Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 549
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(6): 917-923, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38605682

RESUMO

The advent of excimer laser coronary atherectomy (ELCA) nearly four decades ago heralded a novel way to treat complex lesions, both coronary and peripheral, which were previously untraversable and thus untreatable. These complex lesions include heavily calcified lesions, ostial lesions, bifurcation lesions, chronic total occlusions, in-stent restenosis (including stent underexpansion), and degenerative saphenous vein grafts. We discuss the technology of ELCA, its indications, applications, and complications, and suggest the "MAXCon ELCA" technique for better outcomes without increased risk. Lastly, we present a case of MAXCon ELCA effectively treating a complex lesion.


Assuntos
Aterectomia Coronária , Angiografia Coronária , Doença da Artéria Coronariana , Lasers de Excimer , Humanos , Meios de Contraste , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Lasers de Excimer/uso terapêutico , Solução Salina/administração & dosagem , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 104(1): 125-133, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38769727

RESUMO

BACKGROUND: The Evolut self-expanding valve (SEV) systems (Medtronic), were designed to accommodate varying valve sizes and reduce paravalvular leak (PVL) while maintaining a low delivery profile. These systems have evolved between product generations, alongside valve deployment techniques changing over time. AIMS: This study aimed to examine whether these changes impacted clinical outcomes. METHODS: EPROMPT is a prospective, investigator-initiated, postmarketing registry of consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) using the Evolut PRO/PRO+ SEV system. A total of 300 patients were divided into three consecutive cohorts of 100 patients according to implantation date (January to October 2018, November 2018 to July 2020, and August 2020 to November 2021). Procedural and clinical outcomes over these time periods were compared. RESULTS: Valve Academic Research Consortium (VARC)-2 device implantation success improved over time (70.0% vs. 78.0% vs. 88.8%, p = 0.01), with a similar trend for VARC-3 device success (94.7% vs. 81.7% vs. 96.8%, p < 0.001). PVL (all degrees) frequency was likewise reduced over time (31.0% vs. 17.0% vs. 19.2%, p = 0.04). Furthermore, a trend was noticed toward shorter procedure times and shorter length of stay. However, postprocedural pacemaker implantation rates did not significantly differ (15.2% vs. 21.1% vs. 14.0%, p = 0.43). CONCLUSION: During a 3-year period, we demonstrated better TAVR outcomes with newer SEV iterations, alongside changes in implantation techniques, which might result in better procedural and clinical outcomes. However, we did not see a significant change in peri-procedural pacemaker rates for SEV.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Estudos Prospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Fatores de Risco , Recuperação de Função Fisiológica , Vigilância de Produtos Comercializados , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Hemodinâmica
3.
Curr Cardiol Rep ; 25(4): 213-227, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36847990

RESUMO

PURPOSE OF REVIEW: Cardiogenic shock (CS) is a complex clinical entity that continues to carry a high risk of mortality. The landscape of CS management has changed with the advent of several temporary mechanical circulatory support (MCS) devices designed to provide hemodynamic support. It remains challenging to understand the role of different temporary MCS devices in patients with CS, as many of these patients are critically ill, requiring complex care with multiple MCS device options. Each temporary MCS device can provide different types and levels of hemodynamic support. It is important to understand the risk/benefit profile of each one of them for appropriate device selection in patients with CS. RECENT FINDINGS: MCS may be beneficial in CS patients through augmentation of cardiac output with subsequent improvement of systemic perfusion. Selecting the optimal MCS device depends on several variables including the underlying etiology of CS, clinical strategy of MCS use (bridge to recovery, bridge to transplant or durable MCS, or abridge to decision), amount of hemodynamic support needed, associated respiratory failure, and institutional preference. Furthermore, it is even more challenging to determine the appropriate time to escalate from one MCS device to another or combine different MCS devices. In this review, we discuss the current available data published in the literature on the management of CS and propose a standardized approach for escalation of MCS devices in patients with CS. Shock teams can play an important role to help in hemodynamic-guided management and algorithm-based step-by-step approach in early initiation and escalation of temporary MCS devices at different stages of CS. It is important to define the etiology of CS, and stage of shock and recognize univentricular vs biventricular shock for appropriate device selection and escalation of therapy.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Humanos , Choque Cardiogênico/terapia , Medição de Risco , Hemodinâmica
4.
Catheter Cardiovasc Interv ; 99(3): 822-826, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34480524

RESUMO

OBJECTIVES: To analyze post-marketing surveillance data from the United States Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database for the VASCADE Vascular Closure System (Cardiva Medical Inc., Santa Clara, CA). BACKGROUND: The VASCADE Vascular Closure System is a closure device for femoral arterial and venous access-site closure that was approved by the FDA in 2013. However, post-marketing data and experience on the most commonly reported complications and modes of failure associated with the VASCADE Vascular Closure System are limited. METHODS: Post-marketing surveillance data from the FDA MAUDE database from October 2013 through March 2020 were analyzed, yielding 201 reports. RESULTS: Of the 201 reports of major complications involving VASCADE devices, 156 reports involved either injury (145) or death (11) related to the device. Of the 145 injury reports, bleeding was the most common adverse outcome described (85), followed by pseudoaneurysm (29) and pulselessness of an extremity (21). The device malfunction incidents (41 reports) were reported in three main categories, with deployment failure being the most commonly reported complication. CONCLUSIONS: Our analysis of the MAUDE database demonstrates that in contemporary post-marketing practice, physicians should be well-trained and educated to use the VASCADE closure device because improper utilization is a common cause of device failure, and complications with the VASCADE device can have profound clinical implications.


Assuntos
Artéria Femoral , Marketing , Bases de Dados Factuais , Artéria Femoral/diagnóstico por imagem , Humanos , Resultado do Tratamento , Estados Unidos/epidemiologia , United States Food and Drug Administration
5.
Catheter Cardiovasc Interv ; 100(3): 404-412, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35723247

RESUMO

OBJECTIVES: Evaluate transcatheter heart valve (THV) geometry according to left ventricular outflow tract (LVOT) calcium degree and its impact on hemodynamics and outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a contemporary self-expanding THV. BACKGROUND: LVOT calcium remains challenging for contemporary THVs. LVOT calcium location and degree may affect THV deployment and impact flow patterns and shear stress, accelerating THV degeneration. METHODS: EPROMPT (CoreValve Evolut Pro Prospective Registry; NCT03423459) is a prospective, investigator-initiated, multicenter registry of patients undergoing TAVR using CoreValve Evolut PRO/PRO + THVs. A total of 107 patients were enrolled in EPROMPT's computed tomography (CT) cohort between January 2018 and October 2021. These patients underwent follow-up CT scan 30 days post-TAVR. We analyzed THV geometry and its interaction with the aortic root following deployment using 30-day post-TAVR CT in patients with none/mild versus moderate/severe LVOT calcium. RESULTS: Thirty-day THV inflows were less eccentric in the short axis in patients with none/mild versus moderate/severe LVOT calcium (1.16 ± 0.09 vs. 1.21 ± 0.12; p = 0.007). THV became more circular and was similar between both cohorts at the THV waist (1.08 ± 0.06 vs. 1.09 ± 0.11; p = 0.551), leaflet tips (1.03 ± 0.04 vs. 1.05 ± 0.09; p = 0.299), and THV outflow (1.04 ± 2.2 vs. 1.03 ± 2.7; p = 0.143). Thirty-day > mild paravalvular leak was low in both cohorts (1.5% vs. 2.4%; p = 0.724); mean gradients were similar (7.7 ± 3.6 vs. 7.7 ± 3.4 mmHg; p = 0.955). CONCLUSIONS: Despite inflow deformities observed in patients with moderate/severe LVOT calcium, Evolut PRO/PRO + conforms to elliptical aortic annuli, maintaining circularity and proper function at the leaflets and outflow, even in patients with moderate/severe LVOT calcium.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Cálcio , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 99(3): 896-903, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34505737

RESUMO

OBJECTIVES: We sought to report details of the incidence, organisms, clinical course, and outcomes of prosthetic valve endocarditis (PVE) after transcatheter aortic valve replacement (TAVR) in low-risk patients. BACKGROUND: PVE remains a rare but devastating complication of aortic valve replacement. Data regarding PVE after TAVR in low-risk patients are lacking. METHODS: We performed a detailed review of all patients in the low-risk TAVR trials who underwent TAVR from 2016 to 2020 and were adjudicated to have definitive PVE by the independent Clinical Events Committee. RESULTS: We analyzed 396 low-risk patients who underwent TAVR (including 72 with bicuspid valves). PVE occurred in 11 patients at a median 379 days (210, 528) from TAVR. The incidence within the first 30 days was 0%; days 31-365, 1.5%; and after day 365, 2.8%. The most common organism identified was Streptococcus (n = 4/11). Early PVE (≤ 365 days) occurred in five patients, of whom three demonstrated evidence of embolic stroke and two underwent surgical aortic valve re-intervention. Late PVE (> 365 days) occurred in six patients, of whom thee demonstrated evidence of embolic stroke and only one underwent surgical aortic valve re-intervention. Of the six patients with evidence of embolic stroke, two died, two were discharged to rehabilitation, and two were discharged home with home care. CONCLUSIONS: PVE was infrequent following TAVR in low-risk patients but was associated with substantial morbidity and mortality. Embolic stroke complicated the majority of PVE cases, contributing to worse outcomes in these patients. Efforts must be undertaken to minimize PVE in TAVR.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Endocardite/etiologia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Lancet ; 396(10252): 669-683, 2020 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-32593323

RESUMO

BACKGROUND: Randomised trial data assessing the safety and efficacy of the self-expanding intra-annular Portico transcatheter aortic valve system (Abbott Structural Heart, St Paul, MN, USA) compared with any commercially available valves are needed to compare performance among designs. METHODS: In this prospective, multicentre, non-inferiority, randomised controlled trial (the Portico Re-sheathable Transcatheter Aortic Valve System US Investigational Device Exemption trial [PORTICO IDE]), high and extreme risk patients with severe symptomatic aortic stenosis were recruited from 52 medical centres experienced in performing transcatheter aortic valve replacement in the USA and Australia. Patients were eligible if they were aged 21 years or older, in New York Heart Association functional class II or higher, and had severe native aortic stenosis. Eligible patients were randomly assigned (1:1) using permuted block randomisation (block sizes of 2 and 4) and stratified by clinical investigational site, surgical risk cohort, and vascular access method, to transcatheter aortic valve replacement with the first generation Portico valve and delivery system or a commercially available valve (either an intra-annular balloon-expandable Edwards-SAPIEN, SAPIEN XT, or SAPIEN 3 valve [Edwards LifeSciences, Irvine, CA, USA]; or a supra-annular self-expanding CoreValve, Evolut-R, or Evolut-PRO valve [Medtronic, Minneapolis, MN, USA]). Investigational site staff, implanting physician, and study participant were unmasked to treatment assignment. Core laboratories and clinical event assessors were masked to treatment allocation. The primary safety endpoint was a composite of all-cause mortality, disabling stroke, life-threatening bleeding requiring transfusion, acute kidney injury requiring dialysis, or major vascular complication at 30 days. The primary efficacy endpoint was all-cause mortality or disabling stroke at 1 year. Clinical outcomes and valve performance were assessed up to 2 years after the procedure. Primary analyses were by intention to treat and the Kaplan-Meier method to estimate event rates. The non-inferiority margin was 8·5% for primary safety and 8·0% for primary efficacy endpoints. This study is registered with ClinicalTrials.gov, NCT02000115, and is ongoing. FINDINGS: Between May 30 and Sept 12, 2014, and between Aug 21, 2015, and Oct 10, 2017, with recruitment paused for 11 months by the funder, we recruited 1034 patients, of whom 750 were eligible and randomly assigned to the Portico valve group (n=381) or commercially available valve group (n=369). Mean age was 83 years (SD 7) and 395 (52·7%) patients were female. For the primary safety endpoint at 30 days, the event rate was higher in the Portico valve group than in the commercial valve group (52 [13·8%] vs 35 [9·6%]; absolute difference 4·2, 95% CI -0·4 to 8·8 [upper confidence bound {UCB} 8·1%]; pnon-inferiority=0·034, psuperiority=0·071). At 1 year, the rates of the primary efficacy endpoint were similar between the groups (55 [14·8%] in the Portico group vs 48 [13·4%] in the commercial valve group; difference 1·5%, 95% CI -3·6 to 6·5 [UCB 5·7%]; pnon-inferiority=0·0058, psuperiority=0·50). At 2 years, rates of death (80 [22·3%] vs 70 [20·2%]; p=0·40) or disabling stroke (10 [3·1%] vs 16 [5·0%]; p=0·23) were similar between groups. INTERPRETATION: The Portico valve was associated with similar rates of death or disabling stroke at 2 years compared with commercial valves, but was associated with higher rates of the primary composite safety endpoint including death at 30 days. The first-generation Portico valve and delivery system did not offer advantages over other commercially available valves. FUNDING: Abbott.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Mortalidade , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Austrália , Transfusão de Sangue , Causas de Morte , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/terapia , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/terapia , Diálise Renal , Índice de Gravidade de Doença , Resultado do Tratamento , Estados Unidos
8.
Am Heart J ; 238: 59-65, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33961829

RESUMO

BACKGROUND: To date, there are no real-world studies comparing cangrelor to glycoprotein IIb/IIIa inhibitors (GPI) during percutaneous coronary intervention (PCI). Thus, we performed this study to evaluate the safety and effectiveness of cangrelor compared to GPI during PCI. METHODS: We identified patients who underwent PCI at our institution who received either cangrelor or GPI during PCI. Patients already on GPI or cangrelor prior to PCI or who received both cangrelor and GPI were excluded. Baseline demographics and clinical outcomes were extracted. Major bleeding is defined as a composite of major hematoma >4 cm, hematocrit drop >15, and gastrointestinal bleeding. RESULTS: A total of 2072 patients received adjunctive antiplatelet therapy during PCI (cangrelor [n=478]; GPI [n=1594]). Patients' mean age was 61±12 years. Most (66%) presented with acute coronary syndrome. Patients who received cangrelor were older and had a higher percentage of acute coronary syndrome and lower baseline hematocrit in comparison with patients who received GPI. Procedural success was achieved in 94% of patients, with no difference between groups. Major bleeding events (1.7% vs. 5.1%, P=.001), any vascular complication rates, and hospital length of stay were significantly lower in the cangrelor group. In-hospital ischemic events did not differ between groups. On regression analysis, patients on cangrelor were noted to have significantly lower major bleeding events (OR 0.23; 95% CI, 0.09-0.59). CONCLUSIONS: Balancing ischemic and bleeding risks with adjunctive antiplatelet drugs is of prime importance during PCI. Our real-world analysis shows that cangrelor is safe and effective when compared to GPI during PCI.


Assuntos
Monofosfato de Adenosina/análogos & derivados , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/uso terapêutico , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Síndrome Coronariana Aguda/sangue , Monofosfato de Adenosina/efeitos adversos , Monofosfato de Adenosina/uso terapêutico , Feminino , Hemorragia Gastrointestinal/induzido quimicamente , Hematócrito , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/efeitos adversos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia
9.
Am Heart J ; 231: 25-31, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33091365

RESUMO

Transcatheter aortic valve replacement (TAVR) has evolved toward a minimalist approach, resulting in shorter hospital stays. Real-world trends of next-day discharge (NDD) TAVR are unknown. This study aimed to evaluate underlying trends and readmissions of NDD TAVR. METHODS: This study was derived from the Nationwide Readmissions Database from 2012 to 2016. International Classification of Diseases, Ninth and Tenth Revisions, codes were used to identify patients. Any discharge within 1 day of admission was identified as NDD. NDD TAVR trends over the years were analyzed, and any admissions within 30 days were considered readmissions. A hierarchical logistic regression model was used to identify predictors of readmission. RESULTS: Of 49,742 TAVR procedures, 3,104 were NDD. The percentage of NDD TAVR increased from 1.5% (46/3,051) in 2012 to 12.2% (2,393/19,613) in 2016. However, the 30-day readmission rate remained the same over the years (8.6%). The patients' mean age was 80.3 ±â€¯8.4 years. Major readmission causes were heart-failure exacerbation (16%), infections (9%), and procedural complications (8%). In 2016, there were significantly higher late conduction disorder and gastrointestinal bleeding readmission rates than in 2012-2015. Significant predictors of readmission were anemia, baseline conduction disease, cardiac arrhythmias, heart failure, chronic kidney disease, chronic obstructive pulmonary disease, neoplastic disorders, and discharge to facility. CONCLUSIONS: The percentage of NDD TAVR increased over the years; however, readmission rates remained the same, with a higher rate of conduction abnormality-related hospitalizations in 2016. Careful discharge planning that includes identification of baseline factors that predict readmission and knowledge of etiologies may further prevent 30-day readmissions.


Assuntos
Alta do Paciente/estatística & dados numéricos , Readmissão do Paciente/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso de 80 Anos ou mais , Anemia/epidemiologia , Arritmias Cardíacas/epidemiologia , Bases de Dados Factuais/estatística & dados numéricos , Progressão da Doença , Feminino , Hemorragia Gastrointestinal/epidemiologia , Sistema de Condução Cardíaco , Insuficiência Cardíaca/epidemiologia , Humanos , Infecções/epidemiologia , Modelos Logísticos , Masculino , Alta do Paciente/tendências , Readmissão do Paciente/tendências , Complicações Pós-Operatórias/epidemiologia , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Insuficiência Renal Crônica/epidemiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/tendências , Estados Unidos
10.
Am Heart J ; 237: 25-33, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33713618

RESUMO

BACKGROUND: Previous studies from the Low Risk TAVR (LRT) trial demonstrated that transcatheter aortic valve replacement (TAVR) is safe and feasible in low-risk patients, with excellent 30-day and 1-year outcomes. The objective of this study was to report clinical outcomes and the impact of 30-day hypoattenuated leaflet thickening (HALT) on structural valve deterioration (SVD) 2 years after TAVR. METHODS: The LRT trial was the first Food and Drug Administration-approved Investigational Device Exemption trial in the United States to evaluate the safety and feasibility of TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis (AS). Valve hemodynamics and SVD by echo were recorded 30 days, 1 year, and 2 years post-TAVR. RESULTS: The LRT trial enrolled 200 low-risk patients to receive TAVR. Their mean age was 73.6 years and 61.5% were men. At 2-year follow-up, the mortality rate was 4.2%; the cardiovascular death rate was 1.6%. The disabling stroke rate was 1.1%, permanent pacemaker implantation rate was 8.6%, and 4 patients (2.2%) presented with endocarditis (2 between years 1 and 2). Of the 14% of TAVR subjects who had evidence of HALT at 30 days, there was no impact on valve hemodynamics, endocarditis or stroke at 2 years. CONCLUSIONS: TAVR for low-risk patients with symptomatic severe tricuspid AS is safe at 2 years. The presence of HALT at 30 days did not impact the early hemodynamic improvements nor the durability of the valve structure.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Estudos de Viabilidade , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 98(3): 580-585, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34051039

RESUMO

OBJECTIVE: Compare two large-bore vascular closure devices (VCDs), collagen-plug-based MANTA and suture-based dual Perclose ProGlide (PP), in patients undergoing contemporary transfemoral transcatheter aortic valve replacement (TAVR). BACKGROUND: The SAFE MANTA IDE clinical trial demonstrated that the collagen-plug-based MANTA VCDs were safe and effective in closing large-bore arteriotomies. However, data comparing this collagen-plug-based VCD to the suture-based VCD in contemporary practice are sparse. METHODS: This was a retrospective observational study in which we screened transfemoral (TF) TAVR patients at our institution from 2017 to 2020. Included were those whose large-bore TF access was closed using either MANTA or PP with and without Angio-Seal. Our primary outcome was VCD success. Additional in-hospital outcomes included major and minor vascular complications, post-TAVR length of stay, and mortality. RESULTS: We screened 696 patients who underwent TAVR. Using propensity scores, we matched 124 patients who received MANTA with 124 patients who received PP. Patients had a mean age of 77.2 years, 69.0% were men, and their mean Society of Thoracic Surgeons score was 3.4%. VCD success was equivalent between VCDs (95.2% vs. 95.2%; p = 1.000). Patients had similar rates of mortality (0% vs. 0.8%; p = .316), and no patients had major vascular complications. CONCLUSIONS: In contemporary TAVR, the collagen-plug-based MANTA VCD appears to be as safe and effective as the suture-based dual PP VCD, with no differences in VCD success, vascular complications, or mortality. Therefore, selection of VCD for TAVR should be left to operator discretion, taking into account anatomical considerations.


Assuntos
Estenose da Valva Aórtica , Cateterismo Periférico , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 97(7): 1379-1385, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33063926

RESUMO

OBJECTIVES: We compared access-site complications with a Micropuncture 21-gauge (G) needle to a standard 18G needle in patients undergoing femoral-access percutaneous coronary intervention (PCI). BACKGROUND: Vascular access-site complications are the most common complication after cardiac catheterization. These complications increase patient morbidity and mortality, along with healthcare costs. METHODS: We retrospectively analyzed a cohort of 17,844 consecutive patients undergoing PCI. Micropuncture access was used in 2344 patients and a standard 18G needle in 15,500 patients. Primary endpoints included vascular perforation or limb ischemia requiring repair, retroperitoneal bleeding, pseudoaneurysm, arteriovenous fistula, groin hematoma (>4 cm). RESULTS: Patients undergoing PCI with Micropuncture were at higher risk: they were on anticoagulation (557 [23.7%] vs. 1,590 [10.2%], p < .001), used steroids more frequently (131 [5.6%] vs. 638 [4.1%], p < .001) and required the use of an intra-aortic balloon pump more often (191 [(8.1%] vs. 896 [5.7%], p < .001). Overall, the access-site complications rate was lower using Micropuncture (58 [2.5%]) versus standard needle (558 [3.6%], p = .005). The Micropuncture group had a significantly lower rate of hematoma than standard needle (32 [1.4%] vs. 309 [1.9%], p = .03). There was no significant difference in the rate of limb ischemia (1 [0.04%] vs. 12 [0.07%], p = .56), perforation (2 [0.08%] vs. 14 [0.09%], p = .93), retroperitoneal bleeding (3 [0.12%] vs. 18 [0.11%], p = .87), pseudoaneurysm (18 [0.76%] vs. 170 [1.09%], p = .14), and arteriovenous fistula (2 [0.08%] vs. 35 [0.22%], p = .16), comparing the Micropuncture group to a standard needle, respectively. CONCLUSIONS: Femoral access using a Micropuncture reduced the rate of vascular complications with significant reduction in the rate of groin hematomas.


Assuntos
Intervenção Coronária Percutânea , Artéria Femoral/diagnóstico por imagem , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Punções , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 98(3): 572-577, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33539651

RESUMO

OBJECTIVES: We analyzed post-marketing surveillance data from the United States Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database for suture-based vascular closure devices (VCDs) - Perclose ProGlide (Abbott, Chicago, Illinois) and Prostar XL (Abbott). BACKGROUND: Suture-based VCDs are mostly used for large-bore femoral arterial access-site closure. Real-world, contemporary experience on the most commonly reported complications and modes of failure associated with these devices is limited. METHODS: Post-marketing surveillance data from the FDA MAUDE database, for the ProGlide system and for the Prostar XL system, were analyzed, yielding 827 Perclose ProGlide reports and 175 Prostar XL reports. RESULTS: Of the 827 reports of major complications involving the Perclose ProGlide devices, 404 reports involved injury, and one involved death related to the device. In the Prostar XL analysis, 94 reports involved injury, and one involved death. Bleeding from vessel injury was the most common adverse outcome described with both devices, followed by hematoma and thrombus. Surgical repair was the most commonly used treatment strategy. In terms of device malfunction, suture-related malfunction (212 reports) was most commonly seen in the Perclose ProGlide group, while failed deployment was most commonly seen in the Prostar XL group. CONCLUSIONS: Our analysis of the MAUDE database demonstrates that in real-world practice, suture-based VCDs were found to be associated with complications, including vascular injury, difficulties with the device itself, and even death. Ongoing user education and pre-procedural patient selection are important to minimize risks associated with suture-based vascular closure devices.


Assuntos
Dispositivos de Oclusão Vascular , Artéria Femoral/cirurgia , Humanos , Suturas , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration
14.
Echocardiography ; 38(5): 752-759, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33835611

RESUMO

BACKGROUND: Pericardial effusion drainage in patients with significant pulmonary hypertension (PH) has been questioned because of hemodynamic collapse concern, mainly because of right ventricular (RV) function challenging assessment. We aimed to assess RV function changes related to pericardiocentesis in patients with and without PH. METHODS: Consecutive patients with symptomatic moderate-to-large pericardial effusion who had either echocardiographic or clinical signs of cardiac tamponade and who underwent pericardiocentesis from 2013 to 2018 were included. RV speckle-tracking echocardiography analysis was performed before and after pericardiocentesis. Patients were stratified by significant PH (pulmonary artery systolic pressure [PASP] ≥50 mm Hg). RESULTS: The study cohort consisted of 76 patients, 23 (30%) with PH. In patients with PH, both end-diastolic and end-systolic areas (EDA, ESA) increased significantly after pericardiocentesis (22.6 ± 8.0 cm2 -26.4 ± 8.4 cm2 , P = .01) and (15.9 ± 6.3 cm2 -18.7 ± 6.5 cm2 , P = .02), respectively. However, RV function indices including fractional area change (FAC: 30.6 ± 13.7%-29.1 ± 8.8%, P = .61) and free-wall longitudinal strain (FWLS: -16.7 ± 6.7 to -15.9 ± 5.0, P = .50) remained unchanged postpericardiocentesis. In contrast, in the non-PH group, after pericardiocentesis, EDA increased significantly (20.4 ± 6.2-22.4 ± 5.9 cm2 , P = .006) but ESA did not (14.9 ± 5.7 vs 15.0 ± 4.6 cm2 , P = .89), and RV function indices improved (FAC 27.9 ± 11.7%-33.1 ± 8.5%, P = .003; FWLS -13.6 ± 5.4 to -17.2 ± 3.9%, P < .001). CONCLUSION: Quantification of RV size and function can improve understanding of echocardiographic and hemodynamic changes postpericardiocentesis, which has the potential to guide management of PH patients with large pericardial effusion.


Assuntos
Hipertensão Pulmonar , Disfunção Ventricular Direita , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico por imagem , Pericardiocentese , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Função Ventricular Direita
15.
Am Heart J ; 221: 74-83, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31951847

RESUMO

BACKGROUND: Clinical data support the use of intravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) as being associated with improved outcomes. Nonetheless, global utilization of IVUS remains low. We hypothesize that, in the revascularization of complex lesions, IVUS use is associated with improved outcomes. METHODS: All patients with complex lesions treated with PCI at a single center from 2003 to 2016 were stratified by use of IVUS. Complex lesions were defined as follows: American College of Cardiology/American Heart Association type C lesions, in-stent restenosis, long lesions, bifurcations, severe calcification, left main lesions, and chronic total occlusions. The primary end point was the rate of major adverse cardiac events (MACE) at 1-year follow-up, defined as the composite of all-cause mortality, Q-wave myocardial infarction, and target vessel revascularization. Inverse probability weighting was used in the adjusted analysis. RESULTS: A total of 6,855 patients were included in the final analysis, of whom 67.3% had IVUS and 32.7% had angiography alone. The primary end point occurred in 13.4% of patients treated with IVUS and 18.3% of patients treated with angiography alone (P < .001). Inverse probability weighting-adjusted 1-year MACE rates demonstrated significant reduction with IVUS for each complex lesion type. CONCLUSIONS: Among patients with complex lesions, the use of IVUS was associated with lower MACE 1 year after PCI than angiography alone was. Because of the increased procedural risk in complex lesions, routine utilization of IVUS-guided PCI should be considered in this subset of patients.


Assuntos
Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Aterectomia Coronária , Angiografia Coronária , Stents Farmacológicos , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Stents , Cirurgia Assistida por Computador/métodos
16.
Catheter Cardiovasc Interv ; 93(7): 1236, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31172680

RESUMO

The DyeVert Plus system is a unique device that reduces contrast volume without sacrificing image quality. Important components to reduce acute kidney injury include volume expansion, contrast reduction, and screening for risk. Operators can make a conscious effort to limit contrast volume by limiting angiography to one cine run per vessel.


Assuntos
Injúria Renal Aguda , Meios de Contraste , Angiografia Coronária , Humanos , Rim , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 93(3): 555-558, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30378244

RESUMO

Transcatheter aortic valve replacement has become a mainstay alternative to surgical aortic valve replacement in patients with severe aortic stenosis at high and intermediate surgical risk. Two commercially approved valves are available in the United States: balloon-expandable and self-expanding. We report here a rare complication of a self-expanding Evolut PRO (Medtronic, Minneapolis, Minnesota) valve failing to expand due to nitinol frame infolding. This results in a malopposed valve with a severe paravalvular leak, even though treated successfully with balloon valvuloplasty. It is important to recognize the characteristic angiographic signature of this complication-the "straight line" sign-and how to avoid this potentially serious complication by balloon valvuloplasty or by recapture and deployment of a new valve.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Ligas , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/terapia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Feminino , Hemodinâmica , Humanos , Desenho de Prótese , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 93(4): 620-625, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30280475

RESUMO

OBJECTIVES: To compare coronary revascularization appropriateness for non-acute coronary syndrome cases under the 2017 update vs the 2012 appropriate use criteria (AUC). BACKGROUND: In 2017, the 2012 AUC for coronary revascularization were updated. We examined how applying these new 2017 updates to our previous inappropriate cases would change their appropriateness. METHODS: We identified 50 cases of patients who underwent coronary revascularization for stable ischemic heart disease who were deemed inappropriate under the 2012 AUC. Two separate physicians reviewed the cases and applied a new AUC based on the 2017 AUC. Next, if there was a change, the reason was identified. RESULTS: Average age was 64, majority being male (29; 58%). Forty-two (84%) were asymptomatic upon presentation. Most cases (27, 54%) dealt with percutaneous coronary intervention (PCI) of the right coronary artery. After applying the 2017 AUC, 34 of the 50 inappropriate failures (68%) would be changed from "inappropriate" to "may be appropriate care." Of the 34 cases, 25 (73.5%) were changed due to the new AUC no longer expecting the patient to be on ≥2 anti-angina medications prior to PCI. Of the 34 cases, eight (23.5%) were changed due to the new AUC expanding the use of non-invasive modalities. CONCLUSIONS: Applying the 2017 AUC led to a statistically higher number of cases being deemed "may be appropriate." The most common cause for the change included the change in requirement for anti-angina regimen and the expanded role of non-invasive modalities.


