0.995), FBP Bl64 (ICC = 0.939) and ADMIRE-5 Bl64 (ICC = 0.994) reconstructions. ADMIRE-3 reconstructions exhibited reduced interscan agreement of nodule volumes (ICCs from 0.788 - 0.882). CONCLUSIONS: The interscan agreement of node volumes between SD and ULD is high depending on the choice of kernel and reconstruction algorithm. However, caution should be exercised when comparing two image series that were not identically reconstructed.

17.
Acad Radiol ; 29(2): 269-276, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33158702

RESUMO

OBJECTIVES: Acoustic noise emission from MRI scanners is considered a major factor of patient discomfort during routine MRI examinations. We prospectively evaluated the impact of acoustic noise reduction using software implementations in routine clinical MRI on subjective patient experience and image quality. METHODS: Two-hundred consecutive patients undergoing one of four MRI examinations (brain, lumbar spine, shoulder, and knee) at a single center were prospectively randomized into two groups at a 1 to 1 ratio: standard MRI examination and MRI examination with acoustic noise reduction. After the examination, patients were asked to complete a questionnaire aimed at defining their subjective experience (primary endpoint). Two readers assessed subjective image quality of all patient studies in consensus (secondary endpoint). Nonparametric tests and logistic regression models were used for statistical analysis. RESULTS: Hundred-seventy-four patients were included in the final study. Patients in the intervention group felt less discomforted by the acoustic noise (p = 0.01) and reported increased audibility of music through the headphones (p = 0.03). No significant difference in subjective image quality was found. CONCLUSION: Our study indicates that the effects of acoustic noise reduction in routine clinical MRI can be translated into reduced patient discomfort from acoustic noise and improved audibility of music. Acoustic noise reduction thus significantly contributes to increased patient comfort during MRI examinations.


Assuntos
Acústica , Imageamento por Ressonância Magnética , Humanos , Ruído , Avaliação de Resultados da Assistência ao Paciente , Razão Sinal-Ruído
18.
Diagnostics (Basel) ; 12(8)2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-36010226

RESUMO

OBJECTIVES: The objective of this study was to assess the feasibility and accuracy of a fully automated artificial intelligence (AI) powered coronary artery calcium scoring (CACS) method on ungated CT in oncologic patients undergoing 18F-FDG PET/CT. METHODS: A total of 100 oncologic patients examined between 2007 and 2015 were retrospectively included. All patients underwent 18F-FDG PET/CT and cardiac SPECT myocardial perfusion imaging (MPI) by 99mTc-tetrofosmin within 6 months. CACS was manually performed on non-contrast ECG-gated CT scans obtained from SPECT-MPI (i.e., reference standard). Additionally, CACS was performed using a cloud-based, user-independent tool (AI-CACS) on ungated CT scans from 18F-FDG-PET/CT examinations. Agatston scores from the manual CACS and AI-CACS were compared. RESULTS: On a per-patient basis, the AI-CACS tool achieved a sensitivity and specificity of 85% and 90% for the detection of CAC. Interscore agreement of CACS between manual CACS and AI-CACS was 0.88 (95% CI: 0.827, 0.918). Interclass agreement of risk categories was 0.8 in weighted Kappa analysis, with a reclassification rate of 44% and an underestimation of one risk category by AI-CACS in 39% of cases. On a per-vessel basis, interscore agreement of CAC scores ranged from 0.716 for the circumflex artery to 0.863 for the left anterior descending artery. CONCLUSIONS: Fully automated AI-CACS as performed on non-contrast free-breathing, ungated CT scans from 18F-FDG-PET/CT examinations is feasible and provides an acceptable to good estimation of CAC burden. CAC load on ungated CT is, however, generally underestimated by AI-CACS, which should be taken into account when interpreting imaging findings.

19.
Sci Rep ; 12(1): 19191, 2022 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-36357446

RESUMO

Our aim was to identify and quantify high coronary artery calcium (CAC) with deep learning (DL)-powered CAC scoring (CACS) in oncological patients with known very high CAC (≥ 1000) undergoing 18F-FDG-PET/CT for re-/staging. 100 patients were enrolled: 50 patients with Agatston scores ≥ 1000 (high CACS group), 50 patients with Agatston scores < 1000 (negative control group). All patients underwent oncological 18F-FDG-PET/CT and cardiac SPECT myocardial perfusion imaging (MPI) by 99mTc-tetrofosmin within 6 months. CACS was manually performed on dedicated non-contrast ECG-gated CT scans obtained from SPECT-MPI (reference standard). Additionally, CACS was performed fully automatically with a user-independent DL-CACS tool on non-contrast, free-breathing, non-gated CT scans from 18F-FDG-PET/CT examinations. Image quality and noise of CT scans was assessed. Agatston scores obtained by manual CACS and DL tool were compared. The high CACS group had Agatston scores of 2200 ± 1620 (reference standard) and 1300 ± 1011 (DL tool, average underestimation of 38.6 ± 26%) with an intraclass correlation of 0.714 (95% CI 0.546, 0.827). Sufficient image quality significantly improved the DL tool's capability of correctly assigning Agatston scores ≥ 1000 (p = 0.01). In the control group, the DL tool correctly assigned Agatston scores < 1000 in all cases. In conclusion, DL-based CACS performed on non-contrast free-breathing, non-gated CT scans from 18F-FDG-PET/CT examinations of patients with known very high (≥ 1000) CAC underestimates CAC load, but correctly assigns an Agatston scores ≥ 1000 in over 70% of cases, provided sufficient CT image quality. Subgroup analyses of the control group showed that the DL tool does not generate false-positives.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Hipercalcemia , Humanos , Vasos Coronários/diagnóstico por imagem , Cálcio , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Doença da Artéria Coronariana/diagnóstico por imagem , Cálcio da Dieta
20.
Sci Rep ; 12(1): 5915, 2022 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-35396525

RESUMO

Our aim is to define the capabilities of radiomics and machine learning in predicting pseudoprogression development from pre-treatment MR images in a patient cohort diagnosed with high grade gliomas. In this retrospective analysis, we analysed 131 patients with high grade gliomas. Segmentation of the contrast enhancing parts of the tumor before administration of radio-chemotherapy was semi-automatically performed using the 3D Slicer open-source software platform (version 4.10) on T1 post contrast MR images. Imaging data was split into training data, test data and an independent validation sample at random. We extracted a total of 107 radiomic features by hand-delineated regions of interest (ROI). Feature selection and model construction were performed using Generalized Boosted Regression Models (GBM). 131 patients were included, of which 64 patients had a histopathologically proven progressive disease and 67 were diagnosed with mixed or pure pseudoprogression after initial treatment. Our Radiomics approach is able to predict the occurrence of pseudoprogression with an AUC, mean sensitivity, mean specificity and mean accuracy of 91.49% [86.27%, 95.89%], 79.92% [73.08%, 87.55%], 88.61% [85.19%, 94.44%] and 84.35% [80.19%, 90.57%] in the full development group, 78.51% [75.27%, 82.46%], 66.26% [57.95%, 73.02%], 78.31% [70.48%, 84.19%] and 72.40% [68.06%, 76.85%] in the testing group and finally 72.87% [70.18%, 76.28%], 71.75% [62.29%, 75.00%], 80.00% [69.23%, 84.62%] and 76.04% [69.90%, 80.00%] in the independent validation sample, respectively. Our results indicate that radiomics is a promising tool to predict pseudo-progression, thus potentially allowing to reduce the use of biopsies and invasive histopathology.


Assuntos
Glioma , Aprendizado de Máquina , Glioma/diagnóstico por imagem , Glioma/terapia , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos