1.
Z Med Phys ; 29(4): 368-371, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30528414

RESUMO

This addendum provides correction factors for the recombination and the polarity effect for the new ionization chamber PTW PinPoint (type 31023). The measurements were made in filtered (WFF) and unfiltered (FFF) high-energy photon beams. It could be confirmed that both the initial and the general recombination effect of the chamber mainly depends on dose per pulse at the point of measurement and is independent of the filtration of the photon beam.


Assuntos
Terapia com Prótons/métodos , Radiometria , Humanos , Dosagem Radioterapêutica
2.
Z Med Phys ; 28(3): 247-253, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29336934

RESUMO

The aim of this technical communication is to provide correction factors for recombination and polarity effect for two new ionization chambers PTW PinPoint 3D (type 31022) and PTW Semiflex 3D (type 31021). The correction factors provided are for the (based on the) German DIN 6800-2 dosimetry protocol and the AAPM TG51 protocol. The measurements were made in filtered and unfiltered high-energy photon beams in a water equivalent phantom at maximum depth of the PDD and a field size on the surface of 10cm×10cm. The design of the new chamber types leads to an ion collection efficiency and a polarity effect that are well within the specifications requested by pertinent dosimetry protocols including the addendum of TG-51. It was confirmed that the recombination effect of both chambers mainly depends on dose per pulse and is independent of the filtration of the photon beam.


Assuntos
Radiometria/instrumentação , Radiometria/métodos , Fótons
3.
Z Med Phys ; 25(2): 186-91, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24973310

RESUMO

For the determination of absorbed dose to water D,using thermolumeniscence (TL) probes in a beam different from that used for calibration, correction factors for radiation type and radiation quality kE and kQ are needed. Values for kE and kQ for two different shapes of LiF probes (rods and disks) were obtained for high-energy photon and electron beams. The relation between the absorbed dose to the medium (water) D, measured by ion-chambers according to DIN 6800-2, 2008 and TL-probes having a (60)Co-calibration factor, leads for each shape and each batch of LiF probes to correction factors for radiation type and radiation quality kE and kQ.. The influence of the shape on the correction factor of the probes amounts in our experiment up to 2%. Therefore, it is recommended that the correction factors kE and kQ for rods and disks should be checked for each batch of LiF-detectors.


Assuntos
Artefatos , Elétrons , Fluoretos/efeitos da radiação , Compostos de Lítio/efeitos da radiação , Fótons , Radioterapia de Alta Energia/métodos , Dosimetria Termoluminescente/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
4.
Z Med Phys ; 12(4): 260-7, 2002.
Artigo em Alemão | MEDLINE | ID: mdl-12575440

RESUMO

Long-term observations of mechanical parameters have been performed in Freiburg for the last 7 years within the quality assurance of stereotactic irradiation at linear accelerators. The deviations between the laser indication and the position of the beam isocentre are recorded, as well as parameters for the stability of the couch rotation and the additional devices for patient adjustment and beam collimation. The deviations are used for the correction of the calculated isocentre coordinates. The long-term observation of the measured values and their standard deviations allow conclusions about the quality of the measuring procedure itself, the laser adjustment, the extension of the isocentre sphere, as well as the mechanical slackness of the treatment couch and the fixation device of the stereotactic ring. The standard deviations of the isocentre position were within 0.3 to 0.8 mm, those of the measurement quality approximately 0.2 mm. The analysis of long-term observation has contributed to improvements of the equipment and of quality assurance procedures.


Assuntos
Aceleradores de Partículas , Radiocirurgia/normas , Calibragem , Humanos , Lasers , Garantia da Qualidade dos Cuidados de Saúde , Radiocirurgia/métodos
SELEÇÃO DE REFERÊNCIAS