Assuntos
Tomada de Decisão Clínica , Definição da Elegibilidade/normas , Fidelidade a Diretrizes/normas , Isquemia Miocárdica/terapia , Seleção de Pacientes , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto/normas , Padrões de Prática Médica/normas , Idoso , Técnicas de Apoio para a Decisão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
19.
Catheter Cardiovasc Interv ; 93(4): 707-712, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30280469

RESUMO

OBJECTIVES: The aim of this study was to determine the prognostic value of contractile reserve (CR) at baseline in patients with low-flow, low-gradient severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Patients with severe AS, left ventricular dysfunction, and low transaortic gradient are at high risk for mortality during surgical aortic valve replacement (SAVR). Furthermore, patients without CR have been shown to have perioperative mortality comparable to that of patients treated medically for severe AS. METHODS: We retrospectively analyzed patients who underwent TAVR with a diagnosis of low-gradient severe AS (mean transvalvular aortic gradient < 40 mmHg, LVEF < 50%, and AVA ≤ 1.0 cm2 or AVAi ≤ 0.6 cm2 ) and who had a pre-TAVR dobutamine stress echocardiogram (DSE). Patients were stratified by the presence or absence of CR, defined as an increase in stroke volume ≥ 20% during DSE. RESULTS: From 2008 to 2016, 61 patients with low-gradient severe AS underwent TAVR and had pre-TAVR DSE. CR was present in 31 patients (51%) and absent in 30 (49%). There was no significant difference between the two groups in baseline demographics, medical history, access site, or types of valves. All-cause mortality was similar in both groups at 30 days (13% with CR vs 10% without CR, P = 1.00) and 1 year (29% with CR vs 33% without CR, HR 1.20, 95% CI 0.49-2.96, P = 0.69). CONCLUSION: In patients with low-flow, low-gradient severe AS undergoing TAVR, the presence or absence of CR does not predict all-cause mortality at 30 days or 1 year.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Hemodinâmica , Contração Miocárdica , Substituição da Valva Aórtica Transcateter/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade
20.
Am Heart J ; 196: 74-81, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29421017

RESUMO

BACKGROUND: Clinical indications for transcatheter aortic valve replacement (TAVR) and elements of the implantation procedure, including delivery system miniaturization and novel access options, have evolved over time. The reasons patients are excluded from TAVR also have changed. The impact of these changes on patient referral for and exclusion from TAVR is unknown. METHODS: We retrospectively analyzed patients referred to our center for TAVR from January 2010 to August 2016 to evaluate reasons for patient exclusion. Patients were divided into three groups based on initial screening date for trends in demographics and exclusion: Group 1, 2010-2012; Group 2, 2012-2014; Group 3, 2014 to August 1, 2016. Annual trends for patient exclusion from TAVR were assessed. RESULTS: One thousand nine hundred fifty-three patients were referred and underwent screening for TAVR. The rates at which patients were referred for TAVR were 23.8, 25.9, and 24.5 per month in groups 1, 2, and 3, respectively. Rate of patient exclusion from TAVR decreased from 68% in Group 1 to 38% in Group 3 (P < .001). The largest percentage of patients (29.4%) were initially excluded from TAVR for cardiac reasons, but this trend has decreased over time. Twenty-five percent are excluded for lack of procedural indication. Exclusion from TAVR for vascular access reasons decreased from 7.9% in 2010 to 1.0% in 2016 (P = .017). CONCLUSIONS: Referral numbers have been robust since TAVR became available. The percentage of patients excluded from TAVR has decreased over time. Patients are most commonly excluded from TAVR for concomitant coronary artery disease (CAD), asymptomatic severe AS, moderate AS, or non-cardiac critical illness. Patients with CAD and those with asymptomatic severe AS or moderate AS should be a focus for continued research in TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Hospitais com Alto Volume de Atendimentos/tendências , Seleção de Pacientes , Encaminhamento e Consulta/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Feminino , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Medição de Risco , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA