RESUMO
BACKGROUND: High quality endoscopy is key for detecting and removing precursor lesions to colorectal cancer (CRC). Adenoma detection rates (ADRs) measure endoscopist performance. Improving other components of examinations could increase adenoma detection. AIMS: To investigate how endoscopist performance at flexible sigmoidoscopy (FS) affects adenoma detection and CRC incidence. METHODS: Among 34,139 participants receiving FS screening by the main endoscopist at one of 13 centres in the UK FS Screening Trial, median follow-up was 17 years. Factors examined included family history of CRC, bowel preparation quality, insertion and withdrawal time, bowel segment reached, patient pain and ADR. Odds ratios (OR) for distal adenoma detection were estimated by logistic regression. Hazard ratios (HR) for distal CRC incidence were estimated by Cox regression. RESULTS: At screening, 4,104 participants had distal adenomas detected and 168 participants developed distal CRC during follow-up. In multivariable models, a family history of CRC (yes vs. no: OR 1.40, 95%CI 1.21-1.62), good or adequate bowel preparation quality (vs. excellent: OR 0.84, 95%CI 0.74-0.95; OR 0.56, 95%CI 0.49-0.65, respectively) and longer insertion and withdrawal times (≥ 4.00 vs. < 2.00 min: OR 1.96, 95%CI 1.68-2.29; OR 32.79, 95%CI 28.22-38.11, respectively) were associated with adenoma detection. Being screened by endoscopists with low or intermediate ADRs, compared to high ADRs, was positively associated with CRC incidence (multivariable: HR 4.71, 95%CI 2.65-8.38; HR 2.16, 95%CI 1.22-3.81, respectively). CONCLUSIONS: Bowel preparation quality and longer insertion and withdrawal time are key for improving distal adenoma detection. Higher ADRs were associated with a lower risk of distal CRC.
Assuntos
Adenoma , Neoplasias Colorretais , Humanos , Incidência , Razão de Chances , Dor , Ensaios Clínicos como Assunto , Estudos Multicêntricos como AssuntoRESUMO
BACKGROUND AND AIMS: Advances in endoscopic technology, such as narrow-band imaging and high-definition colonoscopes, offer the potential for optical diagnosis (OD) with a "resect and discard" (RD) strategy for diminutive (≤5 mm) and small (6-9 mm) colorectal polyps. This could help alleviate the huge cost and time burden required for histopathology. The aim of this study was to conduct an economic analysis of an RD strategy within the English Bowel Cancer Screening Programme (BCSP). METHODS: A decision tree was designed to compare an RD strategy with standard histopathology for patients included in the DISCARD3 study (Detect InSpect ChAracterise Resect and Discard 3) and was extrapolated to a national BCSP patient cohort. RESULTS: Of the 525 patients in the DISCARD3 study, 354 were assessed for surveillance intervals (after excluding cases with colorectal cancer and at least 1 polyp >10 mm). Of 354 patients, 269 had polyps, of which 182 had only diminutive polyps, 77 had both small and diminutive polyps, and 10 had only small polyps. Surveillance interval concordance was 97.9% in patients with at least 1 diminutive polyp and 98.7% in patients with at least 1 diminutive or small polyp. In DISCARD3, an RD approach was found to reduce overall direct healthcare costs by $44,285.63 (-72.3%) for patients with diminutive polyps or by $66,129.13 (-75.0%) for patients with diminutive or small polyps. When extrapolated to the entire English BCSP, the annual savings were almost $3 million for patients with diminutive polyps or $4.3 million for patients with diminutive or small polyps, after adjusting for the costs of an OD quality assurance process. CONCLUSIONS: OD with an RD strategy for diminutive and small polyps during BCSP colonoscopy would offer substantial cost savings without adversely affecting surveillance interval concordance.
Assuntos
Pólipos do Colo , Neoplasias Colorretais , Humanos , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/cirurgia , Detecção Precoce de Câncer/métodos , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Imagem de Banda EstreitaRESUMO
BACKGROUND AND AIMS: Developments in image-enhancing endoscopy and polyp classification systems have led to a number of gastroenterology societies endorsing an optical diagnosis (OD) approach for small polyps at colonoscopy. In this study we performed a root-cause analysis of ODs to determine the most likely causes of OD error. METHODS: As part of a prospective feasibility study, DISCARD3 (Detect InSpect ChAracterise Resect and Discard 3), evaluating implementation and quality assurance of a "resect and discard" strategy for consecutive small polyps <10 mm, a root-cause analysis of 184 cases of high-confidence OD error was performed. In all cases, histopathology underwent a second blinded review and, where discrepancy persisted, further review with deeper levels. RESULTS: After a root-cause analysis, 133 of 184 true OD errors were identified and classified into 4 types: A (OD, adenoma; histology, serrated), 45/133 (33.8%); B (OD, serrated; histology, adenoma), 55/133 (41.4%); C (OD, adenoma; histology, normal), 19/133 (14.3%); and D (OD, serrated; histology, normal), 14/133 (10.5%). The remaining 51 of 184 errors were because of a pathology error requiring deeper levels (43/184), pathology observer or laboratory error (7/184), or other error (1/184). CONCLUSIONS: OD errors can be related to endoscopist-related factors such as poor photodocumentation, failures of current classification systems, and incomplete histology. We identified a subset of serrated polyps frequently misdiagnosed as adenomas ("pseudoadenomas") using the NBI International Colorectal Endoscopic (NICE) classification. An enhanced algorithm for OD is proposed based on the NICE classification including morphologic and adjunct polyp features.
Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Pólipos do Colo/patologia , Estudos Prospectivos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Colonoscopia/métodos , Adenoma/diagnóstico por imagem , Adenoma/patologia , Imagem de Banda Estreita/métodosRESUMO
BACKGROUND: Polyp detection and resection during colonoscopy significantly reduce long-term colorectal cancer risk. Computer-aided detection (CADe) may increase polyp identification but has undergone limited clinical evaluation. Our aim was to assess the effectiveness of CADe at colonoscopy within a bowel cancer screening program (BCSP). METHODS: This prospective, randomized controlled trial involved all eight screening-accredited colonoscopists at an English National Health Service (NHS) BCSP center (February 2020 to December 2021). Patients were randomized to CADe or standard colonoscopy. Patients meeting NHS criteria for bowel cancer screening were included. The primary outcome of interest was polyp detection rate (PDR). RESULTS: 658 patients were invited and 44 were excluded. A total of 614 patients were randomized to CADe (nâ=â308) or standard colonoscopy (nâ=â306); 35 cases were excluded from the per-protocol analysis due to poor bowel preparation (nâ=â10), an incomplete procedure (nâ=â24), or a data issue (nâ=â1). Endocuff Vision was frequently used and evenly distributed (71.7â% CADe and 69.2â% standard). On intention-to-treat (ITT) analysis, there was a borderline significant difference in PDR (85.7â% vs. 79.7â%; Pâ=â0.05) but no significant difference in adenoma detection rate (ADR; 71.4â% vs. 65.0â%; Pâ=â0.09) for CADe vs. standard groups, respectively. On per-protocol analysis, no significant difference was observed in these rates. There was no significant difference in procedure times. CONCLUSIONS: In high-performing colonoscopists in a BCSP who routinely used Endocuff Vision, CADe improved PDR but not ADR. CADe appeared to have limited benefit in a BCSP setting where procedures are performed by experienced colonoscopists.
Assuntos
Pólipos do Colo , Neoplasias Colorretais , Humanos , Pólipos do Colo/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico , Medicina Estatal , Estudos Prospectivos , Colonoscopia/métodos , Detecção Precoce de Câncer/métodos , Computadores , Inteligência ArtificialRESUMO
BACKGROUND & AIMS: Detection and removal of adenomas reduces colorectal cancer (CRC) risk. The impact of adenoma detection rates (ADRs) on long-term CRC incidence and mortality is unknown. We investigated this using data from the UK Flexible Sigmoidoscopy Screening Trial. METHODS: Of 167,882 UK Flexible Sigmoidoscopy Screening Trial participants, 40,085 were in the intervention arm and underwent flexible sigmoidoscopy screening at 13 trial centers. The median follow-up time was 17 years. At each center, 1 endoscopist performed most flexible sigmoidoscopies. Multivariable logistic regression was used to classify centers into high-, intermediate-, and low-detector groups based on their main endoscopist's ADR. We calculated the incidence and mortality of distal and all-site CRC, and estimated hazard ratios (HRs) with 95% CIs using Cox regression. RESULTS: Five, 4, and 4 centers, respectively, were classified into the high-detector, intermediate-detector, and low-detector groups. The average ADRs in each respective group were 15%, 12%, and 9%. Distal CRC incidence and mortality were reduced among those screened compared with controls in all groups, and effects of screening varied significantly by detector ranking, with larger reductions in incidence and mortality seen in the high-detector group (incidence: HR, 0.34; 95% CI, 0.27-0.42; mortality: HR, 0.22, 95% CI, 0.13-0.37) than in the low-detector group (incidence: HR, 0.55; 95% CI, 0.44-0.68; mortality: HR, 0.54; 95% CI, 0.34-0.86). Similar results were observed for all-site CRC, with larger effects seen in the high-detector (incidence: HR, 0.58; 95% CI, 0.50-0.67; mortality: HR, 0.52; 95% CI, 0.39-0.69) than in the low-detector group (incidence: HR, 0.72; 95% CI, 0.61-0.85; mortality: HR, 0.68; 95% CI, 0.51-0.92), although the heterogeneity was not statistically significant. CONCLUSIONS: Higher ADRs at screening provide greater long-term protection against CRC incidence and mortality. Isrctn.org, number: ISRCTN28352761.
Assuntos
Adenoma , Neoplasias Colorretais , Adenoma/diagnóstico , Adenoma/epidemiologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Detecção Precoce de Câncer/métodos , Humanos , Incidência , Modelos Logísticos , Programas de Rastreamento/métodos , SigmoidoscopiaRESUMO
BACKGROUND AND AIMS: Optical diagnosis (OD) of polyps can be performed with advanced endoscopic imaging. For high-confidence diagnoses, a "resect and discard" strategy could offer significant histopathology time and cost savings. The implementation threshold is a ≥90% OD-histology surveillance interval concordance. Here we assessed the OD learning curve and feasibility of a resect and discard strategy for ≤5-mm and <10-mm polyps in a bowel cancer screening setting. METHODS: In this prospective feasibility study, 8 bowel cancer screening endoscopists completed a validated OD training module and performed procedures. All <10-mm consecutive polyps had white-light and narrow-band images taken and were given high- or low-confidence diagnoses until 120 high-confidence ≤5-mm polyp diagnoses had been performed. All polyps had standard histology. High-confidence OD errors underwent root-cause analysis. Histology and OD-derived surveillance intervals were calculated. RESULTS: Of 565 invited patients, 525 patients were included. A total of 1560 <10-mm polyps underwent OD and were resected and retrieved (1329 ≤5 mm and 231 6-9 mm). There were no <10-mm polyp cancers. High-confidence OD was accurate in 81.5% of ≤5-mm and 92.8% of 6-9-mm polyps. Sensitivity for OD of a ≤5-mm adenoma was 93.0% with a positive predictive value of 90.8%. OD-histology surveillance interval concordance for ≤5-mm OD was 91.3% (209/229) for U.S. Multi-Society Task Force, 98.3% (225/229) for European Society of Gastrointestinal Endoscopy, and 98.7% (226/229) for British Society of Gastroenterology guidelines, respectively. CONCLUSIONS: A resect and discard strategy for high-confidence ≤5-mm polyp OD in a group of bowel cancer screening colonoscopists is feasible and safe, with performance exceeding the 90% surveillance interval concordance required for implementation in clinical practice. (Clinical trial registration number: NCT04710693.).
Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Adenoma/diagnóstico por imagem , Adenoma/cirurgia , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/cirurgia , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Estudos ProspectivosRESUMO
BACKGROUND: Longer post-polypectomy surveillance intervals are associated with increased colorectal neoplasia detection at surveillance in some studies. We investigated this association to inform optimal surveillance intervals. METHODS: Patients who underwent colonoscopy and post-polypectomy surveillance at 17 UK hospitals were classified as low/high risk by baseline findings. We compared detection rates of advanced adenomas (≥â10âmm, tubulovillous/villous, high grade dysplasia), high risk findings (HRFs:â≥â2 serrated polyps/[adenomas] of whichâ≥â1 isâ≥â10âmm or has [high grade] dysplasia;â≥â5 serrated polyps/adenomas; or ≥â1 nonpedunculated polypâ≥â20âmm), or colorectal cancer (CRC) at surveillance colonoscopy by surveillance interval (<â18 months, 2, 3, 4, 5, 6 years). Risk ratios (RRs) were estimated using multivariable regression. RESULTS: Of 11â 214 patients, 7216 (64â%) were low risk and 3998 (36â%) were high risk. Among low risk patients, advanced adenoma, HRF, and CRC detection rates at first surveillance were 7.8â%, 3.7â%, and 1.1â%, respectively. Advanced adenoma detection increased with increasing surveillance interval, reaching 9.8â% with a 6-year interval (P trend <â0.001). Among high risk patients, advanced adenoma, HRF, and CRC detection rates at first surveillance were 15.3â%, 10.0â%, and 1.5â%, respectively. Advanced adenoma and CRC detection rates (P trends <â0.001) increased with increasing surveillance interval; RRs (95â% confidence intervals) for CRC were 1.54 (0.68-3.48), 4.44 (1.95-10.08), and 5.80 (2.51-13.40) with 3-, 4-, and 5-year intervals, respectively, versus an interval of <â18 months. CONCLUSIONS: Metachronous neoplasia was uncommon among low risk patients, even with long surveillance intervals, supporting recommendations for no surveillance in these patients. For high risk patients, a 3-year surveillance interval would ensure timely CRC detection.
Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Adenoma/diagnóstico , Adenoma/epidemiologia , Adenoma/cirurgia , Pólipos do Colo/diagnóstico , Pólipos do Colo/epidemiologia , Pólipos do Colo/cirurgia , Colonoscopia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/cirurgia , Humanos , Estudos Retrospectivos , Fatores de RiscoRESUMO
OBJECTIVE: Colonoscopy surveillance aims to reduce colorectal cancer (CRC) incidence after polypectomy. The 2020 UK guidelines recommend surveillance at 3 years for 'high-risk' patients with ≥2 premalignant polyps (PMPs), of which ≥1 is 'advanced' (serrated polyp (or adenoma) ≥10 mm or with (high-grade) dysplasia); ≥5 PMPs; or ≥1 non-pedunculated polyp ≥20 mm; 'low-risk' patients without these findings are instead encouraged to participate in population-based CRC screening. We examined the appropriateness of these risk classification criteria and recommendations. DESIGN: Retrospective analysis of patients who underwent colonoscopy and polypectomy mostly between 2000 and 2010 at 17 UK hospitals, followed-up through 2017. We examined CRC incidence by baseline characteristics, risk group and number of surveillance visits using Cox regression, and compared incidence with that in the general population using standardised incidence ratios (SIRs). RESULTS: Among 21 318 patients, 368 CRCs occurred during follow-up (median: 10.1 years). Baseline CRC risk factors included age ≥55 years, ≥2 PMPs, adenomas with tubulovillous/villous/unknown histology or high-grade dysplasia, proximal polyps and a baseline visit spanning 2-90 days. Compared with the general population, CRC incidence without surveillance was higher among those with adenomas with high-grade dysplasia (SIR 1.74, 95% CI 1.21 to 2.42) or ≥2 PMPs, of which ≥1 was advanced (1.39, 1.09 to 1.75). For low-risk (71%) and high-risk (29%) patients, SIRs without surveillance were 0.75 (95% CI 0.63 to 0.88) and 1.30 (1.03 to 1.62), respectively; for high-risk patients after first surveillance, the SIR was 1.22 (0.91 to 1.60). CONCLUSION: These guidelines accurately classify post-polypectomy patients into those at high risk, for whom one surveillance colonoscopy appears appropriate, and those at low risk who can be managed by non-invasive screening.
Assuntos
Pólipos do Colo/patologia , Pólipos do Colo/cirurgia , Colonoscopia , Neoplasias Colorretais/epidemiologia , Idoso , Feminino , Humanos , Masculino , Vigilância da População , Estudos Retrospectivos , Fatores de Risco , Reino Unido/epidemiologiaRESUMO
OBJECTIVES: The English Bowel Cancer Screening Programme invites 55 year olds for a sigmoidoscopy (Bowel Scope Screening (BSS)), aiming to resect premalignant polyps, thus reducing cancer incidence. A national patient survey indicated higher procedural pain than anticipated, potentially impacting on screening compliance and effectiveness. We aimed to assess whether water-assisted sigmoidoscopy (WAS), as opposed to standard CO2 technique, improved procedural pain and detection of adenomatous polyps. DESIGN: The WASh (Water-Assisted Sigmoidoscopy) trial was a multicentre, single-blind, randomised control trial for people undergoing BSS. Participants were randomised to either receive WAS or CO2 from five sites across England. The primary outcome measure was patient-reported moderate/severe pain, as assessed by patients on a standard Likert scale post procedure prior to discharge. The key secondary outcome was adenoma detection rate (ADR). The costs of each technique were also measured. RESULTS: 1123 participants (50% women, mean age 55) were randomised (561 WAS, 562 CO2). We found no difference in patient-reported moderate/severe pain between WAS and CO2 (14% in WAS, 15% in CO2; p=0.47). ADR was 15% in the CO2 arm and 11% in the WAS arm (p=0.03); however, it remained above the minimum national performance standard in both arms. There was no statistical difference in mean number of adenomas nor overall polyp detection rate. There was negligible cost difference between the two techniques. CONCLUSION: In the context of enema-prepared unsedated screening sigmoidoscopies performed by screening-accredited endoscopists, no difference in patient-reported pain was seen when using either a CO2 or WAS intubation technique. TRIAL REGISTRATION NUMBER: ISRCTN81466870.
Assuntos
Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Sigmoidoscopia/métodos , Água , Inglaterra , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Manejo da Dor , Medição da Dor , Medidas de Resultados Relatados pelo Paciente , Método Simples-Cego , Medicina EstatalRESUMO
OBJECTIVE: Postpolypectomy colonoscopy surveillance aims to prevent colorectal cancer (CRC). The 2002 UK surveillance guidelines define low-risk, intermediate-risk and high-risk groups, recommending different strategies for each. Evidence supporting the guidelines is limited. We examined CRC incidence and effects of surveillance on incidence among each risk group. DESIGN: Retrospective study of 33 011 patients who underwent colonoscopy with adenoma removal at 17 UK hospitals, mostly (87%) from 2000 to 2010. Patients were followed up through 2016. Cox regression with time-varying covariates was used to estimate effects of surveillance on CRC incidence adjusted for patient, procedural and polyp characteristics. Standardised incidence ratios (SIRs) compared incidence with that in the general population. RESULTS: After exclusions, 28 972 patients were available for analysis; 14 401 (50%) were classed as low-risk, 11 852 (41%) as intermediate-risk and 2719 (9%) as high-risk. Median follow-up was 9.3 years. In the low-risk, intermediate-risk and high-risk groups, CRC incidence per 100 000 person-years was 140 (95% CI 122 to 162), 221 (195 to 251) and 366 (295 to 453), respectively. CRC incidence was 40%-50% lower with a single surveillance visit than with none: hazard ratios (HRs) were 0.56 (95% CI 0.39 to 0.80), 0.59 (0.43 to 0.81) and 0.49 (0.29 to 0.82) in the low-risk, intermediate-risk and high-risk groups, respectively. Compared with the general population, CRC incidence without surveillance was similar among low-risk (SIR 0.86, 95% CI 0.73 to 1.02) and intermediate-risk (1.16, 0.97 to 1.37) patients, but higher among high-risk patients (1.91, 1.39 to 2.56). CONCLUSION: Postpolypectomy surveillance reduces CRC risk. However, even without surveillance, CRC risk in some low-risk and intermediate-risk patients is no higher than in the general population. These patients could be managed by screening rather than surveillance.
Assuntos
Adenoma , Neoplasias do Colo , Pólipos do Colo , Colonoscopia , Neoplasias Colorretais , Risco Ajustado , Adenoma/patologia , Adenoma/cirurgia , Idoso , Neoplasias do Colo/patologia , Neoplasias do Colo/cirurgia , Pólipos do Colo/patologia , Pólipos do Colo/cirurgia , Colonoscopia/métodos , Colonoscopia/estatística & dados numéricos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Detecção Precoce de Câncer/métodos , Detecção Precoce de Câncer/estatística & dados numéricos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Risco Ajustado/métodos , Risco Ajustado/organização & administração , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Fatores de Risco , Reino Unido/epidemiologiaRESUMO
These consensus guidelines were jointly commissioned by the British Society of Gastroenterology (BSG), the Association of Coloproctology of Great Britain and Ireland (ACPGBI) and Public Health England (PHE). They provide an evidence-based framework for the use of surveillance colonoscopy and non-colonoscopic colorectal imaging in people aged 18 years and over. They are the first guidelines that take into account the introduction of national bowel cancer screening. For the first time, they also incorporate surveillance of patients following resection of either adenomatous or serrated polyps and also post-colorectal cancer resection. They are primarily aimed at healthcare professionals, and aim to address:Which patients should commence surveillance post-polypectomy and post-cancer resection?What is the appropriate surveillance interval?When can surveillance be stopped? two or more premalignant polyps including at least one advanced colorectal polyp (defined as a serrated polyp of at least 10 mm in size or containing any grade of dysplasia, or an adenoma of at least 10 mm in size or containing high-grade dysplasia); or five or more premalignant polyps The Appraisal of Guidelines for Research and Evaluation (AGREE II) instrument provided a methodological framework for the guidelines. The BSG's guideline development process was used, which is National Institute for Health and Care Excellence (NICE) compliant.two or more premalignant polyps including at least one advanced colorectal polyp (defined as a serrated polyp of at least 10 mm in size or containing any grade of dysplasia, or an adenoma of at least 10 mm in size or containing high-grade dysplasia); or five or more premalignant polyps The key recommendations are that the high-risk criteria for future colorectal cancer (CRC) following polypectomy comprise either:two or more premalignant polyps including at least one advanced colorectal polyp (defined as a serrated polyp of at least 10 mm in size or containing any grade of dysplasia, or an adenoma of at least 10 mm in size or containing high-grade dysplasia); or five or more premalignant polyps This cohort should undergo a one-off surveillance colonoscopy at 3 years. Post-CRC resection patients should undergo a 1 year clearance colonoscopy, then a surveillance colonoscopy after 3 more years.
Assuntos
Pólipos do Colo/cirurgia , Neoplasias Colorretais/cirurgia , Vigilância da População/métodos , Colonoscopia/normas , Medicina Baseada em Evidências/métodos , Humanos , Assistência de Longa Duração/métodos , Assistência de Longa Duração/normas , Recidiva Local de Neoplasia/diagnóstico , Seleção de Pacientes , Período Pós-OperatórioRESUMO
BACKGROUND & AIMS: Adenoma detection rate (ADR) is an important quality assurance measure for colonoscopy. Some studies suggest that narrow-band imaging (NBI) may be more effective at detecting adenomas than white-light endoscopy (WLE) when bowel preparation is optimal. We conducted a meta-analysis of data from individual patients in randomized controlled trials that compared the efficacy of NBI to WLE in detection of adenomas. METHODS: We searched MEDLINE, EMBASE, and Cochrane Library databases through April 2017 for randomized controlled trials that assessed detection of colon polyps by high-definition WLE vs NBI and from which data on individual patients were available. The primary outcome measure was ADR adjusted for bowel preparation quality. Multilevel regression models were used with patients nested within trials, and trial included as a random effect. RESULTS: We collected data from 11 trials, comprising 4491 patients and 6636 polyps detected. Adenomas were detected in 952 of 2251 (42.3%) participants examined by WLE vs 1011 of 2239 (45.2%) participants examined by NBI (unadjusted odds ratio [OR] for detection of adenoma by WLE vs NBI, 1.14; 95% CI, 1.01-1.29; P = .04). NBI outperformed WLE only when bowel preparation was best: adequate preparation OR, 1.07 (95% CI, 0.92-1.24; P = .38) vs best preparation OR, 1.30 (95% CI, 1.04-1.62; P = .02). Second-generation bright NBI had a better ADR than WLE (second-generation NBI OR, 1.28; 95% CI, 1.05-1.56; P = .02), whereas first-generation NBI did not. NBI detected more non-adenomatous polyps than WLE (OR, 1.24; 95% CI, 1.06-1.44; P = .008) and flat polyps than WLE (OR, 1.24; 95% CI, 1.02-1.51; P = .03). CONCLUSIONS: In a meta-analysis of data from individual patients in randomized controlled trials, we found NBI to have a higher ADR than WLE, and that this effect is greater when bowel preparation is optimal.
Assuntos
Adenoma/diagnóstico por imagem , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Imagem de Banda Estreita/métodos , Adenoma/epidemiologia , Catárticos/administração & dosagem , Colonoscopia/estatística & dados numéricos , Neoplasias Colorretais/epidemiologia , Humanos , Imagem de Banda Estreita/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
BACKGROUND AND AIMS: Adenoma miss rate during colonoscopy is directly linked to risk of postcolonoscopy colorectal cancer. One of the reasons for missed adenomas is poor visualization of proximal folds during standard colonoscopy withdrawal. Disposable distal attachments such as the plastic cap and Endocuff (Arc Medical Design, Leeds, UK) that hold back folds appear to improve adenoma detection. The primary aim of this study was to compare adenoma detection rates between Endocuff-assisted colonoscopy (EAC) and cap-assisted colonoscopy (CAC). METHODS: This is a randomized, single-center, tandem colonoscopy trial performed by the same endoscopists on the same day, first with Endocuff Vision (Arc Medical Design, Leeds, UK) followed by cap or vice versa. All procedures were performed by 3 experienced gastroenterology fellows. RESULTS: One hundred fifty-four patients were recruited. Seventy-eight (50.6%) had CAC as their first procedure. Mean patient age was 61 years (male-to-female ratio, 1:1). Adenoma detection rate was significantly higher for EAC when compared to CAC (53% vs 26%, P = .001). Polyp miss rate was significantly lower in EAC (8.4%) compared with CAC (26.1%, P < .001) as was adenoma miss rate (EAC vs CAC, 6%, vs 19%; P = .002) and diminutive adenoma (<5 mm) miss rate in the EAC group (1.8% vs 19.6%, P < .001). However, there was no significant differences in the miss rates for small adenomas (5-9 mm) (3.7% vs 2.9%, P = .69) or adenomas 10 mm or larger (1.6% vs 2.6%, P = .98 ). The mean number of adenomas per procedure was significantly higher with EAC compared with CAC (1.5 vs .8, P < .001). Cecal intubation time was significantly shorter with EAC than CAC (median 6 vs 7 minutes, P = .01). Conversely, withdrawal time (median 10 vs 8 minutes, P = .01) was significantly longer in EAC. CONCLUSIONS: This randomized, tandem study demonstrates that EAC has a significantly higher adenoma detection rate and lower adenoma miss rate than CAC. Although insertion times were shorter with EAC, procedures were slightly more uncomfortable, and the cuff had to be removed in a small number of cases. (Clinical trial registration number: NCT03254498.).
Assuntos
Adenoma , Neoplasias do Colo , Neoplasias Colorretais , Adenoma/diagnóstico , Ceco , Neoplasias do Colo/diagnóstico , Pólipos do Colo/diagnóstico por imagem , Colonoscópios , Colonoscopia , Neoplasias Colorretais/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
OBJECTIVE: Ulcerative colitis (UC) is a dynamic disease with its severity continuously changing over time. We hypothesised that the risk of colorectal neoplasia (CRN) in UC closely follows an actuarial accumulative inflammatory burden, which is inadequately represented by current risk stratification strategies. DESIGN: This was a retrospective single-centre study. Patients with extensive UC who were under colonoscopic surveillance between 2003 and 2012 were studied. Each surveillance episode was scored for a severity of microscopic inflammation (0=no activity; 1=mild; 2=moderate; 3=severe activity). The cumulative inflammatory burden (CIB) was defined as sum of: average score between each pair of surveillance episodes multiplied by the surveillance interval in years. Potential predictors were correlated with CRN outcome using time-dependent Cox regression. RESULTS: A total of 987 patients were followed for a median of 13 years (IQR, 9-18), 97 (9.8%) of whom developed CRN. Multivariate analysis showed that the CIB was significantly associated with CRN development (HR, 2.1 per 10-unit increase in CIB (equivalent of 10, 5 or 3.3 years of continuous mild, moderate or severe active microscopic inflammation); 95% CI 1.4 to 3.0; P<0.001). Reflecting this, while inflammation severity based on the most recent colonoscopy alone was not significant (HR, 0.9 per-1-unit increase in severity; 95% CI 0.7 to 1.2; P=0.5), a mean severity score calculated from all colonoscopies performed in preceding 5 years was significantly associated with CRN risk (HR, 2.2 per-1-unit increase; 95% CI 1.6 to 3.1; P<0.001). CONCLUSION: The risk of CRN in UC is significantly associated with accumulative inflammatory burden. An accurate CRN risk stratification should involve assessment of multiple surveillance episodes to take this into account.
Assuntos
Colite Ulcerativa/complicações , Neoplasias Colorretais/etiologia , Adulto , Colite Ulcerativa/patologia , Colonoscopia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Vigilância da População , Estudos Retrospectivos , Medição de Risco/métodos , Fatores de Risco , Índice de Gravidade de Doença , Adulto JovemRESUMO
OBJECTIVE: Low adenoma detection rates (ADR) are linked to increased postcolonoscopy colorectal cancer rates and reduced cancer survival. Devices to enhance mucosal visualisation such as Endocuff Vision (EV) may improve ADR. This multicentre randomised controlled trial compared ADR between EV-assisted colonoscopy (EAC) and standard colonoscopy (SC). DESIGN: Patients referred because of symptoms, surveillance or following a positive faecal occult blood test (FOBt) as part of the Bowel Cancer Screening Programme were recruited from seven hospitals. ADR, mean adenomas per procedure, size and location of adenomas, sessile serrated polyps, EV removal rate, caecal intubation rate, procedural time, patient experience, effect of EV on workload and adverse events were measured. RESULTS: 1772 patients (57% male, mean age 62 years) were recruited over 16 months with 45% recruited through screening. EAC increased ADR globally from 36.2% to 40.9% (P=0.02). The increase was driven by a 10.8% increase in FOBt-positive screening patients (50.9% SC vs 61.7% EAC, P<0.001). EV patients had higher detection of mean adenomas per procedure, sessile serrated polyps, left-sided, diminutive, small adenomas and cancers (cancer 4.1% vs 2.3%, P=0.02). EV removal rate was 4.1%. Median intubation was a minute quicker with EAC (P=0.001), with no difference in caecal intubation rate or withdrawal time. EAC was well tolerated but caused a minor increase in discomfort on anal intubation in patients undergoing colonoscopy with no or minimal sedation. There were no significant EV adverse events. CONCLUSION: EV significantly improved ADR in bowel cancer screening patients and should be used to improve colonoscopic detection. TRIAL REGISTRATION NUMBER: NCT02552017, Results; ISRCTN11821044, Results.
Assuntos
Adenoma/diagnóstico por imagem , Colonoscópios , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Adenoma/patologia , Neoplasias Colorretais/patologia , Diagnóstico Diferencial , Inglaterra , Desenho de Equipamento , Feminino , Humanos , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Melhoria de QualidadeRESUMO
BACKGROUND: Patients with suspected colorectal cancer (CRC) usually undergo colonoscopy. Flexible sigmoidoscopy (FS) may be preferred if proximal cancer risk is low. We investigated which patients could undergo FS alone. METHODS: Cohort study of 7375 patients (≥55 years) referred with suspected CRC to 21 English hospitals (2004-2007), followed using hospital records and cancer registries. We calculated yields and number of needed whole-colon examinations (NNE) to diagnose one cancer by symptoms/signs and subsite. We considered narrow (haemoglobin <11 g/dL men; <10 g/dL women) and broad (<13 g/dL men; <12 g/dL women) anaemia definitions and iron-deficiency anaemia (IDA). RESULTS: One hundred and twenty-seven proximal and 429 distal CRCs were diagnosed. A broad anaemia definition identified 80% of proximal cancers; a narrow definition with IDA identified 39%. In patients with broad definition anaemia and/or abdominal mass, proximal cancer yield and NNE were 4.8% (97/2022) and 21. In patients without broad definition anaemia and/or abdominal mass, with rectal bleeding or increased stool frequency (41% of cohort), proximal cancer yield and NNE were 0.4% (13/3031) and 234. CONCLUSION: Most proximal cancers are accompanied by broad definition anaemia. In patients without broad definition anaemia and/or abdominal mass, with rectal bleeding or increased stool frequency, proximal cancer is rare and FS should suffice.
Assuntos
Anemia Ferropriva/diagnóstico por imagem , Colo/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico por imagem , Hemorragia Gastrointestinal/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Anemia Ferropriva/complicações , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/patologia , Estudos de Coortes , Colo/patologia , Colonoscopia , Neoplasias Colorretais/complicações , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Feminino , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Reto/diagnóstico por imagem , Reto/patologia , SigmoidoscopiaRESUMO
BACKGROUND AND AIMS: Distal attachments placed on the colonoscope tip may positively affect performance by assisting insertion and polyp detection. The original Endocuff (ARC Medical Design, Leeds, United Kingdom) appears to improve adenoma detection rate (ADR), but no data assess the performance of the second-generation Endocuff Vision. METHODS: A pilot service evaluation study (April 2013 to September 2014) was conducted on patients with positive fecal occult blood tests within the National Bowel Cancer Programme during 3 consecutive periods: precuff/no device used, during-cuff/device used, and postcuff/no device used. During the middle period the use of the Endocuff Vision by the 4 screening-accredited colonoscopists was discretional (nonrandomized design). Data were analyzed using pairwise comparisons during the 3 designated periods to examine key performance indicators: adenoma detection, procedural time, sedation requirements, and patient comfort. RESULTS: Four hundred ten complete colonoscopies were performed (137 precuff, 136 cuff, and 137 postcuff period). Overall, there was a notable increase in the mean ADR of 16% (P < .03) and in the mean number adenoma per procedure (MAP) of 83% (P = .007) from precuff to cuff period. The mean cecal intubation time was statistically lower during the cuff period (7 minutes) in relation to the precuff period (8 minutes; reduction of 12.5%, P = .002) and the postcuff period (9 minutes; increase of 28.6%, P = .002). The mean negative colonoscopy withdrawal time was also significantly lower during the cuff period (8 minutes, 30 seconds) when compared with the precuff (12 minutes) or postcuff period (9 minutes, 45 seconds; P ≤ .001). Multivariate regression analysis showed that the use of the Endocuff Vision was not associated with sedation requirements or patient discomfort scores. No adverse events were reported from the use of the Endocuff Vision, although it was electively removed in 6 patients where severe sigmoid colon diverticulosis was encountered and 2 patients because of discomfort during anal insertion. CONCLUSIONS: In this pilot service evaluation study, the use of the Endocuff Vision appears to be associated with an improvement in overall colonoscopy operator performance. We found increased ADR and MAP as well as decreased time for colonoscope insertion and withdrawal time with no increase in sedation requirements or patient discomfort.
Assuntos
Centros Médicos Acadêmicos , Adenoma/diagnóstico , Colonoscopia/instrumentação , Neoplasias Colorretais/diagnóstico , Idoso , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Sangue Oculto , Projetos Piloto , Análise de Regressão , Fatores de TempoRESUMO
BACKGROUND: Delayed bleeding is the most common significant complication after piecemeal endoscopic mucosal resection (p-EMR) of large nonpedunculated colorectal polyps (NPCPs). Risk factors for delayed bleeding are incompletely defined. We aimed to determine risk factors for delayed bleeding following p-EMR. METHODS: Data were analyzed from a prospective tertiary center audit of patients with NPCPsâ≥â20âmm who underwent p-EMR between 2010 and 2012.âPatient, polyp, and procedure-related data were collected. Four post p-EMR defect factors were evaluated for interobserver agreement and included in analysis. Delayed bleeding severity was reported in accordance with guidelines. Predictors of bleeding were identified. RESULTS: Delayed bleeding requiring hospitalization occurred after 22 of 330 procedures (6.7â%). A total of 11 patients required blood transfusion; of these, 4 underwent urgent colonoscopy, 1 underwent radiological embolization, and 1 required surgery. Interobserver agreement for identification of the four post p-EMR defect factors was moderate (kappa range 0.52â-â0.57). Factors associated with delayed bleeding were visible muscle fibers (Pâ=â0.03) and the presence of a "cherry red spot" (Pâ=â0.05) in the post p-EMR defect. Factors not associated with delayed bleeding were American Association of Anesthesiologists class, aspirin use, polyp size, site, and use of argon plasma coagulation. CONCLUSIONS: Visible muscle fibers and the presence of a "cherry red spot" in the resection defect were associated with delayed bleeding after p-EMR. These findings suggest evaluation and photodocumentation of the post p-EMR defect is important and, when considered alongside other patient and procedural factors, may help to reduce the incidence and severity of delayed bleeding.